Labshake search
Citations for Quantifoil Micro Tools :
201 - 250 of 405 citations for R 3 Amino 5 hexynoic acid hydrochloride since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Molecular Biology 2023Quote: ... Samples (3 μl) were applied to Quantifoil 2/1 Cu 300 holey-carbon grids (Quantifoil) glow-discharged 60 s using a PELCO glow-discharge system (Ted Pella) ...
-
bioRxiv - Microbiology 2023Quote: ... sample aliquots of 3 µL were applied onto UltrAuFoil R2/2 grids (300 mesh, Quantifoil). Grids were blotted for 1 s at 10°C with 100% relative humidity and immediately plunge frozen into liquid ethane using a Vitrobot Mark IV system (TFS) ...
-
bioRxiv - Molecular Biology 2022Quote: ... Samples (3 μl) were applied to Quantifoil 1.2/1.3 Cu 300 holey-carbon grids (Quantifoil) glow-discharged 60 s using a PELCO glow-discharge system (Ted Pella) ...
-
bioRxiv - Cell Biology 2022Quote: ... 3 μl of the resulting mixture was spotted onto glow-discharged copper EM grids (Quantifoil 300 Au mesh ...
-
bioRxiv - Molecular Biology 2024Quote: ... Samples (3 μl) were applied to 2/1 Quantifoil Cu 300 holey-carbon grids (Quantifoil); glow-discharged 60 s using a PELCO glow-discharge system (Ted Pella)]) ...
-
bioRxiv - Biochemistry 2024Quote: ... 3 μL samples were applied to the discharged UltrAuFoil R1.2/1.3 gold 300 mesh (Quantifoil). Grids were blotted for 3 sec and plunged into liquid ethane at 100% humidity at 8 °C ...
-
bioRxiv - Biophysics 2024Quote: ... and 3 µL were applied to glow-discharged R2/2 holey carbon copper grids (Quantifoil). These grids were manually back blotted for 2 to 3s with filter paper ...
-
bioRxiv - Microbiology 2020Quote: ... 3.5 μl of cell suspension from 80-100 μl of final volume were applied on glow discharged 200-mesh EM copper grids coated with R 2/1 holey SiO2 films (Quantifoil Micro Tool GmbH) and plunge frozen in liquid ethane at ~−184°C using a Leica EM GP grid plunger ...
-
bioRxiv - Biophysics 2020Quote: ... 3.5ul of cell suspension were applied on 200-mesh copper grids coated with R 2/1 holey carbon or SiO2 films (Quantifoil Micro Tools GmbH) and plunge frozen in liquid ethane at ~-186°C using a Leica EM GP grid plunger ...
-
bioRxiv - Biophysics 2020Quote: The cell suspension in sea water was seeded onto R 2/2 (SiO2) on Au G200F1 finder grids (Quantifoil Micro Tools GmbH, Germany) and incubated with filtered fresh sea water at 18 °C overnight ...
-
bioRxiv - Biochemistry 2022Quote: ... Qualified nucleosomes were then loaded in a freshly glow discharged holey carbon golden grid (Quantifoil™ R 2/2 on 300 gold mesh) (1.0-2.5 µg of nucleosomes were diluted in 40 mM NaCl reconstitution buffer in 3 μL) ...
-
bioRxiv - Molecular Biology 2023Quote: ... The complex was incubated at RT for 20 mins and pipetted onto glowed discharged cryo-EM grids (Quantifoil R 2/2 Au 300). Grids were frozen in liquid ethane by using a Vitrobot Mark IV (ThermoFischer ...
-
bioRxiv - Biophysics 2024Quote: ... 4 × 104 MDM were seeded on glow discharged and UV-light sterilized 200-mesh EM gold grids coated with R 2/2 holey carbon films (Quantifoil Micro Tool GmbH), which were placed in a glass-bottomed ‘microwell’ of 35-mm MatTek dish (MatTek ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... were applied to glow-discharged (25 mA, 10 s) QuantiFoil Gold R 0.6/1 300-mesh holey carbon grids (QuantiFoil, Micro Tools GmbH, Germany), blotted for 4.5 s ...
-
bioRxiv - Physiology 2021Quote: ... 3 µL of the vortexed dispersion were placed on glow discharged carbon-coated grids (Quantifoil, D) for 1 minute ...
-
bioRxiv - Biochemistry 2022Quote: ... 3 µL of purified PPSA was applied to glow-discharged holy grids (Quantifoil, Cu200, R2/2) for 30s ...
