Labshake search
Citations for Interscience :
1 - 50 of 88 citations since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Evolutionary Biology 2024Quote: ... This latter plate (called hereafter « inoculation 96 deepwells plate ») contained approximately 10¹⁰ CFU/mL (estimation from CFU/mL (estimation from easySpiral plater; #412 000, Interscience, Saint-Nom-la-Bretèche, France) and was then stored at 4°C and used when needed to inoculate new 96-well plates.
-
bioRxiv - Microbiology 2024Quote: ... The sample was homogenized using a stomacher (Interscience Laboratories, United States) for 1 minute at 230 rpm ...
-
bioRxiv - Cell Biology 2024Quote: ... Colony counts were measured using the Scan 1200 (Interscience, France) equipment ...
-
bioRxiv - Molecular Biology 2024Quote: ... Cells were diluted and plated before the first cell division using the automatic serial diluter and plater EasySpiral Dilute (Interscience) and were counted using the Scan 1200 automatic colony counter (Interscience).
-
bioRxiv - Molecular Biology 2024Quote: ... and were counted using the Scan 1200 automatic colony counter (Interscience).
-
bioRxiv - Microbiology 2024Quote: ... followed by homogenization in BagPage+ 100 mL filter bags (Interscience) with a laboratory blender (Seward ...
-
bioRxiv - Microbiology 2023Quote: ... the cucamelons were removed with sterile tweezers and placed into a stomacher filter bag with 40 mL of PBS and homogenised with a paddle blender (BagMixer 400, Interscience, France) for 2 minutes ...
-
bioRxiv - Microbiology 2023Quote: ... Whole blood was plated onto TSAII plates using an automatic serial diluter and plater (Interscience Laboratories, Woburn, MA). After the plates were incubated at 37°C for 16-24 hrs ...
-
bioRxiv - Microbiology 2023Quote: ... Bacterial colonies were enumerated using an automated colony counter (Interscience Laboratories, Woburn, MA). Bacterial colonies having morphology typical of B ...
-
bioRxiv - Genetics 2023Quote: Pictures were taken using a Scan 1200 (Interscience). Petri dishes grown on cheese were analyzed using IRIS 133 which measured Integral opacity scores ...
-
bioRxiv - Microbiology 2023Quote: ... and the number of CFUs was assessed using an automatic colony counter Scan1200 (Interscience, Saint-Nom-la-Breteche, France) and its counting software.
-
bioRxiv - Microbiology 2023Quote: ... The homogenates were diluted at the appropriate concentration and plated on MRS Agar using an Easyspiral automatic plater (Interscience, Saint-Nom-la-Breteche, France). Plates were incubated at 37°C for 48h ...
-
bioRxiv - Microbiology 2023Quote: ... bacterial colonies were enumerated using an automatic colony counter (Interscience Laboratories, Woburn, MA). Bacterial colonies having morphology typical of B ...
-
bioRxiv - Microbiology 2023Quote: ... cells were washed twice with PBS and incubated and lysed by osmotic shock in sterile water and lysates were plated on tryptone soy agar plates (Biomérieux) using the Easy Spiral® automaton (Interscience, Saint-Nom-la-Bretèche, France). CFU were counted after 18 hours of incubation at 37°C and results were presented as CFU for 100,000 cells.
-
bioRxiv - Cancer Biology 2023Quote: ... and colonies containing >50 cells were counted on a plate scanner (Interscience).
-
bioRxiv - Evolutionary Biology 2023Quote: ... Ten microliter of the 10- 3 dilution was directly injected into the stem of a healthy plant and 50 µl of the 10-4 and 10-6 dilutions were plated on BG complete medium without triphenyltetrazolium chloride using an automatic spiral plater (easySpiral, Interscience, France). Green and red colonies were visualized and enumerated using a fluorescence stereo zoom microscope (Axio Zoom.V16 ...
-
bioRxiv - Microbiology 2023Quote: ... KH2PO4 1.8 mM) and 50% glycerol and homogenized in BagPage® 100 mL filter bags (Interscience, Saint-Nom-la-Bretèche, France) with a laboratory stomacher (Stomacher 80 ...
-
bioRxiv - Microbiology 2023Quote: ... the colonies were counted by using the Scan® 500 Automatic colony counter (Ref 436 000, INTERSCIENCE, France; software version 8.6.1) to calculate CFUs.
-
bioRxiv - Microbiology 2023Quote: ... and spread via exponential mode of easySpiral Dilute® (Ref. 414 000, INTERSCIENCE, France) on 523 media containing 30 μg/ml gentamycin to recover the prey.
-
bioRxiv - Microbiology 2023Quote: ... the supernatant was transferred to a new microcentrifuge tube and spread on 523 agar plates via exponential mode of easySpiral Dilute® (Ref. 414 000, INTERSCIENCE, France). After growth at 25°C for two days ...
-
bioRxiv - Cell Biology 2023Quote: ... Plates were incubated overnight at 37 °C and then colonies were counted using an automated colony counter (Scan4000, Interscience, Saint Nom la Brétèche, France).
-
bioRxiv - Microbiology 2023Quote: ... We ensured the complete homogenization of each sourdough starter by pouring the dough into a sterile bag and homogenizing it using the BagMixer 5000 (Interscience, Saint Nom la Brétèche, France) using default parameters for 60 seconds ...
-
bioRxiv - Microbiology 2023Quote: CFUs were quantified by serial dilution on LB plates containing the appropriate antibiotics and counted with Scan 500 automatic colony counter (Interscience).
-
bioRxiv - Plant Biology 2023Quote: ... ambient and canopy temperature of plants in all six conditions was recorded by using AGRI-THERM IIITM infra-red sensing instrument (Everest Interscience Inc., USA) at mid-day on the 70th day ...
