Labshake search
Citations for GE Life Sciences :
1201 - 1250 of 4701 citations for 7 16 DIHYDROBENZO A BENZO 5 6 QUINO 3 2 I ACRIDINE 9 18 DIONE since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cancer Biology 2019Quote: ... The concentrated protein was further purified using HiLoad 16/600 Superdex-75 prep-grade gel-filtration column (GE Healthcare) pre-equilibrated with 20mM Tris HCl [pH 7.5] ...
-
bioRxiv - Biochemistry 2020Quote: ... The concentrated sample was further purified over a Superdex 200 Hi-load 16/60 gel filtration column (GE Healthcare) pre-equilibrated with 20 mM potassium phosphate (pH 7.4) ...
-
bioRxiv - Biophysics 2019Quote: ... The eluted proteins from Ni-NTA column were loaded onto a Hi-load 16/60 Superdex 200 (GE Healthcare) gel filtration column pre-equilibrated with 25mM Tris pH 8.0 ...
-
bioRxiv - Genomics 2021Quote: ... Peak fractions were pooled and subjected to size exclusion chromatography using a Superdex 200 16/600 column (GE healthcare) equilibrated in buffer A3 (50 mM HEPES-NaOH ...
-
bioRxiv - Microbiology 2021Quote: ... Fractions containing purified His6-MrpC were combined and loaded onto a HiLoad 16/600 Superdex 200 pg (GE Healthcare) size exclusion chromatography column equilibrated with lysis buffer without imidazole ...
-
bioRxiv - Biophysics 2021Quote: ... 0.5 M NaCl pH 8) on a HiPrep Q FF 16/10 anion exchange column (GE Healthcare, Uppsala, Sweden). aSyn was then dialysed into buffer C (1 M (NH4)2SO4 ...
-
bioRxiv - Biochemistry 2021Quote: ... Q-eTud3 and Q-eTud5 were concentrated and loaded on a HiLoad Superdex 75 16/600 column (GE Healthcare) pre-equilibrated with size-exclusion buffer (25 mM Tris-HCl pH 7.8 ...
-
bioRxiv - Biochemistry 2021Quote: ... size exclusion chromatography was carried out on a HiLoad® 16/60 Superdex® pg 200 column (GE Healthcare) using 20 mM Tris-HCl ...
-
bioRxiv - Biochemistry 2021Quote: ... another step of size exclusion chromatography was performed using a Superdex 16/60 S75 or S200 column (GE Healthcare), with 10 mM HEPES ...
-
bioRxiv - Biochemistry 2021Quote: ... The fractions containing KlNmd4 were then applied onto a S75-16/60 size-exclusion chromatography column (GE Healthcare Biosciences) using buffer B (GE Healthcare Biosciences ...
-
bioRxiv - Neuroscience 2020Quote: ... αSyn-LgBiT and Hsp70 were polished by HiLoad 16/60 Superdex 200 SEC (GE Healthcare Lifesciences, Marlborough, MA, USA); fractions eluting at 68-82 ml and 78-86 ml were collected respectively ...
-
bioRxiv - Biochemistry 2021Quote: ... A size exclusion chromatography was performed with a HiLoad 16/600 Superdex 75 pg column (GE Healthcare Life Sciences) to remove residual imidazole from the protein sample with buffer solution (150 mM sodium chloride ...
-
bioRxiv - Microbiology 2020Quote: ... ∼500 µL of concentrated pooled fractions was loaded onto HiPrep 16/60 Sephacryl S-500 HR column (GE Healthcare) then 1.5 column volume of mobile phase (DPBS ...
-
bioRxiv - Molecular Biology 2020Quote: ... Protein was further purified with size-exclusion chromatography on HiLoad 16/600 Superdex 75 prep grade column (GE Healthcare) in NMR buffer ...
-
bioRxiv - Microbiology 2021Quote: ... The ParD2:ParE2 containing fraction was subsequently applied onto a pre-equilibrated Superdex 200 (16/60) column (GE Healthcare) in SEC buffer (20 mM Tris–HCl pH 8 ...
-
bioRxiv - Microbiology 2020Quote: ... Sgo_R10 and Sgo_R3-4 were further purified by preparative SEC using a Superdex 75 16/600 column (GE Healthcare) equilibrated in 20 mM Tris.HCl ...
