Labshake search
Citations for Quantifoil Micro Tools :
151 - 200 of 719 citations for 1 2 Chloropyridin 3 yl 3 3 dimethylazetidin 2 one since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2024Quote: ... 3 µL of sample were applied on a glow-discharged holey carbon grids (Quantifoil Cu R1.2/1.3 300 mesh), blotted for 5 s at 100% humidity and 4°C and plunge-frozen in liquid ethane using a Vitrobot Mark IV ...
-
bioRxiv - Bioengineering 2024Quote: About 3 μl droplets emulsion were applied onto glow-discharged holey carbon grids (Quantifoil Cu R1.2/1.3, 300 mesh), blotted with a Vitrobot Marker IV (Thermo Fisher Scientific ...
-
bioRxiv - Biochemistry 2024Quote: ... 3 μL of the mixture was applied to a glow-discharged carbon-coated grid (Quantifoil R1.2/1.3 Au300 mesh) and incubated for 60 s in the chamber of a Vitrobot (22°C ...
-
bioRxiv - Biophysics 2024Quote: ... The sample was applied in aliquots of 3 µL to Quantifoil R 1.2/1.3 holey carbon (copper) grids (Quantifoil microtools), which were rendered hydrophilic before use by glow-discharge treatment (Pelco easiGlow) ...
-
bioRxiv - Cell Biology 2024Quote: 3 µl cell suspension was applied on glow-discharged (Pelco easiGlow) R1/4 SiO2 gold 200 mesh grids (Quantifoil), blotted for 10 sec from the backside and plunge-frozen on a Leica EM GP2 plunger at 23 °C ...
-
bioRxiv - Biophysics 2020Quote: ... or QUANTIFOIL R 2/2 holey carbon grids (Quantifoil Micro Tools GmbH ...
-
bioRxiv - Microbiology 2024Quote: ... copper EM grids (Cu 200 R 2/1, Quantifoil) were used ...
-
bioRxiv - Biophysics 2022Quote: ... holey carbon grid coated with 2 nm ultrathin carbon film (Quantifoil 300-mesh, R 2/2). After waiting for 60 s ...
-
bioRxiv - Immunology 2023Quote: ... respectively) and 3 μl were kept 5 min at RT until their application onto glow-discharged holey carbon grids (Quantifoil, Au 300 mesh, R 0.6/1). The grids were blotted and then plunged into liquid ethane using a FEI Vitrobot Mark IV at 20°C and 95% relative humidity ...
-
bioRxiv - Pharmacology and Toxicology 2021Quote: Samples (3 μL) were applied to a glow-discharged UltrAufoil R1.2/1.3 300 mesh holey grid (Quantifoil GmbH, Großlöbichau, Germany) and were flash frozen in liquid ethane using the Vitrobot mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Immunology 2022Quote: ... 3 μL of the mixture was applied to a glow-discharge holey carbon grids (Quantifoil, Cu 200 mesh, R1.2/1.3). The grid was blotted for 4.5 s in 100% humidity before being flash frozen in liquid ethane by using a Vitrobot Mark IV (Thermo Fisher) ...
-
bioRxiv - Immunology 2023Quote: ... 3 μL of the purified complex were loaded onto a glow-discharged holey grid (Quantifoil Au 300 mesh R1.2/1.3), and subsequently were plunge-frozen in liquid ethane using Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... 3 μl of the samples were applied to glow-discharged holey carbon EM grids (Quantifoil 300 copper mesh, R1.2/1.3) in an EM-GP2 plunge freezer (Leica) ...
-
bioRxiv - Immunology 2023Quote: ... 3 μL of each LNP sample was deposited onto a holey carbon grid that was glow-discharged (Quantifoil R1.2/1.3) and vitrificated using a Vitrobot Mark IV System (FEI/Thermo Scientific ...
-
bioRxiv - Neuroscience 2024Quote: Protein sample aliquots of 3 µL were applied to glow-discharged holey carbon grids (Quantifoil Au R1.2/R1.3 300 mesh), blotted with filter paper ...
-
bioRxiv - Biophysics 2024Quote: ... Cryo-EM grids were obtained by flash-freezing 3 µL of purified IPNV particles on glow-discharged holey carbon grids (Quantifoil R2/2 ...
-
bioRxiv - Biochemistry 2021Quote: Holey grids (gold, 200 mesh, r 2/2 by Quantifoil) were glow-discharged for 30 seconds using a Pelco glow discharge system ...
-
bioRxiv - Biophysics 2024Quote: Holey carbon grids (Quantifoil Au R 2/2, 200 mesh) were glow-discharged with easiGlow at 20 mA for 45 s ...
