Labshake search
Citations for Covaris :
1 - 50 of 180 citations for 6 Chloro 2 3 4 5 tetrahydro 7 8 dimethoxy 1 4 methoxyphenyl 1H 3 benzazepine since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cell Biology 2019Quote: ... DNA (3 μg) was sonicated at intensity 4 for 200 cycles per burst for 55 s (Covaris S2), and DNA fragments were end-repaired ...
-
bioRxiv - Cancer Biology 2023Quote: ... 10mM hydroxyflutamide for 3 or 16 hours and nuclear fractions were sonicated using a waterbath sonicator at 4°C (Covaris). Supernatants were precleared using Protein G DynaBeads (Thermo ...
-
bioRxiv - Plant Biology 2023Quote: ... and chromatin sonicated using the Diagenode Bioruptor (set to high intensity, 3 times 7 cyles (30sec ON / 30 sec OFF) or the S220 Focused-ultrasonicator (Covaris) for 20 min at peak power 110 W ...
-
bioRxiv - Molecular Biology 2020Quote: ... 1-3 million nuclei were sonicated in 130μl microtube by Covaris M220 instrument (Power ...
-
bioRxiv - Biochemistry 2023Quote: ... Cell suspensions were sonicated for 3 minutes in 1 ml Covaris tubes (Covaris, 520130) using Covaris S220 with the following settings ...
-
bioRxiv - Genomics 2024Quote: Approximately 4.4 μg of HMW DNA was processed with DNA shearing through 6 passes of centrifugation in a g-tube (Covaris Part No. 520079) at 2,000 x g for 2 min ...
-
bioRxiv - Genomics 2020Quote: ... Genomic DNA was resuspended in water and sheared into 3-5 kb fragments using the S220 Focused-ultrasonicator (Covaris Inc., MA, USA).
-
bioRxiv - Genomics 2023Quote: ... Sonicate the chromatin until sufficiently sheared (130µL, 5% duty cycle, 75W peak incident power, 200 cycles per burst, 7°C, for 5 minutes using Covaris Focus-Ultrasonicator M220). The immunoprecipitation step included ...
-
bioRxiv - Microbiology 2024Quote: ... DNA was diluted to 3 µg/130 µL in microTUBEs (Covaris #520045) and sheared in triplicate to 300 bp fragments using the following settings on a Covaris LE220 Focused-Ultrasonicator ...
-
bioRxiv - Developmental Biology 2019Quote: ... DNA (3 μg) was sheared with S2 Focused-ultrasonicator (Covaris, Wobum, MA, USA) and processed by SureSelectXT Human All Exon V5 (Agilent Technologies ...
-
bioRxiv - Microbiology 2022Quote: ... post-RCA DNA was debranched and fragmented to 6-8 kb-sized fragments using the above-mentioned protocol with the modification of the g-TUBE (Covaris) being centrifuged at 13200 rpm (16363 RCF ...
-
bioRxiv - Microbiology 2024Quote: ... DNA was fragmented into 2–8 kb pieces using focused ultrasonication (Covaris E220 with miniTUBE red). DNA Fragments were subsequently cloned into a PCR-linearized pZE21 expression vector (primers 1 and 2 ...
-
bioRxiv - Evolutionary Biology 2019Quote: ... DNA was sheared to 3-4kb using Adaptive Focused Acoustics technology (Covaris, Woburn, MA, USA) and cloned into the plasmid vector pIK96 as previously described (Ferris et al ...
-
bioRxiv - Microbiology 2021Quote: ... Genomic DNA was sheared to 3 kb using a Covaris LS220 (Covaris Inc., Woburn, MA, USA) or 15 kb (for stationary phase samples and bacteroids isolated from dnf mutant nodules and the matched wild-type A17 sample ...
-
bioRxiv - Molecular Biology 2023Quote: ... 3 times 30 seconds ON/OFF sonication was carried out at high intensity (Covaris S2 Focus Ultrasonicator) to disrupt the chromatin and release nuclear proteins ...
-
bioRxiv - Molecular Biology 2023Quote: ... (4) DNA was sheared to a size of 300-500bp using Covaris LE220 machine (Covaris) at the conditions ...