-
bioRxiv - Immunology 2021Quote: ... The oligomeric content was evaluated by size-exclusion chromatography using a HiLoad 16/600 column (GE Healthcare, Piscataway, NJ) equilibrated with PBS ...
-
bioRxiv - Biophysics 2021Quote: ... tag cleavage and dialysis followed by gel filtration on a Superdex 75 Hi Load column 16/60 (GE Healthcare) pre-equilibrated with 20mM Tris-HCl pH 8 ...
-
bioRxiv - Molecular Biology 2022Quote: ... The eluted fractions were loaded onto a pre-equilibrated HiLoad 16/600 Superdex 75 prep grade column (GE Healthcare) and purified further ...
-
bioRxiv - Biochemistry 2022Quote: ... centrifuge filters and applied to SEC using a Superdex 200 column (HiLoad 16/600 Superdex 200 pg, GE Healthcare) equilibrated in SEC buffer.
-
bioRxiv - Molecular Biology 2022Quote: ... The resulting sample was applied to a 120 ml HiLoad 16/60 Superdex 200 size-exclusion column (GE Healthcare) equilibrated with 10 mM Tris-HCl ...
-
bioRxiv - Developmental Biology 2022Quote: ... Eluate was centrifuged to remove any precipitate before loading onto HiLoad 16/60 Superdex 200 SEC column (GE Healthcare).
-
bioRxiv - Microbiology 2022Quote: ... and loaded to a Hi-Load 16/600 Superdex-200 pg (preparation grade) size-exclusion chromatography column (GE Healthcare) equilibrated with the gel filtration buffer (100 mM NaCl ...
-
bioRxiv - Microbiology 2022Quote: ... The cleaved protein was collected and further purified using gel filtration (HiLoad 16/60 Superdex pg 200, GE Healthcare) with GF buffer (20 mM Tris-HCl ...
-
bioRxiv - Synthetic Biology 2022Quote: ... For isothermal titration calorimetry experiments F420 was further purified on a HiLoad 16/60 Superdex 30 column (GE Healthcare) equilibrated with 0.3 M ammonium bicarbonate (pH 8.5) ...
-
bioRxiv - Molecular Biology 2022Quote: ... Eluate was concentrated and further purified by size exclusion chromatography over a Superdex 200 16/600 column (GE Healthcare) in buffer containing 200 mM NaCl ...
-
bioRxiv - Microbiology 2022Quote: ... Fractions containing MalE-RomR or MalE-MglC were loaded onto a HiLoad 16/600 Superdex 200 pg (GE Healthcare) gel filtration column that was equilibrated with buffer 1 ...
-
bioRxiv - Microbiology 2023Quote: ... The cleaved protein was concentrated and loaded onto a Superdex 75 16/60 size exclusion (SEC) column (GE Healthcare) pre-equilibrated at 4°C in 20 mM Hepes pH 8 ...
-
bioRxiv - Microbiology 2023Quote: ... The cleaved protein was concentrated and loaded onto a Superdex 200 16/60 size exclusion (SEC) column (GE Healthcare) pre-equilibrated at 4°C in 50 mM Hepes pH 7 ...
-
bioRxiv - Biochemistry 2023Quote: ... The dialyzed sample was subsequently purified by size exclusion chromatography using a Superdex200 HiLoad 16/600 column (GE Healthcare). Fractions were analyzed by SDS-PAGE gel ...
-
bioRxiv - Biochemistry 2023Quote: ... The sample was concentrated before separation on exclusion size chromatography (HiLoad 16/600 SuperdexTM 75pg, GE Healthcare; ÄKTA Avant). Activity of fractions containing partially purified rHAChE was measured using Ellman’s reagent (DTNB ...
-
bioRxiv - Biochemistry 2023Quote: ... tuberculosis RNAP were pooled and applied to a 120 mL HiLoad 16/600 Superdex 200 column (GE Healthcare, Inc.) equilibrated in buffer B ...
-
bioRxiv - Biochemistry 2023Quote: Histone proteins were mixed in stoichiometric amounts and eluted through a HiLoad 16/600 Superdex 200pg column (GE Healthcare) to produce H2A-H2B dimers and (H3-H4)2 tetramers separately 40 ...
