Labshake search
Citations for Nikon :
201 - 250 of 508 citations for Recombinant Human Chemokine C X C Motif Ligand 10 since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Bioengineering 2021Quote: ... with either an oil-immersion TIRF 100 x or 40 x objective (N.A. 1.49, Nikon) coupled to either an InGaAs camera (NIRvana 640 ST ...
-
bioRxiv - Biophysics 2019Quote: All data collections were carried out at room temperature (∼23° C) using a total internal reflection fluorescence (TIRF) inverted microscope (Nikon Eclipse Ti microscope) equipped with a 100× (1.45 NA ...
-
bioRxiv - Biochemistry 2019Quote: Every data collection was carried out at room temperature (~23°C) using a total internal reflection fluorescence (TIRF) inverted microscope (Nikon Eclipse Ti microscope) equipped with a 100× (1.45 NA ...
-
bioRxiv - Cell Biology 2020Quote: ... Fluorescence signal was detected using an EMCCD Evolve mono FW DELTA 512×512 camera (Roper Scientific) with the intermediate lens 2.5X (Nikon C mount adapter 2.5X) or a CCD CoolSNAP MYO M-USB-14-AC camera (Roper Scientific ...
-
bioRxiv - Cell Biology 2020Quote: ... Fluorescence signal was detected using an EMCCD Evolve mono FW DELTA 512×512 camera (Roper Scientific) with the intermediate lens 2.5X (Nikon C mount adapter 2.5X) or a CCD CoolSNAP MYO M-USB-14-AC camera (Roper Scientific) ...
-
bioRxiv - Evolutionary Biology 2019Quote: ... based on expression of GFP assessed at age 7-10 days using a Nikon SMZ-18 stereomicroscope with a C-HGFI Intensilight fluorescence light source and GFP filter cube (Nikon GmbH, Düsseldorf, Germany).
-
bioRxiv - Microbiology 2021Quote: ... The culture was incubated further in incubator at 37°C with 5% CO2 and observed daily for cytopathic effects (CPEs) under an inverted microscope (Nikon, Eclipse Ti, Japan) [11] ...
-
bioRxiv - Evolutionary Biology 2019Quote: ... by sorting GFP expressing or non-GFP expressing offspring under a stereomicroscope equipped with epi-fluorescence (Nikon SMZ-18 stereomicroscope with a Nikon C-HGFI Intensilight fluorescence and GFP filter cube; Nikon GmbH, Düsseldorf, Germany) over a period of two weeks after ensuring the last offspring were observed ...
-
bioRxiv - Animal Behavior and Cognition 2021Quote: ... and then stored at 4°C until they were observed with an epifluorescence microscope (PRIMACEN, uprightt microscope Nikon 1, Nikon, Champigny/marne, France) as first evaluation ...
-
bioRxiv - Animal Behavior and Cognition 2021Quote: ... and then stored at 4°C until they were observed with an epifluorescence microscope (PRIMACEN, uprightt microscope Nikon 1, Nikon, Champigny/marne, France) as first evaluation ...
-
bioRxiv - Microbiology 2022Quote: ... The cultures were incubated further in five per cent CO2 incubator at 37°C and observed daily for CPEs under an inverted microscope (Nikon, Eclipse Ti, Japan). Cellular morphological changes were recorded using a camera (Nikon ...
-
bioRxiv - Microbiology 2021Quote: ... The cultures were incubated further in incubator at 37°C with 5% CO2 and observed daily for cytopathic effects (CPEs) under an inverted microscope (Nikon, Eclipse Ti, Japan). Cultures that showed CPE were centrifuged at 4815 × g for 10 min at 4°C ...
-
bioRxiv - Bioengineering 2022Quote: ... Each sample was analysed at 37°C for a maximum of 30 minutes in a Nikon Ti-e Inverted Microscope (Ti Eclipse, C-LHGFI HG Lamp, CFI Plan Fluor 40X NA 0.6 air objective; Nikon; Neo sCMOS camera; Andor) with NIS elements AR software ...
-
bioRxiv - Bioengineering 2022Quote: ... The bead trajectories were recorded in a Nikon Ti-E inverted microscope (Ti-Eclipse, C-LHGFI HG Lamp, CFI Plan Fluor 40× NA 0.6 air objective; Nikon; Neo sCMOS camera; Andor) with NIS elements AR software and analysed using a custom MATLAB script ...
-
bioRxiv - Neuroscience 2022Quote: ... Fluorescent images were then collected using a 20X air objective using an inverted Nikon Eclipse Ti2 microscope coupled to a mercury light source (Nikon Intensilight C-HGFIE), captured with Nikon Elements software (AR package) ...
