Labshake search
Citations for Nikon :
951 - 1000 of 1072 citations for Fatty acids tall oil mixed with oleic acid sulfated potassium salts since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2021Quote: STED imaging was performed in an Abberior Instrument ‘Expert Line’ gated-STED coupled to a Nikon Ti microscope with an oil-immersion 60x 1.4NA Plan-Apo objective (Nikon, Lambda Series) and a pinhole size set at 0.8 Airy units ...
-
bioRxiv - Bioengineering 2020Quote: Images were obtained with a Nikon A1R confocal microscope (1024×1024 pixels) with a 10x air objective and 60x oil objective using Nikon NIS-Elements AR 3.1.0 (Nikon Instruments, Tokyo, Japan). To minimize potential bias ...
-
bioRxiv - Bioengineering 2020Quote: ... Images were obtained with a Nikon A1R confocal microscope (1024×1024 pixels) with a 10x air objective and 60x oil objective using Nikon NIS-Elements AR 3.1.0 (Nikon Instruments, Tokyo, Japan).
-
bioRxiv - Microbiology 2020Quote: ... Infected macrophages were examined using a Nikon Eclipse 50i microscope equipped with a ×100 1.25NA oil objective (Nikon Instruments, Melville, NY), and the number of parasites/100 macrophages were determined by counting 300 cells in each of the triplicate experiments per round of infection ...
-
bioRxiv - Cell Biology 2022Quote: ... The system was mounted on a Nikon Ti-E inverted microscope equipped with a Nikon CFI Plan Apo VC ×100/1.4 numerical aperture oil objective (Nikon, Tokyo, Japan). During imaging ...
-
bioRxiv - Developmental Biology 2022Quote: ... SS and S9 were acquired on a Nikon Ni-E microscope with either a Plan Apo λ 60x (numerical aperture 1.4) objective or a Plan Fluor 40x Oil (numerical aperture 1.3) objective using NIS elements (Nikon Inc., Melville, NY). All the remaining microscope images were acquired on a Nikon Ti2 inverted confocal microscope with a Plan ApoIR 60x objective (numerical aperture 1.27) ...
-
bioRxiv - Molecular Biology 2022Quote: Live cell imaging was done using a widefield microscopy system featuring a Nikon Ti-E body equipped with the Perfect Focus System and a 60× oil immersion objective with a numerical aperture of 1.4 (Nikon, Plan APO). We used an Andor Neo sCMOS camera ...
-
Kinetochore- and chromosome-driven transition of microtubules into bundles promotes spindle assemblybioRxiv - Cell Biology 2022Quote: ... The system was mounted on a Nikon Ti-E inverted microscope equipped with a Nikon CFI Plan Apo VC 100x/1.4 numerical aperture oil objective (Nikon, Tokyo, Japan). The system was controlled with the Prairie View Imaging Software (Bruker) ...
-
bioRxiv - Cell Biology 2022Quote: ... with DU4 detector using Nikon CFI Plan Apo Lambda 60X/1.4 NA oil immersion objective lens (MRD01605, Nikon, Melville, NY, USA). Immersion oil Type 37 (16237 ...
-
bioRxiv - Cell Biology 2020Quote: ... the system was mounted on a Nikon Ti-E inverted microscope equipped with a Nikon CFI Plan Apo VC 100x/1.4 numerical aperture oil objective (Nikon, Tokyo, Japan). During imaging ...
-
bioRxiv - Cell Biology 2020Quote: ... Confocal fluorescence microscopy was performed using a 100x oil immersion objective (NA 1.45) on a VT-iSIM microscope (Visitech; Nikon Eclipse TI), using 405 nm ...
-
bioRxiv - Microbiology 2021Quote: Live fluorescence images were obtained on an A1R laser scanning microscope (LSCM) using an A1+’s galvano scanner and oil immersion objective (Nikon, Japan). Spinach2 was imaged using a FITC 488 nm laser for EGPF (470/40 excitation and 515/30 emission) ...
