bioRxiv - Molecular Biology 2022Quote: ... 4 μL of the cells were applied to a glow-discharged 200 mesh holey carbon grid copper grid (Quantifoil R1.2/3) and vitrified in a liquid ethane on a Vitrobot Mark IV (Thermo Scientific ...
-
bioRxiv - Biochemistry 2022Quote: ... stock solution was mixed with 3.5 µL of the KWOCA 4 sample and 3 µl were immediately loaded onto the UltrAuFoil R 1.2/1.3 grids (Au, 300-mesh; Quantifoil Micro Tools GmbH). Prior to sample loading the grids were subjected to Ar/O2 plasma cleaning for 10 s on a Solarus 950 plasma cleaner (Gatan) ...
-
bioRxiv - Neuroscience 2023Quote: ... each time was sequentially blotted 3 times to 300-mesh holey carbon Au R1.2/1.3 grids treated with 25s of glow discharge (Quantifoil, Micro Tools GmbH). Fluorinated Fos-choline-8 (0.65 mM ...
-
bioRxiv - Biochemistry 2024Quote: ... Cryo-EM grids were prepared by applying 3 µl of concentrated sample onto 400-mesh R1.2/1.3 UltrAuFoil grids (Quantifoil Micro Tools GmbH), which had rendered hydrophilic by glow discharging at 15mA for 60seconds with a PELCO EasyGlow device (TED PELLA ...
-
bioRxiv - Biochemistry 2022Quote: ... An aliquot of 3.5 μl of sample was placed on the glow-discharged cryo-EM grid (Quantifoil R1.2/1.3 or Quantifoil R2/1), blotted and plunge-frozen in liquid ethane using a Mark VI Vitrobot instrument maintained at 100% humidity with blot force 20 and blot time of 3 seconds ...
-
bioRxiv - Molecular Biology 2021Quote: ... DRD1-SKF81297-LY3154207-miniGs-Nb35 complex at the concentration of 13 mg mL−1 were applied individually onto glow-discharged holey carbon grids (Quantifoil, Au200 R1.2/1.3) in a Vitrobot chamber (FEI Vitrobot Mark IV) ...
-
bioRxiv - Biochemistry 2022Quote: Three microliters of Ct80S-RAC pull-out sample at 200 nM concentration was applied on holey carbon grids (Quantifoil R2/1 grid, Quantifoil Micro Tools, GmbH) and plunged-frozen into liquid ethane using a Vitrobot (FEI) ...
-
bioRxiv - Microbiology 2020Quote: Usually 5 μL of liquid culture (OD680 ~ 0.3) was pipetted onto holey carbon-coated copper grids (R2/1, 200 mesh, Quantifoil Micro Tools, Jena, Germany). The grids were blotted from the reverse side and immediately plunged into the liquid ethane at liquid nitrogen temperature atmosphere using a Vitrobot ...
-
bioRxiv - Microbiology 2020Quote: ... 3.5 microliters of the purified virus sample was pipetted onto a glow-discharged R2/1 Quantifoil grid (Quantifoil Micro Tools GmbH, Jena, Germany), blotted for 2.5 seconds ...
-
bioRxiv - Microbiology 2022Quote: ... 5 µl of bacteria diluted to OD = 0.15 in PBS were deposited on a glow-discharged Quantifoil R2/1 holey carbon grids (Quantifoil Micro Tools GmbH, Germany) and 3 µl gold particles (10 nm BSA tracer ...
-
bioRxiv - Biochemistry 2022Quote: ... three microliters of concentrated phage particles were added to a freshly glow-discharged Quantifoil R2/1 grid (Quantifoil Micro Tools GmbH, Großlöbicha, Germany) and plunge-frozen with a Vitrobot Mk IV into a 50:50 mixture of liquid ethane:propane52
-
bioRxiv - Microbiology 2022Quote: Three-microliter aliquots of all AdSDV capsid populations (~1 mg/mL) were applied to glow-discharged Quantifoil holey carbon grids with a thin layer of carbon (Quantifoil Micro Tools GmbH) and vitrified using a Vitrobot Mark IV (FEI ...
