Labshake search
Citations for Quantifoil Micro Tools :
401 - 450 of 730 citations for 7 Chloro 1 3 dihydro 5 phenyl 2H 1 4 benzodiazepin 2 thione since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2021Quote: ... 1 mM TCEP and adsorbed to glow-discharged holey carbon-coated grids (Quantifoil 300 mesh, Au R1.2/1.3) for 10 s ...
-
bioRxiv - Microbiology 2020Quote: ... Five microliters of cell suspension were deposited on holey carbon electron microscopy grids (200 mesh, R2/1, Quantifoil), which had been freshly glow-discharged for ∼30 seconds ...
-
bioRxiv - Immunology 2021Quote: ... The resulting EV suspension was spotted onto a glow discharged holey carbon mesh copper grids (Quantifoil, R2/1) and incubated at room temperature for 4 mins 45 seconds before 5μL of 0.22μm filtered 2% (v/v ...
-
bioRxiv - Microbiology 2022Quote: Cryo-ET samples were prepared using copper grids with holey carbon support film (200 mesh, R2/1, Quantifoil). The grids were glow-discharged for ∼30 s before depositing 5 µl of cell solution onto them ...
-
bioRxiv - Molecular Biology 2023Quote: ... 1.5 µL of fibril solution was applied to freshly glow-discharged R2/1 holey carbon film grids (Quantifoil). After the grids were blotted for 12 seconds at a blot force of 10 ...
-
bioRxiv - Biophysics 2023Quote: ... Aliquots of 4 μl of protein samples (0.3 mg ml-1 or ∼6 μM) were applied to glow-discharged R1.2/1.3 200 Cu mesh grids (Quantifoil). After 30 s ...
-
bioRxiv - Biochemistry 2023Quote: ... 3.5 μL of HTNV-L at 1 µM was deposited on glow-discharged (25 mA, 45 s) UltraAuFoil 300 mesh R1.2/1.3 grids (Quantifoil). The grid was blotted for 3s (blot force 1 ...
-
bioRxiv - Biophysics 2023Quote: Three microliters of the purified CLC-2 or CLC-2/AK-42 mixture was applied to glow-discharged copper Quantifoil R1.2/1.3 or R2/1 holey carbon grids (Quantifoil). Grids were incubated for 15 s ...
-
bioRxiv - Biophysics 2020Quote: Quantifoil grids (200 mesh Au R2/2 and Au Finder; Quantifoil Micro Tools GmbH ...
-
bioRxiv - Microbiology 2022Quote: ... EM grids (R2/2, Cu 200 mesh; Quantifoil Micro Tools GmbH) were glow-discharged for 45 sec at 25 mA by PELCO easiGlow discharger ...
-
bioRxiv - Molecular Biology 2021Quote: ... UltrAuFoil (Russo and Passmore, 2014) R2/2 200 mesh grids (Quantifoil) were glow discharged for 15 s at 30 mA in a Quorum SC7620 ...
-
bioRxiv - Microbiology 2022Quote: ... Gold quantifoil R2/2 200 mesh grids (Quantifoil Micro Tools GmbH) were sterilised with 70% ethanol and placed in glass bottomed MatTek dishes (MatTek Corporation ...
-
bioRxiv - Biochemistry 2023Quote: ... Holey carbon R2/2 300 mesh grids (Quantifoil Micro Tools GmbH) were glow-discharged for 90 sec at 25 mA using a PELCO easiGlow glow discharge cleaning system ...
-
bioRxiv - Molecular Biology 2020Quote: 3 μL of sample was applied onto a holey carbon grid (Quantifoil, Cu, R1.2/1.3, 300 mesh) rendered hydrophilic by a 30 s glow-discharge in air (11 mA current with PIB-10) ...
-
bioRxiv - Plant Biology 2021Quote: Concentrated PSII solution (3 µl) was applied on glow-discharged holey carbon grids (Cu Quantifoil R1.2/1.3) that were vitrified for cryo-EM structural determination using a Vitrobot FEI (3 s blot at 4°C and 100% humidity) ...
-
bioRxiv - Molecular Biology 2022Quote: ... The sample (3 μL) was applied to freshly glow-discharged Au 300 mesh R1.2/1.3 grids (Quantifoil) in a Vitrobot Mark IV (FEI ...
