Labshake search
Citations for Quantifoil Micro Tools :
301 - 350 of 736 citations for 6 4 Methyl 1 piperazinyl N 5 methyl 1H pyrazol 3 yl 2 1Z 2 phenylethenyl 4 pyrimidinamine since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Molecular Biology 2023Quote: ... Quantifoil R1.2/1.3 400-square mesh Cu grids with 2 nm continuous carbon (Quantifoil) were glow-discharged for 8 s at 10 mA using a PELCO easiGlow glow discharging system (Ted Pella ...
-
bioRxiv - Biochemistry 2024Quote: ... Three microliters of sample were applied to glow-discharged R2/2 carbon grids (Quantifoil), which were blored for 5 s and at a blot force of 25 and plunge-frozen in liquid ethane with a Vitrobot Mark IV (ThermoFisher ...
-
bioRxiv - Biochemistry 2021Quote: ... 2.5-μL aliquots of purified Neo1 at a concentration of about 1 mg/mL were placed on glow-discharged holey carbon grids (Quantifoil Au R2/2, 300 mesh) and were flash-frozen in liquid ethane using a FEI Vitrobot Mark IV ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... a volume of 6-8 μL of each sample was applied onto a gold grid covered by a holey gold film (UltrAuFoil 2/1, Quantifoil Micro Tools GmbH, Jena, Germany). Excess of liquid was blotted automatically between two strips of filter paper or only from the backside of the Grid ...
-
bioRxiv - Biochemistry 2020Quote: ... KBP was diluted to 0.3 mg/ml in KBP dilution buffer and 4 μl were applied to glow-discharged 1.2/1.3 AuFoil gold grids (Quantifoil®). For the third approach ...
-
bioRxiv - Molecular Biology 2019Quote: The concentration of the core BBSome as derived from chemical crosslinking was adjusted to 0.05-0.08 mg/ml and 4 μl of sample was immediately applied to a glow-discharged UltrAuFoil® R1.2/1.3 holey gold grid (Quantifoil). After two minutes incubation at 13 °C and 100% relative humidity (RH) ...
-
bioRxiv - Microbiology 2022Quote: ... A 4□μl volume of SsoCsm complex was applied to holey carbon grids (Quantifoil Cu R1.2/1.3, 300 mesh) covered by a graphene oxide layer (27) ...
-
bioRxiv - Immunology 2024Quote: ... 3 µL aliquots were applied to UltrAuFoil gold R0.6/1 grids (Quantifoil) and subsequently blotted for 6 seconds at blot force 0 ...
-
bioRxiv - Molecular Biology 2021Quote: ... and applied onto freshly glow-discharged 200 square mesh Ultrafoil R2/2 gold grids (Quantifoil). The samples were plunge-frozen with a FEI Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Microbiology 2021Quote: ... Freshly glow-discharged finder gold quantifoil grids (200 mesh R2/2 – Quantifoil MicroTools GmbH, Germany) were sterilized in 70% EtOH and placed in a glass-bottomed MatTek dish (MatTek Corporation ...
-
bioRxiv - Microbiology 2021Quote: ... were applied to freshly washed and glow-discharged R2/2 holey carbon copper grids (Quantifoil). The grids were manually back blotted for 2 to 3s with filter paper ...
-
bioRxiv - Biochemistry 2021Quote: ... Cryo-EM grids were prepared using glow discharged R2/2 Cu 200 mesh grids (Quantifoil) pre-floated onto custom-made 2.9 nm continuous carbon film ...
-
bioRxiv - Molecular Biology 2023Quote: ... 3.5 μL) were applied to precoated (2 nm) R1.2/1.3 carbon-supported copper grids (Quantifoil), blotted for 4-5 s at 4°C ...
-
bioRxiv - Biochemistry 2023Quote: ... A sample of 3.0 μM of FH2 and 10.6 μM of actin monomers was applied to holey grids without a carbon film (Quantifoil Au 2/1 300 mesh from EMS). After diluting 4-fold ...
-
bioRxiv - Plant Biology 2022Quote: ... then 4 µl of the sample was applied to glow-discharged holey carbon grids (Quantifoil Cu R1.2/1.3, 300 mesh). The grid was blotted for 4s and then plunged into liquid ethane using a Vitrobot Mark IV (FEI ...
-
bioRxiv - Molecular Biology 2023Quote: 1.8 × 105 A549 or A549-IFITM3 cells were seeded on glow-discharged 200 mesh gold grids with a holey SiO2 film with R1/4 spacing (Quantifoil) placed in a 35 mm dish and cultured in 2 ml complete growth medium (DMEM-F12 ...
