Labshake search
Citations for JEOL :
151 - 200 of 1400 citations since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cell Biology 2024Quote: Transmission electron microscope (such as JEOL 1400, Tokyo, Japan)
-
bioRxiv - Microbiology 2024Quote: ... The VLPs were visualized with a JEM 2100 Transmission Electron Microscope (JEOL, Tokyo, Japan) operated at 200 kV ...
-
bioRxiv - Microbiology 2024Quote: ... A field emission scanning electron microscope (JEOL JSM-7500F) with the in-lens detector (SEI-detector ...
-
bioRxiv - Microbiology 2024Quote: ... followed by staining with uranyl acetate and lead acetate prior to observation on a JEOL JEM-1200EX transmission electron microscope (JEOL, Tokyo). In SEM analysis ...
-
Malaria parasites undergo a rapid and extensive metamorphosis after invasion of the host erythrocytebioRxiv - Microbiology 2024Quote: ... ultrathin sections microscope (JEOL) using a OneView 16-megapixel camera (Gatan-Ametek) ...
-
bioRxiv - Neuroscience 2024Quote: ... The cells were imaged with a TEM (JEM1400-LaB6, JEOL) operated at 80kV ...
-
bioRxiv - Microbiology 2024Quote: ... followed by staining with 2% uranyl acetate and image acquisition using JEM-1400 Flash TEM equipped with tungsten filament and sCMOS camera (JEOL Ltd, Japan). RNA encapsulation into LNP was measured by fluorescent-based RNA quantification system using Ribogreen ...
-
bioRxiv - Microbiology 2024Quote: ... Grids were observed using a JEM-1400 transmission electron microscope (JEOL) operated at 120 kV ...
-
bioRxiv - Microbiology 2024Quote: ... these grids were analyzed by TEM (JEOL, JEM 2010) with an accelerating voltage of 200 kV.
-
bioRxiv - Microbiology 2024Quote: ... the samples were examined using a JEM-2100 transmission electron microscope (JEOL, Tokyo, Japan) at an 80 kV voltage ...
-
bioRxiv - Microbiology 2024Quote: ... and then examined with a JEM-1400 (120 kV) transmission electron microscope (JEOL, Tokyo, Japan). Images were taken with a Morada digital camera (Olympus SIS ...
-
bioRxiv - Plant Biology 2024Quote: ... The sections were observed using a JEM-1400Plus (JEOL). All experiments were conducted at room temperature unless otherwise stated.
-
bioRxiv - Microbiology 2024Quote: ... The grids were inserted into a CRYO ARM 300 transmission electron microscopy (JEOL Ltd. Japan) equipped with a cold field-emission electron gun operated at 300 kV and an Ω-type energy filter with a 20− eV slit width ...
-
bioRxiv - Microbiology 2024Quote: ... The sections were post-stained with uranyl acetate and lead citrate and viewed using a JEOL JEM 1200 EX TEMSCAN transmission electron microscope (JEOL, Peabody, MA, USA) operating at an accelerating voltage of 80 kV.
-
bioRxiv - Molecular Biology 2024Quote: ... observed with a transmission electron microscope operated at 120 kV (JEOL, Japan), and images were recorded with a Xarosa digital camera (EM-SIS ...
-
bioRxiv - Microbiology 2024Quote: ... Thin sections were stained with uranyl acetate and lead citrate prior to examination in a JEOL 1200EX electron microscope (JEOL Ltd, UK).
-
bioRxiv - Microbiology 2024Quote: ... the samples were imaged using Transmission Electron Microscopy (JEM-100 CX II; JEOL).
-
bioRxiv - Microbiology 2024Quote: The four seed of lytic phages selected for generating the PTMPs were negatively stained with 1 % aqueous uranyl acetate before being analyzed by (TEM) electron microscopy (JEOL JEM-1011).
-
bioRxiv - Microbiology 2024Quote: ... Transmission electron microscopy was carried out on the 120-kV JEOL JEM-1400Flash Electron Microscope (JEOL Ltd., Welwyn Garden City, UK) with a JEOL Matataki Flash camera.
-
bioRxiv - Cell Biology 2024Quote: ... Grids were examined with a TEM (Jeol JEM-1400, JEOL Ltd, Tokyo, Japan) at 80 kV ...
-
bioRxiv - Cancer Biology 2024Quote: ... samples were cut at 200 nm for screening by light microscopy and then at 65 nm to be mounted on grids for TEM under a JEOL JSM 1400 (JEOL, USA) electron microscope ...
-
bioRxiv - Cell Biology 2024Quote: ... Sections were then contrasted with 3% uranyl acetate for 30 min and 2% lead citrate for 20 min in the LEICA EM AC20 and subsequently analysed with a TEM at 200kV (JEM2100Plus, JEOL, Japan) equipped with a 20-megapixel EMSIS Xarosa CMOS camera (EMSIS ...
-
bioRxiv - Cell Biology 2024Quote: ... Regions of interest from the LM were relocated within the TEM and tilt series from +-65° with 1° increments were acquired using TEMography software (TEMography.com, JEOL, Japan). The tomograms were then reconstructed using the back projection algorithm in IMOD (Kremer ...
-
bioRxiv - Microbiology 2024Quote: ... and visualized under a transmission electron microscope (JEM-100 CX II; JEOL).
-
bioRxiv - Immunology 2024Quote: ... and morphological characterization was performed using a JEM-2100 transmission electron microscope (TEM, JEOL, Tokyo, Japan). The particle size and zeta potential of AuNPs and nanoprobes were measured using a Zetasizer Lab ZS90 nanoparticle sizer analyzer (Malvern ...