-
bioRxiv - Molecular Biology 2023Quote: ... a 4 µl sample of purified complex was applied to glow-discharged R2/1 300 mesh holey carbon copper grids (Quantifoil Micro Tools GmbH), using a conc ...
-
bioRxiv - Microbiology 2023Quote: 3 µL of the purified FL or truncated RSV NC sample were applied to a glow-discharged R2/1 300 mesh holey carbon copper grid (Quantifoil Micro Tools GmbH) and plunge-frozen in liquid ethane using a Vitrobot Mark IV (FEI ...
-
bioRxiv - Cell Biology 2023Quote: 4 ul of Nannochloropsis suspensions (4 x 107 cells mL−1) were pipetted onto a 300 mesh gold Quantifoil grid with 2um holes (Quantifoil Micro Tools, GmbH) and manually blotted from the opposite side in a Vitrobot Mark IV (ThermoFisher Scientific ...
-
bioRxiv - Immunology 2021Quote: ... by shaking at 1200 rpm for 5 minutes at 37°C using a plate shaker (Quantifoil Instruments) after stimulating with collagen at a range of concentrations ...
-
bioRxiv - Cell Biology 2022Quote: Vero-E6 were seeded on holey carbon film R 5/20 gold 200 mesh EM grids (Quantifoil Micro Tools GmbH ...
-
bioRxiv - Microbiology 2022Quote: ... 2.7 μl of freshly purified sample was applied onto glow-discharged (30 s, 5 mA) grids (Quantifoil R 0.6/1 300 mesh Cu or Ultrafoil 0.6/1 300 mesh Au ...
-
bioRxiv - Biochemistry 2023Quote: 3.5 μL of LRRK2RCKW:E11 complex was applied to glow-discharged UltraFoil 300 mesh R1.2/1.3 grids (Quantifoil) and incubated in a FEI Vitrobot IV at 4°C and 95% humidity for 20 sec ...
-
bioRxiv - Immunology 2022Quote: ... were incubated for 3 min at room temperature and then loaded onto the glow-discharged holy-carbon gold grids (Quantifoil, R1.2/1.3). The grids were washed using the buffer containing 20 mM HEPES ...
-
bioRxiv - Immunology 2019Quote: 4 μL of C5-OmCI-RaCI-CirpT1 in PBS (0.3 mg/ml) was applied to freshly glow-discharged (20 s, 15 mA) carbon-coated 200-mesh Cu grids (Quantifoil, R1.2/1.3). Following incubation for 10 s ...
-
bioRxiv - Biophysics 2021Quote: ... 3 μl of samples were applied onto a glow-discharged gold grids covered with holey carbon film (Quantifoil, 300 mesh 1.2/1.3) and blotted using a Vitrobot Mark IV (FEI Company ...
-
bioRxiv - Biochemistry 2022Quote: A 3 µL of the protein solutions was applied onto the glow-discharged holey carbon grids (Quantifoil Cu R1.2/1.3, 300 mesh). The grids were plunge-frozen in liquid ethane using a Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Molecular Biology 2021Quote: The purified tirzepatide–GLP-1R–Gs–Nb35 complex (3 μL at about 20 mg/mL) was applied to a glow-discharged holey carbon grid (Quantifoil R1.2/1.3) and blotted subsequently ...
-
bioRxiv - Molecular Biology 2023Quote: 3 µl of freshly purified NbE-µOR-Fab module complex were applied onto holey gold grids (Quantifoil UltrAuFoil R1.2/1.3, 300 mesh), front blotted for 3-4 seconds with 1 mm additional movement (95% humidity at 15°C ...
