Labshake search
Citations for GE Life Sciences :
351 - 400 of 5743 citations for Copper;5 10 15 20 tetrakis 4 methylphenyl porphyrin 22 24 diide since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Immunology 2024Quote: ... loaded with 15 mL of Ficoll-Paque Premium (GE Healthcare) to which a 3 mL cushion of PBS had been slowly added on top of the Leucosep porous barrier ...
-
bioRxiv - Biophysics 2020Quote: ... SEC was conducted at 4°C using a Superdex 200 5/150 column on an AKTA Pure System (GE Healthcare Life Sciences, Marlborough, MA) with a flow rate of 0.15 mL/min and 0.5 s exposures ...
-
bioRxiv - Plant Biology 2024Quote: ... at a 1 to 20 ratio in Buffer A overnight at 4°C followed by a subtractive His trap purification using a 5 mL HisTrap HP column (GE Healthcare, Little Chalfont, UK) (GE Healthcare ...
-
bioRxiv - Biophysics 2021Quote: ... The lysate was centrifuged in a Beckman 45Ti rotor at 100,000 x g for 30 min at 4 °C and the supernatant applied to a HiLoad 26/10 Q Sepharose column (GE Life Sciences) equilibrated in 90 % buffer A and 10% buffer B (buffer A ...
-
bioRxiv - Neuroscience 2024Quote: ... Lysates were spun down at 14000 rpm at 4°C for 10 minutes and supernatant were incubated with GammaBind Sepharose (GE Healthcare, # 17088501) beads premixed with 1µg/mL rabbit α-mouse SorCS2 F7378 (DAKO custom-made polyclonal ab against the cytoplasmic tail of mouse SorCS2 ...
-
bioRxiv - Immunology 2021Quote: ... The mix was next applied to a 24 mL Superdex 75 increase (GE Healthcare) column equilibrated in 20 mM HEPES pH 7.5 ...
-
bioRxiv - Biophysics 2021Quote: ... suspended in buffer QA (10 mM Tris pH 8 and 1 mM EDTA) and loaded into a MonoQ 5/50 GL column (GE Healthcare). After a step-wise wash with 10% and 20% of buffer QB (Buffer QA supplemented with 2M NaCl) ...
-
bioRxiv - Molecular Biology 2021Quote: ... 5 or 10 µg of the purified RNA was resolved on formaldehyde agarose gels and transferred onto nylon membranes (GE Healthcare) by capillary blotting and fixed by UV-crosslinking ...
-
bioRxiv - Molecular Biology 2020Quote: ... Purified NanR at 10 mg mL-1 (340 μM) was injected (70 μL) onto an inline Superdex S200 5/150 Increase (GE Healthcare), equilibrated with buffer C ...
-
bioRxiv - Molecular Biology 2020Quote: Wild type or ΔN20 hMcm10-ID (200 µL at 5 mg ml-1) was injected into Superdex 75 Increase 10/300 GL column (GE Healthcare) operating with the elution buffer containing 20 mM Tris-HCl ...
-
bioRxiv - Plant Biology 2020Quote: ... Desalting columns (NAP-5 and PD-10) and N-[6-(Biotinamido)hexyl]-3’-(2’-pyridyldithio)proprionamide (HPDP-biotin) were purchased from GE Healthcare and Pierce ...
-
bioRxiv - Molecular Biology 2020Quote: ... divided into aliquots of 10 mL and each aliquot was added on top of a 5 mL of Ficoll-Paque Premium (GE Healthcare) in 15 mL sterile Falcon tubes ...
-
bioRxiv - Biophysics 2021Quote: ... 50 mM NaCl and 10 mM β-ME and loaded onto a 5 ml HiTrap SP anion exchange column (GE Healthcare). The binary complex ScNatC was then eluted using a salt gradient (50–750 mM NaCl) ...
-
bioRxiv - Biochemistry 2022Quote: ... of GlOCPX or SynOCP1 samples (5 mg/ml in 50 μl) was performed on a Superdex 200 Increase 10/300 column (GE Healthcare) connected to a Prostar 335 detector (Varian ...
-
bioRxiv - Biochemistry 2022Quote: ... The separated species were concentrated to 1.3 - 2.5 mg/ml and 200 µl of each were applied to a Superose 6 Increase 10/300 GL column (GE Healthcare) equilibrated with SEC buffer and connected to a miniDAWN TREOS II triple-angle light scattering detector (Wyatt Technologies ...
-
bioRxiv - Biochemistry 2021Quote: ... The sample was diluted 5-fold with buffer A (50 mM Tris pH 7.5, 10 mM β-mercaptoethanol) before loading onto a MonoS 5/50 GL column (GE Healthcare) with buffer A supplemented with 100 mM NaCl ...