-
bioRxiv - Genomics 2019Quote: ... DNA was then resuspended in 10 mM T ris-HCl pH 8 and 5 ug aliquots were sonicated by Covaris S2 to fragment sizes in the range of 450-550 bp ...
-
bioRxiv - Microbiology 2022Quote: ... Genomic DNA samples (3 µg) were sheared to an average size of 12 kb via G-tube (Covaris) before library preparation ...
-
bioRxiv - Plant Biology 2020Quote: ... 3 μg of DNA was sheared to 350 bp average size using an S220 Focused-ultrasonicator (Covaris, Woburn, MA, USA). Barcoded ...
-
bioRxiv - Microbiology 2022Quote: ... Genomic DNA samples (3 μg) were sheared to an average size of 10 kb via G-tube (Covaris, Woburn, MA) before library preparation ...
-
bioRxiv - Evolutionary Biology 2021Quote: ... 2-3 µg of DNA was sheared to 400 bp or 800 bp using a Covaris LE220 pulse focused sonicator (Covaris) and size selected using a Pippin Prep (Sage Science) ...
-
bioRxiv - Microbiology 2019Quote: ... 2-5 µg of genomic DNA was sheared with a Covaris M220 Focused-ultrasonicator (Covaris) into 400-600bp fragments ...
-
bioRxiv - Genomics 2022Quote: ... Chromatin was recovered after a centrifuge step (13,400 rcf, 20 min, 4°C) and was subjected to sonication on a S220 focused-ultrasonicator (Covaris) (180s ON – 30s OFF – 180s ON ...
-
bioRxiv - Immunology 2021Quote: Ten million naïve or LPS-stimulated (0.1mg/mL for 4 hours) human peripheral blood-derived macrophages were cross-linked and processed using truChIP kit (Covaris Inc), as described in detail before(Mehta et al. ...
-
bioRxiv - Molecular Biology 2022Quote: ... of a 100mg/mL stock in DMSO was sonicated into 30uL PBS at 4°C using an S220 Focused-Ultrasonicator (Covaris) with sonication at peak power = 140 ...
-
bioRxiv - Genomics 2022Quote: ... the resulting 3C templates were purified using AMPure XP beads (Agencourt) and 4 µg of each template was sheared on a Covaris M220 focused-ultrasonicator (Covaris) to achieve 300 bp DNA fragments ...
-
bioRxiv - Cancer Biology 2021Quote: ... 200 cycles per burst for 30 min at 4° C to obtain 100-500 base pair chromatin fragments (Covaris, Woburn, CA). Nuclear sheared lysates were clarified by centrifugation at 15,000 x g for 10 min at 4° C ...
-
bioRxiv - Genetics 2022Quote: ... 8 kb was done using g-TUBE (Covaris) following manufacturer protocols ...
-
bioRxiv - Physiology 2021Quote: ... The resuspended chromatin was sonicated into fragments (200 to 500 bps long) at 4 C using an ultrasonic crusher (Covaris, Massachusetts, USA). The sheared chromatin was immunoprecipitated with anti-HA antibodies (Sigma-Aldrich ...
-
bioRxiv - Animal Behavior and Cognition 2023Quote: ... 5 µg of sperm DNA from 4 CT and 4 Cort F0 mice were fragmented by centrifugation for 60 s at 7200 rpm using g-TUBES (Covaris, Woburn, MA, USA) to obtain 8 kb-long fragments ...
-
bioRxiv - Microbiology 2020Quote: 800 ng of genomic DNA isolated from week 2 and week 5 samples was sonicated using an E220 focused ultrasonicator (Covaris) to produce 400 bp fragments which were purified using Agencourt AMPure XP beads (Beckman Coulter) ...
-
bioRxiv - Genomics 2020Quote: ... 8 μg of gDNA was sheared using g-Tubes (Covaris) and concentrated with the AMPure PB magnetic beads.
-
bioRxiv - Evolutionary Biology 2023Quote: ... 8°C) and Covaris microTUBE Snap-Cap tubes (Covaris 520045). Sequencing libraries were produced using the KAPA HyperPrep Kit (Roche 07137923001 ...
