Labshake search
Citations for Quantifoil Micro Tools :
701 - 730 of 730 citations for 5 Pyrimidinecarbonitrile 1 2R 2 3 dihydroxypropyl 1 2 3 4 tetrahydro 3 methyl 2 4 dioxo 9CI since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
Cryo-EM structure of a eukaryotic zinc transporter at a low pH suggests its Zn2+-releasing mechanismbioRxiv - Biochemistry 2022Quote: ... and 3 μl of the protein solution was applied to glow-discharged (45 s) Quantifoil R2/1 300-mesh gold grids (Quantifoil Micro Tools GmbH, Germany). The grids were blotted with standard Vitrobot filter paper for 2.5 s at 4 °C under 100% humidity and plunged into liquid ethane using a Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Bioengineering 2023Quote: ... 3.0 µl aliquots at a concentration of 0.87 or 1.0 mg/ml of the spikeD614G-binder sample or the spikeOmicron-binder sample were applied onto glow-discharged carbon-coated copper grids (Quantifoil R2/1, 400 mesh), blotted for 4.0-8.0 s ...
-
bioRxiv - Biochemistry 2023Quote: ... 3 μl of protein at a concentration of approximately 10 mg ml−1 were loaded onto glow-discharged holey carbon grids (Quantifoil Au 300 mesh R1.2/1.3 or Quantifoil Cu/Rh 300 mesh R1.2/1.3), after which ...
-
bioRxiv - Cell Biology 2022Quote: ... 3 μL of ∼100 nM (A260 4.0 or 6.0) mitoribosome sample was applied onto a glow-discharged (20 mA for 30 sec) holey-carbon grid (Quantifoil R2/1 copper, mesh 300) coated with continuous carbon (of ∼3 nm thickness ...
-
bioRxiv - Biochemistry 2024Quote: ... Approximately 3.5 μl of the solution was applied onto freshly glow-discharged and graphene oxide-coated TEM grids (Quantifoil R2/1, Cu 200 mesh) and plunge-frozen into liquid ethane by a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Biophysics 2021Quote: ... 2.8 ul of the mixture was applied onto glow discharged (5 mA, 20 sec) R1.2/1.3 holey carbon gold grids (300 mesh, Quantifoil) at 22°C and 100% humidity ...
-
bioRxiv - Microbiology 2023Quote: Four microliters of purified TilA-TslA-TlaA1-TlaA2 complex at 0.5 mg ml-1 in Buffer B (Supplementary Table 5) was applied onto glow-discharged (60 s, 30 mA) 300 mesh R1.2/1.3 Au grids (Quantifoil). Grids were blotted for 3 s with blot force of +15 at 10°C and 100% humidity ...
-
bioRxiv - Biochemistry 2023Quote: A 3.5 μL concentrated SPARTA sample was loaded onto a glow discharged UltrAuFoil 300 mesh R1.2/1.3 grids (Quantifoil) using a FEI Vitrobot at 4°C and 100% humidity ...
-
bioRxiv - Microbiology 2023Quote: ... 2.2µl of the purified mixture at a concentration of 0.5 mg/mL was applied to glow discharged (30 s at 25mA) grid (300 mesh 1.2/1.3, Quantifoil). The grids were blotted for 3.5 s before plunging into liquid ethane using Vitrobot MK4 (TFS ...
-
bioRxiv - Biophysics 2020Quote: Three microliters of the apoferritin samples with 1.5 mg/ml or 0.2 mg/ml were applied onto glow-discharged 200-mesh R2/1 Quantifoil grids (used for the K3 dataset) or 200-mesh R2/1 Quantifoil grids coated with continuous carbon film (Quantifoil, used for the Falcon4 dataset), respectively ...
-
bioRxiv - Biophysics 2019Quote: ... 3.5 μl aliquots of the recombinant human TIM22 complex (7 mg ml-1) were dropped onto glow discharged holey carbon grids (Quantifoil Au R1.2/1.3, 300 mesh), blotted with a Vitrobot Mark IV (ThemoFisher Scientific ...
-
bioRxiv - Physiology 2021Quote: ... Aliquots of 1.25 – 1.5 μl RyR1-Nanodisc were applied onto each side of glow-discharged UltraAufoil −1.2/1.3 holey-gold (Quantifoil, Germany) with 300 TEM mesh ...
-
bioRxiv - Cell Biology 2019Quote: ... Liquid culture (5 μL, ~1000 cells/μL) was blotted onto carbon-coated 200-mesh copper grids (Quantifoil Micro Tools), which were then plunged into a liquid ethane-propane mixture using a Vitrobot Mark 4 (FEI Thermo Fisher) ...
-
bioRxiv - Biochemistry 2021Quote: ... 3.5 μl of the freshly purified sample from the peak fraction in DDM at ~2.0 mg/ml for the B.1.1.7 protein or ~1.5 mg/ml for the B.1.351 protein was applied to a 1.2/1.3 Quantifoil grid (Quantifoil Micro Tools GmbH), which had been glow discharged with a PELCO easiGlow™ Glow Discharge Cleaning system (Ted Pella ...
