Labshake search
Citations for GE Life Sciences :
101 - 150 of 5411 citations for Adenovirus Type 5 Hexon Protein since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Molecular Biology 2022Quote: ... Proteins were loaded on a 5 ml HisTrap™HP column (1 mL/min; GE Healthcare) in a binding buffer containing 100 mM tris-HCl pH 8 ...
-
bioRxiv - Molecular Biology 2023Quote: ... Lysate containing the protein of interest was loaded onto a 5 mL HisTrap column (GE Healthcare) equilibrated in 200 mM potassium phosphate ...
-
bioRxiv - Bioengineering 2023Quote: ... Affinity purification of the protein was achieved using a StrepTrap HP 5 mL column (GE Healthcare) in binding buffer consisting of 100 mM tris-HCl ...
-
bioRxiv - Biochemistry 2019Quote: ... The recombinant Mtb-MenD protein was purified by IMAC with 5 mL HisTrap HP columns (GE Healthcare) using an imidazole gradient of 20–500 mM over 90 mL ...
-
bioRxiv - Biophysics 2021Quote: Purified protein or cell lysates were injected onto a Superose 6 increase 5/150 column (GE Healthcare), running in a buffer containing 20 mM Tris (pH 7.5) ...
-
bioRxiv - Molecular Biology 2021Quote: ... The resulting protein fraction was further purified on a 5 ml Hi-Trap HP SP (GE Healthcare) cation exchange column using an Akta Pure FPLC ...
-
bioRxiv - Cell Biology 2021Quote: ... The next morning the cleaved protein was loaded on a 5 ml HiTrap HeparinHP column (GE Healthcare). The protein was eluted over a gradient from 100 mM to 2M KCl ...
-
bioRxiv - Biochemistry 2020Quote: ... the proteins were buffer exchanged into the appropriate buffer using an Illustra NAP-5 column (GE Healthcare).
-
bioRxiv - Microbiology 2022Quote: ... Periplasmic proteins were extracted and CusF was purified on a 5 ml StrepTrap HP column (GE healthcare) equilibrated with buffer A (10 mM NaPi ...
-
bioRxiv - Cancer Biology 2020Quote: ... Eluted protein was further purified using an anion exchange column (HiTrap Q HP 5 ml; GE Healthcare) before buffer exchange into PBS and storage at –20°C.
-
bioRxiv - Molecular Biology 2020Quote: ... Proteins were diluted to 75 mM NaCl and loaded onto a MonoQ 5/50 GL (GE Healthcare) equilibrated in QO buffer (20 mM Tris pH 8 ...
-
bioRxiv - Immunology 2021Quote: ... Supernatant was harvested after 4-5 days and antibody purified on Protein G Sepharose (Abcam, GE Healthcare) following standard protocols ...
-
bioRxiv - Pharmacology and Toxicology 2020Quote: ... Membranes were washed (6×5 min) with TBS-T and proteins were visualized by quimioluminiscence (GE Healthcare Amersham™ ECL™ Western Blotting Detection Reagents ...
-
Targeting properdin - Structure and function of a novel family of tick-derived complement inhibitorsbioRxiv - Immunology 2021Quote: ... protein extract was fractionated by anion exchange chromatography using a MonoQ 5/50 GL column (GE Healthcare), washed with 10 column volumes (CV ...
-
bioRxiv - Immunology 2021Quote: ... IFN-α2 protein was column-purified using Nap-5 columns (GE Healthcare, Chicago, IL; #17-0853-01), incubated with 2.5ul serum ...
-
bioRxiv - Immunology 2020Quote: ... 5-10 μg denaturated proteins were resolved by SDS-PAGE and transferred to nitrocellulose membranes (GE Healthcare). Antibodies against HOIL1 (H-1 ...
-
bioRxiv - Cell Biology 2023Quote: ... The proteins were purified by nickel affinity chromatography using a 5 ml HisTrap HP column (GE Healthcare). The eluted proteins were dialyzed into 20 mM Tris-HCl ...
