Labshake search
Citations for GE Life Sciences :
451 - 500 of 4094 citations for 3 Hydrazino 5 methyl 4H 1 2 4 triazol 4 ylamine hydrochloride since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cell Biology 2021Quote: ... Insoluble material was sedimented by centrifugation at 13,500 g for 30 min at 4°C prior to loading on His-trap FF columns (GE Healthcare) pre-equilibrated with lysis buffer ...
-
bioRxiv - Molecular Biology 2022Quote: ... filter and size-exclusion chromatography at 4 °C on a Superdex 200 10/300 GL gel filtration column (GE Healthcare). Purity of the proteins was evaluated on SDS-PAGE gel ...
-
bioRxiv - Pathology 2021Quote: ... the crude protein solution was finally collected by ultracentrifugation (40,000 rpm, 30 min, 4°C) and subsequently incubated with Ni-NTA (GE healthcare) resin for 2 h at 4°C ...
-
bioRxiv - Developmental Biology 2021Quote: ... The remaining supernatant was added to 50 µl G-Protein Sepharose beads (Protein G-Sepharose 4 Fast Flow, GE Healthcare) (pre-washed with the lysis buffer ...
-
bioRxiv - Neuroscience 2020Quote: ... labelled protein samples were subjected to size exclusion chromatography at 4°C (Superdex 200 Increase 10/300 GL, GE Healthcare) in 50 mM phosphate (pH 7.4 ...
-
bioRxiv - Immunology 2022Quote: ... Polyclonal IgG from subject 391370 was isolated from heat-inactivated plasma using Protein G Sepharose 4 Fast Flow (GE Healthcare). Purified IgG was buffer exchanged into Dulbecco’s Phosphate Buffered Saline (DPBS ...
-
bioRxiv - Biophysics 2022Quote: ... the supernatant was dialyzed against 20 mM Tris-HCl pH 8.0, centrifuged (15 min, 48000xg, 4 °C) and loaded onto a 15 ml Q-sepharose FF (GE Healthcare) column equilibrated with the same buffer ...
-
bioRxiv - Microbiology 2020Quote: ... The protein was concentrated using an Amicon Ultra-4 10,000 NMWL before purification by size exclusion chromatography using a Superdex 200 column (GE Healthcare) equilibrated with 20 mM Tris ...
-
bioRxiv - Microbiology 2020Quote: ... Protein was concentrated using an amicon Ultra-4 10,000 NMWL before purification by size exclusion chromatography using a Superdex 200 column (GE Healthcare) equilibrated with 20 mM Tris ...
-
bioRxiv - Biochemistry 2020Quote: ... Ab Spin Trap columns (immobilized protein G) and NHS-activated sepharose® 4 fast flow were purchased from GE Healthcare Life Sciences (Buckinghamshire ...
-
bioRxiv - Cell Biology 2021Quote: ... The lysates were cleared by centrifugation at 100,000 g at 4°C for 30 min and then mixed with Glutathione Sepharose 4B (GE Healthcare). The Sepharose beads were washed with buffer B [50 mM Tris-HCl (pH 8.0) ...
-
bioRxiv - Microbiology 2021Quote: ... Total proteins were separated in a 4–15% SDS–PAGE gradient and transferred to nitrocellulose membrane (GE Healthcare Life Science). Membranes were blocked with 5% (m/v ...
-
bioRxiv - Biophysics 2021Quote: ... Reactions were incubated overnight at 4°C and resolved over a Superose 6 Increase 10/300 GL column (GE Healthcare) preequilibrated with assembly buffer ...
-
bioRxiv - Biophysics 2022Quote: ... the supernatant was dialyzed against 10 mM Tris-HCl pH 8.0, centrifuged (15 min, 48000xg, 4 °C) and passed over a Q-sepharose FF (GE Healthcare) column ...
-
bioRxiv - Biophysics 2022Quote: ... dialyzed against 10 mM acetic acid-NaOH pH 4.0 overnight at 4 °C and loaded onto a 6 ml Resource S column (GE Healthcare) equilibrated in 10 mM acetic acid-NaOH pH 4.0 ...
-
bioRxiv - Biochemistry 2022Quote: ... the resulting supernatant was recovered and centrifuged at 10,000 xg for 10 min at 4°C and then loaded onto a HisTrap column (GE Healthcare) pre-equilibrated with the same resuspension buffer ...
-
bioRxiv - Biophysics 2022Quote: ... The grids were blotted for 4 seconds at force 12 using double-layer Whatman filter papers (1442-005, GE Healthcare) before plunging into liquid ethane using an FEI MarkIV Vitrobot at 8 °C and 100% humidity ...
