Labshake search
Citations for Quantifoil Micro Tools :
651 - 677 of 677 citations for 4 2 Hydroxyimino 2 4 methoxy phenyl ethyl piperazine 1 carboxylic acid tert butyl ester since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2020Quote: ... 3 μL of diluted sample was applied to a glow-discharged (R2/1 300 mesh holey carbon copper grid (Quantifoil Micro Tools GmbH) and plunge-frozen in liquid ethane using a Vitrobot Mark IV (FEI ...
-
bioRxiv - Biochemistry 2022Quote: Three microliters of Ct80S-RAC pull-out sample at 200 nM concentration was applied on holey carbon grids (Quantifoil R2/1 grid, Quantifoil Micro Tools, GmbH) and plunged-frozen into liquid ethane using a Vitrobot (FEI) ...
-
bioRxiv - Microbiology 2020Quote: Usually 5 μL of liquid culture (OD680 ~ 0.3) was pipetted onto holey carbon-coated copper grids (R2/1, 200 mesh, Quantifoil Micro Tools, Jena, Germany). The grids were blotted from the reverse side and immediately plunged into the liquid ethane at liquid nitrogen temperature atmosphere using a Vitrobot ...
-
bioRxiv - Microbiology 2020Quote: ... 3.5 microliters of the purified virus sample was pipetted onto a glow-discharged R2/1 Quantifoil grid (Quantifoil Micro Tools GmbH, Jena, Germany), blotted for 2.5 seconds ...
-
bioRxiv - Molecular Biology 2022Quote: ... 3 μL of sample (10 μM EGFP in PBS) was deposited onto glow-discharged grids (Electron Microscopy Science and Quantifoil – see Table 1), prior to blotting the grids from the sample-side for 3 seconds.
-
bioRxiv - Microbiology 2023Quote: 3 µL of the purified FL or truncated RSV NC sample were applied to a glow-discharged R2/1 300 mesh holey carbon copper grid (Quantifoil Micro Tools GmbH) and plunge-frozen in liquid ethane using a Vitrobot Mark IV (FEI ...
-
bioRxiv - Biochemistry 2024Quote: ... 3.5 μL of this protein-DNA mix were applied to 300-mesh copper R2/1 Quantifoil Holey Carbon Grids (Quantifoil Micro Tools GmbH) that had been freshly glow discharged for 30 seconds at 25 mA in a GloQube Glow Discharge System (Quorum Technologies ...
-
bioRxiv - Microbiology 2022Quote: ... 5 µl of bacteria diluted to OD = 0.15 in PBS were deposited on a glow-discharged Quantifoil R2/1 holey carbon grids (Quantifoil Micro Tools GmbH, Germany) and 3 µl gold particles (10 nm BSA tracer ...
-
bioRxiv - Biochemistry 2022Quote: ... three microliters of concentrated phage particles were added to a freshly glow-discharged Quantifoil R2/1 grid (Quantifoil Micro Tools GmbH, Großlöbicha, Germany) and plunge-frozen with a Vitrobot Mk IV into a 50:50 mixture of liquid ethane:propane52
-
bioRxiv - Microbiology 2022Quote: Three-microliter aliquots of all AdSDV capsid populations (~1 mg/mL) were applied to glow-discharged Quantifoil holey carbon grids with a thin layer of carbon (Quantifoil Micro Tools GmbH) and vitrified using a Vitrobot Mark IV (FEI ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... were applied to glow-discharged (25 mA, 10 s) QuantiFoil Gold R 0.6/1 300-mesh holey carbon grids (QuantiFoil, Micro Tools GmbH, Germany), blotted for 4.5 s ...
-
bioRxiv - Biophysics 2021Quote: ... A suspension containing a mixture of 10 nm protein A coated colloidal gold (Aurion) and Ebola VLPs was applied with a volume of 3 µl on a glow discharged EM grid (Quantifoil, 200 Mesh, R2/1). The grid was blotted using No.1 Whatman paper for 3 sec from the back-side in a chamber with controlled humidity set to 70% and the temperature set to 24°C.
-
bioRxiv - Microbiology 2021Quote: ... 5 µl of the cell suspension was placed on freshly glow-discharged (for ∼25 s) holey carbon grids (Quantifoil Cu R2/1, 200 mesh). The grids were front blotted with Whatman filter paper and rapidly frozen in liquid ethane ...
-
bioRxiv - Biophysics 2020Quote: Samples were prepared for CryoEM by applying 5 μl freshly purified Cx46/50-lipid nanodisc complex (∼2.5 mg mL-1) to a glow-discharged holey carbon grid (Quantifoil R 1.2/1.3, 400 mesh) for 10 seconds ...