-
bioRxiv - Neuroscience 2020Quote: ... Aggregates were then diluted to a concentration of 100 µg/mL with 1x HBSS buffer followed by three 10s pulses of sonication using a 1/8” probe equipped QS5 Sonicator (Covaris, Woburn, MA). For cell culture experiments ...
-
bioRxiv - Genetics 2020Quote: ... using a Covaris S220 instrument with SonoLab software version 7 (Covaris, Inc., USA), to recover fragmented DNA between 150-200 bp ...
-
bioRxiv - Microbiology 2020Quote: ... then fragmented at 8 kbp with g-TUBEs (Covaris, Woburn, MA) to homogenized DNA fragments lengths increasing accuracy of input DNA molarity calculation to maximize yields ...
-
bioRxiv - Genomics 2020Quote: ... 8 kb and 20 kb fragmentation was done using g-TUBE (Covaris) following manufacturer protocols ...
-
bioRxiv - Developmental Biology 2019Quote: ... in 1× fixing buffer for 5 min at room temperature according to the vendor’s manual (Covaris). Crosslinked cells were then resuspended in 1× shearing buffer and sonicated with Covaris E220 for 780 sec using the following settings ...
-
bioRxiv - Genomics 2022Quote: ... 1-2 micrograms of high molecular weight DNA was sheared using g-tube (Covaris, Woburn, MA) to 5-9 Kbp at a 7000 RPM and size selected using the 0.75% DF 3-10kb Marker S1-Improved Recovery cassette definition on the Blue Pippin (Sage Science) ...
-
bioRxiv - Cell Biology 2023Quote: ... The microTUBE AFA Fiber Crimp-Cap 6×16mm (Covaris, SKU: 520052) was used with the sonicator ...
-
bioRxiv - Genetics 2019Quote: ... Cells were resuspended in 1 ml shearing buffer (10 mM Tris pH 8.0, 5 mM EDTA, 0.1% SDS) and sonicated (Covaris) with the following settings (Peak Incident Power = 100 W ...
-
bioRxiv - Genetics 2022Quote: ... genomic DNA was sheared to ~8 KB using g-tubes (Covaris, Woburn, MA, USA) and size-selected with the Blue Pippin system (Sage Science ...
-
bioRxiv - Microbiology 2023Quote: ... 8 µg genomic DNA was sheared using g-tubes from Covaris (Woburn, MA, USA) according to the manufactureŕs instructions ...
-
bioRxiv - Molecular Biology 2020Quote: ... The epidermis was homogenised in 8 M urea buffer with an ultrasonicator (S220X, Covaris, Brighton, UK) with 175 W peak power for 8 min ...
-
bioRxiv - Genomics 2020Quote: ... A total of 2 µg of DNA was sheared targeting 1 kbp fragments on a Covaris-S2 (Covaris Brighton, UK), size selected on a Sage Science Blue Pippin 1.5% cassette (Sage Science ...
-
bioRxiv - Genomics 2021Quote: ... protein–DNA crosslinks were made at RT for 5 min with 1% formaldehyde and tissue was pulverized using the CryoPrep (Covaris Inc., MA, USA). Cells were lysed and nuclei were prepared using Covaris lysis buffer ...
-
bioRxiv - Genomics 2021Quote: ... protein–DNA cross-links were made at RT for 5 min with 1% formaldehyde and tissue was pulverized using the CryoPrep (Covaris Inc., MA, USA). Cells were lysed and nuclei were prepared using Covaris lysis buffer ...
-
bioRxiv - Genomics 2022Quote: ... For the paired end library a total of 2 µg of DNA was sheared targeting 1 kbp fragments on a Covaris-S2 (Covaris Brighton, UK), size selected on a Sage Science Blue Pippin 1.5% cassette (Sage Science ...
-
bioRxiv - Immunology 2021Quote: ... in immunoprecipitation buffer (0.1% Triton X-100, 0.1 M Tris-HCl pH 8, 0.5 mM EDTA, and 0.15 M NaCl in 1Å~ Covaris D3 buffer) at 4°C ...
-
bioRxiv - Genomics 2020Quote: ... Samples were sheared on the Covaris® LE220plus using the 8 microTUBE strip V1 (PM# 520053; Covaris, Woburn, MA) with the base pair (bp ...