-
bioRxiv - Plant Biology 2023Quote: ... 3 μl protein was applied to glow-discharged carbon grids (Quantifoil Cu R1.2/1.3 300 mesh). Subsequently ...
-
bioRxiv - Biophysics 2023Quote: ... 3 μl of the sample was applied to a hydrophilized grids (Quantifoil, R1.2/1.3+2nm carbon) with an additional 2 nm layer of amorphous carbon ...
-
bioRxiv - Biophysics 2024Quote: ... 3 μl sample were applied individually to electron microscopy grids (Quantifoil, 400 mesh Au 1.2/1.3) that were glow discharged for 40 s using Gatan SOLARUS ...
-
bioRxiv - Biochemistry 2024Quote: ... 3 µL of the samples were applied to a holey carbon R3.5/1 Cu200 grid (Quantifoil) covered with a 2 nm continuous carbon foil ...
-
bioRxiv - Biophysics 2024Quote: ... 3 ul sample was applied onto glow-discharged R1.2/1.3 300 mesh UltrAuFoil gold grids (Quantifoil) (Russo and Passmore ...
-
bioRxiv - Biophysics 2024Quote: ... 3 µl of the solution was then added to a glow- discharged ultrafoil gold grid (Quantifoil 2/2 ...
-
bioRxiv - Biochemistry 2021Quote: ... 3 μL of the ATP13A2 sample were applied to a glow-discharged (PELCO easiGlow; 0.39 mBar, 25–30 mA, 40–45 s) gold holey carbon grid (Quantifoil R 1.2/1.3, 400 mesh). The grid was blotted for 3–4 s and plunge-frozen in liquid-nitrogen-cooled liquid ethane using Vitrobot Mark IV (FEI ...
-
bioRxiv - Biophysics 2020Quote: Samples were prepared for CryoEM by applying 5 μl freshly purified Cx46/50-lipid nanodisc complex (∼2.5 mg mL-1) to a glow-discharged holey carbon grid (Quantifoil R 1.2/1.3, 400 mesh) for 10 seconds ...
-
bioRxiv - Immunology 2020Quote: ... 3 μL of the complex was mixed with 1 μL of a n-Dodecyl-β-D-Maltopyranoside (DDM) solution to a final DDM concentration of 0.06 mM and applied to a grid (Quantifoil R 1.2/1.3, 400), which had been plasma-cleaned for 5 seconds using a mixture of N2/O2 (Gatan Solarus 950 Plasma system) ...
-
bioRxiv - Microbiology 2024Quote: ... 3 μL of purified viral particles at ∼1 mg/mL were applied during 2 min to glow-discharged Quantifoil R 2/2 grids covered with a thin carbon film (Quantifoil Micro tools GmbH, Germany), blotted for 3 s and then flash frozen in liquid ethane using the semi-automated plunge freezing device Vitrobot IV at 100% relative humidity ...
-
bioRxiv - Biophysics 2024Quote: ... 2 μL of 2 μM taxol-microtubules were incubated on a glow-discharged holey carbon cryo-EM grid (QuantiFoil, Cu 300 R 2/1) for 30 seconds ...
-
bioRxiv - Biophysics 2024Quote: ... 2 μL of 2 μM taxol-microtubules were incubated on a glow-discharged holey carbon cryo-EM grid (QuantiFoil, Au 300 R 1.2/1.3) for 30 seconds ...
-
bioRxiv - Biochemistry 2024Quote: IN-IBD complex (0.1 mg/mL) was applied onto freshly plasma cleaned (20s, Solarus plasma cleaner) holey grids (Quantifoil UltrAufoil R 1.2/1.3 300 mesh) at 4°C in the cold room with ∼90% humidity ...
-
bioRxiv - Biophysics 2024Quote: ... to produce a fiducial marker along with 0.01% NP-40 and 10 μM tubulin solution with BRB80 buffer and 1 mM GTP before the solution was dropped onto the grids (QUANTIFOIL R 1.2/1.3 Cu 200). The grids were blotted with vitrobot (Thermo Fisher Scientific ...
-
bioRxiv - Molecular Biology 2020Quote: 3 μL of sample was applied onto a holey carbon grid (Quantifoil, Cu, R1.2/1.3, 300 mesh) rendered hydrophilic by a 30 s glow-discharge in air (11 mA current with PIB-10) ...
-
bioRxiv - Plant Biology 2021Quote: Concentrated PSII solution (3 µl) was applied on glow-discharged holey carbon grids (Cu Quantifoil R1.2/1.3) that were vitrified for cryo-EM structural determination using a Vitrobot FEI (3 s blot at 4°C and 100% humidity) ...