-
bioRxiv - Biochemistry 2023Quote: ... 4 μL of Fcμ–J–CD5L was applied to glow-discharged holy-carbon gold grids (Quantifoil, R1.2/1.3, 300 mesh), blotted with filter paper in 100% humidity at 4 °C ...
-
bioRxiv - Cell Biology 2024Quote: ... 4 μl of the cell suspension was applied onto a glow-discharged holey SiO2 grid (R1/4, Au, 200 mesh, Quantifoil) mounted on in the plunger chamber ...
-
bioRxiv - Microbiology 2021Quote: ... 3μl was added to a glow-discharged R2/2 200 mesh holey carbon EM grid (Quantifoil) for 30 seconds and the sample was blotted for 1 second ...
-
bioRxiv - Cell Biology 2022Quote: ... A volume of 2.5 μL was applied on glow-discharged UltrAuFoil Au200 R2/2 grids (Quantifoil), and excess liquid was removed by blotting for 3 s (blot force 5 ...
-
bioRxiv - Molecular Biology 2023Quote: ... Quantifoil R1.2/1.3 400-square mesh copper grids with a 2 nm continuous carbon layer (Quantifoil) were plasma-treated in a Pelco easiGlow glow discharging system (Ted Pella ...
-
bioRxiv - Biochemistry 2023Quote: The final high resolution data set was collected across 2 grids (Quantifoil 1.2/1.3 200 mesh) prepared with 1.8 mg mL-1 trimeric complex and 0.5 and 0.1 X CMC CHAPS ...
-
bioRxiv - Microbiology 2021Quote: ... Aliquots (4 μL) of the protein complex were placed on glow-discharged holey carbon grids (Quantifoil Au R1.2/1.3, 300 mesh). The grids were blotted and flash-frozen in liquid ethane cooled by liquid nitrogen with a Vitrobot apparatus (Mark IV ...
-
bioRxiv - Microbiology 2020Quote: Three μl of purified HKU1 HE (4 mg/ml) was dispensed on Quantifoil R1.2/1.3 200-mesh grids (Quantifoil Micro Tools GmbH) that had been freshly glow discharged for 30 seconds at 20 mA using GloQube Glow Discharge system (Quorum Technologies) ...
-
bioRxiv - Molecular Biology 2022Quote: ... 4 μL of protein samples were immediately applied to discharged 300-mesh Au R1.2/1.3 grids (Quantifoil, Micro Tools GmbH, Germany). Grids were blotted for 4 s and plunged into liquid ethane using an FEI Mark IV Vitrobot operated at 8°C and 100% humidity ...
-
bioRxiv - Cell Biology 2023Quote: ... 4 μl of the sample was applied to glow discharged holey carbon-coated 200 mesh copper EM grids (Quantifoil Micro Tools), vitrified as above at 4°C and 100 % humidity.
-
bioRxiv - Biochemistry 2021Quote: Three microliters of the h20S-PA26E102A-Opt5 solution were applied to R2/2 400-mesh grids (Quantifoil) that had been plasma treated for 25 s using a glow discharger (Electron Microscopy Sciences ...
-
bioRxiv - Molecular Biology 2022Quote: ... 3.5 μL was applied to freshly glow-discharged Quantifoil R2/2 300-square-mesh gold grids (Quantifoil) in a Vitrobot IV (ThermoFisher ...
-
bioRxiv - Biophysics 2020Quote: ... 2 μl apoferritin was applied to glow-discharged gold holey carbon 1.2/1.3 300-mesh grids (Quantifoil). Grids were blotted for 4 seconds at -2 force and vitrified in liquid ethane using a MarkIV Vitrobot (ThermoFisher) ...
-
bioRxiv - Molecular Biology 2023Quote: ... 3.5 μL was applied to freshly glow discharged Quantifoil R2/2 300-square-mesh gold grids (Quantifoil) in a Vitrobot IV (ThermoFisher ...
-
bioRxiv - Microbiology 2023Quote: ... The samples were applied to a Quantifoil R2/2 Cu 300 mesh grid (Quantifoil Micro Tools GmbH), which had been freshly glow-discharged for 60 s at 10 mA using PIB-10 (Vacuum Device) ...
-
bioRxiv - Biochemistry 2022Quote: ... 3 μL of sample was applied to 200-mesh copper R2/1 grids (Quantifoil), which were glow-discharged twice using a Pelco EasyGlow instrument ...
-
bioRxiv - Molecular Biology 2022Quote: ... 3 μl sample was applied to 1.2/1.3 or 0.6/1 UltrAuFoil grids (Quantifoil) (Russo and Passmore ...
