Labshake search
Citations for Nikon :
401 - 450 of 546 citations for Water Nuclease Free since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cell Biology 2023Quote: ... The excitation laser was collimated by a telescope to avoid power loss at the XY galvanometric mirror scanner and to fill the back aperture of a water-immersion objective (CFI Apo 40× WI, NA 1.25, Nikon). A half-wave plate (AHWP05M-980 ...
-
bioRxiv - Biophysics 2023Quote: ... Fluorescence emitted from donor (LD555) and acceptor (LD655) fluorophores was collected with a 1.27 NA 60× water-immersion objective (Nikon), spectrally resolved using a T635lpxr dichroic (Chroma) ...
-
bioRxiv - Neuroscience 2023Quote: ... Images were acquired using a Bergamo II two-photon microscope system with a resonant scanner (Thorlabs) and a 16 x / 0.8 NA water immersion objective lens (Nikon). YFP was excited at 925 nm with a mode-locked tunable ultrafast laser (InSightX3 ...
-
bioRxiv - Cell Biology 2023Quote: Quantification of nuclear height pre- and post-confinement was performed using a spinning disk confocal and a SR Plan Apo 60x 1.2 NA water objective (Nikon). To determine nuclear height ...
-
bioRxiv - Cell Biology 2023Quote: ... cell culture dishes were imaged by spinning disc confocal microscopy with a SR Plan Apo 60x 1.2 NA water objective (Nikon). For each organoid ...
-
bioRxiv - Bioengineering 2023Quote: ... The image is refracted through the coverslip and water into a third objective (O3, 25 × NA=1.1, Nikon MRD77220) mounted inside the water chamber ...
-
bioRxiv - Neuroscience 2023Quote: ... images were collected at a frame rate of 30 Hz with bidirectional scanning through a 16x/0.8 NA/3 mm WD water immersion objective (MRP07220, Nikon). GCaMP6f was excited at 920 nm with a femtosecond-pulsed two photon laser (Insight DS+Dual ...
-
bioRxiv - Neuroscience 2024Quote: ... Electrode placement and patching was visually guided by observing the preparation with oblique illumination of infrared light through a 40× water immersion objective (NIR Apo 40× /0.80W, Nikon) and 1 – 2× optical zoom ...
-
bioRxiv - Neuroscience 2024Quote: ... The laser was focused onto L2/3 of binocular V1 through a 16x water-immersion objective lens (0.8NA, Nikon). Ca2+ transients were obtained from neuronal populations at a resolution of 512 x 512 pixels (sampling rate ∼30 Hz) ...
-
bioRxiv - Neuroscience 2024Quote: ... All electrode placement and patching were visually guided by observing the preparation with oblique illumination of infrared light through a 40× water immersion objective (NIR Apo 40×/0.80W, Nikon) and 1–2x optical zoom ...
-
bioRxiv - Neuroscience 2024Quote: ... was used to rapidly toggle a 40X NIR water immersion objective lens (0.8 NA 3.5 mm WD, Nikon USA) between stratum pyramidale ...
-
bioRxiv - Cell Biology 2024Quote: ... which is conjugate to the pupil of the primary objective (O1 in Figure 2A: NA 1.10, Apo LWD 25X, Water-dipping, MRD77220, Nikon). The laser beam is scanned by two galvo mirrors (Galvo 1 and 2 ...
-
bioRxiv - Biochemistry 2024Quote: ... Fluorescence emission from donor and acceptor fluorophores was collected using a 60X/1.27 NA super-resolution water-immersion objective (Nikon). Fluorescence was recorded onto two aligned ORCA-Fusion sCMOS cameras (C-14440-20UP ...
-
bioRxiv - Biophysics 2021Quote: ... The beam is coupled in the optical path of the microscope by a dichroic mirror and focused in the object plane through a water immersion objective (Plan Apo VC WI, 60x, NA=1.2; Nikon Corporation). To measure the force ...
-
bioRxiv - Neuroscience 2020Quote: ... Cells were viewed using 63X water immersion objective of a fixed stage compound microscope (Nikon Ni-E or Olympus BX61WI). Patch pipettes were pulled from borosilicate glass (OD ...
-
bioRxiv - Biochemistry 2019Quote: ... polarization-split 1064 nm beams are steered by two 1D electro-optical deflectors (EODs, Conoptics, Inc.) into a 60x water immersion objective (Nikon). The laser light collected from the chamber of an oil immersion condenser is projected onto two quadrant photodiodes conjugate to the back focal plane of the condenser for direct force detection.53 The feedback loop and data acquisition used a National Instruments Field Programmable Gate Array controlled by custom LabVIEW virtual instruments.
