Labshake search
Citations for GE Life Sciences :
2251 - 2300 of 3164 citations for Dechlorane Plus Syn Bis Cyclopentene 13C10 99% 100 Ug Ml In Toluene since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2020Quote: ... The eluate was concentrated to 1.0 ml and loaded onto a Superdex 200 size-exclusion column (GE healthcare) in running buffer containing 10 mM Tris pH 7.4 ...
-
bioRxiv - Biochemistry 2021Quote: ... Full PRC2 complex was separated by size-exclusion chromatography on a 24 mL Superose 6 column (GE Healthcare) in 10 mM Tris-HCl pH 7.5 ...
-
bioRxiv - Microbiology 2020Quote: ... The NEC220 and NEC-CBM constructs were passed over 2 x 1 mL HiTrap Talon columns (GE Healthcare), rather than ion exchange as previously described ...
-
bioRxiv - Microbiology 2022Quote: ... Strep-tagged proteins were affinity-purified on an ÄKTA Purifier using 5 ml StrepTrap HP columns (GE Healthcare) according to manufacturer’s instructions ...
-
bioRxiv - Biochemistry 2022Quote: ... Salt concentration is adjusted and protein is loaded on a 10 ml HiTrap Heparin HP column (GE Healthcare) equilibrated in 20 mM HEPES- KOH pH 7.5 ...
-
bioRxiv - Biochemistry 2022Quote: ... Recombinant Sau-MenD was purified at room temperature by IMAC with 5 mL HisTrap HP columns (GE Healthcare) and an imidazole gradient of 20–500 mM over 50 mL ...
-
bioRxiv - Biochemistry 2022Quote: ... The soluble fraction was added to a 5 mL Ni-Sepharose fast-flow resin (GE Healthcare Life Sciences) pre-equilibrated with buffer A at room temperature ...
-
bioRxiv - Biophysics 2022Quote: ... and 0.03% DDM (TE buffer) before anion exchange chromatography using a 6 mL Resource Q column (GE Healthcare). Nucleotide-free Tth V/A-ATPase (Vnucfree ...
-
bioRxiv - Biochemistry 2022Quote: ... to < 1 mL and injected onto a Superdex™ 75 10/300 GL size exclusion column (GE Healthcare) equilibrated in Gel Filtration buffer (20 mM HEPES pH 7.7 ...
-
bioRxiv - Cell Biology 2022Quote: ... Clear lysate was incubated with 0.5 ml packed beads IgG Sepharose 6 Fast-Flow (GE Healthcare, Chicago, IL) for 2-3 hours at 4°C on a tube roller ...
-
bioRxiv - Immunology 2022Quote: ... Cell-free supernatant was applied to the column at 2 mL/min using an AKTA Pure (GE Healthcare), washed ...
-
bioRxiv - Biophysics 2024Quote: ... a 2-elution step Ni2+-affinity chromatography was carried out using a Histrap HP 5 ml (GE Healthcare) on an FPLC apparatus (ÄKTA Pure ...
-
bioRxiv - Cell Biology 2024Quote: ... We then applied the supernatant onto two tandem 5 mL HiTrap Q HP anion exchange columns (GE Healthcare) pre-equilibrated with 20 mM Tris pH 8.0 ...
-
bioRxiv - Biophysics 2024Quote: The PCR product was purified via ion exchange chromatography using a 5 ml HiTrap Q column (GE Healthcare). The column was equilibrated in Buffer A (25 mM HEPES 7.5 ...
-
bioRxiv - Biochemistry 2023Quote: ... Then the solution was injected onto a prewashed SP Sepharose HiTrap column (5 ml, GE Healthcare, Chicago, IL). The column was washed with 20 CV of Buffer D (20 mM HEPES-KOH pH 7.5 ...
-
bioRxiv - Genetics 2023Quote: ... for 45 min and soluble extract was applied to a 5 ml HisTrap FF column (GE healthcare Inc.) using a GE AKTA Avant 25 FPLC system ...
-
bioRxiv - Microbiology 2023Quote: ... proteins were separated by immobilized-metal affinity chromatography (IMAC) on a 5 mL HisTrap HP column (GE Healthcare), previously washed with ddH2O and equilibrated with buffer B (25 mM HEPES/NaOH pH 7.5 ...