-
bioRxiv - Neuroscience 2020Quote: ... En face Oil red O staining was performed and % lesion coverage determined by image analysis using NIS-elements software (Nikon, UK)3.
-
bioRxiv - Synthetic Biology 2020Quote: ... were collected using a 100X/1.40NA oil immersion objective on a Spectral Applied Research Aurora Borealis-modified Yokagawa CSU-X1 spinning disk confocal microscope (Nikon Ti), equipped with a 5% CO2 temperature-controlled chamber (OkoLab) ...
-
bioRxiv - Genetics 2020Quote: Live cell imaging was done using a wide field microscopy system featuring a Nikon Ti-E body equipped with the Perfect Focus System and a 60x oil immersion objective with a numerical aperture of 1.4 (Nikon, Plan APO). We used an Andor Neo sCMOS camera ...
-
bioRxiv - Microbiology 2021Quote: ... and a minimum of 5 different locations per coverslip were imaged with a 100x oil immersion objective (NA 1.45) on a VT-iSIM microscope (Visitech; Nikon Eclipse TI). Nuclei were counted manually using ImageJ (minimum 450 nuclei per sample and biological repeat).
-
bioRxiv - Cell Biology 2022Quote: ... mounted on a Nikon Ti-E inverted microscope with a Nikon CFI Plan Apo VC 100x/1.4 numerical aperture oil objective (Nikon, Tokyo, Japan). During live-cell imaging ...
-
bioRxiv - Cell Biology 2022Quote: ... Laser-scanning confocal imaging was performed using Nikon A1r based on a Ti-E inverted microscope with SR Apo TIRF 100× NA1.49 oil lens run by NIS Elements C software (Nikon, Tokyo, Japan). Laser scanning confocal imaging (Figure 4 E-G ...
-
bioRxiv - Cell Biology 2022Quote: ... cells were imaged using a spinning-disk confocal microscope with a 60×objective (Nikon T2 Microscope; Apo 60x oil; 1.4 NA) using the SoRa mode ...
-
bioRxiv - Cell Biology 2022Quote: ... Cells were imaged the following morning using a Nikon Ti2-E Inverted Microscope equipped with a TIRF illuminator and a Perfect Focus System (PFS) using a 100x Plan Apo Lambda oil objective (NA 1.4) (Nikon, Tokyo, Japan). Cells were preincubated for 30 min in KRBH containing 2.5 mM glucose at 37°C and 5% CO2 ...
-
bioRxiv - Microbiology 2022Quote: ... and examined with a Nikon Eclipse 90i microscope with a 100×/NA 1.4 phase-contrast oil immersion objective (Nikon, Melville, NY). Images were collected with an ORCA ER CCD camera (Hamamatsu ...
-
bioRxiv - Cell Biology 2022Quote: ... in a scanning confocal microscope with Fast AiryScan (Zeiss LSM880) or a 60x oil immersion objective (NA = 1.40) in an inverted microscope (Nikon Eclipse Ti). Maximal projections of the stacks were obtained with Fiji before quantification of nuclear and cytosolic intensity levels or ...
-
bioRxiv - Cell Biology 2024Quote: ... Immunofluorescent and live-cell transcriptional reporter images were collected on a 40X oil immersion objective (Nikon, CFI PLAN FLUOR NA 1.30). Photoconversion images were collected on a 60X oil immersion objective (Nikon ...
-
bioRxiv - Biophysics 2024Quote: ... Fixed cells were imaged at room temperature (22°C) in trace CO2 (open air) conditions using type N immersion oil (Nikon, #MXA22203).
-
bioRxiv - Cell Biology 2023Quote: On the iLAS2 – Visitron setup the time-lapses were imaged with a 100x TIRF objective (Nikon, ApoTIRF 100X oil (NA 1.49). Emission light was collected through a quad-band filter (Chroma ...