-
bioRxiv - Neuroscience 2019Quote: ... whole-cell patch-clamp recordings were performed using an upright microscope (Movable Objective Microscope, Sutter) with a 40× water-immersion objective lens (CFI Apo 40XW NIR, Nikon). The external solution ...
-
bioRxiv - Biophysics 2020Quote: ... and their swimming behavior was studied at the water-glass interface on an epifluorescence microscope stage (Eclipse TE-300; Nikon). The cover slips were covered with poly-HEME to prevent the attachment of the cells to the glass ...
-
bioRxiv - Neuroscience 2021Quote: ... Neurons located ∼200 µm below the surface of the brain were visualised with a 16x 0.8 NA water-immersion objective (Nikon, Japan) and GaAsP PMTs (Hamamatsu Photonics ...
-
bioRxiv - Neuroscience 2021Quote: In vivo imaging was performed using a commercial two-photon microscope (B-scope, Thorlabs, Newton, NJ, USA) and a 16x water immersion objective (Nikon) with excitation at 925 nm (InSight X3 ...
-
bioRxiv - Neuroscience 2020Quote: ... Fluorescence was measured using an Eclipse E400 epifluorescence microscope with a FluorX40 water immersion objective (Nikon Corporation, Melville, NY, USA) equipped with a Sutter Lambda 10-2 optical filter changer ...
-
bioRxiv - Microbiology 2021Quote: ... with a peltier-cooled back-illuminated EMCCD camera (IXON3, 1024 × 1024 pixels, Andor, Ireland) and a 60× water-immersion objective (CFI APO, NA 1.2, Nikon USA). GFP excitation and bacterial bright-field imaging was achieved by a 150 W Mercury-lamp with filter sets (AHF ...
-
bioRxiv - Developmental Biology 2022Quote: ... The InVi-SPIM is equipped with a Nikon 25x/1.1NA water dipping objective (CFI75 Apochromat 25XC W, Nikon Instruments Inc.) used for detection ...
-
bioRxiv - Neuroscience 2021Quote: ... Images were acquired with a 40x water immersion objective (Nikon CFI APO NIR 40X W, 0.80 NA, 3.5 mm WD). Single planes (512×512 pixels ...
-
bioRxiv - Neuroscience 2021Quote: ... equipped with DIC optic and filters set to visualize tdTomato and EYFP using an IR 40x water-immersion objective (Nikon). Combination of electrophysiological properties and expression of fluorophore was used to identify CINs and D1 MSNs ...
-
bioRxiv - Neuroscience 2021Quote: ... we assessed brain motion in head-fixed animals using a commercial 2P microscope (Bruker Ultima Investigator) using a 16X water immersion objective (Nikon), and resonant galvo scanning at 30 fps ...
-
bioRxiv - Bioengineering 2021Quote: ... A super-continuum laser (SuperK EVO EU-4, NTK Photonics) and a 60× water-immersion objective (CFI Plan Apochromat VC, Nikon) were used in the FCS experiments ...
-
bioRxiv - Neuroscience 2022Quote: ... a pulsed tunable laser (MaiTai eHP DeepSee by Spectra Physics) providing excitation light at 940nm and 16X or 40X water-immersion objectives (Nikon). Images (256×256 pixels ...
-
bioRxiv - Cell Biology 2020Quote: Movies were taken using a Nikon E800 microscope with a 60x water immersion lens (NA 1.0 Nikon Fluor WD 2.0) and an LED light source driven by Micromanager 1.4.22 Freeware (Edelstein et al ...
-
bioRxiv - Neuroscience 2021Quote: ... whole-cell patch-clamp recordings and calcium imaging were performed using an upright microscope (Movable Objective Microscope, Sutter) with a 40× water-immersion objective lens (CFI Apo 40XW NIR, Nikon). The external solution ...
-
bioRxiv - Neuroscience 2020Quote: ... equipped with a camera and software (TrueChrome Metrics) using a 10x water immersion objective lens (Nikon Plan Fluor, NA 0.30), which allowed precise injection of the AAV2 into the DG ...
-
bioRxiv - Plant Biology 2021Quote: Hyperspectral Raman images were acquired using a confocal Raman imaging microscope (alpha 300 R, WITec, Ulm, Germany) with a water immersion objective (Nikon Corporation ...
-
bioRxiv - Neuroscience 2022Quote: ... Imaging was conducted ∼150 – 300 µm underneath the pial surface with a 16× water-immersion objective lens (Nikon, NA 0.8). Image data were acquired at 512 × 512 pixels ...
-
bioRxiv - Biophysics 2021Quote: ... The beam was coupled in the optical path of the microscope by a dichroic mirror and focused in the object plane through a water immersion objective (Plan Apo VC WI, 60x, NA = 1.2; Nikon Corporation). To measure the force ...