-
bioRxiv - Biochemistry 2024Quote: ... Samples were viewed on a JEOL 1200EX transmission electron microscope (JEOL USA, Peabody, MA) with an AMT 8-megapixel digital camera (Advanced Microscopy Techniques ...
-
bioRxiv - Molecular Biology 2024Quote: ... EM images were recorded on a DE-20 camera (Direct electron LP) at a nominal magnification of 40,000 using a JEM2200FS electron microscope (JEOL Ltd.) operated at 200□kV accelerating voltage ...
-
bioRxiv - Microbiology 2024Quote: ... Samples were then viewed on a JEM-1400 TEM (JEOL, Japan) with an accelerating voltage of 120 kV ...
-
Structure, dynamics and evolution of the Candida albicans multi-drug resistance ABC transporter CDR1bioRxiv - Microbiology 2024Quote: A CRYO ARM 200 (JEOL) electron microscope equipped with an in-column Omega energy filter and DE64 detector was used for all cryo-EM data acquisition ...
-
bioRxiv - Microbiology 2024Quote: ... Ultra-thin sections were stained and examined at 80 kV under a transmission electron microscope (JEM-1230; JEOL, Japan).
-
bioRxiv - Microbiology 2024Quote: ... equipped with a Matataki Flash sCMOS camera (JEOL, Akishima, Tokyo, Japan).
-
bioRxiv - Microbiology 2024Quote: ... and imaged with a kV JEOL JEM 1010 transmission electron microscope (JEOL USA Inc.).
-
bioRxiv - Microbiology 2024Quote: ... The size of Cip encapsulated Cur-EPS was further analysed using Transmission Electron Microscopy (TEM, JEOL 1011, Japan). The Cip-Cur-EPS were prepared by depositing a micellar solution (0.1 mg/mL ...
-
bioRxiv - Microbiology 2024Quote: ... Samples were viewed using a JEOL 1400-plus TEM (JEOL, Peabody, MA). Transmission electron microscopy images were taken using a Gatan OneView 4 k×4 k camera (Gatan ...
-
bioRxiv - Microbiology 2024Quote: ... The images were acquired using a JEM1010 EM (JEOL, Tokyo, Japan) equipped with a FastScan-F214(T ...
-
bioRxiv - Microbiology 2024Quote: ... Samples were imaged on a JSM 6610 LV scanning electron microscope at 15kV and 12mm working distance (JEOL, Tokyo, Japan).
-
bioRxiv - Microbiology 2024Quote: ... some of the grids were inspected using the in-house JEM-2200FS/CR (JEOL, Ltd.) cryo-TEM equipped with a K2 bioquantum camera ...
-
bioRxiv - Microbiology 2024Quote: ... Fixed and stained cells were viewed under a transmission electron microscope at 120 KV (JEOL, JEM-2100 plus electron microscope) (Roy et al. ...
-
bioRxiv - Microbiology 2024Quote: ... Images were acquired using a transmission electron microscope (JEOL, JEM-1400plus).
-
bioRxiv - Microbiology 2024Quote: ... After drying the grids are then viewed on a JEOL 1400 FLASH 120kv TEM (JEOL USA Inc, Peabody, MA). Digital images are taken with an AMT NanoSprint43 Mark II camera (AMT Imaging ...
-
bioRxiv - Immunology 2024Quote: ... The grids were imaged at 1,200x magnification using a 1400+ TEM (JEOL, Akishima, Japan). TIFF file images were acquired using the interfaced BioSprint ActiveVu mid-mount CCD camera (Advanced Microscopy Technologies ...
-
bioRxiv - Microbiology 2024Quote: ... 10000x and 15000x using a 120 kV 1400FLASH TEM (JEOL), and images were acquired with a JEOL Matataki Flash sCMOS camera ...
-
bioRxiv - Immunology 2024Quote: ... Grids were stained with 1% (w/v) uranyl acetate solution on the JEM-1400Flash electron microscope (JEOL) at 100 kV.
-
bioRxiv - Microbiology 2024Quote: ... These sections were mounted on copper grids stained and were observed using a JEM-1400 Electron Microscope (JEOL Ltd, Tokyo, Japan) at an accelerating voltage of 120 kV and equipped with an Orious® SC1000 camera (Gatan-Ametek ...
-
bioRxiv - Microbiology 2024Quote: ... The prepared mesh was observed using a JEM-1400 (JEOL Ltd.) operated at 120 kV accelerating voltage and recorded using the built-in CCD camera.
-
bioRxiv - Microbiology 2024Quote: ... and glow-discharged for 10 s using a JEC-3000FC Auto Fine Coater (JEOL). The grid was blotted for 3 s at 8°C (100% humidity ...
-
bioRxiv - Microbiology 2024Quote: ... Screening and data collections were conducted using a CRYO ARMTM 200 or 300 electron microscope (JEOL) operating at 200 or 300 kV ...
-
bioRxiv - Microbiology 2024Quote: ... we used the customisable automated data acquisition system JADAS (JEOL), whereas cryo-EM movies for data collection were acquired using the automated EM data acquisition program Serial EM (Mastronarde ...
-
bioRxiv - Plant Biology 2024Quote: ... Images were acquired on a JEOL JEM F-200 (JEOL).
-
bioRxiv - Immunology 2024Quote: ... Images were captured using a JEOL 1400 Plus (JEOL) transmission electron microscope equipped with a LaB6 cathode.