Labshake search
Citations for GE Life Sciences :
1401 - 1450 of 3197 citations for 6 Bromo 2 trifluoromethylimidazo 1 2 a pyridine since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cell Biology 2023Quote: ... Analytical size-exclusion chromatography was carried out under isocratic conditions on a Superose 6 5/150 or Superdex 200 5/150 (GE Healthcare) equilibrated with SEC buffer (50 mM HEPES pH 8.0 ...
-
bioRxiv - Microbiology 2022Quote: ... SDS-gels were stained by “Blue-Silver” Coomassie Staining (Candiano et al., 2004) and washed with water for 6 hours or overnight before imaging with LAS4000 (GE Healthcare).
-
bioRxiv - Biochemistry 2022Quote: ... The protein was further purified by size exclusion chromatography (SEC) using a Superose 6 Increase 10/300 GL column (GE Healthcare) equilibrated with Buffer A ...
-
bioRxiv - Biochemistry 2022Quote: ... The fractions that contained the protein were concentrated and further purified at 4 °C on a preparative Superose 6 XK 16/70 size exclusion column (GE Healthcare) equilibrated with 25 mM HEPES.Na pH 7.5 ...
-
bioRxiv - Biochemistry 2022Quote: ... 500 µg clarified supernatant from P2 fractions was further fractionated by size-exclusion chromatography (SEC) on a Superose 6 increase column (GE Healthcare) equilibrated with LB buffer (25 mM HEPES pH 7.4 ...
-
bioRxiv - Biophysics 2023Quote: ... Samples were injected on the Äkta prime plus chromatography system (Cytivia) and separated on a Superose 6 10/300 column (GE Healthcare) in SEC buffer (10 mM HEPES ...
-
bioRxiv - Neuroscience 2023Quote: ... and pellets were resuspended in 6 mL 25 % Standard Isotonic Percoll (Percoll: GE Healthcare, 17-5445-02 with 10% 10x PBS) in Medium A ...
-
bioRxiv - Cell Biology 2023Quote: ... The GST-tagged Bridge domain was purified by affinity chromatography with glutathione-SepharoseTM 4B resins (Cytiva) followed by size exclusion chromatography with Superose 6 10/300 (GE Healthcare) in the running buffer containing 150 mM NaCl and 20 mM HEPES (pH 7.5).
-
bioRxiv - Biophysics 2023Quote: ... The His6-SUMO-14-3-3ζ fusion protein was purified by immobilized metal affinity chromatography (IMAC) using Ni Sepharose 6 Fast Flow resin (5 mL; GE Healthcare) with standard IMAC procedures of sample application ...
-
bioRxiv - Biophysics 2023Quote: ... The mixed complexes were incubated over night at 4 °C and the formed R2SP complex was separated from excess SPAG1/PIH1D2 using a Superose 6 16/60 XK (GE Healthcare), see Supplementary Information for detailed protocol ...
-
bioRxiv - Biophysics 2023Quote: ... the protein was diluted 10 times with PBS buffer and immobilized on a Nickel Sepharose 6 Fast Flow resin (GE Healthcare). The resin was washed extensively with milliQ water followed by PBS buffer pH 7.4 ...
-
bioRxiv - Molecular Biology 2023Quote: ... The concentrated protein sample was centrifuged at 10,000 × g and 4°C for 10 min before the supernatant was loaded onto a lysis buffer equilibrated Superose 6 increase 10/300 GL column (GE Healthcare), connected to a 1260 Bioinert Infinity LC system and equipped with a multi-angle light scattering detector (miniDawn 3141MD3 ...
-
bioRxiv - Biophysics 2023Quote: ... The protein was further concentrated by a 100-kDa cutoff concentrator (Milipore) and loaded onto a Superose 6 increase 10/300 column (GE Healthcare) running in lysis buffer with 1 mM MgCl2 and 0.03% digitonin ...
-
bioRxiv - Biophysics 2023Quote: ... The protein was further concentrated by a 100-kDa cutoff concentrator (Milipore) and loaded onto a Superose 6 increase 10/300 column (GE Healthcare) running in lysis buffer with 0.03% digitonin ...
-
bioRxiv - Biochemistry 2023Quote: ... The sample was concentrated with a 100 kDa cutoff concentrator to 500 μL and loaded on a Superose 6 Increase 10/300 column (GE Healthcare) equilibrated with gel filtration buffer (20 mM Tris-HCl pH 7.4 ...
-
bioRxiv - Biochemistry 2023Quote: ... the soluble fraction was passed over the appropriate affinity resin of Strep-Tactin XT Superflow (IBA) or Ni Sepharose 6 Fast Flow affinity resin (GE Healthcare), eluted with wash buffer (50 mM Tris–HCl pH 8.0 ...