-
bioRxiv - Bioengineering 2023Quote: ... 3.0 µl aliquots at a concentration of 0.87 or 1.0 mg/ml of the spikeD614G-binder sample or the spikeOmicron-binder sample were applied onto glow-discharged carbon-coated copper grids (Quantifoil R2/1, 400 mesh), blotted for 4.0-8.0 s ...
-
bioRxiv - Molecular Biology 2023Quote: Freshly purified ZorAB sample was concentrated to 2-3 mg/mL and 2.7 μL protein was applied onto the glow-discharged (30 s, 5 mA) grids (Quantifoil R0.6/1 300 mesh Au) and plunge-frozen into liquid ethane using a Vitrobot Mark IV (FEI ...
-
Cryo-EM structure of a eukaryotic zinc transporter at a low pH suggests its Zn2+-releasing mechanismbioRxiv - Biochemistry 2022Quote: ... and 3 μl of the protein solution was applied to glow-discharged (45 s) Quantifoil R2/1 300-mesh gold grids (Quantifoil Micro Tools GmbH, Germany). The grids were blotted with standard Vitrobot filter paper for 2.5 s at 4 °C under 100% humidity and plunged into liquid ethane using a Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Biochemistry 2023Quote: ... 3 μl of protein at a concentration of approximately 10 mg ml−1 were loaded onto glow-discharged holey carbon grids (Quantifoil Au 300 mesh R1.2/1.3 or Quantifoil Cu/Rh 300 mesh R1.2/1.3), after which ...
-
bioRxiv - Cell Biology 2022Quote: ... 3 μL of ∼100 nM (A260 4.0 or 6.0) mitoribosome sample was applied onto a glow-discharged (20 mA for 30 sec) holey-carbon grid (Quantifoil R2/1 copper, mesh 300) coated with continuous carbon (of ∼3 nm thickness ...
-
bioRxiv - Bioengineering 2024Quote: ... LCNP or EV suspensions in PBS (∼1 × 1012 particles/mL) were deposited on 300-mesh lacey carbon-coated copper grids (Quantifoil Micro Tools GmbH, Germany). The grids were previously glow-discharged for 45 s using an Emitech K100X glow discharge system (Quorum Technologies Ltd. ...
-
bioRxiv - Biophysics 2020Quote: Three microliters of the apoferritin samples with 1.5 mg/ml or 0.2 mg/ml were applied onto glow-discharged 200-mesh R2/1 Quantifoil grids (used for the K3 dataset) or 200-mesh R2/1 Quantifoil grids coated with continuous carbon film (Quantifoil, used for the Falcon4 dataset), respectively ...
-
bioRxiv - Biophysics 2022Quote: Cryo-EM grids were prepared by applying 3 μL of sample (at the native 1 nM concentration) on glow discharged holey gold grids (Quantifoil Cu 1.2/1.3 400 mesh). Excess sample was removed by blotting with filter paper for 4 sec prior to plunge-freezing in liquid ethane using a FEI Vitrobot Mark IV at 100% humidity and 4 °C ...
-
bioRxiv - Molecular Biology 2020Quote: Cryo-EM grids were prepared by applying 3 µL sample (at a protein concentration of 1 mg/ml) on glow-discharged holey gold grids (Quantifoil Au 1.2/1.3 300 mesh). Excess sample was removed by blotting with filter paper for 2-3 s before plunge-freezing in liquid ethane (cooled to −181 °C ...
-
bioRxiv - Biophysics 2024Quote: ... to produce a fiducial marker along with 0.01% NP-40 and 10 μM tubulin solution with BRB80 buffer and 1 mM GTP before the solution was dropped onto the grids (QUANTIFOIL R 1.2/1.3 Cu 200). The grids were blotted with vitrobot (Thermo Fisher Scientific ...
-
bioRxiv - Cell Biology 2024Quote: Vitrified grids were prepared by applying 3 µl of 1 uM complex sample to a freshly glow- discharged holey carbon grids (Quantifoil R1.2/1.3 Au 200 mesh). The sample was blotted for 3-5 s at 4 ℃ with 100% humidity and plunged-frozen in liquid nitrogen cooled ethane (FEI TM ...
-
bioRxiv - Immunology 2023Quote: ... respectively) and 3 μl were kept 5 min at RT until their application onto glow-discharged holey carbon grids (Quantifoil, Au 300 mesh, R 0.6/1). The grids were blotted and then plunged into liquid ethane using a FEI Vitrobot Mark IV at 20°C and 95% relative humidity ...
-
bioRxiv - Microbiology 2024Quote: ... 3.5 μL of protein sample at 0.15 mg/mL for the Gal/GalNAc lectin and at 0.2 mg/mL for lectin:scFv complexes were applied onto glow-discharged grids (Quantifoil R2/1 carbon film on a 300 gold mesh). After incubation for 10 s ...