Labshake search
Citations for Quantifoil Micro Tools :
151 - 200 of 677 citations for trans 2 2 4 Methoxyphenyl 2 oxoethyl cyclohexane 1 carboxylic acid since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Immunology 2023Quote: ... Then 3 μl of the mixture was applied to a Quantifoil-Au-2/1-3C grid (Quantifoil) pretreated by glow-discharging at 20 mA for 1 min ...
-
Genome modularization reveals overlapped gene topology is necessary for efficient viral reproductionbioRxiv - Synthetic Biology 2020Quote: A 4 μL solution of co-isolated small particles were applied to glow-discharged copper grids (Quantifoil R2/2, Quantifoil Micro Tools), blotting for 3-seconds at 4 °C with 90% humidity and plunging into liquid ethane using a Lecia EM GP device (Leica Microsystems ...
-
Genome modularization reveals overlapped gene topology is necessary for efficient viral reproductionbioRxiv - Synthetic Biology 2020Quote: A 4 μL solution of co-isolated small particles were applied to glow-discharged copper grids (Quantifoil R2/2, Quantifoil Micro Tools), blotting for 3-seconds at 4 °C with 90% humidity and plunging into liquid ethane using a Lecia EM GP device (Leica Microsystems ...
-
Mycobacteria form viable cell wall-deficient cells that are undetectable by conventional diagnosticsbioRxiv - Microbiology 2022Quote: ... of which 3-4 µL was applied on glow-discharged 200 mesh copper grids with an extra thick R2/2 carbon film (Quantifoil Micro Tools). Vitrification was performed using an automated Leica EM GP plunge-freezer ...
-
bioRxiv - Biophysics 2020Quote: Quantifoil grids (200 mesh Au R2/2 and Au Finder; Quantifoil Micro Tools GmbH ...
-
bioRxiv - Biochemistry 2022Quote: ... R3/3 copper grids with a 2 nm carbon coating (Quantifoil) using a Vitrobot mark IV (FEI ...
-
bioRxiv - Microbiology 2022Quote: ... EM grids (R2/2, Cu 200 mesh; Quantifoil Micro Tools GmbH) were glow-discharged for 45 sec at 25 mA by PELCO easiGlow discharger ...
-
bioRxiv - Molecular Biology 2021Quote: ... UltrAuFoil (Russo and Passmore, 2014) R2/2 200 mesh grids (Quantifoil) were glow discharged for 15 s at 30 mA in a Quorum SC7620 ...
-
bioRxiv - Biochemistry 2023Quote: ... Holey carbon R2/2 300 mesh grids (Quantifoil Micro Tools GmbH) were glow-discharged for 90 sec at 25 mA using a PELCO easiGlow glow discharge cleaning system ...
-
bioRxiv - Microbiology 2022Quote: ... Gold quantifoil R2/2 200 mesh grids (Quantifoil Micro Tools GmbH) were sterilised with 70% ethanol and placed in glass bottomed MatTek dishes (MatTek Corporation ...
-
bioRxiv - Microbiology 2024Quote: Cryo-EM gold grids (Quantifoil R2/2 Au 200 mesh, Quantifoil) were placed in the slots of a custom-made PDMS stencil (Alvéole ...
-
bioRxiv - Microbiology 2024Quote: Cryo-EM gold grids (Quantifoil R2/2 Au 200 mesh, Quantifoil) were placed in the slots of a custom-made PDMS stencil (Alvéole ...
-
bioRxiv - Biochemistry 2024Quote: Quantifiol R 1.2/1.3 Au 400 mesh 2 nm Carbon (Quantifoil) were glow discharged at 0.2 atm for 30 s and were loaded onto a FEI vitrobot (Thermo Fisher) ...
-
bioRxiv - Biochemistry 2024Quote: 4 μl of the inhibition reaction mixture was applied onto plasma cleaned holey carbon grids coated with 2nm thick amorphous carbon (Quantifoil R 2/2, UT, 300 Mesh, Copper). Following 30 sec of incubation inside the chamber of FEI Vitrobot MK IV (FEI ...
-
bioRxiv - Plant Biology 2022Quote: ... 2 μL of sample solution was applied onto a holey carbon grid (Quantifoil R2/1, Cu 300 mesh) covered with a thin amorphous carbon film ...
-
bioRxiv - Immunology 2021Quote: ... Then 3 μl of the protein mixture was applied to a Quantifoil-Cu-2/1-3C grid (Quantifoil) pretreated by glow-discharging at 15 mA for 1 min ...