-
bioRxiv - Cell Biology 2022Quote: ... After centrifugation at 39,000 x g at 4 °C for 20 min the supernatant was incubated with 0.5 ml of pre-equilibrated IgG-Sepharose slurry (GE Healthcare) at 4 °C for 1 h ...
-
bioRxiv - Plant Biology 2022Quote: Analytical size exclusion chromatography was performed at 4°C using a Superdex 75 10/300 gel filtration column (GE Healthcare) pre-equilibrated in 20 mM HEPES pH 7.5 and 150 mM NaCl (Maqbool et al ...
-
bioRxiv - Molecular Biology 2022Quote: ... for 10 min at 4 °C and injected into Superdex 200 Increase 10/300 GL size-exclusion columns (GE Healthcare). Fractions containing both hZnT7 and Fab were collected and concentrated with a 100-kDa cutoff Amicon filter to around 10 mg ml-1 for cryo-EM measurements.
-
bioRxiv - Neuroscience 2022Quote: ... and the soluble proteins were isolated by centrifugation (80,000g, 45 min, 4°C) and purified by cation exchange chromatography (HiTrap SP, GE Healthcare) with a gradient of 0-1M NaCl ...
-
bioRxiv - Microbiology 2023Quote: ... Samples were separated by SDS-PAGE and were transferred from a 4-12 % Bis-Tris NuPAGE gel to a 0.45 µM nitrocellulose membrane (GE Healthcare) using an XCell II Blot module (Invitrogen ...
-
bioRxiv - Cell Biology 2024Quote: ... Eluates containing protein were concentrated to <500µL and size-exclusion was performed at 4°C using an ÄKTA Pure Protein Purification System (GE healthcare) and Superose® 6 Increase 100/300 GL column (Cytiva) ...
-
bioRxiv - Biophysics 2024Quote: ... The resulting suspension was then centrifuged (13,000 rpm for 35 min at 4°C) and the supernatant was applied to a HisTrap HP column (GE Healthcare) previously equilibrated with the lysis buffer ...
-
bioRxiv - Microbiology 2023Quote: ... The eluted fractions containing Cas9-NLS-His were diluted 4-fold with 50 mM Tris-HCl (pH 7.5) and subjected to cation exchange chromatography (Hitrap S HP, GE healthcare) pre-equilibrated with 50 mM Tris-HCl (pH 7.5 ...
-
bioRxiv - Biophysics 2023Quote: ... Pooled fractions were dialyzed against sodium carbonate buffer (pH 5.0) overnight at 4°C and further purified with Resource-S cation exchange column (GE Healthcare). Finally ...
-
bioRxiv - Biophysics 2023Quote: ... The lysate was clarified by centrifugation at 30,000 g for 30 min at 4°C and incubated for 45 min with amylose beads (GE Healthcare). The loaded protein was cleaved on column by GST-tagged 3C protease at 4°C overnight ...
-
bioRxiv - Cell Biology 2023Quote: ... or IgG as a control were immobilized on 50 μl of Protein A–Sepharose 4 Fast Flow beads (GE Healthcare) for 3 h and incubated with clarified lysates.
-
bioRxiv - Neuroscience 2023Quote: ... Approximately 20μg of heat denatured protein lysate of each sample was loaded on a 4-12% SDS-PAGE and then transferred by wet blotting to a 0.45 μm nitrocellulose membrane (GE healthcare). After 1 hr of blocking with 5% Milk in TBST ...
-
bioRxiv - Microbiology 2023Quote: ... overnight at 4°C and purified by a gel filtration HiLoad 26/600 Superdex 200 pg column (GE Healthcare, USA) using the same buffer.
-
bioRxiv - Biochemistry 2023Quote: ... Batch binding was performed overnight with Glutathione resin (Glutathione SepharoseTM 4 Fast Flow, GE Healthcare Cat. no. 17-5132-02) at 4°C ...
-
bioRxiv - Biophysics 2023Quote: ... CFTR was purified by gel filtration chromatography at 4 °C using a Superose 6 10/300 GL column (GE Healthcare), equilibrated with 0.006% (w/v ...
-
bioRxiv - Biochemistry 2024Quote: ... 50 μL of GTL25D1/COLGALT1 concentrated at 4 mg/mL were injected into a Superdex 200 PC 3.2/300 Increase column (GE Healthcare), pre-equilibrated with 25 mM HEPES/NaOH ...
-
bioRxiv - Cell Biology 2024Quote: ... The supernatant was filtered through a 0.45 µm filter and incubated with 4 ml pre-equilibrated GST beads (GE Healthcare). After 1h incubation rolling at 4°C ...
