Labshake search
Citations for Quantifoil Micro Tools :
1 - 50 of 405 citations for R 3 Amino 5 hexynoic acid hydrochloride since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Immunology 2023Quote: ... respectively) and 3 μl were kept 5 min at RT until their application onto glow-discharged holey carbon grids (Quantifoil, Au 300 mesh, R 0.6/1). The grids were blotted and then plunged into liquid ethane using a FEI Vitrobot Mark IV at 20°C and 95% relative humidity ...
-
bioRxiv - Cell Biology 2021Quote: 3 mm gold EM grids with a holey carbon film (R 2/2, 200 mesh; Quantifoil Cat no ...
-
bioRxiv - Biochemistry 2024Quote: ... 3 µL of purified protein was applied to an UltrAuFoil® R 1.2/1.3 grid (Quantifoil) that had been glow-discharged for 1 minute and 45 seconds ...
-
bioRxiv - Molecular Biology 2022Quote: ... 3 μl of protein sample was applied to holey carbon grids (Quantifoil, R 0.6/1 Cu 200 mesh) which were H2/O2 glow-discharged for 30 s ...
-
bioRxiv - Biophysics 2021Quote: ... 3 μl sample was applied to each side of the UltrAuFoil grid (300 mesh, R 1.2/1.3, Quantifoil), which had been glow discharged on both sides (25 mA ...
-
bioRxiv - Cell Biology 2022Quote: Vero-E6 were seeded on holey carbon film R 5/20 gold 200 mesh EM grids (Quantifoil Micro Tools GmbH ...
-
bioRxiv - Biophysics 2024Quote: ... The sample was applied in aliquots of 3 µL to Quantifoil R 1.2/1.3 holey carbon (copper) grids (Quantifoil microtools), which were rendered hydrophilic before use by glow-discharge treatment (Pelco easiGlow) ...
-
bioRxiv - Biophysics 2024Quote: ... 10 mM DTT was incubated for 3 days at 30 °C and 2.5 μL of the solution was applied onto a Quantifoil R 1.2/1.3 200 mesh Cu grid (Quantifoil) and plunge-frozen in liquid ethane by a Vitrobot Mark IV (FEI) ...
-
bioRxiv - Microbiology 2021Quote: ... 3 μL were applied onto a Cu grid with a holey carbon film (Quantifoil R 2/2; Quantifoil, Jena, Germany), blotted ...
-
bioRxiv - Microbiology 2021Quote: ... 3 μL were applied onto a Cu grid with a holey carbon film (Quantifoil R 2/2; Quantifoil, Jena, Germany), blotted ...
-
bioRxiv - Microbiology 2022Quote: ... 3 mm gold EM finder grids with a perforated carbon film (R 2/2, 200 mesh) were purchased from Quantifoil (AU G200F1 finder ...
-
bioRxiv - Cell Biology 2023Quote: ... An aliquot of 3 ul cell suspension was applied to the glow-discharged holey carbon-coated copper (R 2/1, 200 mesh) (Quantifoil) and blotted for 9 seconds by Leica GP2 (Leica Microsystems) ...
-
bioRxiv - Biochemistry 2024Quote: ... 3 μL of hexapeptide sample were applied to glow-discharged Quantifoil R 2/2 grids (Quantifoil Micro tools GmbH, Germany), blotted for 1 second ...
-
bioRxiv - Biochemistry 2022Quote: ... stock solution was mixed with 3.5 µL of the KWOCA 4 sample and 3 µl were immediately loaded onto the UltrAuFoil R 1.2/1.3 grids (Au, 300-mesh; Quantifoil Micro Tools GmbH). Prior to sample loading the grids were subjected to Ar/O2 plasma cleaning for 10 s on a Solarus 950 plasma cleaner (Gatan) ...
-
bioRxiv - Microbiology 2021Quote: ... and 5 µl of the mixture was placed onto freshly glow discharged holey carbon grids (R 2/1, Quantifoil) for 1 min ...
-
bioRxiv - Biophysics 2023Quote: R 1.2/1.3 (Quantifoil) (Electron Microscopy Sciences ...