-
bioRxiv - Cancer Biology 2023Quote: ... at three regions of interest were imaged per sample using a 60x Plan Apo VC oil immersion objective with 1.4 NA on a Nikon A1 plus-RSi laser scanning confocal microscope (Nikon Elements software). Image resolution was 1024×1024 of z-slices covering the entirety of cell thickness ...
-
bioRxiv - Cell Biology 2023Quote: ... Live imaging was done using a CFI Plan Apochromat Lambda 60X/NA 1.4 oil objective mounted on a microscope (Nikon Eclipse Ti) equiped with a Prime 95B 22mm camera (Photometrics) ...
-
bioRxiv - Microbiology 2023Quote: Images were acquired using a Nikon A1R confocal microscope (equipped with 405 nm/Argon/561 nm lasers) using a Plan APO VC 60X/1.40 NA oil immersion objective with the Nikon Elements software (Nikon Instruments Inc.) or the Zeiss LSM 800 confocal microscope (equipped with 405 nm/488nm/561/640 nm lasers ...
-
bioRxiv - Microbiology 2023Quote: ... Representative images shown were captured using a confocal microscope at 60X magnification under oil immersion as described above (scale bar is 20 μm) (Nikon A1R). Tile scan images (6×6 mm ...
-
bioRxiv - Microbiology 2023Quote: ... Representative images shown were captured using a confocal microscope at 60X magnification under oil immersion (scale bar is 20 μm) (Nikon A1R). The size of the aggregates was calculated from images of live aggregated Spn captured using a Leica LMD6 with DFC3000G-1.3-megapixel monochrome camera at 40X magnification (Leica Biosystems ...
-
bioRxiv - Cell Biology 2024Quote: ... Live imaging was done using a CFI Plan Apochromat Lambda 60X/NA 1.4 oil objective mounted on a microscope (Nikon Eclipse Ti) equiped with a Prime 95B 22mm camera (Photometrics) ...
-
bioRxiv - Molecular Biology 2024Quote: Fixed iPSCs-derived MNs were imaged on a Nikon Instrument A1 Confocal Laser Microscope equipped with a 1.49 NA 100x objective (Plan Apo VC 100x Oil DIC N2, Nikon, Tokyo, Japan). Confocal images were collected with NIS-Elements AR software (Nikon) ...
-
bioRxiv - Molecular Biology 2024Quote: ... Cell imaging was performed using a Nikon A1R+ laser scanning confocal microscope equipped with a 60x NA1.4 oil immersion objective (Nikon, Vienna, Austria). To visualise Trypan blue and eYFP fluorescence ...
-
bioRxiv - Cell Biology 2024Quote: ... and images were captured using a fluorescence microscope (BZ-810; Keyence) equipped with a 60× oil-immersion objective lens (Nikon, NA1.40).
-
bioRxiv - Cell Biology 2024Quote: ... mounted on a Nikon Ti-E inverted microscope with a Nikon CFI Plan Apo VC 100 x/1.4 numerical aperture oil objective (Nikon, Tokyo, Japan). To excite DAPI ...
-
bioRxiv - Cell Biology 2024Quote: ... The system was mounted on a Nikon Ti-E inverted microscope equipped with a Nikon CFI Plan Apo VC 100x/1.4 numerical aperture oil objective (Nikon, Tokyo, Japan). The system was controlled with Prairie View Imaging Software (Bruker) ...
-
bioRxiv - Cell Biology 2024Quote: ... monastrol and AZ3146 was performed on a Dragonfly spinning disk confocal microscope system (Andor Technology, Belfast, UK) using the 100x/1.47 HC PL APO oil objective (Nikon, Tokyo, Japan) and Sona 4.2B-6 Back-illuminated sCMOS camera (acquisition mode set to high speed ...
-
bioRxiv - Cell Biology 2024Quote: ... Z stacks were acquired using a 60x oil immersion Plan Apochromat TIRF lens through NIS Elements software (Nikon Instruments, version 5.21.03). Post-acquisition max intensity Z projection and image presentation were performed using FIJI/ImageJ (version 1.53t) ...