-
bioRxiv - Microbiology 2019Quote: 3 μl of purified complex at 1 to 3.6 mg/ml were applied to glow-discharged holey carbon-coated grids (Quantifoil 300 mesh, Au R1.2/1.3). Grids were blotted for 3 s at 100% humidity at 22 °C and frozen in liquid ethane using a Vitrobot Mark IV (FEI) ...
-
bioRxiv - Biochemistry 2022Quote: 4 µl aliquots of purified samples at A280 = 1 were applied onto glow-discharged holey carbon-coated grids (Quantifoil 300 mesh, Au R1.2/1.3), then adsorbed for 10 s ...
-
bioRxiv - Biophysics 2020Quote: Samples were prepared for CryoEM by applying 5 μl freshly purified Cx46/50-lipid nanodisc complex (∼2.5 mg mL-1) to a glow-discharged holey carbon grid (Quantifoil R 1.2/1.3, 400 mesh) for 10 seconds ...
-
Cryo-EM structure of a eukaryotic zinc transporter at a low pH suggests its Zn2+-releasing mechanismbioRxiv - Biochemistry 2022Quote: ... and 3 μl of the protein solution was applied to glow-discharged (45 s) Quantifoil R2/1 300-mesh gold grids (Quantifoil Micro Tools GmbH, Germany). The grids were blotted with standard Vitrobot filter paper for 2.5 s at 4 °C under 100% humidity and plunged into liquid ethane using a Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Bioengineering 2023Quote: ... 3.0 µl aliquots at a concentration of 0.87 or 1.0 mg/ml of the spikeD614G-binder sample or the spikeOmicron-binder sample were applied onto glow-discharged carbon-coated copper grids (Quantifoil R2/1, 400 mesh), blotted for 4.0-8.0 s ...
-
bioRxiv - Biochemistry 2023Quote: ... 3 μl of protein at a concentration of approximately 10 mg ml−1 were loaded onto glow-discharged holey carbon grids (Quantifoil Au 300 mesh R1.2/1.3 or Quantifoil Cu/Rh 300 mesh R1.2/1.3), after which ...
-
bioRxiv - Cell Biology 2022Quote: ... 3 μL of ∼100 nM (A260 4.0 or 6.0) mitoribosome sample was applied onto a glow-discharged (20 mA for 30 sec) holey-carbon grid (Quantifoil R2/1 copper, mesh 300) coated with continuous carbon (of ∼3 nm thickness ...
-
bioRxiv - Biochemistry 2024Quote: ... Approximately 3.5 μl of the solution was applied onto freshly glow-discharged and graphene oxide-coated TEM grids (Quantifoil R2/1, Cu 200 mesh) and plunge-frozen into liquid ethane by a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Biophysics 2021Quote: ... 2.8 ul of the mixture was applied onto glow discharged (5 mA, 20 sec) R1.2/1.3 holey carbon gold grids (300 mesh, Quantifoil) at 22°C and 100% humidity ...
-
bioRxiv - Microbiology 2023Quote: Four microliters of purified TilA-TslA-TlaA1-TlaA2 complex at 0.5 mg ml-1 in Buffer B (Supplementary Table 5) was applied onto glow-discharged (60 s, 30 mA) 300 mesh R1.2/1.3 Au grids (Quantifoil). Grids were blotted for 3 s with blot force of +15 at 10°C and 100% humidity ...
-
bioRxiv - Biochemistry 2023Quote: A 3.5 μL concentrated SPARTA sample was loaded onto a glow discharged UltrAuFoil 300 mesh R1.2/1.3 grids (Quantifoil) using a FEI Vitrobot at 4°C and 100% humidity ...
-
bioRxiv - Microbiology 2023Quote: ... 2.2µl of the purified mixture at a concentration of 0.5 mg/mL was applied to glow discharged (30 s at 25mA) grid (300 mesh 1.2/1.3, Quantifoil). The grids were blotted for 3.5 s before plunging into liquid ethane using Vitrobot MK4 (TFS ...
