Labshake search
Citations for Quantifoil Micro Tools :
601 - 650 of 719 citations for 1 2 Chloropyridin 3 yl 3 3 dimethylazetidin 2 one since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Molecular Biology 2021Quote: ... applied to glow-discharged holey carbon grids (R2/1, 200 mesh, Au, Quantifoil, Germany), and the NE was spread onto the grid by fine glass needles ...
-
bioRxiv - Cell Biology 2020Quote: ... reinhardtii cells were deposited onto 200-mesh copper EM (R2/1, Quantifoil Micro Tools) and vitrified using a Vitrobot Mark 4 (FEI Thermo Fisher Scientific) ...
-
Mechanism of actin-dependent activation of nucleotidyl cyclase toxins from bacterial human pathogensbioRxiv - Biochemistry 2021Quote: ... were applied onto a freshly glow-discharged copper R2/1 300 mesh grid (Quantifoil), blotted for 3 s on both sides with blotting force −3 and plunge-frozen in liquid ethane using the Vitrobot Mark IV system (Thermo Fisher Scientific ...
-
bioRxiv - Molecular Biology 2021Quote: ... applied to glow-discharged holey carbon grids (R2/1, 200 mesh, Au, Quantifoil, Germany), and the NE was spread onto the grid by fine glass needles ...
-
bioRxiv - Pathology 2023Quote: ... bombycis spores (1×105 spores/mL) were placed on nickel grids (Quantifoil, Beijing, China) for 15 min and germinated in 0.1 M KOH for 30 min at 30°C ...
-
bioRxiv - Molecular Biology 2023Quote: ... UltrAuFoil R1.2/1.3 or R0.6/1 300 mesh gold grids (Quantifoil Micro Tools GmbH) were glow discharged on both sides for 1.5 mins on a PELCO easiGlow glow discharge unit (20 mA ...
-
bioRxiv - Biophysics 2024Quote: Plunge freezing of cells was performed on R2/1 SiO2 copper 200 mesh (Quantifoil) grids ...
-
bioRxiv - Microbiology 2024Quote: ... was pipetted onto a holey carbon-coated copper grid (R2/1, mesh 200; Quantifoil), blotted and vitrified by plunging into liquid ethane using a Vitrobot Mark IV (FEI) ...
-
bioRxiv - Biophysics 2021Quote: ... 4 μl of cell suspension was applied to holey carbon R2/1 Cu grids (Quantifoil) and plunge-frozen on a Vitrobot Mark IV (Thermo Fisher Scientific ...
-
bioRxiv - Microbiology 2021Quote: ... before being vitrified on carbon-coated Au grids (R06/1, 200 mesh; Quantifoil, Jena, Germany).
-
bioRxiv - Cell Biology 2021Quote: For each glow-discharged copper grid (Quantifoil Cu 200 mesh, holy carbon film R2/1) 4 μl of the supernatant were applied ...
-
bioRxiv - Molecular Biology 2021Quote: ... Ribosome–EF-G complexes were applied to EM grids (Quantifoil 3.5/1 μm, Jena Bioscience) covered with pre-floated continuous carbon ...
-
Structure of the Human Signal Peptidase Complex Reveals the Determinants for Signal Peptide CleavagebioRxiv - Biochemistry 2020Quote: ... or Cu 200 Holey Carbon R2/1 grids (Quantifoil, for samples containing 1.5 mM FFosC). In both cases ...
-
bioRxiv - Cell Biology 2024Quote: Quantifoil R2/1 or SiO2 R1/4 gold grids (both Quantifoil Mirco Tools GmbH, Germany) were briefly washed in chloroform and placed on drops of poly-D-lysine (100 µg/ml) ...
-
bioRxiv - Molecular Biology 2022Quote: ... The sample was applied onto freshly glow-discharged Au 300 mesh R0.6/1 grids (Quantifoil) in a Vitrobot Mark IV at 4°C ...
-
bioRxiv - Biochemistry 2024Quote: ... The mixture was applied to glow-discharged holey carbon grid (Quantifoil, R2/1, 300 mesh) mounted in a Vitrobot Mark IV (ThermoFisher) ...
-
bioRxiv - Molecular Biology 2021Quote: ... The sample-covered carbon was then adsorbed to an EM grid (Quantifoil R3.5/1, Jena Bioscience) and blotted for 9 s using a Vitrobot Mark IV (ThermoFisher ...