-
bioRxiv - Biophysics 2021Quote: ... 3 μL was applied to Ultrafoil grids (R1.2/1.3, Au/Au, 300 mesh, Quantifoil Micro Tools GmbH) that had been glow-discharged for 2 min using a Pelco easiGlow (Ted Pella ...
-
bioRxiv - Pharmacology and Toxicology 2022Quote: Samples (3 µL) were applied to glow-discharged Quantifoil R1.2/1.3 Cu/Rh 200 mesh grids (Quantifoil) (M4R-Gi1-Ipx and M4R-Gi1-Ipx-LY298 ...
-
bioRxiv - Biophysics 2023Quote: ... 3 µL sample was applied to a freshly glow-discharged UltrAuFoil R1.2/1.3 300 mesh grids (Quantifoil), blotted with Whatman No ...
-
bioRxiv - Biochemistry 2023Quote: ... 3 μl diluted protein sample was put on freshly glow-discharged Quantifoil R1.2/1.3 Cu grid (Quantifoil Micro Tools GmbH ...
-
bioRxiv - Biochemistry 2023Quote: ... 4 μl of sample was applied to glow discharged Quantifoil 300 mesh 1.2/1.3 (Quantifoil) grids at 4 °C and 90-100% humidity ...
-
bioRxiv - Biophysics 2024Quote: ... 4 µl of this sample was then applied to plasma-cleaned holey carbon grids (Quantifoil) and plunge frozen with an FEI vitrobot mark IV at 4°C and 100% humidity.
-
bioRxiv - Microbiology 2020Quote: ... mobilis Zm4 or Zm6 cells were applied to glow-discharged holey carbon grids (Quantifoil R3.5/1 Cu 200-mesh) and plunge-frozen in liquid ethane using a Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Biophysics 2021Quote: ... A volume of 4 μL cell suspension at a concentration of 3.07-3.5×107 cells/ml was directly applied to glow-discharged holey carbon R2/1 Cu 200 mesh grids (Quantifoil). After 5 s back-side blotting ...
-
bioRxiv - Molecular Biology 2022Quote: ... 3 μL of sample were pipetted onto a freshly glow discharged (PELCO easiGlow, 25 mA, 45 sec) 300 mesh Cu 0.6/1 grid (Quantifoil) and blotted for 4 s at strength 4 ...
-
bioRxiv - Neuroscience 2023Quote: ... Double application of 3 µL protein (∼0.6 mg/mL) SYM2081 complex was carried out on glow-discharged gold grids (R 0.6/1, 300 mesh, Quantifoil). The grids were blotted for 4.5 s and 3.5 s ...
-
bioRxiv - Microbiology 2021Quote: ... 3 μl of each sample was dispensed on Quantifoil R1.2/1.3 200-mesh grids (Quantifoil Micro Tools GmbH) that had been freshly glow discharged for 30 seconds at 20 mA using a PELCO easyGLow™ Glow Discharge Cleaning System (Tedpella) ...
-
bioRxiv - Immunology 2022Quote: ... 3 μl of sample was then dispensed on Quantifoil R1.2/1.3 200-mesh grids (Quantifoil Micro Tools GmbH) that had been freshly glow discharged for 30 s at 20 mA ...
-
bioRxiv - Biochemistry 2022Quote: ... 3 µl of TIR-SAVED complex was applied to Holey Carbon grids (Quantifoil Cu R1.2/1.3, 300 mesh), glow discharged for 45 s at current of 45 mA in a EMITECH K100X glow discharger ...
-
bioRxiv - Molecular Biology 2020Quote: A 3 μL sample solution was applied to a Quantifoil holey carbon grid R1.2/1.3 Mo 200 mesh (Quantifoil Micro Tools GmbH ...
-
bioRxiv - Neuroscience 2021Quote: ... Aliquots of 3 μl were applied to glow-discharged holey carbon grids (Quantifoil Au R1.2/1.3, 300 mesh) and plunge-frozen in liquid ethane using a Thermo Fisher Vitrobot Mark IV ...
-
bioRxiv - Biochemistry 2021Quote: ... A 3-μl aliquot was pipetted on a holey carbon cryo-EM grid (1.3/1.2 Cu 200 mesh, Quantifoil) and vitrified by plunge-freezing in liquid ethane (Vitrobot Mark IV ...
-
bioRxiv - Microbiology 2019Quote: UNSW-2012 and CHDC-1974 VLPs (3 μl) were applied on freshly glow discharged Quantifoil holey carbon support films (R1.2/1.3; Quantifoil) and blotted for 18 seconds at 100% humidity at 10°C before been plunged in liquid ethane using an FEI Mark IV Vitrobot (Thermo Fischer Scientific) ...