-
bioRxiv - Neuroscience 2024Quote: ... the slices were viewed with laser lines at 488 nm and 568 nm using a 40x oil-immersion objective on a confocal laser-scanning microscope (Nikon A1).
-
bioRxiv - Neuroscience 2024Quote: ... Z-series images were taken with an inter-stack interval of 0.3 or 0.5 μm using a 60X oil immersion objective (Nikon APO 60x 1.4).
-
bioRxiv - Biophysics 2024Quote: Colocalization images were collected on a Nikon TE-2000 inverted RING-TIRF microscope with a 100× oil immersion objective (Nikon Instruments) with an Andor iXon X3 DU-897 EMCCD camera ...
-
bioRxiv - Cell Biology 2024Quote: All images were collected on a Nikon TE-2000 inverted RING-TIRF microscope with a 100x oil immersion objective (Nikon Instruments) with an Andor iXon X3 DU-897 EMCCD camera ...
-
bioRxiv - Neuroscience 2023Quote: ... Cells were then washed three times with RH and placed in the bottom of a plexiglass recording chamber attached to the stage of a custom-made spinning disc confocal microscope (Solamere Technology Group, Salt Lake city, USA) coupled to an upright microscope (Nikon Eclipse 80i; Nikon Corp., Tokyo, Japan) and continuously perfused (1 ml/min ...
-
bioRxiv - Biophysics 2021Quote: ... on a Nikon Eclipse Ti-E inverted microscope with a CFI Apo TIRF 100x (NA: 1.49) oil immersion objective and perfect focus system (PFS) (Nikon Instruments, Amsterdam, Netherlands), a Lumencor Spectra X LED light source (Lumencor Inc. ...
-
bioRxiv - Cell Biology 2022Quote: ... mounted on a Nikon Ti-E inverted microscope with Perfect Focus and a CFI Apo 60X/1.49 NA oil-immersion TIRF objective (Nikon Instruments, Melville, NY), equipped with an Evolve EMCCD camera (Photometrics ...
-
bioRxiv - Neuroscience 2021Quote: ... the cover glass was transferred to live-cell culturing metal holder with phenol red free NbActiv4 medium and mounted onto Nikon Eclipse TiE Motorized Inverted microscope equipped with a 100X oil-immersion objective (Nikon, N.A. = 1.49), an automatic TIRF/HILO illuminator ...
-
bioRxiv - Biochemistry 2020Quote: ... Confocal images were acquired on a Nikon C2+ confocal microscope equipped with a C2-DUVB GaAsP Detector Unit and using an oil-immersion 60 × 1.4 Nikon APO objective (Nikon Instruments, Amsterdam, Netherlands). Data were processed with the Fiji software.78
-
bioRxiv - Cell Biology 2021Quote: Images were acquired through Nikon A1R Confocal microscope with a ×60 NA plan-Apochromat oil differential interference contrast objective and NIS-Elements software (Nikon, Mississauga, Canada). Acquisition of high-resolution images was done by selecting Nyquist XY scan area ...
-
Long-Range Electrostatic Interactions Significantly Modulate the Affinity of Dynein for MicrotubulesbioRxiv - Biophysics 2021Quote: ... focused on the sample plane by an oil immersion objective (CFI60 Plan Apochromat Lambda 60x N.A. 1.4, Nikon Instruments, Inc., Melville, NY), as previously described (49) ...
-
Oligomerization state of the functional bacterial twin arginine translocation (Tat) receptor complexbioRxiv - Biophysics 2021Quote: Single particle photobleaching analyses were performed with a Nikon Eclipse Ti using a 100X oil-immersion objective (Nikon Apo TIRF, 1.49 NA) and narrowfield epifluorescence excitation48 with 488 and 640 nm diode lasers (Coherent) ...