-
bioRxiv - Cell Biology 2024Quote: ... Eluted proteins were further purified over gel filtration at 4°C on a Superdex 200 10/300 GL (GE Healthcare) column the using lysis buffer ...
-
bioRxiv - Genomics 2020Quote: ... The oligonucleotide pool was purified using 2 x illustra NAP-5 Columns (GE Life Sciences, PN: 17085302). The resulting solution was evaporated to dryness ...
-
bioRxiv - Zoology 2020Quote: ... and 3500 V/2 mA/5 W for 6 h using a Multiphor II system (GE Healthcare). The IEF strip was then equilibrated for 15 min in 5 ml equilibration stock solution (6 M urea ...
-
bioRxiv - Biochemistry 2022Quote: The interaction of N proteins and 14-3-3γ was analyzed using a Superdex 200 Increase 5/150 column (GE Healthcare) operated at a 0.45 ml/min flow rate on a Prostar 335 chromatographic system (Varian ...
-
bioRxiv - Cancer Biology 2021Quote: ... Stained plates were washed 3 times in dH2O for 5 minutes at room temperature and air dried before imaging using the Imagescanner III (GE Healthcare). Growth was determined by percentage area of the plate covered by cells using ImageJ v1.52a ...
-
bioRxiv - Plant Biology 2020Quote: ... Each Z-section image is based on 15 images generated from 3 different angles and 5 different SIM patterns and reconstructed using SOFTWORX software (Applied Precision).
-
bioRxiv - Cell Biology 2020Quote: ... membranes were exposed for 10-30 s (in the case of GFP-Plk4) and for 3–5 min (in the case of actin) on a Amersham Imager 680 (GE Healthcare) and images were acquired with its CCD camera.
-
bioRxiv - Genetics 2021Quote: ... The membrane was washed 3 × 5 min in PBST and then visualized by Amersham ECL Prime Western Blot Detection Reagent (GE Healthcare). Images were taken by Fluorescent Image Analyzer LAS-3000 (FujiFilm ...
-
bioRxiv - Molecular Biology 2020Quote: ... and RNA primer 5’-rCrArGrUrGrCrUrArUrGrUr GrArGrArUrUrArArGrUrUrArU-3’ were prepared by solid phase synthesis on an ÄKTA oligopilot plus 10 (GE Healthcare). RNAs were cleaved from the solid support by treating with 4 mL of a 1:1 mixture of 28% wt NH3/H2O solution and 33% wt CH3NH2/EtOH solution at 55°C for 30 minutes ...
-
bioRxiv - Cell Biology 2024Quote: All TIRF experiments (except Figure 3 F and G) were acquired at 37 °C/5% CO2 with the DeltaVision OMX SR microscope (GE Healthcare) with a 60×/1.42 NA oil Plan Apochromat objective (Olympus ...
-
bioRxiv - Neuroscience 2024Quote: ... Refolded and soluble proteins were concentrated using Vivaspin 20 or Amicon 15 centrifugal concentrators (10 kDa, 5 kDa, or 3 kDa molecular weight cutoff) and further purified on Superdex S75 columns (GE Healthcare) in SEC buffer (50 mM HEPES ...
-
bioRxiv - Biophysics 2021Quote: ... The cell lysates were centrifuged at 34,000 × g for 20 min at 4°C and the supernatant containing the His-tagged fusion protein was loaded onto a HisTrap column (AKTA-prime, GE Healthcare). The protein was eluted with a buffer containing 20–500 mM linear imidazole gradient ...
-
bioRxiv - Cell Biology 2020Quote: ... The cell lysate made by sonication was centrifuged at 11,000 rpm for 30 min at 4◦C and the clear supernatant was purified through Ni-NTA column chromatography (GE Healthcare) following kit protocols ...
-
bioRxiv - Genetics 2021Quote: ... 2D gels were exposed for 4 hours in a phosphor screen cassette and the signal was detected with a Typhoon Trio phosphoimager (GE healthcare).
-
bioRxiv - Cell Biology 2022Quote: ... 150 mM NaCl) and GST-fused proteins were immobilized on Glutathione Sepharose 4 Fast Flow beads (GE Healthcare, #17-5132-01) by incubating in a rotator at 4°C for 1 h ...
-
bioRxiv - Biochemistry 2022Quote: ... The lysate was cleared by centrifugation at 40,000 rpm in a Type 45 Ti rotor for 60 minutes at 4 °C and applied onto a pre-equilibrated HisTrap HP column (GE Healthcare) in CENP-E lysis buffer at 4 °C ...