-
bioRxiv - Immunology 2021Quote: ... 3 μl of sample was then dispensed on Quantifoil R1.2/1.3 200-mesh grids (Quantifoil Micro Tools GmbH) that had been freshly glow discharged for 30 s at 20 mA ...
-
bioRxiv - Biophysics 2021Quote: ... 3 μl sample was applied to each side of the UltrAuFoil grid (300 mesh, R 1.2/1.3, Quantifoil), which had been glow discharged on both sides (25 mA ...
-
bioRxiv - Molecular Biology 2022Quote: ... 4 µl of DELE WT CTD sample at 3 mg/ml was applied onto 300 mesh R1.2/1.3 UltraAuFoil holey gold grids (Quantifoil) that were plasma cleaned for 15 s using Pelco glow discharge cleaning system (Ted Pella ...
-
bioRxiv - Biophysics 2022Quote: ... A total of 3 µl of the solution was applied to freshly glow discharged R2.2 Cu300 grids (Quantifoil), blotted from the back side for 1.2s at 20°C and 99% humidity and immediately plunge frozen in liquid ethane using a Leica EM GP ...
-
bioRxiv - Biochemistry 2023Quote: ... Cryo-EM grids were prepared by pipetting 3 µl of sample on a R1.2/1.3 Cu 300 mesh grid (Quantifoil) and plunge-freezing in liquid ethane using a Vitrobot Mark IV (ThermoFisher).
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... 3 μl of the purified complex was applied to glow-discharged holey carbon grids (Quantifoil, Au300 R1.2/1.3). Grids were plunge-frozen in liquid ethane using Vitrobot Mark IV (Thermo Fischer Scientific).
-
bioRxiv - Biophysics 2023Quote: mGluR3 samples ranging from 2.0-4.7 mg/mL were applied at a volume of 3 μL to plasma treated UltrAuFoil 1.2/1.3 300 mesh grids (Quantifoil). Vitrified samples were prepared using a Vitrobot Mk IV (Thermo Fisher) ...
-
bioRxiv - Biophysics 2023Quote: ... 3 μL of sample was applied to a freshly glow-discharged UltrAuFoil R1.2/1.3 300 mesh grids (Quantifoil), blotted for 1.5 – 2.0 s ...
-
bioRxiv - Immunology 2023Quote: ... 3 μL of the purified complex (8 mg/ml) was deposited onto a glow-discharged holey grid (Quantifoil Au 300 mesh R1.2/1.3 ...
-
bioRxiv - Biochemistry 2023Quote: ... A sample volume of 3 μL sample was applied to a freshly glow-discharged UltrAuFoil R1.2/1.3 300 mesh (Quantifoil); the sample was incubated for 1min and blotted with Whatman No ...
-
bioRxiv - Bioengineering 2019Quote: ... 5 μl of the sample was placed on a carbon coated grid (Quantifoil, D) previously glow-discharged for 30 seconds (Emitech K100X ...
-
bioRxiv - Cell Biology 2020Quote: Either 200 mesh gold holey carbon grids (R2/2; Quantifoil Micro Tools) or 200 mesh gold grids (Science Services ...
-
bioRxiv - Microbiology 2022Quote: ... cells were seeded on R2/2 gold UltrAufoil grids (200 mesh, Quantifoil Micro Tools GmbH ...
-
bioRxiv - Molecular Biology 2020Quote: ... gold 300 mesh Quantifoil R2/2 holey carbon grids (Quantifoil Micro Tools) were glow discharged using an Edwards Sputter Coater 305B ...
-
bioRxiv - Biophysics 2022Quote: ... Quantifoil grids (200 mesh Au R2/2 carbon or SiO2 film; Quantifoil Micro Tools GmbH ...
-
bioRxiv - Neuroscience 2020Quote: ... electron microscopy (EM) gold finder grids (Quantifoil R2/2 Au NH2 grids) were plasma cleaned with H2 and O2 for 10 s using a plasma cleaning system (Gatan) ...
-
bioRxiv - Biochemistry 2022Quote: Quantifoil R2/2 Cu300 or Quantifoil R1.2/1.3 Cu300 (Quantifoil Micro Tools) grids were glow-discharged using the GloQube plasma cleaner (Quorum ...