-
bioRxiv - Immunology 2022Quote: ... The pellet was resuspended in a 15mL tube in 12 mL of Percoll (GE Healthcare, 17-0891-01). The sample was then centrifuged at 650g for 25 min without brake ...
-
bioRxiv - Biophysics 2023Quote: ... Protein was purified using a 20 mL NiNTA column (Cytiva) attached to an Akta M FPLC (GE Healthcare) and with a 300 mM imidazole elution buffer ...
-
bioRxiv - Microbiology 2023Quote: ... The cell-free lysate was applied to a 5 ml His Trap™ HP column (GE Healthcare, USA) equilibrated in the same buffer ...
-
bioRxiv - Biochemistry 2023Quote: ... and then loaded onto a 24 mL Superdex 200 10/300 GL (GE Healthcare, Cat# 17-5174-01) size exclusion column equilibrated in 20 mM Tris pH [8] (20mM HEPES pH [7.5] for FL SHIP1) ...
-
bioRxiv - Biochemistry 2023Quote: ... and then loaded onto a 24 mL Superdex 200 10/300 GL (GE Healthcare, Cat# 17-5174-01) size exclusion column equilibrated in 20 mM Tris pH [8] ...
-
bioRxiv - Biochemistry 2023Quote: ... The sample was then transferred to a 5 mL tube containing 300 μL CaM-Sepharose resin (GE Healthcare) equilibrated in 50 mM HEPES (pH 7.2 ...
-
bioRxiv - Biochemistry 2023Quote: ... to < 1 mL and injected onto a Superdex™ 75 10/300 GL size exclusion column (GE Healthcare) equilibrated in Gel Filtration buffer (20 mM HEPES pH 7.7 ...
-
bioRxiv - Biochemistry 2023Quote: ... The sample was then applied onto a 120 mL HiLoad 16/600 Superdex 200 column (GE Healthcare, Inc.) equilibrated in buffer B ...
-
bioRxiv - Molecular Biology 2023Quote: ... The concentrated histone octamers were further purified on a 120 ml Superdex 200 size exclusion column (GE Healthcare) with SEC buffer (30 mM HEPES-KOH pH 7.5 ...
-
bioRxiv - Biochemistry 2023Quote: ... The dialyzed solution was then loaded on a 1 ml HisTrap SP FF column (GE Healthcare, Pittsburgh, PA) and eluted using a linear gradient of NaCl (20-500 mM) ...
-
bioRxiv - Biochemistry 2023Quote: ... Filtered lysate was applied to a 1-ml His-Trap (all FPLC columns were obtained from GE Healthcare) column using an ÄKTA FPLC ...
-
bioRxiv - Biochemistry 2023Quote: The ammonium sulfate treated hMDH preps were loaded onto a 5 mL HiTrap Butyl HP column (GE Healthcare). An inverse linear gradient of ammonium sulfate from 1.5 M to 0 M was used to purify hMDH where it eluted at a conductivity of 135 mS/cm ...
-
bioRxiv - Cancer Biology 2023Quote: ... Tissue was then digested with 1 mL of enzyme-free dissociation agent HyClone™ (GE Healthcare Life Sciences) for 5 min at 37°C ...
-
bioRxiv - Microbiology 2023Quote: ... The supernatant was applied onto a self-packaged GST-affinity column (2 mL glutathione Sepharose 4B; GE Healthcare) and contaminant proteins were removed with wash buffer (1×PBS ...
-
bioRxiv - Biophysics 2023Quote: ... centrifuged and applied to a cation exchange chromatography column (5 mL HiTrap SP HP, GE Healthcare Life Science) equilibrated with 25 mM sodium phosphate ...
-
bioRxiv - Biochemistry 2023Quote: ... a second nickel-affinity chromatography was performed (His Trap, 5 mL, GE Healthcare; equilibrated in 10% HisB buffer). Sample was loaded and unbound protein further washed out with 10% HisB ...
-
bioRxiv - Molecular Biology 2024Quote: Clarified lysate was added to 2.3 mL of a 50% IgG Sepharose 6 Fast Flow resin (GE Healthcare) slurry and incubated on a roller for 1 hour ...