-
bioRxiv - Biophysics 2023Quote: Size exclusion chromatography (SEC) was performed using ÄKTAprocess 6 mm Std system controlled by the Unicorn 7.0 software (GE Healthcare, Sweden). Sepharose 6 Fast Flow beads (GE Healthcare ...
-
bioRxiv - Cell Biology 2022Quote: Cellular lysates were separated on a Superose 6 HR 10/30 size-exclusion column and an AKTA Purifier protein purification system (GE Healthcare), essentially as described previously(61) ...
-
bioRxiv - Biochemistry 2022Quote: ... The ACE2-induced postfusion S-nanodisc sample was purified by gel filtration chromatography on Superose 6 Increase 10/300 column (GE Healthcare) in a buffer containing 25 mM Tris-HCl ...
-
bioRxiv - Biophysics 2023Quote: ... The concentrated protein sample was further purified by size exclusion chromatography (SEC) using a Superose 6 Increase 10/300 GL (GE Healthcare) column pre-equilibrated with the buffer E (20 mM HEPES pH 7.5 ...
-
bioRxiv - Biochemistry 2023Quote: ... After His-tag purification protein was subsequently purified by size exclusion chromatography using a Superose 6 Increase 10/300 column (GE Healthcare). The oligomeric state of CsoSCA-MBP was determined from the Superose 6 Increase chromatogram and a calibration standard (Bio-Rad) ...
-
bioRxiv - Biochemistry 2023Quote: ... The proteins were eluted with HBS containing 200 mM imidazole and further purified using size-exclusion chromatography (Superdex 200 Increase 10/300 or Superose 6 Increase 10/300 columns; GE Healthcare) in 10 mM Tris ...
-
bioRxiv - Plant Biology 2023Quote: ... for 2 hours and then extensively washed with lysis buffer and eluted in lysis buffer with 5mM desthiobiotin and further purified by size-exclusion chromatography with Superose 6 increase 10/300 GL-column (GE Healthcare).
-
bioRxiv - Immunology 2023Quote: ... Plasma lipoproteins were separated using fast-performance liquid chromatography with two Superose 6 10/300 GL columns (GE Healthcare; Boston, MA) on a Shimadzu HPLC system (Columbia ...
-
bioRxiv - Immunology 2023Quote: ... Affinity-purified proteins were incubated with HRV-3C protease to remove purification tags and subsequently purified by size-exclusion-chromatography on a Superose 6 Increase column (GE Healthcare) in TBS
-
bioRxiv - Immunology 2023Quote: ... protein was purified using cell-free culture supernatant by StrepTactin resin (IBA) and by size-exclusion chromatography using Superdex 200 (RBD and NTD) or Superose 6 (S-2P) column (GE Healthcare) in 10 mM Tris pH8 ...
-
bioRxiv - Cell Biology 2023Quote: ... Elution was performed with imidazole and the second step of purification was performed using Superose 6 Increase 10/300 GL gel filtration chromatography (GE Healthcare).
-
bioRxiv - Biochemistry 2023Quote: ... The harvested cells were lysed by pulsed sonication and the soluble fraction was affinity purified using Ni2+-Sepharose (Ni Sepharose 6 Fast Flow, GE Healthcare). The resulting MsLadC variants ...
-
bioRxiv - Biophysics 2023Quote: ... The 6×His-tagged SUMO fusion proteins were purified using a HisTrap™ HP Ni2+ affinity column (GE Healthcare Life Sciences). The fractions containing fusion protein were pooled and exchanged into a SUMO protease cleavage buffer (20 mM Tris-HCl at pH 8.0 ...
-
bioRxiv - Biophysics 2023Quote: ... The eluted sample was concentrated using an Amicon Ultra Centrifugal Filter (MWCO 100 kDa) and purified by Superose 6 Increase 10/300 column (GE Healthcare) pre-equilibrated with buffer containing 20 mM HEPES pH 7.5 ...
-
bioRxiv - Biochemistry 2023Quote: ... the sample was treated with 100 mM phosphate buffer pH 7.5 and 50 mM EDTA before purification by gel filtration at room temperature on a Superose-6 Increase column (GE Healthcare) equilibrated with buffer containing 25 mM TRIS pH 8 ...
-
Faa1 membrane binding drives positive feedback in autophagosome biogenesis via fatty acid activationbioRxiv - Biochemistry 2023Quote: ... The cleaved protein was concentrated and loaded onto a Superose 6 Increase size exclusion chromatography column (10/300 prep grade, GE Healthcare). Elution was carried out with 150 mM NaCl ...
-
bioRxiv - Biochemistry 2023Quote: ... dIgA-604 and SIgA-604 were purified using Ni-NTA beads (Smart-Lifesciences) and a Superose 6 Increase column (GE Healthcare).
-
bioRxiv - Biophysics 2023Quote: ... protein samples were purified by size-exclusion chromatography at 4°C using a Superose 6 10/300 GL column (GE Healthcare), equilibrated with a buffer containing 0.03% (w/v ...