-
bioRxiv - Biophysics 2023Quote: 3 μL of sample was applied on glow-discharged Au200 R2/1 grids (Quantifoil), and the excess liquid was removed by blotting for 4 s (blot force 3 ...
-
bioRxiv - Biochemistry 2022Quote: Grids (Quantifoil R3/3 Cu300 with 3 nm holey carbon) were glow discharged and 4 µL of sample (8 OD260/mL ...
-
bioRxiv - Neuroscience 2020Quote: ... 3.5 uL of sample was applied at a concentration of 3-5 mg/mL to glow-discharged holey carbon grids (Quantifoil R1.2/1.3). The grids were blotted using an FEI Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Molecular Biology 2021Quote: ... bremelanotide– or THIQ–bound MC4R–Gs complexes at ∼ 4 mg/mL were applied onto glow-discharged holey carbon grids (Quantifoil R1.2/1.3). Excess samples were blotted away and the grids were vitrified by plunging into liquid ethane using a Vitrobot Mark IV (ThermoFischer Scientific).
-
bioRxiv - Genomics 2020Quote: ... Vitrified specimens were prepared by adding 4 μl disome samples at the concentration of ~ 150 nM to a glow-discharged holey carbon grid (Quantifoil R1.2/1.3), which was covered with a freshly made thin carbon film ...
-
bioRxiv - Cell Biology 2020Quote: ... The MEFs were applied onto glow-discharged EM grids with a silicon-oxide support film (R1/4, Au mesh; Quantifoil, Jena, Germany). After incubation ...
-
bioRxiv - Molecular Biology 2019Quote: 4 µL of 0.06 mg/mL crosslinked complex were applied to glow-discharged holey carbon grids (Quantifoil, QF 1.2/1.3, 300 mesh) covered with a 2 nm carbon layer ...
-
bioRxiv - Cell Biology 2023Quote: ... Four µL of the cells were subsequently deposited onto Quantifoil R2/4 200 mesh copper grids (Quantifoil Micro Tools GmbH, Jena, Germany), which were then manually blotted from the back with Whatman® Grade 1 filter paper for approximately 3 – 5 seconds ...
-
bioRxiv - Biophysics 2023Quote: ... 4 μl suspended cells were loaded onto the front side of glow-discharged holy-carbon copper grids (Quantifoil R1.2/1.3, 200 mesh), and 2 μl medium was subsequently added to the back side of the grids ...
-
bioRxiv - Biophysics 2023Quote: ... Aliquots of 4 μl of protein samples (0.3 mg ml-1 or ∼6 μM) were applied to glow-discharged R1.2/1.3 200 Cu mesh grids (Quantifoil). After 30 s ...
-
bioRxiv - Biochemistry 2020Quote: ... and 2 µL sample was applied to glow-discharged gold holey carbon 1.2/1.3 300-mesh grids (Quantifoil) coated in-house with graphene oxide55-57 ...
-
bioRxiv - Biochemistry 2021Quote: ... A volume of 2.5 μL of each sample was applied on glow-discharged UltrAuFoil Au300 Rl.2/1.3 grids (Quantifoil), and excess liquid was removed by blotting for 3 s (blot force 5 ...
-
bioRxiv - Biochemistry 2022Quote: ... 2 μl retromer at a concentration between 80-100 μg/ml was applied to freshly glow discharged CF-2/2-2C C-Flat grids (Protochips, Morrisville, NC) or Quantifoil R 1.2/1.3 300 mesh copper grids (Quantifoil Micro Tools GmbH ...
-
bioRxiv - Microbiology 2022Quote: ... 3.5 μL of cell suspension was applied on glow-discharged copper or gold EM grids (R2/2, Quantifoil) and automatically back-blotted (Weiss et al 2017 ...
-
bioRxiv - Molecular Biology 2019Quote: ... 3 μl of the sample at 2 mg/ml were applied to 300 mesh UltrAuFoil Holey Gold Films R1.2/1.3 (Quantifoil) that had been previously plasma cleaned in a 75% argon / 25% oxygen atmosphere at 15 Watts for 6 seconds using a Solarus plasma cleaner (Gatan ...
-
bioRxiv - Evolutionary Biology 2021Quote: Molybdenum R1.2/1.3 and R2/2 200-mesh grids with a holey carbon support film (Quantifoil, Jena, DE) were glow discharged for 40 s under high vacuum shortly before sample application ...
-
bioRxiv - Biochemistry 2021Quote: ... 2 uL of crystal slurry was applied to each side of a glow-discharged holey carbon grid (Quantifoil, R 2/1 200 mesh Cu ...