-
bioRxiv - Pathology 2022Quote: ... Changes in the airway lumen area were recorded in a time-lapse setting with images captured every 5 s for 5 min following each dose of MCh using a 10x objective on a temperature-controlled Nikon inverted microscope at 37 °C with 5% CO2 (NIKON Ti2 widefield, Japan). Airway areas were analyzed using NIKON NIS-Elements analysis software ...
-
bioRxiv - Biophysics 2023Quote: ... The trapping beam is expanded by a lens pair (Thorlabs, 100 mm – #LA1509-C; 200 mm – #AC508-200-B) and directed into the microscope (Nikon, Eclipse Ti-U) backport with a broadband mirror (Thorlabs ...
-
bioRxiv - Neuroscience 2023Quote: ... An X-CITE LED illuminator (Nikon) was used for excitation ...
-
bioRxiv - Cell Biology 2022Quote: ... Live cell experiments were performed using a growth chamber (37°C, 5% CO2) in connection to a Nikon Eclipse Ti-E inverted microscope microscope (Nikon Instruments Inc. Tokyo, Japan), equipped with DU897 ANDOR EMCCD camera (Oxford Instruments ...
-
bioRxiv - Cell Biology 2020Quote: ... Live cell imaging was performed at 37 °C by using an incubator stage (OKOLab) mounted onto a confocal laser scanning microscope (Nikon Eclipse Ti-E, A1R).
-
bioRxiv - Biophysics 2022Quote: ... and imaged at different timepoints (day 0-2) at 25°C at 100 ms exposure with a 40X objective lens (Nikon Eclipse Ti2 (RAMCON, Denmark)) ...
-
Reduced Hippocampal Inhibition and Enhanced Autism-Epilepsy Comorbidity in Mice Lacking Neuropilin 2bioRxiv - Neuroscience 2021Quote: Slices were transferred to a submerged recording chamber and perfused with oxygenated aCSF at 33 ± 1°C and CA1 pyramidal cells were patched under IR-DIC visualization using Nikon Eclipse FN-1 (Nikon Corporation, Shinagawa, Tokyo, Japan) or Olympus BX50 (Olympus Corporation ...
-
bioRxiv - Neuroscience 2019Quote: All live cell imaging was conducted on microscopes equipped with a heated stage at 37°C and 5% CO2 on either a Nikon A1R microscope (Nikon Instruments Inc., Melville, NY), a Zeiss 780 LSM confocal microscope (Carl Zeiss ...
-
bioRxiv - Molecular Biology 2019Quote: ... 2D single-molecule acquisition were conducted at 37°C in Serum-Free medium on a Nikon TI-Eclipse widefield Microscope equipped with a 100X Oil-immersion objective (Nikon, Plan Apo N.A. = 1.45), perfect focusing systems and DU-897 (iXon ...
-
bioRxiv - Cell Biology 2023Quote: ... Plan Apo 60 x oil/NA 1.4 objective or Plan Fluor 100 x oil/NA 1.3 objective (all Nikon), 405/488/561/638 nm laser lines (Omicron ...
-
bioRxiv - Neuroscience 2023Quote: ... segments of basal dendrites were tracked down from the cell bodies of retrogradely labeled PT neurons in M1 and imaged under an oil-immersion 100x objective using the confocal microscope (NA = 1.45; x/y, 1024 X 1024 pixels; z step = 0.5 μm, A1R, Nikon). The distance from the soma to the basal dendrites analyzed was 50–100 μm ...
-
bioRxiv - Developmental Biology 2024Quote: ... Confocal sections encompassing their entire thickness were photographed using a Nikon Eclipse 90i microscope with a Plan Apo 40 x/1.3 or 100 x/1.4 objectives (Nikon) and a D-Eclipse c1 confocal system (Nikon ...
-
bioRxiv - Microbiology 2021Quote: ... Five microliters of the treated conidia was pipetted onto the concave slide at 25°C for 6 h and then observed by fluorescence microscopy (Nikon Eclipse Ti-s; Tokyo, Japan) for the analysis of germ tube emergence ...
-
bioRxiv - Neuroscience 2019Quote: Imaging was performed at room temperature (23 ± 1 °C) with a Nikon TIRF microscope system controlled with Micro-Manager (97) and equipped with a 100X oil objective (Nikon APO TIRF, 1.49 NA oil), as well as with Coherent Sapphire 488 nm (150 mW) ...
-
bioRxiv - Cell Biology 2021Quote: ... Laser ablation was performed at 37°C and 5% CO2 on a confocal spinning disk (Yokagawa CSU-X1 spinning head on a Nikon Eclipse Ti-E inverted microscope) equipped with an EMCCD camera (Evolve ...