-
bioRxiv - Molecular Biology 2022Quote: ... The sample (3 μL) was applied to freshly glow-discharged Au 300 mesh R1.2/1.3 grids (Quantifoil) in a Vitrobot Mark IV (FEI ...
-
bioRxiv - Biophysics 2021Quote: ... 3 μL was applied to Ultrafoil grids (R1.2/1.3, Au/Au, 300 mesh, Quantifoil Micro Tools GmbH) that had been glow-discharged for 2 min using a Pelco easiGlow (Ted Pella ...
-
bioRxiv - Biochemistry 2023Quote: ... 3 μl diluted protein sample was put on freshly glow-discharged Quantifoil R1.2/1.3 Cu grid (Quantifoil Micro Tools GmbH ...
-
bioRxiv - Biochemistry 2023Quote: ... by applying 3 μL of it to plasma-cleaned 0.6/1 μm holey gold UltrAuFoil grids (Quantifoil). Following a 30 s incubation ...
-
bioRxiv - Pharmacology and Toxicology 2022Quote: Samples (3 µL) were applied to glow-discharged Quantifoil R1.2/1.3 Cu/Rh 200 mesh grids (Quantifoil) (M4R-Gi1-Ipx and M4R-Gi1-Ipx-LY298 ...
-
bioRxiv - Biophysics 2023Quote: ... 3 µL sample was applied to a freshly glow-discharged UltrAuFoil R1.2/1.3 300 mesh grids (Quantifoil), blotted with Whatman No ...
-
bioRxiv - Immunology 2023Quote: ... Then 3 μl of the mixture was applied to a Quantifoil-Au-2/1-3C grid (Quantifoil) pretreated by glow-discharging at 20 mA for 1 min ...
-
bioRxiv - Microbiology 2024Quote: ... 3 μL of sample was loaded onto glow discharged holey carbon grids (Quantifoil, 300 mesh, R1/2). Samples were blotted for 3s and plunge frozen in liquid ethane using a Leica EM GP2 to obtain vitrified ice for imaging ...
-
bioRxiv - Biochemistry 2024Quote: Ternary complex sEGFR-Ex3HL/LH-CD3γε (3 µL) was applied to Quantifoil R1.2/1.3 Cu girds (Quantifoil) that had been glow discharged at 10 mA for 40 seconds with a sputter coater (JEOL JEC-3000FC) ...
-
bioRxiv - Biophysics 2024Quote: ... 3 μL were adsorbed to glow-discharged holey carbon-coated grids (Quantifoil 300 mesh, Cu R1.2/1.3). were then blotted for 3 to 6 s at 100% humidity (4 °C ...
-
bioRxiv - Biochemistry 2024Quote: ... 3 μL of alpha synuclein fibrils were applied to the glow-discharged holey carbon Cu grids (Quantifoil) and blotted with filter paper using Vitrobot Mark IV (FEI Company) ...
-
bioRxiv - Bioengineering 2024Quote: ... 5 µl of protein complex was deposited on a holey copper grid (QUANTIFOIL R1.2/1.3 ...
-
bioRxiv - Biophysics 2021Quote: ... of purified CtenDNAV-II virons (10 mg ml-1) was deposited onto freshly glow-discharged holey carbon-coated copper grids (Quantifoil R 2/2, 300 mesh, copper) followed by 2 s of blotting in 100% relative humidity for plunge-freezing (Vitrobot Mark IV ...
-
bioRxiv - Microbiology 2021Quote: ... 3 μl of each sample was dispensed on Quantifoil R1.2/1.3 200-mesh grids (Quantifoil Micro Tools GmbH) that had been freshly glow discharged for 30 seconds at 20 mA using a PELCO easyGLow™ Glow Discharge Cleaning System (Tedpella) ...
-
bioRxiv - Immunology 2022Quote: ... 3 μl of sample was then dispensed on Quantifoil R1.2/1.3 200-mesh grids (Quantifoil Micro Tools GmbH) that had been freshly glow discharged for 30 s at 20 mA ...
-
bioRxiv - Biochemistry 2022Quote: ... 3 µl of TIR-SAVED complex was applied to Holey Carbon grids (Quantifoil Cu R1.2/1.3, 300 mesh), glow discharged for 45 s at current of 45 mA in a EMITECH K100X glow discharger ...
-
bioRxiv - Biochemistry 2022Quote: ... 3 μl of sample were applied onto a freshly glow-discharged copper R2/1 300 mesh grid (Quantifoil), blotted for 8 s on both sides with blotting force −15 and plunge-frozen in liquid ethane.
-