-
bioRxiv - Biochemistry 2022Quote: ... were prepared by applying 3 μL of freshly prepared STC (1:2 dilution) to UltrAuFoil 300 mesh R1.2/1.3 holey grids (Quantifoil), glow-discharged for 60 s at 10 mA (Leica EM ACE200) ...
-
bioRxiv - Plant Biology 2023Quote: ... H4 NCPs were applied to Quantifoil R2/1 200-mesh grids coated with 2 nm of carbon (Quantifoil). H4.VS were applied to unsupported Quantifoil R2/1 200-mesh grids (Quantifoil) ...
-
bioRxiv - Biophysics 2024Quote: 3.5 µL of sample were applied to 2/1 Quantifoil holey carbon grids (Quantifoil Micro Tools GmbH, Germany) or 1.2/1.3 Ultrafoil holey gold grids (Quantifoil Micro Tools GmbH ...
-
bioRxiv - Microbiology 2023Quote: ... sample were placed onto glow-discharged Quantifoil R2/1 Cu300 holey carbon grids (1 µm spacing, 2 µm holes, copper mesh) (Quantifoil, Germany), blotted for 3.5 s before flash-freezing in liquid ethane using a Vitrobot mark IV (FEI ...
-
bioRxiv - Biochemistry 2024Quote: ... Those nucleosomes that passed the quality control were then loaded into a freshly glow discharged holey carbon golden grid (Quantifoil™ R 2/2 on 300 gold mesh) (2.5 µg of nucleosome diluted in 40 mM NaCl reconstitution buffer in 3 μl was loaded in the grid) ...
-
bioRxiv - Cell Biology 2020Quote: Either 200 mesh gold holey carbon grids (R2/2; Quantifoil Micro Tools) or 200 mesh gold grids (Science Services ...
-
bioRxiv - Microbiology 2022Quote: ... cells were seeded on R2/2 gold UltrAufoil grids (200 mesh, Quantifoil Micro Tools GmbH ...
-
bioRxiv - Molecular Biology 2020Quote: ... gold 300 mesh Quantifoil R2/2 holey carbon grids (Quantifoil Micro Tools) were glow discharged using an Edwards Sputter Coater 305B ...
-
bioRxiv - Biophysics 2022Quote: ... Quantifoil grids (200 mesh Au R2/2 carbon or SiO2 film; Quantifoil Micro Tools GmbH ...
-
bioRxiv - Neuroscience 2020Quote: ... electron microscopy (EM) gold finder grids (Quantifoil R2/2 Au NH2 grids) were plasma cleaned with H2 and O2 for 10 s using a plasma cleaning system (Gatan) ...
-
bioRxiv - Biochemistry 2022Quote: Quantifoil R2/2 Cu300 or Quantifoil R1.2/1.3 Cu300 (Quantifoil Micro Tools) grids were glow-discharged using the GloQube plasma cleaner (Quorum ...
-
bioRxiv - Biochemistry 2021Quote: ... grids with an additional thin layer (∼2 nm) of continues carbon (Quantifoil). The GudB6-GltA2B2 complex solution was applied to the grid in a single 2.5 µl drop ...
-
bioRxiv - Microbiology 2022Quote: ... Quantifoil R2/2 200 mesh carbon grids (Quantifoil Micro Tools, Jena, Germany) were plasma cleaned using the Quorum Q150s glow discharger (Quorum technologies ...
-
bioRxiv - Molecular Biology 2022Quote: Quantifoil 200 mesh holey carbon R2/2 gold grids (Quantifoil Micro Tools) were glow discharged (PELCO easiGlow ...
-
bioRxiv - Microbiology 2022Quote: R2/2 carbon-coated 200 mesh copper Quantifoil grids (Quantifoil Micro Tools) were first glow-discharged for 60 seconds ...
-
bioRxiv - Biophysics 2024Quote: ... R1.2/1.3 or R2/2 UltrAuFoil® grids (Quantifoil Micro Tools GmbH) were glow-discharged with 40 mA for 5 min inside a Quorum GloQube® Plus unit ...
-
bioRxiv - Molecular Biology 2024Quote: ... Quantifoil R2/2 gold 200 mesh grid (Quantifoil Micro Tools GmbH, Germany) glow-discharged for 30 sec in a PIB-10 Ion Bombarder (Vacuum Device Inc ...
-
bioRxiv - Biochemistry 2024Quote: Standard holey carbon electron microscopy grids (Quantifoil, Cu 200 mesh, R2/2) were glow discharged for 30 s at 15 mA on the negative setting ...
-
bioRxiv - Molecular Biology 2021Quote: ... 4 μl of protein sample (about 0.73 mg/ml) was applied onto a glow-discharged holey carbon grid (Quantifoil Au, R2/2, 300 mesh). After blotting for 3 s ...
