Labshake search
Citations for Quantifoil Micro Tools :
551 - 600 of 674 citations for 6 OXO 1 2 DIHYDRO 6H PYRROLO 3 2 1 IJ QUINOLINE 5 CARBOXYLIC ACID since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cell Biology 2021Quote: K5/K14_1 cells were seeded on glow-discharged Collagen I coated holey carbon gold EM grids (Au R2/1, 200 mesh, Quantifoil) and incubated overnight at 32 °C and in 5% CO2 ...
-
bioRxiv - Cell Biology 2020Quote: Samples of concentrated TSCCFL were adsorbed to a thin film of graphene oxide deposited upon the surface of holey carbon copper grids (R2/1, 300 mesh, Quantifoil). Grids were blotted for 2-3 seconds before plunge freezing in liquid ethane using a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Microbiology 2023Quote: ... trehalose solution to mitigate crystalline ice formation and 4 μL of this mixture immediately applied to a R2/1 Cu 200 grid (Quantifoil), which had been glow-discharged for 1 min at 0.19 mbar and 20 mA in a PELCO easiGlow device shortly before use ...
-
bioRxiv - Biochemistry 2023Quote: ... 3 μl of protein at a concentration of approximately 10 mg ml−1 were loaded onto glow-discharged holey carbon grids (Quantifoil Au 300 mesh R1.2/1.3 or Quantifoil Cu/Rh 300 mesh R1.2/1.3) ...
-
bioRxiv - Biochemistry 2023Quote: ... 3 µl of the VIF-ΔT solution was applied onto glow-discharged holey carbon EM grids (Cu R2/1, 200 mesh, Quantifoil), which were subsequently blotted manually and plunge frozen in liquid ethane.
-
bioRxiv - Biochemistry 2023Quote: ... 2.8 µl of F-actin sample was applied to a glow-discharged R2/1 Cu 300 mesh holey-carbon grid (Quantifoil). Excess solution was blotted away and the grids were plunge frozen in liquid ethane or a liquid ethane/propane mixture using a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Biophysics 2023Quote: ... 4 µL fresh sample (0.48 mg/mL) was applied on glow-discharged Au holey carbon grids (Quantifoil R 0.6/1) and the following operation were the same as describe above for preparing the sample of gMCM8/9 complex.
-
bioRxiv - Cell Biology 2023Quote: 3 µl of prepared complexes at a concentration of approximately 1 mg/mL was applied to UltrAuFoil 300 mesh gold R1.2/1.3 grids (Quantifoil Micro Tools), freshly glow discharged with an Edwards S150B glow discharger for 1 min 15 sec ...
-
bioRxiv - Biophysics 2021Quote: ... aliquots (3 μL) of the concentrated protein were placed on glow-discharged holey carbon grids (Quantifoil Au R1.2/1.3) and blotted for 5 s ...
-
bioRxiv - Biophysics 2022Quote: Cryo-EM grids were prepared by applying 3 μL of protein to a glow-discharged QuantiAuFoil R1.2/1.3 300-mesh grid (Quantifoil, Germany) and blotted for 2.5 to 4 s under 100% humidity at 4 °C before plunging into liquid ethane using a Mark IV Vitrobot (FEI).
-
bioRxiv - Biochemistry 2020Quote: ... 3 μL of eluate (72 nM) was applied to a plasma-treated UltraAuFoil 1.2/1.3 grid (Quantifoil, Großlöbichau, Germany). The grids were hand blotted for 3 sec from the backside of the grid before being plunged into liquefied ethane.
-
bioRxiv - Biochemistry 2019Quote: ... 3 ul of sample were applied to glow-discharged holey carbon-coated grids (Quantifoil 300 mesh, Au R1.2/1.3), adsorbed for 5 s ...
-
bioRxiv - Biophysics 2022Quote: ... the pelleted cells resuspended in 100 μl NaH2PO4-NaOH pH 7.5 and a 3 μl drop adsorbed for 20 s to a carbon-coated copper grid (300 mesh, Quantifoil) that had been glow-discharged for 30 s at a current of 25 mA ...
-
bioRxiv - Microbiology 2022Quote: ... Purified BfpD was diluted to 4.5 mg/ml and 3 µl was applied to a glow-discharged 300 mesh UltraAufoil -1.2/1.3 holey-gold (Quantifoil, Germany). Grids were blotted for 2 s with ash-free Whatman® Grade 540 filter paper in a Vitrobot Mark IV (ThermoFisher Scientific ...
-
bioRxiv - Biophysics 2023Quote: ... 3 μL HA trimer (0.75 mg/ml) was applied to holey carbon grid (Quantifoil 400 mesh Au R1.2/1.3) which was glow discharged 30 s at 15 mA ...
-
bioRxiv - Biophysics 2023Quote: ... 3 μL apoferritin (0.67 mg/ml) was loaded on the holey carbon grids (Quantifoil 400 mesh Cu R1.2/1.3) which was glow discharged for 30s ...
