Labshake search
Citations for GE Life Sciences :
451 - 500 of 4132 citations for Monoisodecyl Phthalate 100 Ug Ml In Mtbe Unlabeled Mono 3 7 Dimethyl 1 Octyl Phthalate since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2021Quote: ... StrepII-CERT was captured using 1 mL StrepTrap HP column (GE Healthcare) that had been pre-equilibrated in wash buffer (100 mM Tris pH 8.0 ...
-
bioRxiv - Biophysics 2020Quote: ... and loaded onto a 1-mL HiTrap IMAC-HP column (GE Healthcare), which was pre-equilibrated with lysis buffer containing 0.1% dodecyl maltoside ...
-
bioRxiv - Molecular Biology 2022Quote: ... a HiTrap Q FF anion exchange chromatography column (1 ml, GE Healthcare) was used on an ÄKTA-FPLC (GE Healthcare ...
-
bioRxiv - Microbiology 2020Quote: ... with a Ni2+ HiTrap IMAC (2 × 1 ml) column (GE Healthcare, Poland) preequilibrated with the binding buffer ...
-
bioRxiv - Immunology 2020Quote: Columns of 1 ml Protein G sepharose 4 fast flow (GE Healthcare) were prepared and equilibrated with 5 volumes of binding buffer (0.02 M sodium phosphate ...
-
bioRxiv - Biophysics 2020Quote: ... we load the solution on a 1 mL MonoQ column (GE Healthcare) using an FPLC system (Äkta Explorer) ...
-
bioRxiv - Biochemistry 2020Quote: ... and loaded on 1 mL HiTrap Heparin HP (GE Healthcare, Cat# 17040601) equilibrated with buffer C (20 mM Tris-HCl pH 8.0 ...
-
bioRxiv - Microbiology 2020Quote: ... The supernatant was loaded onto a 1 ml HisTrap column (GE Healthcare) previously equilibrated with Buffer H ...
-
bioRxiv - Molecular Biology 2020Quote: ... Lysates were applied to tandem 1 mL HiTrap FF columns (Ge Healthcare) charged with Ni2+ ...
-
bioRxiv - Molecular Biology 2019Quote: ... 1 mM TCEP) and applied to a 25 ml Source15Q (GE Healthcare) strong anion exchange column equilibrated in buffer A ...
-
bioRxiv - Biochemistry 2019Quote: ... with an anion-exchange HiTrap Q HP column (1 mL, GE Healthcare) using a salt gradient with a start and end concentration of 100 and 500 mM NaCl in 50 mM Tris-HCl (pH 7.5) ...
-
bioRxiv - Microbiology 2021Quote: ... NEC220 was passed over 2 × 1 mL HiTrap Talon columns (GE Healthcare), rather than ion exchange ...
-
bioRxiv - Microbiology 2020Quote: Proteins were eluted directly into a 1 mL HisTrap column (GE Healthcare) using purification buffer supplemented with Desthiobiotin 2.5 mM (IBA Solutions For Life Science™) ...
-
bioRxiv - Biophysics 2021Quote: ... nanodiscs were purified using a HisTrap HP 1 mL column (GE Healthcare). The column was equilibrated with buffer containing 40 mM Tris ...
-
Myosin VI regulates ciliogenesis by promoting the turnover of the centrosomal/satellite protein OFD1bioRxiv - Cell Biology 2021Quote: ... Supernatants were incubated with 1 ml of glutathione-sepharose-beads (GE Healthcare) per litre of bacterial culture ...
-
bioRxiv - Microbiology 2021Quote: ... and loaded on 1 ml His-Trap columns (GE Healthcare, Freiburg, Germany), pre-equilibrated with ten column volumes of each ddH2O and sodium phosphate buffer A (20 mM Na2HPO4 * 2 H2O ...
-
bioRxiv - Biophysics 2022Quote: ... the sample was injected on a 1 mL HisTrap column (GE Healthcare) equilibrated with Buffer A and washed in Buffer A until the baseline was stable ...