-
bioRxiv - Biochemistry 2021Quote: ... The sample was diluted 3-fold with dilution buffer (50 mM Tris pH 7.5, 10 mM β-mercaptoethanol) before loading onto a MonoS 5/50 GL column (GE Healthcare) with buffer A (50 mM Tris pH 7.5 ...
-
bioRxiv - Biochemistry 2022Quote: ... of each protein were loaded at 5-8 mg mL−1 onto a pre-equilibrated Superdex 200 10/300 GL size-exclusion column (GE Healthcare) attached to multi-angle light scattering (DAWN HELEOS 8 ...
-
bioRxiv - Molecular Biology 2020Quote: ... and RNA primer 5’-rCrArGrUrGrCrUrArUrGrUr GrArGrArUrUrArArGrUrUrArU-3’ were prepared by solid phase synthesis on an ÄKTA oligopilot plus 10 (GE Healthcare). RNAs were cleaved from the solid support by treating with 4 mL of a 1:1 mixture of 28% wt NH3/H2O solution and 33% wt CH3NH2/EtOH solution at 55°C for 30 minutes ...
-
bioRxiv - Cell Biology 2021Quote: ... FLAG-eluted motor domains (wild-type + jordan) were bound to a strong anion exchanger (5/50 MonoQ GL; Cytiva) using a Purifier 10 chromatography system (GE Healthcare). The column was washed with MOPS (10) ...
-
bioRxiv - Molecular Biology 2022Quote: ... 5 or 10 μg of the purified RNA was resolved on formaldehyde agarose gels and transferred onto nylon membranes (GE Healthcare) by capillary blotting and fixed by UV-crosslinking ...
-
bioRxiv - Neuroscience 2022Quote: ... DARPins after IMAC purification were analyzed at a concentration of 10 µM on a Superdex 75 5/150 GL column (GE Healthcare) using an Aekta Micro system (GE Healthcare ...
-
bioRxiv - Neuroscience 2024Quote: Molecular masses of purified gephyrin and variants were detected by analytical size exclusion chromatography (SEC) using a Superose 6 increase 5/10 (GE Healthcare). Typically ...
-
bioRxiv - Biochemistry 2023Quote: ... A 2-fold molar excess of LF was mixed with 925 pmoles of hexon and incubated on ice for 5 min followed by SEC on Superose 6 increase 10/300 (GE Healthcare) equilibrated with buffer D ...
-
bioRxiv - Biophysics 2023Quote: ... The successfully cleaved samples were subsequently buffer exchanged using a Superdex S200 5/150 GL or 10/300 increase column (GE Healthcare) connected to an Agilent HPLC 1260 Affinity equipped with a fraction collector ...
-
bioRxiv - Cell Biology 2023Quote: ... Rab35BD and Rac1BD-Rab35BD) (40 µL; 10-25 mg/ml) were loaded onto a Superdex-200 increase 5/150 column (GE Healthcare) or BioSec5 300 (Agilent ...
-
bioRxiv - Biophysics 2023Quote: ... The sample was then diluted with dilution buffer (50 mM HEPES (pH 7.2) and 5% glycerol) to reduce the salt concentration and loaded onto a Mono S 10/100 GL column (GE Healthcare). The column was washed with buffer C (50 mM HEPES (pH 7.2) ...
-
bioRxiv - Biochemistry 2024Quote: ... Here 70 µL of purified AaSiaP protein at 10 mg mL−1 was injected onto an inline Superdex S200 Increase 5/150 GL (GE Healthcare) SEC column ...
-
bioRxiv - Microbiology 2024Quote: ... The cleavage solution was desalted using a HiPrepTM 26/10 Desalting column (Cytiva) before reverse affinity chromatography using the 5 ml Histrap column (GE Healthcare). Cleaved protein collected in the flow-through fraction was concentrated (30 kDa cut-off ...
-
bioRxiv - Neuroscience 2024Quote: ... Refolded and soluble proteins were concentrated using Vivaspin 20 or Amicon 15 centrifugal concentrators (10 kDa, 5 kDa, or 3 kDa molecular weight cutoff) and further purified on Superdex S75 columns (GE Healthcare) in SEC buffer (50 mM HEPES ...
-
bioRxiv - Microbiology 2024Quote: ... Human monocyte cell line U937 was maintained at 37°C in 5% CO2 and RPMI 1640 medium supplemented with 10% heat-inactivated fetal bovine serum (FBS) (Hyclone, GE Healthcare). Differentiation of U937 monocytes in macrophages was induced with 100 ng/ml phorbol 12-myristate 13-acetate (PMA ...
-
bioRxiv - Biophysics 2024Quote: ... The eluate was concentrated with 5 kDa spin concentrator and loaded on a Superdex 200 Increase 10/300 column (GE Healthcare) using 20 mM HEPES pH 7.5 ...