-
bioRxiv - Biophysics 2023Quote: ... 3 μL HA trimer (0.75 mg/ml) was applied to holey carbon grid (Quantifoil 400 mesh Cu R1.2/1.3) which was glow discharged 30 s at 15 mA ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... All samples were pipetted at a volume of 3 µL onto UltrAufoil R1.2/1.3 300 mesh holey grids (Quantifoil, Germany) which had been glow discharged in air at 15 mA for 180 s using a Pelco EasyGlow ...
-
bioRxiv - Biophysics 2019Quote: An aliquot of 4 μl of 6 μM Ac-E46K α-syn fibril solution was applied to a glow-discharged holey carbon grid (Quantifoil R1.2/1.3, 300 mesh), blotted for 6.5 s ...
-
bioRxiv - Microbiology 2023Quote: Aliquots of 3.5 μL SbtA-SbtB (ΔT-loop) samples (∼6 mg/mL) were applied to the glow-discharged grids (Quantifoil holey carbon Cu R1.2/1.3 grid). Grids were blotted for 4.5 sec and plunge-frozen in liquid ethane vitrified by liquid nitrogen using Vitrobot Mark IV (FEI Company ...
-
bioRxiv - Biochemistry 2023Quote: ... Four microliters of purified Cx36 proteins (4-6 mg/ml) were applied onto a negatively glow-discharged holey carbon grid (Quantifoil R1.2/1.3 Cu 300 mesh). For samples involving Cx36-WT ...
-
bioRxiv - Biophysics 2019Quote: ... Approximately 5 µL of sample (diluted if necessary) was placed on a copper grid (Quantifoil® S7/2 Cu 400 mesh ...
-
bioRxiv - Bioengineering 2022Quote: ... A total of 3.5 μL of TP–AG treated MT samples was applied to a glow discharged holey carbon grid (Quantifoil R2/1). The grids were blotted ...
-
bioRxiv - Plant Biology 2020Quote: ... 4 μL of cell culture was blotted onto R 1/4 SiO2-coated 200-mesh gold EM grids (Quantifoil Micro Tools) and plunge frozen in a liquid ethane/propane mixture ...
-
bioRxiv - Cell Biology 2021Quote: ... a thin layer of homemade continuous carbon was floated on top of individual Quantifoil R3.5/1 200 mesh gold grids (Quantifoil Micro Tools). After drying ...
-
bioRxiv - Cell Biology 2020Quote: ... 3 μl of samples were applied to glow-discharged Quantifoil R 0.6/1 and R 1.2/1.3 grids (Quantifoil Micro tools GmbH, Germany), blotted for 3 s and then flash frozen in liquid ethane using the automatic plunge freezer EM GP2 at 100% relative humidity ...
-
bioRxiv - Cell Biology 2021Quote: MEFs were grown to ~80% confluency on glow-discharged holey carbon EM grids (R2/1, Au 200 mesh; Quantifoil, Jena, Germany) prior to preparation for cryo-ET analysis ...
-
bioRxiv - Molecular Biology 2021Quote: ... cells in suspension (4 μl of ~1,000 cells per μl) were blotted onto R2/1 carbon-coated 200-mesh copper grids (Quantifoil Micro Tools) and plunge frozen in a liquid ethane/propane mixture ...
-
bioRxiv - Immunology 2022Quote: A 3.5 μL sample of concentrated pNO-decorated CLPs was applied to negatively glow discharged (25 mA, 40 s) R3.5/1 quantifoil copper grids (Quantifoil Micro Tools). The excess of solution was blotted using a Vitrobot Mark IV (FEI ...
-
bioRxiv - Biochemistry 2023Quote: ... at a concentration of around 2.5 mg ml−1 were applied to glow-discharged 300-mesh Au grids (Quantifoil, R1.2/1.3). Excessive sample was removed by blotting with filter paper for 3.5 s before plunge-freezing in liquid ethane using a FEI Vitrobot Mark IV at 100% humidity and 8 °C.
-
bioRxiv - Biochemistry 2023Quote: MEFs were grown to ∼80% confluency on glow-discharged holey carbon EM grids (R2/1, Au 200 mesh; Quantifoil, Jena, Germany) prior to preparation for cryo-ET analysis ...
-
bioRxiv - Pathology 2019Quote: ... of the purified MNV infectious particles and HNV GII.3 VLP were placed onto R 1.2/1.3 Quantifoil grids (Quantifoil Micro Tools) coated with a thin carbon membrane that were glow-discharged using a plasma ion bombarder (PIB-10 ...
-
bioRxiv - Pharmacology and Toxicology 2021Quote: Samples (3 μL) were applied to a glow-discharged UltrAufoil R1.2/1.3 300 mesh holey grid (Quantifoil GmbH, Großlöbichau, Germany) and were flash frozen in liquid ethane using the Vitrobot mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Immunology 2022Quote: ... 3 μL of the mixture was applied to a glow-discharge holey carbon grids (Quantifoil, Cu 200 mesh, R1.2/1.3). The grid was blotted for 4.5 s in 100% humidity before being flash frozen in liquid ethane by using a Vitrobot Mark IV (Thermo Fisher) ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... 3 μl of the samples were applied to glow-discharged holey carbon EM grids (Quantifoil 300 copper mesh, R1.2/1.3) in an EM-GP2 plunge freezer (Leica) ...