-
Mechanism of actin-dependent activation of nucleotidyl cyclase toxins from bacterial human pathogensbioRxiv - Biochemistry 2021Quote: ... the mixture was applied onto a freshly glow-discharged copper R2/1 300 mesh grid (Quantifoil), blotted for 3 s on both sides with blotting force −5 and plunge-frozen in liquid ethane using the Vitrobot Mark IV system (Thermo Fisher Scientific ...
-
bioRxiv - Microbiology 2024Quote: ... 3.5 μL of the culture were applied onto glow-discharged copper EM grids (R2/1, Quantifoil), automatically blotted and plunged into liquid ethane/propane (Tivol et al ...
-
bioRxiv - Molecular Biology 2024Quote: ... 4 µl of the sample was applied onto freshly glow-discharged R2/1 carbon grids (Quantifoil), followed by grid blotting for 4 s and plunging into liquid ethane using a Vitrobot Mark IV (FEI ...
-
bioRxiv - Microbiology 2021Quote: ... and 5 μl of the washed cells were introduced to Au grids (R2/1, 200 mesh; Quantifoil). The grids were fixed in 4% PFA (in TBS ...
-
bioRxiv - Biophysics 2022Quote: A volume of 4-7 µl of cells were deposited on R2/1 Cu 200 grids (Quantifoil) that had been glow-discharged for 1 min at 0.19 mbar and 20 mA in a PELCO easiGlow device shortly before use ...
-
bioRxiv - Biochemistry 2022Quote: ... Solutions were adjusted to OD600≈10 and applied to carbon-coated holey copper grids (Quantifoil R2/1). Grids were glow-discharged for 30 s in oxygen/argon atmosphere of a plasma cleaner (Gatan Solarus 950 ...
-
bioRxiv - Microbiology 2021Quote: ... 200-mesh copper grid with holey carbon film (R2/1 Cu 200, Quantifoil Micro Tools GmbH, Germany). The sample was blotted with filter paper and immediately plunge frozen in liquid ethane ...
-
bioRxiv - Microbiology 2020Quote: ... CryoET samples were prepared using copper grids with holey carbon support film (200 mesh, R2/1, Quantifoil). The grids were glow-discharged for 30 seconds before we deposited 5 μL cell solution on them ...
-
bioRxiv - Neuroscience 2021Quote: Sample volumes of 3.5 µl were applied to freshly glow-discharged R3.5/1 holey carbon grids (Quantifoil) and vitrified using a Mark IV Vitrobot (Thermo Fischer Scientific ...
-
bioRxiv - Neuroscience 2022Quote: Primary cultured neurons were seeded onto holey gold EM grids (Quantifoil R 1/4 gold 200 mesh). The fiducial marker solution was prepared as for neocortical synaptosomes ...
-
bioRxiv - Cell Biology 2024Quote: ... Quantifoil Holey SiO2 R 1/4 Au 200 mesh EM grids (Quantifoil Micro Tools #N1-s13nAi20-01) were glow discharged on both sides in a Pelco easyglow for 45 s at 0.37 mBar and 15 mA ...
-
bioRxiv - Biochemistry 2022Quote: TEM gold grids with Holey Carbon support film (Quantifoil Micro Tools GmbH, Au 200 mesh R3.5/1) were glow-discharged in a plasma cleaner (Diener electronic GmbH ...
-
bioRxiv - Biophysics 2023Quote: ... 10 µL of samples were placed on top of a glow-discharged Au200 R2/1 grids (Quantifoil) and incubated in a 100%-humidity controlled environment ...
-
bioRxiv - Biochemistry 2021Quote: ... 3 microlitres of undiluted eluate and of eluate which was diluted 1:2 or 1:4 in buffer A200 were blotted onto holey carbon R 1.2/1.3 copper 300 mesh grids (Quantifoil) and vitrified in liquid ethane using a Vitrobot MarkIV device (Thermofisher) ...
-
bioRxiv - Molecular Biology 2020Quote: ... applied to plasma-cleaned 200-mesh Cu R2/1 or 300-mesh Au R1.2/1.3 grids (both Quantifoil) and plunge-frozen in liquid ethane ...
-
bioRxiv - Biophysics 2020Quote: ... with 2.3 M sucrose9 and transferred to holy carbon finder grids (R3.5/1 Copper NH2 - Quantifoil, Jena, Germany). Sections were stored at 4 °C until further processing.
-
bioRxiv - Biochemistry 2021Quote: ... 1 mM TCEP and adsorbed to glow-discharged holey carbon-coated grids (Quantifoil 300 mesh, Au R1.2/1.3) for 10 s ...