-
bioRxiv - Biophysics 2022Quote: ... samples were loaded onto a 1 ml Resource S column (GE Healthcare) equilibrated with 20 mM MES-NaOH pH 6.0 and bound FimCA ...
-
bioRxiv - Biochemistry 2022Quote: ... The eluate was loaded onto a 1 mL MonoQ column (GE Healthcare) in buffer A (20 mM Tris pH 7.5 ...
-
bioRxiv - Biophysics 2022Quote: ... TOP3A was further purified using a 1 mL HiTrap SP (GE Healthcare) with a gradient from buffer G (50 mM Tris-HCl pH 7.5 ...
-
bioRxiv - Biochemistry 2022Quote: ... Eluted POLD1 was passed into a 1 mL heparin column (GE Healthcare) pre-equilibrated using the same buffer—POLD1 eluted from heparin column in the same buffer at 1 M NaCl ...
-
bioRxiv - Biochemistry 2022Quote: ... a cation exchange purification step (1 ml Resource S column, GE Healthcare) was introduced before size exclusion chromatography ...
-
bioRxiv - Biochemistry 2023Quote: ... Supernatants were loaded in a 1-ml His-Trap column (GE Healthcare) previously equilibrated with buffer H ...
-
bioRxiv - Biochemistry 2022Quote: ... The sample was loaded onto a 1 ml HiTrap column (GE Healthcare) equilibrated in Buffer B (50 mM sodium phosphate ...
-
bioRxiv - Molecular Biology 2022Quote: ... Proteins were applied to a 1 ml HisTrap HP column (GE Healthcare), pre-equilibrated with buffer I (40 mM Tris-HCl ...
-
bioRxiv - Cell Biology 2023Quote: ... This suspension was layered on 1 mL of Percoll (GE Healthcare, #17089101) and centrifuged at 9,560 g for 5 min ...
-
bioRxiv - Microbiology 2024Quote: ... 1 ml of supernatant was added to a Superdex 30 (GE Healthcare) size exclusion column equilibrated with buffer (25 mM Tris at pH 8.0 ...
-
bioRxiv - Biochemistry 2024Quote: ... then loaded onto a 1 ml HiTrap heparin HP column (GE Healthcare) pre-equilibrated in low salt buffer and eluted with a linear gradient of 100 mM to 1 M KCl over 25 CVs.
-
bioRxiv - Cell Biology 2024Quote: ... 1 mM DTT and 4 ml of Q Sepharose resin (GE Healthcare) was mixed to capture GLH-1 protein molecules ...
-
bioRxiv - Cell Biology 2024Quote: ... 1 mM DTT and 5 ml of Q Sepharose resin (GE Healthcare) was mixed to capture PGL-3 protein molecules ...
-
bioRxiv - Bioengineering 2020Quote: ... Echocardiograms were performed with the GE Healthcare Echocardiography Vivid 7 system (GE Healthcare, Chicago, IL) equipped with an i13L probe ...
-
bioRxiv - Microbiology 2019Quote: ... Supernatants were precleared using 20µl of protein G sepahrose beads (GE Healthcare, 7-0618-01) for 1hr at 4°C ...
-
bioRxiv - Zoology 2021Quote: ... in which the computer software (Echo Pac PC 6.3 software for Vivid 7, GE Healthcare) automatically performed speckle tracking ...
-
bioRxiv - Plant Biology 2022Quote: ... 3 mL of the centrifuged supernatant was applied to a PD-10 column filled with Sephadex G-25 resin (GE Healthcare, Chicago, IL, USA) equilibrated with the homogenizing buffer ...
-
bioRxiv - Immunology 2020Quote: ... Dilution series of TBK1 or IRF-3 (1.25, 2.5, 5, 10, 20 μM) in 1× HBS-EP+ buffer (GE Healthcare) were injected over the sensor chip at a flow rate of 30 μL/min ...