-
bioRxiv - Immunology 2023Quote: ... The S proteins were then separated by chromatography using resin attached with streptavidin and further purified by size exclusion chromatography using a Superose 6 10/300(GE Healthcare) in 20 mM Tris ...
-
bioRxiv - Biophysics 2024Quote: ... The protein was concentrated using a 100 kDa filter to approximately 1 mL and further purified by size-exclusion chromatography at 4°C using a Superose 6 10/300 GL column (GE Healthcare) equilibrated with buffer containing 0.06% digitonin ...
-
bioRxiv - Biochemistry 2024Quote: ... The sample was concentrated to 100 µL using a 100 kDa MWCO concentrator and the concentrate was loaded onto a size-exclusion chromatography (SEC) column (Superose 6 Increase 10/30 GL, GE Healthcare), equilibrated in a buffer composed of 20 mM Tris-Cl (pH 8) ...
-
bioRxiv - Microbiology 2024Quote: ... The fractions containing L–P protein were further purified using a size-exclusion column (Superose 6 Increase 10/300 GL, GE healthcare) equilibrated with size exclusion chromatography (SEC ...
-
bioRxiv - Immunology 2024Quote: ... The S proteins were then separated by chromatography using resin attached with streptavidin and further purified by size exclusion chromatography using a Superose 6 10/300(GE Healthcare) in 20 mM Tris ...
-
bioRxiv - Molecular Biology 2024Quote: ... The complex was desalted by a Zeba spin desalting column (7 kDa MWCO) and further purified by size exclusion chromatography using a Superose 6 10/300 column (GE Healthcare). Fluorescein- labeling efficiency was analyzed by SDS-PAGE and fluorescence gel imaging (Amersham Typhoon FLA 9500 ...
-
bioRxiv - Immunology 2024Quote: ... Fab was purified from clarified culture supernatant six days post-transfection using Ni-NTA affinity chromatography with IMAC Sepharose 6 Fast Flow resin (GE Healthcare). Gel filtration on a Superdex 75 10/300 column (GE Healthcare ...
-
bioRxiv - Molecular Biology 2024Quote: ... The complex was desalted by a Zeba spin desalting column (7 kDa MWCO) and further purified by size exclusion chromatography using a Superose 6 10/300 column (GE Healthcare). Fluorescein-labeling efficiency was analyzed by SDS-PAGE and fluorescence gel imaging (Amersham Typhoon FLA 9500 ...
-
bioRxiv - Microbiology 2020Quote: ... S protein was purified by running the supernatant through a streptactin column and then by size exclusion chromatography using a Superose 6 increase 10/300 column (GE Healthcare Biosciences). Protein fractions corresponding to the trimeric S protein were collected and concentrated.
-
bioRxiv - Cell Biology 2020Quote: ... Elutions with CAV1 were concentrated and further purified by size exclusion chromatography using Superpose 6 Increase 10/300 GL (GE Healthcare, Illinois) equilibrated with a buffer composed of 200 mM NaCl ...
-
bioRxiv - Immunology 2022Quote: ... BG505 Env trimer was purified from transfected cell supernatants as described47 by 2G12 immunoaffinity and size-exclusion chromatography (SEC) with a Superose 6 16/600 column followed by Superdex 200 Increase 10/300 GL column (GE Life Sciences).
-
bioRxiv - Biochemistry 2019Quote: ... 100 μL of purified protein/complex at 2-5 mg/mL was injected onto a Superdex 200 Increase 10/300 GL or Superose 6 Increase 10/300 GL column (GE Life Sciences) in a buffer containing 20 mM HEPES pH 7.5 ...
-
bioRxiv - Cell Biology 2019Quote: Size exclusion chromatography experiments with HeLa cell extracts were performed with a pre-packed Superose 6 10/300 GL column (GE Healthcare ©). The column was equilibrated with buffer A (20 mM Hepes ...
-
bioRxiv - Microbiology 2019Quote: ... The concentrated protein complex was further purified using size-exclusion chromatography with a Superose-6 Increase 10/300-GL (GE Life Sciences) column equilibrated in Buffer B (50 mM HEPES ...
-
bioRxiv - Molecular Biology 2019Quote: ... Affinity-purified proteins were subjected to size-exclusion chromatography on a Superdex 200 10/300 column or on a Superose 6 5/150 column (GE Healthcare, Germany) in gel filtration buffer (50 mM Hepes pH 8.0 ...
-
bioRxiv - Genomics 2021Quote: ... Neisseria sicca and Neisseria elongata was migrated on a 6% polyacrylamide gel and then transferred onto nitrocellulose membrane (Amersham Hybond™ N+ from GE healthcare). The oligonucleotides were labeled in 5’ by using 5 pmoles of oligonucleotide ...