-
bioRxiv - Biophysics 2024Quote: ... (1994) but used FPLC steps of heparin-affinity using a HiTrap Heparin-HP 1 ml column (GE Healthcare), followed by anion exchange chromatography using a MonoQ 5/50GL (GE Healthcare ...
-
bioRxiv - Biochemistry 2024Quote: ... TEV protease and non-cleaved protein was removed by IMAC (HisTrap FF Crude column, 5 ml, GE Healthcare) with a linear gradient of imidazole (0-500 mM) ...
-
bioRxiv - Biochemistry 2024Quote: ... The eluents were pooled and directly loaded onto HiTrap Q HP 5 mL anion exchange column (GE Healthcare) pre-equilibrated with buffer D [50 mM Tris-HCl (pH 7.5) ...
-
bioRxiv - Biochemistry 2024Quote: ... The dialyzed solution was then loaded on a 5 ml HiTrap SP FF column (GE Healthcare, Pittsburgh, PA) and eluted using a linear gradient of NaCl (20-500 mM) ...
-
bioRxiv - Molecular Biology 2024Quote: ... DprA was purified from the clarified lysate by two-step chromatography using HisTrap HP 1 mL (GE Healthcare) and HiTrap SP XL 1 mL columns (GE Healthcare) ...
-
bioRxiv - Microbiology 2024Quote: ... The sample was then applied onto a 120- mL HiLoad 16/600 Superdex 200 column (GE Healthcare, Inc.) and eluted with buffer C (20 mM Tris–HCl ...
-
bioRxiv - Plant Biology 2020Quote: ... the supernatant was collected and incubated for 5 min on 1 mL Ni Sepharose® 6Fast Flow (GE Healthcare) equilibrated with 10 mL binding buffer ...
-
bioRxiv - Plant Biology 2020Quote: ... The eluate was concentrated to 2 mL and then loaded onto a Superdex 200 column (GE Healthcare, Cat. #10034543) for size exclusion chromatography (S200 buffer ...
-
bioRxiv - Biophysics 2021Quote: ... 10 μM ZnCl2 and 1 mM DTT) and loaded into a HiTrap Heparin HP 5 ml column (GE Healthcare) equilibrated with 6.25% of buffer HepB (buffer HepA supplemented with 2 M NaCl) ...
-
bioRxiv - Neuroscience 2021Quote: ... filtered through 0.45 μm cut-off filters and loaded onto a HiTrap SP HP 5 ml column (GE Healthcare) for cation exchange ...
-
bioRxiv - Evolutionary Biology 2020Quote: ... The cleaved protein was then concentrated to 2.0 ml final concentration and loaded on the S200 column (GE healthcare). S200 size exclusion chromatography has yielded a single peak around 230 KDa ...
-
bioRxiv - Cell Biology 2022Quote: ... Filtered supernatant was loaded into a 5 mL Histrap column (Cytiva) connected to an FPLC AKTAxpress system (GE Healthcare). After affinity binding ...
-
bioRxiv - Biochemistry 2020Quote: ... purification of the protein was performed with a histidine affinity column (HisTrap FF crude 5 ml, GE Healthcare Amersham) taking advantage of the natural His present in the octapeptide repeat region of PrP ...
-
bioRxiv - Molecular Biology 2019Quote: ... XPG and XPA containing lysate was applied onto GE HisTrap HP 5 mL (GE Healthcare, Little Chalfont, United Kingdom) equilibrated in lysis buffer (in case of XPA all downstream steps were performed in the presence of 5 mM β-mercaptoethanol and 10 μM ZnCl2 instead of 1 mM DTT) ...
-
bioRxiv - Molecular Biology 2019Quote: ... The supernatant was filtered (0.45 µm pore) and loaded onto a 5 ml HisTrap FF column (GE Healthcare, USA). After extensively washing with buffer NA supplemented with 35 mM imidazole ...
-
bioRxiv - Cell Biology 2019Quote: ... Matrical Bioscience) were coated with a filtered solution of Concanavalin A (0.5 mg/ml, 17-0450-01, GE Healthcare) for 30min ...