-
bioRxiv - Biophysics 2021Quote: ... it was placed inside the incubator at 30°C and after 2-3 minutes imaged with a 100x oil-immersion objective (Nikon CFI SR Apo, NA = 1.49) for 20 minutes at 1 frame/5 s with 300 ms exposure times for both MT seeds (using 640 nm laser excitation ...
-
bioRxiv - Biophysics 2021Quote: ... the flow chamber was placed inside the microscope incubator at 30°C and imaged after 2-3 minutes with a 100X oil-immersion objective (Nikon CFI SR Apo, NA = 1.49) for 20 minutes at 1 frame/5 s with 300 ms exposure times for both MT seeds (using 640 nm laser excitation ...
-
bioRxiv - Cell Biology 2022Quote: The sample was imaged immediately at 23°C using a TIRF microscope (Nikon Eclipse Ti inverted microscope equipped with a Nikon 100x TIRF oil immersion objective). For each sample ...
-
bioRxiv - Molecular Biology 2023Quote: ... The sample was imaged immediately at 23°C using a TIRF microscope (Nikon Eclipse Ti inverted microscope equipped with a Nikon 100x TIRF oil immersion objective). For each sample ...
-
bioRxiv - Cell Biology 2023Quote: ... The slide was visualized at 30°C on a Nikon Ti2 Eclipse microscope equipped with an oil immersion objective (Nikon, CFI Apochromat TIRF 100x, NA1.49) and an Andor iXon Life 888 EMCCD camera.
-
bioRxiv - Cell Biology 2023Quote: ... time-lapse imaging was performed with a 15-min interval for 12 hours in a microscopic monitoring incubator BioStation CT (Nikon, 37 °C, 5% CO2, 100% humidity). The acquisition data was binarized using ImageJ.
-
bioRxiv - Molecular Biology 2023Quote: ... Live cells were imaged in a humidified chamber (OKO labs) maintained at 37 °C and 5% (v/v) CO2 using a 100× oil immersion objective NA 1.45 (Nikon MRD01905, pixel size 121 nm × 121 nm). For quantification of cells with aggregates ...
-
bioRxiv - Developmental Biology 2021Quote: ... Images were obtained with 40 X Plan APO lambda or 60 X APO TIRF (NA 1.49) lens on a NIKON A1 confocal microscope (NIKON, Japan) mounted with piezo device (Physik Instrumente GmbH ...
-
bioRxiv - Biophysics 2021Quote: ... Excitation was performed with inclined illumination through a TIRF 60 x objective (Nikon 60 X, oil immersion, NA 1.49 TIRF) to optimize the image contrast ...
-
bioRxiv - Neuroscience 2023Quote: ... Whole brain coronal image stacks were acquired at a resolution of 4.4 x 4.4 x 25.0 µm in XYZ (Nikon 16x NA 0.8), with a two-photon laser wavelength of 920 nm ...
-
bioRxiv - Cell Biology 2019Quote: ... using a 100 x objective (NA=1.3, Nikon). For microfluidics experiments ...
-
bioRxiv - Neuroscience 2022Quote: ... a 16 x immersion objective (NIKON, NA 0.8) connected to a GaSP PMT (H7422-40 ...
-
bioRxiv - Biochemistry 2024Quote: ... or a spinning disk confocal microscope (CSU-X, Nikon) equipped with 40x air or 60x oil objective ...
-
bioRxiv - Neuroscience 2023Quote: ... Spontaneous microglia calcium activity was captured as a 15 min T-series from a 300 x 300 µm area (512 x 512 pixels) at a 1Hz frame rate using a water immersion objective (Nikon, 16x; NA:0.8). A larger field of view (620 x 620 µm ...
-
bioRxiv - Biophysics 2023Quote: ... a CFI Apo 100 X (numerical aperture 1.49) objective (Nikon) and a total internal reflection fluorescence launcher with three laser lines ...
-
bioRxiv - Zoology 2024Quote: ... at 400 x magnification (Eclipse Ci-L, Nikon, Tokyo, Japan), with spores counted from all 16 squares of the gridded area ...
-
bioRxiv - Bioengineering 2024Quote: ... with a 100 x TIRF objective (NA = 1.49, oil, Nikon). Samples were illuminated using a 532-nm laser (Coherent ...
-
bioRxiv - Molecular Biology 2022Quote: ... using a confocal spinning disc microscope (Eclipse-Ti CSU-X, Nikon) with a 60x objective.
-
bioRxiv - Neuroscience 2022Quote: ... Micro-CT scans (X-Tek HMS ST 225, Nikon Metrology Ltd.) were taken at 130 kV ...
-
bioRxiv - Neuroscience 2022Quote: ... Signals were collected through a 16 x 0.8 NA objective (Nikon), isolated using a 594 nm high-pass dichroic and a bandpass filter (525/50 ...