-
bioRxiv - Neuroscience 2021Quote: ... The affinity tag for Munc18 was cleaved by 2 mg of TEV in PBS with 400 mM imidazole overnight at 4℃ and additional purification was performed using superdex 200 10/300 GL (GE Healthcare, Piscataway, NJ) gel filtration column in TBS buffer (20 mM Tris pH 7.5 ...
-
bioRxiv - Biophysics 2020Quote: ... concentrated again (10kDa Amicon®Ultra-4 centrifugal filters) and further purified via gel filtration (Superdex-200 10/300, GE Healthcare Life Sciences). After removal of the poly-E tag with the 3C protease (MERCK) ...
-
bioRxiv - Biophysics 2020Quote: ... concentrated again (10kDa Amicon®Ultra-4 centrifugal filters) and further purified via gel filtration (Superdex-200 10/300, GE Healthcare Life Sciences). After removal of the poly-E tag located on the “alive” subunit with 3C protease (MERCK ...
-
bioRxiv - Cancer Biology 2021Quote: ... The concentrated supernatant was loaded on a Tricorn 10/300 Sepharose 4 Fast Flow (S4FF) size exclusion chromatography column (GE Healthcare, Buckinghamshire, UK) connected to the ÄKTA prime system (GE Healthcare) ...
-
bioRxiv - Neuroscience 2022Quote: ... see Figure 3 for detergent content) was added to 10 μl of packed beads: Protein G Sepharose 4 Fast Flow (GE Healthcare Life Sciences) for mouse antibodies or Protein A Sepharose 4 Fast Flow (GE Healthcare Life Sciences ...
-
bioRxiv - Molecular Biology 2024Quote: ... on an Akta Pure chromatography system using a Tricorn 10/300 column with Sepharose 4 Fast Flow resin (all GE Healthcare Life Sciences). EVs were then sterilized by 0.45 μm syringe-filtration ...
-
bioRxiv - Biochemistry 2024Quote: ... CezanneCAT was eluted by cleavage of the GST tag with 15 units/ml TEV protease (SigmaT4455-1KU) in PBS buffer overnight at 4°C and desalted using a PD-10 column (GE Healthcare, cat. # 17085101) in 50 mM Tris-HCl pH 7.5 ...
-
bioRxiv - Cell Biology 2021Quote: ... 20 µg of GST fusion protein and 20 µl of Glutathione Sepharose 4B Beads (GE Healthcare) were incubated with 1 ml of HeLa cell extract for 2 h at 4°C ...
-
bioRxiv - Biochemistry 2021Quote: ... Protein samples at concentrations >5 mg/ml were loaded onto a Superdex™ 200 Increase 10/300 GL size exclusion chromatography column (GE Healthcare) in 20 mM Tris pH 8.0 ...
-
bioRxiv - Cell Biology 2021Quote: ... 10% (v/v) glycerol and 1 mM DTT) and injected onto a MonoQ 5/50 GL column (GE Healthcare and Life Sciences) at 1 mL/min ...
-
bioRxiv - Biophysics 2022Quote: ... coli upec-117 CapW at 5 mg/mL was injected onto a Superdex 200 Increase 10/300 GL column (GE Life Sciences) in buffer GF ...
-
bioRxiv - Biochemistry 2022Quote: ... Protein samples at concentrations >5 mg/ml were loaded onto a Superdex™ 200 Increase 10/300 GL size exclusion chromatography column (GE Healthcare) in 20 mM Tris pH 8.0 ...
-
bioRxiv - Biochemistry 2020Quote: ... 10% glycerol at pH 8.2) and loaded onto a 5 mL prepacked Q-sepharose ion exchange column (GE Healthcare Life Sciences, MA) at 1 mL/min ...
-
bioRxiv - Bioengineering 2021Quote: Several DSAs were performed to guide the intervention by injecting approximately 5-10 ml of a half-strength contrast agent (CA) (50% of Omnipaque 240 (GE Healthcare, USA) and 50% of a saline solution ...
-
bioRxiv - Biochemistry 2020Quote: ... 100 μL purified proteins at 2-5 mg/mL were injected onto a Superdex 200 Increase 10/300 GL column (GE Life Sciences) in gel filtration buffer ...
-
bioRxiv - Microbiology 2022Quote: ... The leukocyte-depleted red blood cell pellet was then resuspended in 10 ml PBS and 5 ml were carefully layered on 6 ml of 70% (v/v) isotonic Percoll cushion (GE Healthcare, UK). After centrifugation at 1200 x g for 15 mins ...
-
bioRxiv - Biochemistry 2023Quote: ... 100 µL of purified proteins at 5 mg/mL were injected onto a Superdex 200 Increase 10/300 GL column (GE Life Sciences) in buffer GF ...
-
bioRxiv - Cell Biology 2023Quote: ... Protein samples at concentrations >5 mg/ml were loaded onto a Superdex™ 200 Increase 10/300 GL size exclusion chromatography column (GE Healthcare) in 20 mM Tris pH 8.0 ...