-
bioRxiv - Genetics 2020Quote: ... then washed for 3 × 20 min in 1× SSC and 0.1% SDS and imaged using a phosphorimager (GE Healthcare) and scanned using an Amersham Typhoon 5 scanner ...
-
bioRxiv - Immunology 2020Quote: ... 3-fold serial dilution (spanning a range of 1 μM to 1.4 nM) in HBS-EP buffer (GE healthcare). A high flow rate of 40 μL/min was used ...
-
bioRxiv - Microbiology 2024Quote: ... MV samples were administered at six concentrations (1:3 dilutions in Neurobasal A (Hyclone, GE Healthcare, Chicago, IL, USA) containing Glutamax (Hyclone ...
-
bioRxiv - Cell Biology 2021Quote: ... and UNC- 16(1-506) was covalently coupled to a 1-mL HiTrap N-hydroxysuccinimide column (GE Healthcare).
-
bioRxiv - Microbiology 2022Quote: ... Protein samples were solubilized in DHHC Buffer C (1% SDS, 1 mM EDTA, 100 mM HEPES, pH 7.5) and were captured on thiopropyl sepharose 6B (GE Healthcare, 17-0402-01) in the presence of 2 M hydroxylamine or 2 M NaCl (negative control ...
-
bioRxiv - Microbiology 2019Quote: ... before the supernatant was applied at 1 ml/min to a 5 ml chromatography column attached to an ÄKTA Prime plus (GE Healthcare).
-
bioRxiv - Biochemistry 2019Quote: ... Cell debris was removed by centrifugation at 10000xg for 45 min at 4°C and the supernatant was loaded onto either a 1 mL or 5 mL HisTrap FF crude column (GE Healthcare) equilibrated in Ni-1 buffer using a peristaltic pump ...
-
bioRxiv - Microbiology 2022Quote: The solution containing the proteins was loaded on a prepacked 1 ml or 5 ml His Trap HP Nickel column (GE Healthcare), which had been washed with 5 column volumes of water and equilibrated with 5 column volumes of buffer A (20 mM sodium phosphate ...
-
bioRxiv - Molecular Biology 2020Quote: ... The pellet was dissolved in 10 mL of buffer B and loaded onto a 1 mL HiTrap Heparin HP sepharose column (GE Healthcare) equilibrated with buffer B supplemented with 0.1 M NaCl ...
-
bioRxiv - Cell Biology 2023Quote: ... was applied to a previously equilibrated HiTrap Chelating HP 5 ml column charged with 50 mM CoCl2 and coupled to a GSTrap HP 1 ml column (both GE Healthcare). Buffer A was used for equilibration ...
-
bioRxiv - Microbiology 2023Quote: ... The resulting supernatant was applied to a 10-mL column with 1 mL of Ni-Sepharose (GE Healthcare Life Sciences, 17531801) equilibrated with binding buffer (20 mM Tris-HCl ...
-
bioRxiv - Cell Biology 2021Quote: ... A volume of 2.5 ml of soluble fraction was incubated with 100 μl of Glutathione Sepharose beads (GE Healthcare, 17-0756-01) for 1 h at 4°C ...
-
bioRxiv - Cancer Biology 2023Quote: ... the medium was changed and fresh RPMI 1640 supplemented with Activin A (100 ng/mL) and 0.2 % HyClone-defined FBS (GE Healthcare Bio-Sciences) was added ...
-
bioRxiv - Plant Biology 2021Quote: ... 0.8% (v/v) immobilized pH gradient (IPG) buffer pH range 4–7 (GE Healthcare, Uppsala, Sweden)] ...
-
bioRxiv - Immunology 2022Quote: ... mAbs were harvested and purified 7 days after transfection using Protein G Sepharose columns (GE Healthcare). All purified recombinant mAbs were analyzed by SDS-PAGE under reducing conditions using NuPAGE Novex 4-12% Bis-Tris polyacrylamide gels and NuPAGE reducing agent (Life Technologies ...