-
bioRxiv - Microbiology 2023Quote: ... Protein was purified using an anion exchange chromatography column (HiTrap Q HP, 5 mL; GE Life Sciences) followed by ammonium sulfate precipitation (20 to 30% ammonium sulfate saturation ...
-
bioRxiv - Neuroscience 2023Quote: ... the dialyzed protein was applied to a 5 ml HisTrapTM column (GE Life Sciences, 17-5248-02), equilibrated with dialysis buffer ...
-
bioRxiv - Neuroscience 2023Quote: ... the dialyzed protein was applied to a 5 ml HisTrapTM column (GE Life Sciences, 17-5248-02), equilibrated with dialysis buffer ...
-
bioRxiv - Biochemistry 2023Quote: ... The protein was purified using nickel affinity chromatography with a 5 ml HisTrap HP column (GE Healthcare) followed by size exclusion chromatography on a HiLoad Superdex 75 16/600 column (GE Healthcare) ...
-
bioRxiv - Molecular Biology 2023Quote: ... The eluted protein was separated on a 5 ml HiTrap STREP column (GE Healthcare, Little Chalfont, UK), and eluted with 2 mM desthiobiotin ...
-
bioRxiv - Biophysics 2020Quote: ... The proteins were then purified by cation exchange using a 5-mL HiTrap SP HP column (GE Healthcare) and the collected fractions analyzed by SDS-PAGE ...
-
bioRxiv - Cell Biology 2020Quote: ... The cleaved dCas9 protein was further purified with a 5 ml SP Sepharose HiTrap column (GE Life Sciences) in 20 mM HEPES pH 7.5 ...
-
bioRxiv - Molecular Biology 2022Quote: ... The supernatants containing the protein extracts were then applied onto a HisTrap FF 5 ml column (GE Healthcare) loaded with nickel ions using an ÄKTA Start liquid chromatography machine (GE Healthcare) ...
-
bioRxiv - Cell Biology 2019Quote: ... Equal amount of 5-10µg proteins were resolved by SDS-PAGE and transferred to nitrocellulose membranes (GE Healthcare). Membranes were revealed using a chemiluminescent HRP substrate (Millipore ...
-
bioRxiv - Biochemistry 2021Quote: ... Cleaved DEPTOR protein was then collected and applied to a 5 mL HiTrap Heparin HP column (GE Healthcare) equilibrated with HEP-A buffer (50 mM HEPES pH 8 ...
-
bioRxiv - Immunology 2022Quote: ... 5% glucose) and the proteins purified by affinity chromatography using a HiTrap Heparin High-Performance column (GE Healthcare) and gradient elution (0-100% NaCl ...
-
bioRxiv - Molecular Biology 2019Quote: ... The proteins from the cleared cell lysate were captured in a HisTrap HP 5 ml column (GE Healthcare) in His buffers (20 mM MOPS ...
-
bioRxiv - Biochemistry 2019Quote: ... The protein was then purified by anion exchange chromatography on a MonoQ 5/50 GL column (GE Healthcare) using buffers AEX-A and AEX-B with a gradient of 7.5-50% B over 20 CV at a flow rate of 1 ml/min ...
-
bioRxiv - Cell Biology 2021Quote: Approximately 5 μg of GST or GST-tagged protein fragments were incubated in Glutathione-Sepharose beads (GE Healthcare) in GST-lysis buffer at 4°C overnight ...
-
bioRxiv - Microbiology 2022Quote: ... Strep-tagged proteins were affinity-purified on an ÄKTA Purifier using 5 ml StrepTrap HP columns (GE Healthcare) according to manufacturer’s instructions ...
-
bioRxiv - Microbiology 2023Quote: ... proteins were separated by immobilized-metal affinity chromatography (IMAC) on a 5 mL HisTrap HP column (GE Healthcare), previously washed with ddH2O and equilibrated with buffer B (25 mM HEPES/NaOH pH 7.5 ...
-
bioRxiv - Biochemistry 2023Quote: ... Aurora A protein was thawed and buffer exchanged in the experimental buffer using NAP-5 Columns (GE Healthcare). Experiments typically involved titrating 25 µM of protein in the sample cell with 300 µM of compound in the syringe ...