-
bioRxiv - Immunology 2023Quote: ... followed by size exclusion chromatography using a HiLoad™ 16/60 Superdex™ 75 gel filtration column (GE Healthcare). The protein was then subjected to TEV protease digestion overnight at 4 °C to remove polyhistidine purification tag ...
-
bioRxiv - Cell Biology 2023Quote: ... Isolated Mic10 was further subjected on HiLoad 16/600 Superdex 200 size exclusion column (GE Healthcare, Piscataway, NJ, USA). Separated fractions were analyzed by SDS-PAGE and Coomassie brilliant blue staining.
-
bioRxiv - Biochemistry 2022Quote: ... AcrAS was directly loaded onto a HiLoad 16/600 Superdex 200 pg size exclusion chromatography (SEC) column (GE Healthcare) equilibrated in buffer C (50 mM sodium phosphate ...
-
bioRxiv - Molecular Biology 2023Quote: ... 0.5 mM TCEP was used while for FP experiments a Superdex200 16 600 column (GE Healthcare, Little Chalfont, UK) equilibrated in 25 mM HEPES pH 7.5 ...
-
bioRxiv - Microbiology 2023Quote: ... Fractions containing predominantly ATeam protein were pooled and applied to a HiLoad 16/600 Superdex 200 column (GE Healthcare) equilibrated with 20 mM tris-HCl ...
-
bioRxiv - Molecular Biology 2023Quote: ... As the final purification step size exclusion chromatography was performed on a Superdex 75 16/600 column (GE Healthcare) with 20 mM HEPES-KOH pH 7.5 ...
-
bioRxiv - Cell Biology 2023Quote: ... TbSmee1(1-400) concentrates were applied to a previously equilibrated HiLoad 16/600 Superdex 200 pg column (GE Healthcare) pre-equilibrated in dialysis buffer ...
-
bioRxiv - Immunology 2024Quote: ... The IgG eluent was further purified via SEC with a HiLoad 16/600 Superdex 200 column (GE Healthcare Biosciences) in 2 mM Tris pH 8.0 ...
-
bioRxiv - Biochemistry 2023Quote: ... The resulting flow-through was concentrated and run on a HiLoad 16/60 Superdex 200 column (GE Life Sciences) into crystallization buffer ...
-
bioRxiv - Molecular Biology 2024Quote: ... and then further purified by size-exclusion chromatography using a HiLoad 16/600 Superdex 200 pg column (GE Healthcare) into 2 mM Tris pH 8.0 ...
-
bioRxiv - Biochemistry 2023Quote: ... NQO1 was further purified by size exclusion chromatography using a HiLoad 16/600 Superdex 200 prep grade (GE Healthcare) column using the elution buffer 20 mM K-HEPES pH 7.4 ...
-
bioRxiv - Cell Biology 2024Quote: ... An extra purification step of Size exclusion chromatography was carried out using an S75 16/600 column (GE healthcare) equilibrated against a PBS buffer pH 7.5 ...
-
bioRxiv - Biophysics 2023Quote: ... The cleavage mix was then passed through a sulphopropyl sepharose column (HiPrep SP FF 16/10 20ml, GE HealthCare) and washed with buffer C ...
-
bioRxiv - Cell Biology 2024Quote: Pooled fractions were further purified using size exclusion chromatography with a HiLoad 16/60 Superdex 200 column (GE Healthcare) in 25 mM HEPES pH 7.5 ...
-
bioRxiv - Microbiology 2022Quote: ... The supernatant was aspirated to the 5 mL mark and the samples were transferred to fresh 15 mL tubes containing 2 mL of 100% Percoll (GE Healthcare catalog no. 17-0891-01). Water was added to the 10 mL mark ...
-
bioRxiv - Physiology 2019Quote: Cardiac dimensions and contractility were assessed by right para-sternal transthoracic echocardiography (Vivid 7; GE Healthcare, UK) in non-sedated conscious sheep gently restrained in a supine position ...
-
bioRxiv - Plant Biology 2023Quote: ... Two mg of proteins in buffer were mixed with 50ul 7-Methyl-GTP-Sepharose 4B (GE Healthcare) previously equilibrated with extraction buffer ...