-
bioRxiv - Biophysics 2021Quote: 4 µL of purified HsPepT1 at 2 mg/mL was applied to a glow discharged gold holey carbon 2/1 300-mesh grid (Quantifoil). The grid was blotted for 4 s at 0 force before being plunge vitrified in liquid propane using a Mark IV Vitrobot (ThermoFisher) ...
-
bioRxiv - Biophysics 2023Quote: ... split onto Poly-D-Lysine coated R 2/2 grids (QUANTIFOIL 100 Holey Carbon Films ...
-
bioRxiv - Immunology 2024Quote: ... The sample was prepared on Quantifoil Cu 300 2/2 (Quantifoil) grids and was frozen in liquid ethane using the Vitroblot Mark IV (Thermo Fisher ...
-
A distinctive ligand recognition mechanism by the human vasoactive intestinal polypeptide receptor 2bioRxiv - Molecular Biology 2021Quote: The purified PACAP27–VIP2R–Gs complex (3 μL at 3.7 mg per mL) was applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3). Vitrification was performed using a Vitrobot Mark IV (ThermoFisher Scientific ...
-
bioRxiv - Pharmacology and Toxicology 2020Quote: Samples (3 µL) were applied to a glow-discharged UltrAuFoil R1.2/1.3 Au 300 gold foil grids (Quantifoil GmbH, Großlöbichau, Germany) and were flash frozen in liquid ethane using a Vitrobot mark IV (Thermo Fisher Scientific ...
-
Structure of the Human Signal Peptidase Complex Reveals the Determinants for Signal Peptide CleavagebioRxiv - Biochemistry 2020Quote: ... 3 µL samples were applied to freshly glow-discharged Cu 200 Holey Carbon R1.2/1.3 grids (Quantifoil, for samples without FFosC), or Cu 200 Holey Carbon R2/1 grids (Quantifoil ...
-
bioRxiv - Biochemistry 2021Quote: The purified TIP39–PTH2R–Gs complex (3 μL at 8.5 mg per mL) was applied on a glow-discharged holey carbon grid (Quantifoil R1.2/1.3). Vitrification was performed using a Vitrobot Mark IV (ThermoFisher Scientific ...
-
bioRxiv - Biochemistry 2022Quote: ... stock solution was mixed with 3.5 µL of the KWOCA 4 sample and 3 µl were immediately loaded onto the UltrAuFoil R 1.2/1.3 grids (Au, 300-mesh; Quantifoil Micro Tools GmbH). Prior to sample loading the grids were subjected to Ar/O2 plasma cleaning for 10 s on a Solarus 950 plasma cleaner (Gatan) ...
-
bioRxiv - Biochemistry 2024Quote: ... Cryo-EM grids were prepared by applying 3 µl of concentrated sample onto 400-mesh R1.2/1.3 UltrAuFoil grids (Quantifoil Micro Tools GmbH), which had rendered hydrophilic by glow discharging at 15mA for 60seconds with a PELCO EasyGlow device (TED PELLA ...
-
bioRxiv - Neuroscience 2023Quote: ... each time was sequentially blotted 3 times to 300-mesh holey carbon Au R1.2/1.3 grids treated with 25s of glow discharge (Quantifoil, Micro Tools GmbH). Fluorinated Fos-choline-8 (0.65 mM ...
-
bioRxiv - Molecular Biology 2022Quote: ... The complex (3 μL) was quickly applied on a glow-discharged UltraAuFoil R1.2/1.3 300 mesh holey Au grids (Quantifoil Micro Tools GmbH), blotted with Vitrobot Mark IV (FEI) ...
-
bioRxiv - Molecular Biology 2022Quote: ... 4 μL of the cells were applied to a glow-discharged 200 mesh holey carbon grid copper grid (Quantifoil R1.2/3) and vitrified in a liquid ethane on a Vitrobot Mark IV (Thermo Scientific ...
-
bioRxiv - Microbiology 2024Quote: ... The sample solution (3 μl) was applied to glow-discharged (20 mAmp, 30 sec, Quorum GloQube) Quantifoil R1.2/1.3 grids (Quantifoil Micro Tools GmbH), blotted for 5 s using blot force 0 and plunge frozen into liquid ethane using Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Biophysics 2024Quote: Cryo-EM grids for the SIRT7-nucleosome complexes were prepared by applying 3 μL of concentrated sample onto 400-gold mesh R1.2/1.3 Quantifoil grids (Quantifoil Micro Tools GmbH). These grids were rendered hydrophilic by glow discharging at 15 mA for 90 s with a PELCO easiGlow device (Ted Pella Inc.) ...