-
bioRxiv - Immunology 2022Quote: ... detergent at a final concentration of 0.005 mM was added to each sample and 3 µl of that solution was immediately loaded onto plasma-cleaned QuantiFoil R 2/1 (400-mesh; Quantifoil Micro Tools GmbH) and UltrAuFoil R 1.2/1.3 grids (300-mesh ...
-
bioRxiv - Immunology 2020Quote: ... and 3 µl was immediately loaded onto plasma cleaned Quantifoil R 2/1 holey carbon copper gri (Cu, 400-mesh, Quantifoil Micro Tools GmbH). Blotted grids were plunge-frozen into nitrogen-cooled liquid ethane.
-
bioRxiv - Biophysics 2022Quote: ... an aliquot of 3 μL of sample was applied onto a glow-discharged holey carbon-coated copper grid (300 mesh, QUANTIFOIL® R 2/1) or holey gold grid (300 mesh ...
-
bioRxiv - Biochemistry 2023Quote: Farnesylated GBP1 reconstituted on liposomes (as described above) were supplemented with 5 nm colloidal gold and applied on glow-discharged UltrAuFoil R 2/2 gold grids (Quantifoil Micro Tools), flash-frozen in liquid ethane using a Vitrobot Mark II device (FEI) ...
-
bioRxiv - Biochemistry 2023Quote: ... The most concentrated fraction was spun for 5 min at 13K rpm before applying 3 µL to UltraAuFoil R1.2/1.3 gold support grids (Quantifoil). Prior to sample applications grids were glow-discharged for 3 min in Pelco easiGlow glow-discharger (Pelco ...
-
bioRxiv - Microbiology 2022Quote: ... 5 µL of the mixture was placed onto freshly glow discharged holey carbon grids (Quantifoil™ R 2/1 on 200 copper mesh) for 1 minute ...
-
bioRxiv - Biochemistry 2024Quote: ... carbon-coated (Quantifoil R 2/2) 200-mesh copper grids (Electron Microscopy Sciences ...
-
bioRxiv - Biochemistry 2024Quote: ... Grids (Quantifoil UltrAuFoil R 0.6/1) were glow-discharged (20 mA ...
-
bioRxiv - Biochemistry 2024Quote: 3µl of the AtGDH-AKG bound binary complex (3 mg/ml) was applied to freshly glow-discharged holey carbon grids (Quantifoil Au R 0.6/1.0 300 mesh). For the apo form AnGDH dataset ...
-
bioRxiv - Biochemistry 2022Quote: ... or AE1-Niflumic acid at 5 mg/ml were applied to glow-discharged holey carbon EM grids (Quantifoil 300 copper mesh, R1.2/1.3) in an EM-GP2 plunge freezer (Leica) ...
-
bioRxiv - Molecular Biology 2021Quote: ... 3.5 μL was applied to a glow-discharged Quantifoil copper grid with 2 nm continuous carbon support over holes (Quantifoil R 2/4 400 mesh), blotted ...
-
bioRxiv - Biochemistry 2022Quote: ... holey copper grids (QUANTIFOIL R 2/2). 3.5-μl samples were adsorbed for 1 min at +20 °C ...
-
bioRxiv - Microbiology 2020Quote: Holey carbon-coated (R 2/2; Quantifoil) Au-G200F1 grids were analyzed in cryo-conditions by MISTRAL microscope at ALBA synchrotron ...
-
bioRxiv - Immunology 2022Quote: ... grids (Quantifoil R 1.2/1.3 300 mesh) were first glow discharged for 60 seconds at 15 mA with a Pelco easiGlow glow discharge unit and 4 μL LNP suspension was applied to the surface of the grid ...
-
bioRxiv - Biophysics 2023Quote: Gold 200 mesh carbon or SiO2 R 2/1 grids or R 1.2/20 grids (Quantifoil Micro Tools GmbH) were coated with ∼8 nm of carbon using a Leica ACE600 (Leica Microsystems GmbH) ...
-
bioRxiv - Biochemistry 2022Quote: Grids (Quantifoil R3/3 Cu300 with 3 nm holey carbon) were glow discharged and 4 µL of sample (8 OD260/mL ...