-
bioRxiv - Microbiology 2020Quote: ... Five microliters of cell suspension were deposited on holey carbon electron microscopy grids (200 mesh, R2/1, Quantifoil), which had been freshly glow-discharged for ∼30 seconds ...
-
bioRxiv - Immunology 2021Quote: ... The resulting EV suspension was spotted onto a glow discharged holey carbon mesh copper grids (Quantifoil, R2/1) and incubated at room temperature for 4 mins 45 seconds before 5μL of 0.22μm filtered 2% (v/v ...
-
bioRxiv - Molecular Biology 2023Quote: ... 1.5 µL of fibril solution was applied to freshly glow-discharged R2/1 holey carbon film grids (Quantifoil). After the grids were blotted for 12 seconds at a blot force of 10 ...
-
bioRxiv - Biophysics 2023Quote: Three microliters of the purified CLC-2 or CLC-2/AK-42 mixture was applied to glow-discharged copper Quantifoil R1.2/1.3 or R2/1 holey carbon grids (Quantifoil). Grids were incubated for 15 s ...
-
bioRxiv - Biochemistry 2024Quote: ... 4 uL of the concentrated sample was applied to freshly glow-discharged R2/1 holey carbon grids (Quantifoil), blotted with blot force of 5 for 5 s using a Vitrobot Mark IV (Thermo Fisher ...
-
bioRxiv - Biochemistry 2023Quote: ... 3.5 μL of HTNV-L at 1 µM was deposited on glow-discharged (25 mA, 45 s) UltraAuFoil 300 mesh R1.2/1.3 grids (Quantifoil). The grid was blotted for 3s (blot force 1 ...
-
bioRxiv - Microbiology 2022Quote: Cryo-ET samples were prepared using copper grids with holey carbon support film (200 mesh, R2/1, Quantifoil). The grids were glow-discharged for ∼30 s before depositing 5 µl of cell solution onto them ...
-
bioRxiv - Biophysics 2023Quote: ... Aliquots of 4 μl of protein samples (0.3 mg ml-1 or ∼6 μM) were applied to glow-discharged R1.2/1.3 200 Cu mesh grids (Quantifoil). After 30 s ...
-
bioRxiv - Biochemistry 2024Quote: ... The carbon was then fished with a glow-discharged holey carbon grid (Quantifoil R3.5/1, copper, mesh 200). 4 µL of dialysis buffer was added to the grid ...
-
bioRxiv - Biophysics 2024Quote: ... 200 mesh gold Quantifoil R2/1 grids with a SiO2 support layer (Quantifoil, Cat No N1-S15nAu20-01) were glow discharged and treated with PLL-g-PEG (SuSoS ...
-
bioRxiv - Microbiology 2020Quote: ... mobilis Zm4 or Zm6 cells were applied to glow-discharged holey carbon grids (Quantifoil R3.5/1 Cu 200-mesh) and plunge-frozen in liquid ethane using a Vitrobot Mark IV (Thermo Fisher Scientific) ...
-
bioRxiv - Biophysics 2021Quote: ... A volume of 4 μL cell suspension at a concentration of 3.07-3.5×107 cells/ml was directly applied to glow-discharged holey carbon R2/1 Cu 200 mesh grids (Quantifoil). After 5 s back-side blotting ...
-
bioRxiv - Molecular Biology 2021Quote: Purified mtLSU or 55S mitoribosome samples (4 μL) were applied to freshly glow discharged R 3.5/1 holey carbon grids (Quantifoil) that were precoated with a 2-3 nm carbon layer using a Leica EM ACE600 coater ...
-
bioRxiv - Molecular Biology 2022Quote: ... 3 μL of sample were pipetted onto a freshly glow discharged (PELCO easiGlow, 25 mA, 45 sec) 300 mesh Cu 0.6/1 grid (Quantifoil) and blotted for 4 s at strength 4 ...
-
bioRxiv - Microbiology 2024Quote: ... the sample was applied to a holey carbon-coated copper grid for electron microscopy (R2/1, mesh 200; Quantifoil), blotted and vitrified by plunging into liquid ethane using a Vitrobot Mark IV (FEI) ...
-
bioRxiv - Immunology 2024Quote: ... The complex (1 mg/mL) was then applied onto the glow-discharged holy-carbon gold grids (Quantifoil, R1.2/1.3) using an FEI Vitrobot IV ...