-
bioRxiv - Molecular Biology 2021Quote: ... The protein fraction eluted with 250 mM imidazole was purified further by MonoQ 5/50 GL column (GE Healthcare) at pH 8.0 ...
-
bioRxiv - Biochemistry 2020Quote: ... purification of the protein was performed with a histidine affinity column (HisTrap FF crude 5 ml, GE Healthcare Amersham) taking advantage of the natural His present in the octapeptide repeat region of PrP ...
-
bioRxiv - Molecular Biology 2019Quote: Clarified extracts containing hexahistidine fusion proteins were passed through a 5 mL Ni-Sepharose (GE Healthcare #17-5268-01) packed column at 0.5 mL/min using an ÄKTAprime Plus chromatography system ...
-
bioRxiv - Molecular Biology 2019Quote: ... Clarified extracts containing GST fusion proteins were passed through a 5 mL GSTrap column (GE Healthcare #17-5131-02) at 0.1 mL/min using an ÄKTAprime Plus chromatography system (GE Healthcare) ...
-
bioRxiv - Biochemistry 2021Quote: ... The cleaved protein was then passed over a HisTrap™ FF Ni2+ column (5 ml/min, GE Life Sciences) and washed with Buffer B and the cleaved topo VI collected in the flow through ...
-
bioRxiv - Biochemistry 2021Quote: ... The protein was additionally purified by ion-exchange chromatography on a “Mono S 5/50 GL” column (GE healthcare) at 0-100% B gradient over 15 column volumes at 0.5 ml/min flow rate using 20 mM sodium phosphate buffer (pH 6.0 at 25 °C ...
-
bioRxiv - Biochemistry 2020Quote: Soluble protein was manually applied at room temperature to a 5 mL HiTrapQ anion exchange column (GE Healthcare # 29051325) that had been pre-equilibrated in buffer B ...
-
bioRxiv - Biochemistry 2020Quote: ... Proteins were then further purified by anion exchange chromatography using a 5 ml HiTrap Q HP column (GE Healthcare) across a gradient of 100 mM to 1M NaCl ...
-
bioRxiv - Microbiology 2020Quote: ... The membranes were then washed five times for 5 min and proteins were detected with Amersham ECL (GE Healthcare). Images were taken using the iBright Imaging System (Invitrogen).
-
bioRxiv - Biophysics 2021Quote: ... The 6xHis-tagged protein samples were loaded onto pre-equilibrated Ni2+ affinity resin (HisTrap HP 5 ml, GE Healthcare). The column was sequentially washed with HSU buffer containing 0.5% triton-X ...
-
bioRxiv - Immunology 2022Quote: ... 5% Glucose and the proteins purified by cation-exchange chromatography using a HiTrap SP High-Performance columns (GE Healthcare), followed by size exclusion chromatography using a HiLoad 16/600 Superdex 75pg column (GE Healthcare) ...
-
bioRxiv - Biochemistry 2021Quote: ... purification of the protein was performed with a histidine affinity column (HisTrap FF crude 5 ml, GE Healthcare Amersham) taking advantage of the natural His present in the octapeptide repeat region of PrP ...
-
bioRxiv - Biochemistry 2020Quote: ... purification of the protein was performed with a histidine affinity column (HisTrap FF crude 5 ml, GE Healthcare Amersham) taking advantage of the natural His present in the octapeptide repeat region of PrP ...
-
bioRxiv - Biochemistry 2019Quote: ... Diluted protein samples in buffer C were loaded on a heparin HP 5 mL column (GE Healthcare, Chicago, IL) and protein was eluted with buffer D (25mM Tris pH 7.6 ...
-
bioRxiv - Plant Biology 2020Quote: ... The extracts were incubated with 5 μL anti-HA antibodies coupled with 30 μL Protein-A Sepharose (GE Healthcare) overnight at 4 °C ...
-
bioRxiv - Biophysics 2020Quote: ... The protein was purified from the supernatant of the lysate using a 5 ml HisTrap HP column (GE Healthcare). The Smt3 tag was cleaved off before further purification by a HiLoad 16/600 Superdex 75 size exclusion column (GE Healthcare ...