-
bioRxiv - Neuroscience 2020Quote: ... 3.5 uL of sample was applied at a concentration of 3-5 mg/mL to glow-discharged holey carbon grids (Quantifoil R1.2/1.3). The grids were blotted using an FEI Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Neuroscience 2021Quote: ... 300 mesh R 1.2/1.3 gold grids (Quantifoil). Samples were plunge frozen in liquid nitrogen cooled liquid ethane using a FEI Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Molecular Biology 2023Quote: ... UltrAuFoil R 1.2/1.3 300 Au mesh (Quantifoil) grids were glow discharged with residual air for 30 seconds ...
-
bioRxiv - Molecular Biology 2022Quote: ... UltrAuFoil R 1.2/1.3 300 Au mesh (Quantifoil) grids were glow discharged with residual air for 30 seconds ...
-
bioRxiv - Cell Biology 2020Quote: ... 3 μl of samples were applied to glow-discharged Quantifoil R 0.6/1 and R 1.2/1.3 grids (Quantifoil Micro tools GmbH, Germany), blotted for 3 s and then flash frozen in liquid ethane using the automatic plunge freezer EM GP2 at 100% relative humidity ...
-
bioRxiv - Molecular Biology 2022Quote: The purified complex samples (3 μL at 5-8 mg/mL) were applied to glow-discharged holey grids (Quantifoil R1.2/1.3, 300 mesh) and subsequently vitrified using a Vitrobot Mark IV (ThermoFisher ...
-
bioRxiv - Biophysics 2020Quote: ... or QUANTIFOIL R 2/2 holey carbon grids (Quantifoil Micro Tools GmbH ...
-
bioRxiv - Microbiology 2024Quote: ... copper EM grids (Cu 200 R 2/1, Quantifoil) were used ...
-
bioRxiv - Biochemistry 2023Quote: The grids (Quantifoil R 1.2/1.3 Cu 300 mesh) were glow discharged at 10 mA for 60s (EM ACE200 ...
-
bioRxiv - Biochemistry 2024Quote: ... 300 mesh 100 R 1.2/1.3 UltraAuFoil grids (Quantifoil) with 2 nm carbon were glow discharged in a PELCO easiGlow for 12 seconds at 25 mAmp and 0.37 mBar before 4 μL of sample were added to each grid ...
-
bioRxiv - Molecular Biology 2023Quote: Freshly purified ZorAB sample was concentrated to 2-3 mg/mL and 2.7 μL protein was applied onto the glow-discharged (30 s, 5 mA) grids (Quantifoil R0.6/1 300 mesh Au) and plunge-frozen into liquid ethane using a Vitrobot Mark IV (FEI ...
-
bioRxiv - Biophysics 2022Quote: ... for 25 s) grid (For GDN 150mM: UltrAuFoil 300 mesh R 1.2/1.3, other samples: gold holey carbon Quantifoil 300 mesh R 1.2/1.3). After a ∼5 s manual wait time ...
-
bioRxiv - Biophysics 2021Quote: Holey carbon grids (Quantifoil Au 300 mesh, R 0.6/1) coated with home-made ultrathin continuous carbon were glow-discharged by plasma cleaner (Harrick ...
-
bioRxiv - Biophysics 2020Quote: Holey carbon grids (Quantifoil Au 300 mesh, R 0.6/1) were glow-discharged by Solarus advanced plasma system (Gatan ...
-
bioRxiv - Biophysics 2022Quote: ... 300 mesh R 1.2/1.3 gold grids (Quantifoil, Großlöbichau, Germany) and plunge frozen in liquid ethane using a FEI Vitrobot Mark IV (ThermoFisher Scientific ...
-
bioRxiv - Biophysics 2021Quote: UltrAuFoil holey gold grids (Quantifoil R 0.6/1.0, Au 300) were plasma cleaned for thirty seconds with H2 and O2 (Gatan) ...
-
bioRxiv - Physiology 2021Quote: ... 300 mesh R 1.2/1.3 gold grids (Quantifoil, Großlöbichau, Germany). A Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Biochemistry 2020Quote: ... 300 mesh R 1.2/1.3 gold grids (Quantifoil, Großlöbichau, Germany). A FEI Vitrobot Mark IV (ThermoFisher Scientific ...