-
bioRxiv - Cell Biology 2023Quote: ... and 5% (w/v) glycerol was applied to a Quantifoil 300-mesh R1.2/1.3 grid (Quantifoil, Micro Tools GmbH, Germany), which had been pre-treated with glow discharge using Pelco EasiGlow immediately before use ...
-
bioRxiv - Biophysics 2023Quote: 3.5 µL of protein or lipid solution was applied onto a freshly glow-discharged carbon-coated copper mesh grid (Quantifoil). After 1 min ...
-
bioRxiv - Biochemistry 2023Quote: 3.5 µL of sample were applied to a freshly glow discharged 200-mesh Au R1.2/1.3 grid (Quantifoil Micro Tools), incubated for 5 s ...
-
bioRxiv - Microbiology 2024Quote: The total 2.5 µL sample was applied to both sides of glow-discharged 400-mesh R1.2/1.3 Cu grids (Quantifoil, Jena, Germany). The grids were blotted for 14 s at a humidity of 100% at 8 °C and rapidly frozen in liquid ethane using a Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Microbiology 2019Quote: ... 5 µl of purified pelleted EVs in HBSS were applied to carbon-coated copper grids (R1.2/1.3, Quantifoil Micro Tools GmbH) and the excess of liquid was blotted automatically for two seconds from the reverse side of the grid with a strip of filter paper ...
-
bioRxiv - Biophysics 2019Quote: 3 µL of purified aldolase (1.6 mg/mL) or apoferritin (5 mg/mL) was dispensed on UltrAuFoil R1.2/1.3 300-mesh grids (Quantifoil Micro Tools GmbH) that had been freshly plasma cleaned for six seconds at 15Watts (75% nitrogen/25% oxygen atmosphere ...
-
bioRxiv - Biochemistry 2023Quote: 3 μl of 50 μM purified insulin in 20 mM sodium phosphate buffer containing (pH 7.5) containing 100 mM NaCl was applied onto a grow discharged Quantifoil R1.2/1.3 Cu 200 grid (Quantifoil Micro Tool GmbH) and subsequently blotted by filter papers and plunged into liquid ethane for the vitrification using a Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Biophysics 2021Quote: ... 3.5 µl sample applied to a glow-discharged Quantifoil R1.2/1.3 400-mesh gold holey carbon grid (Quantifoil, Micro Tools GmbH, Germany), blotted under 100% humidity at 4 °C and plunged into liquid ethane using a Mark IV Vitrobot (FEI) ...
-
bioRxiv - Microbiology 2021Quote: A 2.5-ml suspension of the purified medusavirus particles was applied to a quantifoil grid (R1.2/1.3 Mo) (Quantifoil Micro Tools GmbH, Germany), which was glow-discharged beforehand for 30 s ...
-
bioRxiv - Cell Biology 2022Quote: ... 3.5 µL of sample were applied to glow discharged (45s 30 mA) 1.2/1.3 Ultrafoil holey grids (Quantifoil Micro Tools GmbH, Germany) and they were plunged frozen in liquid ethane with a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Biophysics 2021Quote: ... 3.5 μL sample with addition of 0.05% β-OG was directly applied to glow-discharged 200 mesh gold grids (Quantifoil R1.2/1.3) and vitrified using a FEI Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Biochemistry 2022Quote: ... or AE1-Niflumic acid at 5 mg/ml were applied to glow-discharged holey carbon EM grids (Quantifoil 300 copper mesh, R1.2/1.3) in an EM-GP2 plunge freezer (Leica) ...
-
bioRxiv - Biochemistry 2021Quote: ... 3 μL of protein solution at 5 mg/mL (with 0.025% DDM) was applied onto a glow-discharged holey carbon grid (Quantifoil, 300 mesh, R1.2/1.3). Excess samples were blotted for 5.0 s with a blotting force of 3 ...
-
bioRxiv - Biophysics 2021Quote: ... 2.5 μL of each purified CCKAR–G protein complex was applied individually onto the glow-discharged holey carbon grids (Quantifoil, Au300 R1.2/1.3) in a Vitrobot chamber (FEI Vitrobot Mark IV) ...
-
bioRxiv - Biophysics 2021Quote: ... 3 μL of the purified lasmiditan–5-HT1F–Gi complex at concentration ∼15 mg/ml were applied onto a glow-discharged holey carbon grid (Quantifoil R1.2/1.3 Au 300). Grids were plunge-frozen in liquid ethane using Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Biophysics 2023Quote: ... 3 μL of purified mGlu5 (with the different ligands) at 5 mg/ml was applied on glow-discharged holey carbon gold grids (Quantifoil R1.2/1.3, 200 mesh). The grids were blotted using a Vitrobot Mark IV (FEI ...