Labshake search
Citations for GE Life Sciences :
201 - 250 of 4168 citations for 7 Oxa 1 thia 3 azaspiro 4.4 non 2 ene 4 6 dione 2 amino 8 8 dimethyl 9CI since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2023Quote: ... of which 450 µl were subjected to isoelectric focusing on pH 4-7 IPG strips (GE Healthcare), followed by SDS-PAGE with 12 % acrylamide gels ...
-
bioRxiv - Biochemistry 2023Quote: ... plate 2 - 1.6 μg/μL carboxylate beads (1:1 mixture of hydrophilic and hydrophobic beads [mass/mass], GE Healthcare Cat ...
-
bioRxiv - Biochemistry 2022Quote: ... lysates in PBS with protease and phosphatase inhibitor cocktails were injected (500 µL per injection, corresponding to 1–3 mg total protein) onto a Superose® 6 10/300GL column (GE Life Sciences) equilibriated with PBS (pH 7.2 ...
-
bioRxiv - Biochemistry 2023Quote: ... The sample was concentrated to 2-3 mL for separation on exclusion size chromatography (HiLoad 16/600 SuperdexTM 75pg, GE Healthcare; ÄKTA Avant). Finally ...
-
bioRxiv - Immunology 2020Quote: Total IgG1 antibodies were captured from 2 µL of serum using Protein G Sepharose 4 Fast Flow beads (GE Healthcare, Uppsala, Sweden) in a 96-well filter plate (Millipore Multiscreen ...
-
bioRxiv - Immunology 2019Quote: Total IgG antibodies were captured from 2 µL of plasma using Protein G Sepharose 4 Fast Flow beads (GE Healthcare, Uppsala, Sweden) in a 96-well filter plate (Millipore Multiscreen ...
-
bioRxiv - Cell Biology 2019Quote: Each oligonucleotide contained an amino group at the 3’ end for fluorophore coupling using either Cy5 NHS ester (GE Healthcare, PA15102) or rhodamine NHS ester (ThermoFisher ...
-
bioRxiv - Molecular Biology 2022Quote: ... Low-molecular-weight RNAs were separated on 6% acrylamide/7 M urea gels and transferred to a Hybond-XL membrane (GE Healthcare) by electrotransfer ...
-
bioRxiv - Molecular Biology 2024Quote: ... The complex was desalted by a Zeba spin desalting column (7 kDa MWCO) and further purified by size exclusion chromatography using a Superose 6 10/300 column (GE Healthcare). Fluorescein- labeling efficiency was analyzed by SDS-PAGE and fluorescence gel imaging (Amersham Typhoon FLA 9500 ...
-
bioRxiv - Molecular Biology 2024Quote: ... The complex was desalted by a Zeba spin desalting column (7 kDa MWCO) and further purified by size exclusion chromatography using a Superose 6 10/300 column (GE Healthcare). Fluorescein-labeling efficiency was analyzed by SDS-PAGE and fluorescence gel imaging (Amersham Typhoon FLA 9500 ...
-
bioRxiv - Cell Biology 2020Quote: ... 2) the reaction mix was purified using anion exchange column (HiTrap QFF 1 mL; GE Healthcare); 3 ...
-
bioRxiv - Cancer Biology 2021Quote: ... and after 1 and 2 days of co-culture on an INCell Analyzer 2200 (GE Healthcare), with a large field-of-view sCMOS camera (resolution 2048×2048 pixels ...
-
bioRxiv - Microbiology 2021Quote: ... 2 mM β-mercaptoethanol) and applied to a 1-ml Hi-Trap Heparin column (GE Healthcare) equilibrated with TGED ...
-
bioRxiv - Neuroscience 2020Quote: The two animals (Monkey 1 and Monkey 2) were scanned on a Discovery MI (GE Healthcare) PET/CT scanner ...
-
bioRxiv - Biochemistry 2021Quote: ... and diluted with an equal volume of 50 mM Tris pH 8 before loading onto HiTrap Heparin HP columns (GE Healthcare). After extensive washing with 50 mM Tris pH 8 ...
-
bioRxiv - Biochemistry 2020Quote: ... All products were resolved on 12% polyacrylamide gels containing 8 M urea and visualized using Typhoon Trio fluorescence imager (GE Healthcare).
-
bioRxiv - Biochemistry 2019Quote: SEC-MALS was conducted using a Wyatt Dawn 8+ detector (Wyatt Technology) coupled to a Superdex 75 10/300 column (GE Healthcare) and a refractive index detector ...