-
bioRxiv - Immunology 2023Quote: ... 3 μL of each LNP sample was deposited onto a holey carbon grid that was glow-discharged (Quantifoil R1.2/1.3) and vitrificated using a Vitrobot Mark IV System (FEI/Thermo Scientific ...
-
bioRxiv - Immunology 2023Quote: ... 3 μL of the purified complex were loaded onto a glow-discharged holey grid (Quantifoil Au 300 mesh R1.2/1.3), and subsequently were plunge-frozen in liquid ethane using Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Microbiology 2020Quote: ... of purified proteins of SARS-CoV2-ST or SARS-CoV2-STN were loaded onto glow-discharged (60 s at 20 mA) holey carbon Quantifoil grids (R2/1, 200 mesh, Quantifoil Micro Tools) using a Vitrobot Mark IV (ThermoFisher Scientific ...
-
bioRxiv - Plant Biology 2019Quote: ... 4 µL of mat3-4 cell culture was blotted onto R2/1 carbon-coated 200-mesh copper EM grids (Quantifoil Micro Tools) and plunge frozen in a liquid ethane/propane mixture ...
-
bioRxiv - Microbiology 2019Quote: Cells of strain Pla133T were mixed with the same volume of BSA-stabilized 15 nm colloidal gold solution (Aurion) and placed on holey carbon-coated 200 mesh copper grids (R2/1, Quantifoil, Jena, Germany) immediately before thin-film vitrification by plunge-freezing in liquid propane (63%)/ethane (37% ...
-
bioRxiv - Biochemistry 2022Quote: ... Protein-DNA complexes were applied to ultra-gold foil grids with holey gold support and 300 mesh size (R 0.6/1,Quantifoil Micro Tools GmbH); grids were flash-frozen as described [21] and were stored in liquid nitrogen until use.
-
bioRxiv - Cell Biology 2023Quote: ... 4 µL of cell suspension was applied on 200-mesh R ¼ SiO2-film covered gold grids or 200-mesh R2/1 carbon-film covered copper grids (Quantifoil Micro Tools) (for P ...
-
bioRxiv - Microbiology 2023Quote: ... 3µL of each sample was was pipetted onto a freshly glow-discharged Quantifoil R2/1 grid (Quantifoil Micro Tools GmbH, Großlöbicha, Germany), then blotted to remove excess sample and plunge-frozen into a mixture of liquid ethane and propane cooled in a bath of liquid nitrogen using a Vitrobot Mk 4 cryo-plunger (41) ...
-
bioRxiv - Cell Biology 2024Quote: ... the sample was gently resuspended and 4 µl was transferred to a glow-discharged holey carbon R2/1 copper grid (Quantifoil Micro Tools) suspended in the chamber of a Vitrobot (Thermo Fisher Scientific) ...
-
bioRxiv - Biochemistry 2024Quote: ... Peak fractions were concentrated to ∼3.2 mg/mL and 3.5 μL of concentrated sample immediately applied to a Quantifoil R2/1 300 copper mesh grid (Quantifoil Micro Tools GmbH), which had been glow discharged in a GloQube Plus glow discharger for 45 seconds at 25 mA and coated with graphene oxide (Sigma Aldrich ...
-
A distinctive ligand recognition mechanism by the human vasoactive intestinal polypeptide receptor 2bioRxiv - Molecular Biology 2021Quote: The purified PACAP27–VIP2R–Gs complex (3 μL at 3.7 mg per mL) was applied to glow-discharged holey carbon grids (Quantifoil R1.2/1.3). Vitrification was performed using a Vitrobot Mark IV (ThermoFisher Scientific ...
-
bioRxiv - Pharmacology and Toxicology 2020Quote: Samples (3 µL) were applied to a glow-discharged UltrAuFoil R1.2/1.3 Au 300 gold foil grids (Quantifoil GmbH, Großlöbichau, Germany) and were flash frozen in liquid ethane using a Vitrobot mark IV (Thermo Fisher Scientific ...
-
Structure of the Human Signal Peptidase Complex Reveals the Determinants for Signal Peptide CleavagebioRxiv - Biochemistry 2020Quote: ... 3 µL samples were applied to freshly glow-discharged Cu 200 Holey Carbon R1.2/1.3 grids (Quantifoil, for samples without FFosC), or Cu 200 Holey Carbon R2/1 grids (Quantifoil ...
-
bioRxiv - Biochemistry 2021Quote: The purified TIP39–PTH2R–Gs complex (3 μL at 8.5 mg per mL) was applied on a glow-discharged holey carbon grid (Quantifoil R1.2/1.3). Vitrification was performed using a Vitrobot Mark IV (ThermoFisher Scientific ...
-
bioRxiv - Molecular Biology 2022Quote: ... The complex (3 μL) was quickly applied on a glow-discharged UltraAuFoil R1.2/1.3 300 mesh holey Au grids (Quantifoil Micro Tools GmbH), blotted with Vitrobot Mark IV (FEI) ...