-
bioRxiv - Immunology 2020Quote: ... for each larva were acquired using a 20X (0.95 NA) water immersion lens and NIS-Elements software (both Nikon Corporation). 3D deconvolution was performed in NIS-Elements and deconvolved z-stack files were 3D rendered for sphericity quantification using Imaris version 9.5 (Bitplane ...
-
bioRxiv - Neuroscience 2021Quote: The stratum pyramidale of dorsal CA1 was imaged using a two-photon microscope (Scientifica) with a water-immersion objective (CFl75 LWD 16X W, Nikon; 0.80 numerical aperture ...
-
bioRxiv - Biochemistry 2022Quote: ... and an iXON 897 EMCCD camera (Andor, Belfast, Northern Ireland) using a 60x/1.2 Plan Apochromat water objective (Nikon, Japan). Proteins were heated to the indicated temperatures for 15 min in 20 mM PIPES/NaOH ...
-
bioRxiv - Bioengineering 2022Quote: ... a water dipping objective with high NA and long working distance is utilised (Nikon Fluor, 60x w NA1.00 WD 2.0). After the high OD short-pass filter (Semrock FF01-637/7) ...
-
bioRxiv - Neuroscience 2023Quote: ... The ank-G-GFP signal was imaged at 920 nm wavelength using a 25x water immersion objective (Nikon, NA = 1.1). Anesthetized imaging sessions lasted no longer than 1 h.
-
bioRxiv - Neuroscience 2022Quote: 2Pimaging was performed using a multiphoton laser scanning microscope (Ultima 2P Plus, Bruker Corporation, MA, USA) equipped with a 16× water immersion objective (NA = 0.8, Nikon, Japan). A widely tunable ultrafast laser (InSight X3 ...
-
bioRxiv - Neuroscience 2022Quote: ... All imaging was performed live using a Nikon A1R resonance scanning confocal microscope and a 40X Apochromat long-working distance water immersion objective with a 1.15 NA (Nikon MRD77410). A temperature-controlled stage maintained at 28.5°C was used for all time-lapse experiments ...
-
bioRxiv - Neuroscience 2022Quote: ... The light beam was rasterized by Galvo-Resonant scanners bidirectionally at a frame rate of ∼19 Hz and focused onto the tissue via a 16× water immersion objective (Nikon; NA = 0.8 ...
-
bioRxiv - Cell Biology 2023Quote: ... A single laser beam was split into 2 beams using polarizing beam splitters and steered into a 60x water immersion objective (Nikon). Laser light was projected through an oil immersion condenser and into quadrant photodiodes (JQ-50P ...
-
bioRxiv - Neuroscience 2023Quote: ... was built around a Nikon Ti-U microscope body equipped with Nikon 40× 1.15 NA water immersion objective (Nikon, MRD77410) or Olympus 60x NA=1.2 water immersion objective (UPLSAPO60XW 60X ...
-
bioRxiv - Microbiology 2023Quote: ... agarose pads prepared with tap water and phase-contrast images were acquired using an ECLIPSE Ti inverted research microscope (Nikon) equipped with a Plan Apo λ 100× Oil Ph3 DM (1.45 NA ...
-
bioRxiv - Neuroscience 2023Quote: ... a sCMOS digital camera (Hamamatsu ORCA-Flash 4.0 V2) and a 60 x water objective (Nikon, Japan, numerical aperture = 1.0). And the ratiometric quantitation (ΔR / R0 ...
-
bioRxiv - Neuroscience 2023Quote: ... The beam then passed through 8 kHz Galvo-Resonant Scanner (Cambridge Technology, 6215H galvo scanner and CRS 8K resonant scanner) and 16x/0.8NA water-immersion objective (Nikon, MRP07220) to form a 512×796 pixel field of view (∼1 mm2) ...
-
bioRxiv - Bioengineering 2023Quote: ... At the end of the optical path the beam was tightly focused by a water matched CFI plan 100XC W objective with a numerical aperture (NA) 1.1 (Nikon, Japan) directly onto the photosensitive resist ...
-
bioRxiv - Molecular Biology 2023Quote: ... Images were acquired with a 60X 1.27 NA water immersion objective (CFI SR Plan Apo IR 60XC WI, Nikon, Japan). The environmental chamber was maintained at 37° C ...
-
bioRxiv - Neuroscience 2024Quote: ... the beam goes through a 4f relay system, followed by a tube lens (TTL200MP2, Thorlabs) and a water-immersion objective lens (CFI75 LWD 16X, Nikon). The effective magnification between the DMD plane and the sample plane is 13.3× ...