-
bioRxiv - Neuroscience 2020Quote: ... The lysates were centrifuged at 18000 rpm (F21-8×50y rotor) for 45 min and supernatants were purified by Ni2+-affinity chromatography (FPLC system ÄKTA Purifier, GE Healthcare) eluting the protein in 50 mM NaPO4 ...
-
bioRxiv - Biochemistry 2020Quote: ... The reaction products were separated by denaturing (8 M urea) 10% PAGE and were visualized by using a Typhoon phosphorimager (GE Healthcare). As described previously,48 band intensities were determined and used to estimate the fraction of RNAs bound to ligand ...
-
bioRxiv - Biophysics 2020Quote: ... eluate fractions from the Ni2+-NTA column containing the nsp7-8-His6 were concentrated and the buffer exchanged with a PD-10 desalting column (GE Healthcare) equilibrated with 50 mM Tris ...
-
bioRxiv - Neuroscience 2022Quote: ... Co-immunoprecipitants were resolved on an 8% SDS-PAGE gel followed by protein transfer on nitrocellulose membrane (GE Healthcare Life Sciences). Western blot analysis was performed as described above.
-
bioRxiv - Microbiology 2021Quote: ... A constant amount of total RNA (between 3.5 and 14 μg) was loaded on 8% urea acrylamide gel in 1X TBE and transferred to a nitrocellulose membrane (GE Healthcare). For detection ...
-
bioRxiv - Immunology 2022Quote: ... After equilibration of the IPG strips in reduction buffer and alkylation buffer proteins were separated according to their molecular weight in the second dimension using a gradient gel (8%-15%) in an Ettan DALT II system (GE Healthcare). The gels were then scanned at the different wavelengths using a Typhoon 9400 Laser Scanner (GE Healthcare ...
-
bioRxiv - Biochemistry 2019Quote: ... Fractions were analyzed in a Commasie stained 8% SDS-polyacrylamide gel and gel lanes were scanned using a Typhoon 9400 laser imager (GE Healthcare). Scanned gels were analyzed using ImageQuant TL v2005 software and the two peak fractions were pooled and concentrated to 8.5 mg/ml in 79 μl ...
-
bioRxiv - Biochemistry 2019Quote: ... The eluted proteins were analyzed in an 8% SDS-polyacrylamide gel and scanned and quantitated using a Typhoon 9400 laser imager (GE Healthcare).
-
bioRxiv - Plant Biology 2021Quote: ... and proteins were separated by SDS/PAGE on 8-10% (w/v polyacrylamide) gels and transferred to PVDF membranes (Semi-Dry-Blot, GE Healthcare). After transfer ...
-
bioRxiv - Molecular Biology 2021Quote: ... 2 mM EDTA (pH 6.8) prior to purification by size exclusion chromatography using a gel filtration column (HiLoad 26/60 Superdex 75 column, GE Healthcare). The sample was concentrated using a 10 kDa molecular weight cut-off centrifugal filter (Merck Millipore) ...
-
bioRxiv - Biophysics 2024Quote: ... pure fractions were buffer-exchanged into the final buffer (20 mM Tris-HCl, pH 8, and 150 mM NaCl) using a HiPrep Desalting column (GE Healthcare) and stored at -20°C in the final buffer ...
-
bioRxiv - Molecular Biology 2024Quote: ... the unbound fractions were collected and applied to a Sours 15 Q ion exchange sorbent (column V = 8 mL, GE Healthcare) at a rate of 5 mL/min ...
-
bioRxiv - Immunology 2024Quote: ... Proteins were dialyzed against 10 mM Tris (pH 8) and purified by ion exchange (Q column) followed by size exclusion (S200, GE Healthcare) chromatography ...
-
bioRxiv - Biophysics 2023Quote: ... The NP without MBP containing buffer was diluted to reach 150 mM NaCl concentration by adding 20 mM NaH2PO4 pH 8 and loaded on a heparin column (GE Healthcare) to remove bound bacterial RNA ...
-
bioRxiv - Biochemistry 2023Quote: ... a final gel filtration step was performed in GF buffer (30 mM HEPES pH 8, 250 mM NaCl, 10 mM TCEP) using a S200 size exclusion chromatography column (GE Healthcare).
-
bioRxiv - Plant Biology 2023Quote: ... gel analysis were pooled and dialyzed against Tris-HCl buffer (30 mM Tris-HCl, pH 8) using PD-10 Desalting Columns (GE Healthcare). The protein concentration was determined by Bradford assays with BSA (bovine serum albumin ...