-
bioRxiv - Plant Biology 2023Quote: ... ambient and canopy temperature of both control and stressed plants was recorded by using AGRI-THERM IIITM infra-red sensing instrument (Everest Interscience Inc., USA). The difference in the two readings gives the Crop Canopy Air Temperature Difference (CCATD).
-
bioRxiv - Neuroscience 2023Quote: ... Samples were homogenized and grossly filtered in a laboratory blender (Bag Mixer, Interscience, France)65 as follows ...
-
bioRxiv - Microbiology 2023Quote: ... and plates were imaged using a Scan 4000 colony counter (Interscience).
-
bioRxiv - Cell Biology 2023Quote: ... (Interscience, Roubaix, France). Colony Forming Units (CFU ...
-
bioRxiv - Microbiology 2023Quote: ... easySpiral Dilute (Interscience, France).
-
bioRxiv - Neuroscience 2023Quote: ... and then homogenized using a stomacher machine (BagMixer 400 P, Interscience, France). The resulting slurry was double encapsulated in HydroxyPropylMethylCellulose capsules (Capsugel ...
-
bioRxiv - Cell Biology 2023Quote: ... Sample aliquots of 50 µl were plated in duplicate on 90 mm agar plates using spiral plate inoculator EasySpiral (Interscience, Saint Nom, France) and incubated aerobically at 37°C for 24–48 h ...
-
bioRxiv - Microbiology 2022Quote: ... Blood agar plates were then photographed with a Scan500 imager (Interscience). The assay was repeated three times.
-
YAP promotes cell-autonomous immune responses to tackle intracellular Staphylococcus aureus in vitrobioRxiv - Cell Biology 2022Quote: ... and a colony counter (Scan 4000, Interscience).
-
YAP promotes cell-autonomous immune responses to tackle intracellular Staphylococcus aureus in vitrobioRxiv - Cell Biology 2022Quote: ... aureus load of cell lysates was quantified on an agar plate using an automatic plate seeder (EasySpiral Dilute, Interscience, St-Nom la Bretèche, France) and a colony counter (Scan 4000 ...
-
bioRxiv - Microbiology 2022Quote: ... Bacterial cultures were serially diluted in saline buffer and 100 μl of dilution at OD600 of 0.01 (an estimate of 107 bacteria/ml) were spread evenly using the automatic plater EasySpiral (Interscience) on freshly prepared TSA plates containing IMP at 4-fold ...
-
bioRxiv - Evolutionary Biology 2022Quote: ... Dilutions of nodule crushes were plated on selective solid medium using an easySpiral automatic plater (Interscience). Two days after incubation at 28°C ...
-
bioRxiv - Evolutionary Biology 2022Quote: ... diluting and plating on selective medium using an easySpiral automatic plater (Interscience). Two days after incubation at 28°C ...
-
bioRxiv - Evolutionary Biology 2022Quote: ... bacteria present in the culture medium were diluted and plated on selective solid medium using an easySpiral automatic plater (Interscience). Bacteria attached to the roots were resuspended in 4 ml of sterile water by strongly vortexing for 1 minute ...
-
bioRxiv - Evolutionary Biology 2022Quote: ... diluted and spread on selective solid medium using an easySpiral automatic plater (Interscience). After 2-day incubation at 28°C ...
-
bioRxiv - Genetics 2022Quote: ... The LT and SC data were recorded from the surface of the uppermost fully expanded young leaf between 11:00 am to 14:00 pm using a FLUKE precision infrared thermometer (Everest Interscience, Tucson, AZ, USA) and a hand-held leaf porometer (Decagon Devices® ...
-
bioRxiv - Microbiology 2022Quote: ... Diluted samples were homogenized in a lab blender (Interscience 032230), aliquoted ...
-
bioRxiv - Microbiology 2022Quote: ... samples were transferred into an anaerobic chamber (Coy) and placed into filtered blender bags (Interscience). Samples were then diluted in 1x PBS and glycerol to a final 20% w/v fecal slurry containing 15% glycerol ...
-
bioRxiv - Microbiology 2022Quote: ... Each plaque image was taken using scan1200 (Interscience, Montpellier, France) for measuring plaque sizes ...
-
bioRxiv - Microbiology 2022Quote: ... pneumophila were quantified after 5 days-incubation using Scan® 1200 Automatic HD colony counter (Interscience, France). Comparison of survival curves was performed using Log-rank (Mantel-Cox ...
-
bioRxiv - Microbiology 2022Quote: ... 10-4 and 10-6 were automatically plated using easySpiral® automatic plater (Interscience, France) in triplicates on BCYE agar ...
-
bioRxiv - Genetics 2022Quote: ... for 1 h at 37°C for recovery and then plated onto 37 Φ150 LB agar plates containing kanamycin with an EasySpiral Pro (Interscience). Generally ...
-
bioRxiv - Molecular Biology 2021Quote: ... and were counted using the Scan 1200 automatic colony counter (Interscience). No differences were observed when we used FBG or EC derivative strains.
-
bioRxiv - Molecular Biology 2021Quote: ... Cells were diluted and plated before the first cell division using the automatic serial diluter and plater EasySpiral Dilute (Interscience) and were counted using the Scan 1200 automatic colony counter (Interscience) ...
-
bioRxiv - Cell Biology 2021Quote: ... Colonies were then counted with an automatic colony counter (Scan4000, Interscience).
-
bioRxiv - Systems Biology 2021Quote: ... Cell numbers in a given volume of the same diluted culture were enumerated using plating and automatic CFU counter (Scan 1200, Interscience, Saint Nom, France).