-
bioRxiv - Biophysics 2023Quote: ... glow discharged QUANTIFOIL® copper R 2/2 grid with a 2 nm thin extra carbon layer (QUANTIFOIL, GMBH) was used ...
-
bioRxiv - Biophysics 2024Quote: ... samples that have been analyzed here are Influenza A/Hong Kong/1/1968 virions that are produced from MDCK cells grown directly on cryoEM grids (QF AU200 R 2/2, Quantifoil, Germany), infected at a multiplicity of infection <1 ...
-
bioRxiv - Biochemistry 2021Quote: ... Quantifoil Cu 300 mesh (R 2/2 geometry; Quantifoil Micro Tools GMBH) covered with a thin layer of 3 nm carbon were used for the for the GTPBP5KO sample ...
-
bioRxiv - Immunology 2022Quote: ... were incubated for 3 min at room temperature and then loaded onto the glow-discharged holy-carbon gold grids (Quantifoil, R1.2/1.3). The grids were washed using the buffer containing 20 mM HEPES ...
-
bioRxiv - Biophysics 2021Quote: ... 3 μl of samples were applied onto a glow-discharged gold grids covered with holey carbon film (Quantifoil, 300 mesh 1.2/1.3) and blotted using a Vitrobot Mark IV (FEI Company ...
-
bioRxiv - Biochemistry 2022Quote: A 3 µL of the protein solutions was applied onto the glow-discharged holey carbon grids (Quantifoil Cu R1.2/1.3, 300 mesh). The grids were plunge-frozen in liquid ethane using a Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Neuroscience 2020Quote: ... 3.5 uL of sample was applied at a concentration of 3-5 mg/mL to glow-discharged holey carbon grids (Quantifoil R1.2/1.3). The grids were blotted using an FEI Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Molecular Biology 2021Quote: The purified tirzepatide–GLP-1R–Gs–Nb35 complex (3 μL at about 20 mg/mL) was applied to a glow-discharged holey carbon grid (Quantifoil R1.2/1.3) and blotted subsequently ...
-
bioRxiv - Molecular Biology 2023Quote: 3 µl of freshly purified NbE-µOR-Fab module complex were applied onto holey gold grids (Quantifoil UltrAuFoil R1.2/1.3, 300 mesh), front blotted for 3-4 seconds with 1 mm additional movement (95% humidity at 15°C ...
-
bioRxiv - Cell Biology 2021Quote: R 2/1 Holey Carbon Au 200 mesh EM grids (Quantifoil) were coated with approximately 20 nm of carbon in a MED 020 carbon coater (BAL-TEC ...
-
bioRxiv - Molecular Biology 2022Quote: ... The plus carbon sample (Quantifoil Cu300 R2/1 + 2 nm C) was blotted for 2 s with blot force +3 after a 30 s wait time after sample application and immediately plunge frozen in liquid ethane ...
-
bioRxiv - Biochemistry 2022Quote: R2/2 grids (Quantifoil) were covered with a thin layer of continuous carbon (estimated to be 50 Å thick ...
-
bioRxiv - Microbiology 2024Quote: ... Continuous carbon grids (Quantifoil R 2/2 on Cu 300 mesh grids + 2 nm Carbon, Quantifoil Micro Tools C2-C16nCu30-01) were glow-discharged for 5 sec in an easiGlow Glow Discharge Cleaning System (Ted Pella Inc.) ...
-
bioRxiv - Biochemistry 2022Quote: ... Continuous carbon grids (Quantifoil R 2/2 on Cu 300 mesh grids + 2 nm Carbon, Quantifoil Micro Tools C2-C16nCu30-01) were glow-discharged for 5 sec in an easiGlow Glow Discharge Cleaning System (Ted Pella Inc.) ...
-
bioRxiv - Molecular Biology 2022Quote: ... Glow-discharged carbon coated gold mesh grids (QF 2/2 AU 200, Quantifoil) were placed on the edge of the glass microscopy slides ...
-
bioRxiv - Biochemistry 2023Quote: ... Cryo-EM grids (carbon-coated Quantifoil R 2/2 cupper grids, 300 mesh) were plunge-frozen using a Vitrobot IV (Thermo Fisher Scientific ...
-
bioRxiv - Bioengineering 2022Quote: ... holey carbon grids (Ultrafoil 25 nM Au R 2/2 200 mesh; Quantifoil) were glow-discharged for 10 s using the Solarus plasma cleaner (Gatan) ...
-
bioRxiv - Biochemistry 2023Quote: ... the same proteins were applied to holey grids with a 2 nm carbon film (Quantifoil Cu 2/2 200 mesh from EMS). Samples were frozen after a total of 145 min on the grids without carbon film and 150 min on the grids with carbon film ...