-
bioRxiv - Cancer Biology 2024Quote: ... The denatured proteins were resolved on 8–12 polyacrylamide-SDS gels and transferred onto PVDF membrane (GE Healthcare, Chicago, IL, USA). A molecular weight marker was added onto each gel for reference (Precision Plus Protein Dual Color ...
-
bioRxiv - Neuroscience 2024Quote: ... Protein was separated on an 8-16% gradient Tris-glycine gels and transferred to PVDF blotting membrane (GE Healthcare Life Sciences). The membrane was immunoblotted with 1:200 anti-FGF13 antibody or 1:200 anti-pan FHF-A (Neuromab clone N235/22 ...
-
Deletion or inhibition of PTPRO mitigates diet-induced hepatic steatosis and inflammation in obesitybioRxiv - Immunology 2022Quote: ... Isoelectric focusing (IEF) was performed using 7-cm Immobiline DryStrips (pH 3–11 nonlinear) (GE Healthcare Life Sciences, USA) in an Ethan IPGphor II Isoelectric Focusing System (GE Healthcare Life Sciences ...
-
bioRxiv - Biochemistry 2022Quote: ... MBNL1 (amino acids 1-269 of MBNL140) was obtained in pGEX-6P1 (GE Healthcare). Plasmids were transformed into E ...
-
bioRxiv - Molecular Biology 2021Quote: ... 2 mM L-Glutamine (GE Life Sciences #SH30852.01), 100 units/mL Penicillin and 100 μg/mL Streptomycin (Corning #30-001-CI ...
-
bioRxiv - Cell Biology 2021Quote: ... GST-hEBP50 in pGEX-6P-2 (GE Healthcare): GST-hEBP50/WT (AA95-168) ...
-
bioRxiv - Biochemistry 2022Quote: ... 2 mM βME using Glutathione Sepharose (GE Healthcare). Protein was cleaved overnight using thrombin (Recothrom ...
-
bioRxiv - Biochemistry 2021Quote: ... 2 mM βME using glutathione sepharose (GE Healthcare). Protein was cleaved overnight using thrombin (Recothrom ...
-
bioRxiv - Neuroscience 2020Quote: ... the 2-D Clean-Up Kit (GE Healthcare) was used following manufacturer’s instructions ...
-
bioRxiv - Microbiology 2021Quote: ... (2) Ni Sepharose fast flow resin (GE Healthcare) chromatography using a step elution from 50 mM to 200 mM Imidazol in Tris buffer B (20 mM Tris/HCl ...
-
bioRxiv - Cell Biology 2019Quote: ... 2 mM βME using glutathione sepharose (GE Healthcare). Protein was cleaved overnight using thrombin (Recothrom ...
-
bioRxiv - Microbiology 2023Quote: ... 2 µl of either anti-GST (GE Healthcare), anti-HA (Sigma H6908) ...
-
bioRxiv - Cell Biology 2023Quote: ... 2% horse serum (GE Healthcare, Vélizy-Villacoublay, France), 0.5% penicillin-streptomycin (Invitrogen)) ...
-
bioRxiv - Cell Biology 2021Quote: ... 0.1 mM ATP) overnight at 4°C and loaded onto a 2-ml Glutathione-Sepharose 4B (GE Healthcare Life Sciences, Piscataway, NJ, USA) column pre-charged with GST-N-WASp-VCA (Nolen & Pollard ...
-
bioRxiv - Biochemistry 2022Quote: ... 1 mg of each of the remaining lysates was diluted four-fold with IP buffer plus 0.1% v/v Triton X-100 and incubated for 2 hr at 4 °C with protein G-Sepharose (GE Healthcare catalog no. 17061801), pre-bound to HA-specific antibody (rabbit anti-HA from Sigma-Aldrich ...
-
bioRxiv - Biochemistry 2020Quote: ... the His6-tagged 14-3-3ε was allowed to equilibrate with the excess of untagged 14-3-3γ (overnight at 4 °C) and then loaded on a 1 ml HisTrap HP column (GE Healthcare) while the flowthrough fraction containing 14-3-3γ was collected ...
-
bioRxiv - Neuroscience 2021Quote: ... Solubilized supernatant was isolated by ultracentrifugation and the supernatant was incubated for 2 h with 2 mL CNBR-activated Sepharose beads (GE healthcare) coupled with 4 mg high-affinity GFP nanobodies (2) ...