-
bioRxiv - Biophysics 2020Quote: Three microliters of purified HCoV-NL63 virions (4.5 mg/mL) were first applied to 300-mesh R2/1 + 2 nm C-film grids (Quantifoil) that had been glow-discharged for 15s PELCO easiGlow (TED PELLA ...
-
bioRxiv - Microbiology 2021Quote: ... and 5 µl of the mixture was placed onto freshly glow discharged holey carbon grids (R 2/1, Quantifoil) for 1 min ...
-
bioRxiv - Biophysics 2024Quote: ... Aliquots of 1.25 – 1.5 ul RyR1-nanodisc were applied onto each side of glow-discharged C-Flat - 2/1 - 3Au holey-carbon (Protochips, NC) or UltraAufoil -1.2/1.3 holey-gold (Quantifoil, Germany) with 300 TEM mesh ...
-
bioRxiv - Biophysics 2023Quote: Gold 200 mesh carbon or SiO2 R 2/1 grids or R 1.2/20 grids (Quantifoil Micro Tools GmbH) were coated with ∼8 nm of carbon using a Leica ACE600 (Leica Microsystems GmbH) ...
-
bioRxiv - Microbiology 2021Quote: ... loaded onto a R2/2 200 mesh Cu grid (Quantifoil Micro Tools, GmbH), and plunge frozen in liquid ethane using the automated Leica EM GP plunge freezer (Leica Microsystems GmbH) ...
-
bioRxiv - Cell Biology 2020Quote: 200 mesh holey silicon dioxide (SiO2) titanium grids (R2/2; Quantifoil Micro Tools) were glow discharged in an ELMO glow discharge unit (Cordouan Technologies ...
-
bioRxiv - Microbiology 2024Quote: Glow-discharged gold EM grids (200 mesh, Au, holey SiO, R1/2, Quantifoil) were placed into polydimethylsiloxane Sylgard 184 (Farnell GmbH ...
-
bioRxiv - Microbiology 2024Quote: Ultrafoil Au R2/2 200 mesh grids (200 mesh, Quantifoil Micro Tools GmbH) were glow discharged ...
-
bioRxiv - Microbiology 2020Quote: ... A small volume (4 µL) of cells was then transferred onto freshly glow‐discharged copper R2/2 200 Quantifoil holey carbon grids (Quantifoil Micro Tools GmbH, Jena, Germany). Grids were then blotted and plunge‐frozen in a liquid ethane/propane mixture 31 using an FEI Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Biochemistry 2020Quote: ... 3 μL of the concentrated RdRp-RNA complex were mixed with 0.5 μl of octyl ß-D-glucopyranoside (0.003% final concentration) and applied to freshly glow discharged R 2/1 holey carbon grids (Quantifoil). The grids were blotted for 5 seconds using a Vitrobot MarkIV (Thermo Fischer Scientific ...
-
bioRxiv - Biochemistry 2021Quote: ... 3 µL of the concentrated RdRp-RNA complex were mixed with 0.5 µl of octyl ß-D-glucopyranoside (0.003% final concentration) and applied to freshly glow discharged R 2/1 holey carbon grids (Quantifoil). The grids were blotted for 7 seconds with blot force 5 using a Vitrobot MarkIV (Thermo Fischer Scientific ...
-
bioRxiv - Biophysics 2020Quote: ... 3 μL of the concentrated RdRp-RNA complex were mixed with 0.5 μl of octyl ß-D-glucopyranoside (0.003% final concentration) and applied to freshly glow discharged R 2/1 holey carbon grids (Quantifoil). Prior to flash freezing in liquid ethane ...
-
bioRxiv - Molecular Biology 2020Quote: ... a 2.2-µL aliquot of this sample was applied to a plasma cleaned holey carbon grid (R2/1, 200 mesh; Quantifoil) or Graphene Oxide-Lacey Carbon grid (300 mesh ...
-
bioRxiv - Biophysics 2020Quote: ... Mycoplasma pneumoniae strain M129(ATCC 29342)cells were grown on 200 mesh gold grids coated with a holey carbon support (R 2/1, Quantifoil). Cells were cultivated at 37 °C in modified Hayflick medium ...
-
bioRxiv - Microbiology 2022Quote: ... and 4 µl of the mixture was applied to a glow-discharged holey-carbon copper EM grid (R2/1 or R2/2, Quantifoil). The grid was automatically blotted from the backside for 4-6 s in a Mark IV Vitrobot by using a Teflon sheet on the front pad ...