-
bioRxiv - Biophysics 2021Quote: ... 3 μL of the purified MC1R-Gs complex was applied to a glow-discharged holey carbon EM grid (Quantifoil, Au 300 R1.2/1.3) in a Vitrobot chamber (FEI Vitrobot Mark IV) ...
-
bioRxiv - Biochemistry 2020Quote: ... aliquots (3 μL) of the purified protein concentrated to ~ 10 mg/mL were placed on glow-discharged holey carbon grids (Quantifoil Au R1.2/1.3). For KCC3-DIOA samples ...
-
bioRxiv - Biophysics 2019Quote: ... A 3 μl aliquot of ribosomes at a concentration of 100 nM was placed on plasma-cleaned UltrAuFoil® grids (Quantifoil, R1.2/1.3) and vitrified using Vitrobot Mark IV (FEI company) ...
-
bioRxiv - Biochemistry 2022Quote: ... Peak fractions were collected and 3 μl of TSEN/pre-tRNA complex were applied onto freshly glow-discharged copper grids (Quantifoil, Cu R1.2/1.3) and plunge-frozen in liquid ethane using a Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Molecular Biology 2023Quote: ... A 2.5-3 μL aliquot of protein sample was dropped onto the glow discharged holey carbon grids (Quantifoil Au R1.2/1.3, 300 mesh), blotted with a Vitrobot Mark IV (ThemoFisher Scientific ...
-
bioRxiv - Plant Biology 2023Quote: Three µl of purified PSI at a concentration of 3 mg/ml was applied to the glow-discharged holey carbon grids (Cu QUANTIFOIL® R1.2/1.3), then vitrified using a Leica GP2 plunge freezer (2.5 s blot ...
-
bioRxiv - Biophysics 2020Quote: Three microliters of the apoferritin samples with 1.5 mg/ml or 0.2 mg/ml were applied onto glow-discharged 200-mesh R2/1 Quantifoil grids (used for the K3 dataset) or 200-mesh R2/1 Quantifoil grids coated with continuous carbon film (Quantifoil, used for the Falcon4 dataset), respectively ...
-
bioRxiv - Biophysics 2019Quote: ... 3.5 μl aliquots of the recombinant human TIM22 complex (7 mg ml-1) were dropped onto glow discharged holey carbon grids (Quantifoil Au R1.2/1.3, 300 mesh), blotted with a Vitrobot Mark IV (ThemoFisher Scientific ...
-
bioRxiv - Physiology 2021Quote: ... Aliquots of 1.25 – 1.5 μl RyR1-Nanodisc were applied onto each side of glow-discharged UltraAufoil −1.2/1.3 holey-gold (Quantifoil, Germany) with 300 TEM mesh ...
-
bioRxiv - Cell Biology 2019Quote: ... Liquid culture (5 μL, ~1000 cells/μL) was blotted onto carbon-coated 200-mesh copper grids (Quantifoil Micro Tools), which were then plunged into a liquid ethane-propane mixture using a Vitrobot Mark 4 (FEI Thermo Fisher) ...
-
bioRxiv - Biochemistry 2020Quote: An aliquot of 3 μL of SAM complex sample was applied to freshly glow-discharged holey carbon grid (Quantifoil R1.2/1.3, copper, 300 mesh). The grids were blotted for 6 s and plunge-frozen in liquid nitrogen-cooled liquid ethane using an FEI Vitrobot Mark IV plunger ...
-
bioRxiv - Neuroscience 2022Quote: Extracted filaments were centrifuged at 3,000 g for 3 min and applied to glow-discharged holey carbon gold grids (Quantifoil Au R1.2/1.3, 300 mesh), which were glow-discharged with an Edwards (S150B ...
-
bioRxiv - Neuroscience 2022Quote: ... Samples were centrifuged at 3,000 g for 3 min and applied to glow-discharged holey carbon gold grids (Quantifoil Au R1.2/1.3, 300 mesh), which were glow-discharged with an Edwards (S150B ...