Labshake search
Citations for Olympus :
101 - 150 of 153 citations for Biotin Z Antibody Internalization Kit rat since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Bioengineering 2023Quote: Maximum intensity projections were obtained from z-stacks taken at 20x (oil lens) magnification on a Fluoview FV1000 confocal laser scanning microscope (Olympus) with a step size of 5 μm between each slice ...
-
bioRxiv - Neuroscience 2023Quote: ... Z-stacks encompassing the entire dendritic arbor and relevant nuclear layer were collected using confocal microscopy (Olympus FV300 or FV3000). Dendrite territories were drawn in ImageJ by lines connecting arbor tips to generate a series of polygonal regions of interest (ROIs ...
-
bioRxiv - Microbiology 2023Quote: ... The focal position of the sample was kept at the focal position by a Z-drift compensation module (ZDC, Olympus). A blue laser beam (OBIS488-20 ...
-
bioRxiv - Cell Biology 2024Quote: ... Z-stack images were collected at 1-µm intervals (number of optical z-stacks: 90) to visualize the entire eggs using a fluorescence microscope (IX70; OLYMPUS) equipped with 60x/1.30 NA Sil or 20x/0.85 NA oil objective lens (OLIMPUS ...
-
bioRxiv - Neuroscience 2021Quote: ... VT) from confocal z-stack images collected on an Olympus FV1000 microscope equipped with Fluoview software (version 4.0, Olympus, Shinjuku, Japan). Unilateral traces of CA1 were created at 20X magnification on each section ...
-
bioRxiv - Neuroscience 2019Quote: ... GCaMP activity from a single z-plane (where the cH and LH neurons could be seen) was imaged using a confocal microscope (Olympus FV1000) at 1 fps ...
-
bioRxiv - Neuroscience 2020Quote: ... Z-stack images of dorsal striatal sections were taken on a confocal microscope (Zeiss LSM 780 AxioExaminer or Olympus FLUOVIEW FV3000) with a 20x objective using the same acquisition settings for each section ...
-
bioRxiv - Neuroscience 2020Quote: ... Z stack images were collected using a 20X and 40X oil objective on a laser scanning confocal system (Olympus Fluoview FV1000) and processed using ImageJ/FIJI software (National Institutes of Health) ...
-
bioRxiv - Bioengineering 2021Quote: ... Chondrocytes on the lateral femoral condyles were z-stack imaged by a confocal microscope (FV3000, Olympus, UPlanSApo 10X/0.40 NA dry) before and after the impact ...
-
bioRxiv - Neuroscience 2023Quote: The confocal imaging stacks were collected with a Z-step size of 0.25 μm under a confocal microscope (Olympus, Tokyo, Japan). Three-dimensional reconstructions were processed offline using Imaris 7.4.2 (Bitplane ...
-
bioRxiv - Neuroscience 2022Quote: ... Filled neurons green (dnKv4.2-negative) and green/red (dnKv4.2-positive) were imaged at multiple Z-planes using a two-photon microscope (Olympus FV1000-MPE) with a multiimmersion objective lens (ULTRA 25x ...
-
bioRxiv - Biophysics 2023Quote: ... Both live and fixed cells were then imaged at 37°C using an Olympus IX83 TIRF microscope equipped with a Z-Drift Compensator and a UAPO 100x/1.49 NA oil-immersion TIRF objective (Olympus, Tokyo, Japan). The microscope was equipped with an iXon 888 1k × 1k EMCCD Camera (Andor ...
-
bioRxiv - Biophysics 2023Quote: ... The sample was kept in focus over extended periods with the help of a z-drift compensation system (IX3-zdc2-83, Olympus, Japan). The emitted light was collected with the same objective and separated from the excitation light with the same dichroic beam splitter ...
-
bioRxiv - Bioengineering 2024Quote: ... microscope with a 60× oil-immersion objective (APON 60XOTIRF, 1.45 NA) equipped with both a cellTIRFTM illuminator and a z-drift control module (Olympus IX2-ZDC2). An EMCCD (electron-multiplying charge-coupled device ...
-
bioRxiv - Developmental Biology 2021Quote: ... Complete embryo confocal z-series images were acquired using a FV10i Confocal Laser Scanning Microscope and FV10i-SW image acquisition software (Olympus, Tokyo, Japan). Images were analysed using FV10-ASW 4.2 Viewer (Olympus ...
-
bioRxiv - Cell Biology 2022Quote: ... cells were imaged at 37°C using an Olympus IX83 TIRF microscope equipped with a Z-Drift Compensator and a UAPO 100X/1.49 NA oil-immersion TIRF objective (Olympus, Center Valley, PA). The microscope was equipped with an iXon 888 1k × 1k EMCCD Camera (Andor - Oxford Instruments ...
-
Cortical cerebrovascular and metabolic perturbations in the 5xFAD mouse model of Alzheimer’s diseasebioRxiv - Neuroscience 2023Quote: ... was also imaged for each sample using a confocal microscope (10X magnification, Z-stack 30 images, step size 1.51 μm, Olympus FV3000, Olympus Scientific).
-
bioRxiv - Biophysics 2023Quote: Three-dimensional z-stacks of bright-field and fluorescent images were taken using an Olympus IX81 confocal microscope (Olympus Corp. Tokyo, Japan) with a cooled CCD camera (Hamamatsu Photonics ...
-
bioRxiv - Genetics 2023Quote: ... 0.25 µm Z-slices were taken from the top to the bottom of each phasmid neuron using the cellSens software (Olympus America Inc.). All images were taken at the same laser intensity and exposure time.
-
bioRxiv - Neuroscience 2023Quote: ... A consistent Z-plane was held in focus for the entire imaging session using the continuous focus function of a Z drift compensator (Olympus, IX3-ZDC2) controlled remotely by MetaMorph ...
-
bioRxiv - Physiology 2023Quote: IHC images were obtained using the 60 X silicon objective with 1-7 x software zoom and 0.45 μm z-step size on an Olympus FV-3000 laser-scanning confocal system (Olympus, Shinjuku, Tokyo, Japan) or an Olympus IX-83 inverted microscope controlled by Olympus FV31S-SW software (Version 2.3.1.163 ...
-
bioRxiv - Neuroscience 2024Quote: ... Low-resolution whole-cell images of the anti-GFP labeled channel were obtained by obtaining a z-stack with a 10x objective (Olympus, NA=0.4).
-
bioRxiv - Zoology 2024Quote: ... detailed morphology was further confirmed by acquiring fluorescence optical sections (Z-stack) using a confocal laser microscope (FV1000D IX81, Olympus, Tokyo, Japan). The fluorescence change was calculated as ΔF/ F0= (Ft – F0)/F0 ...
-
bioRxiv - Developmental Biology 2023Quote: ... confocal images at 81 z-axis planes with 1-μm increments were acquired on an IX-71 inverted microscope (Olympus Corporation, Tokyo, Japan) equipped with a CSU W-1 confocal scanner unit (Yokogawa Electric Corporation ...
-
bioRxiv - Microbiology 2020Quote: ... Slides were examined by light microscopy using an Olympus Vanox-T microscope and images were taken with a digital camera (Olympus camedia C-2020 Z).
-
bioRxiv - Neuroscience 2020Quote: ... 1 μm interval z-stacks of the optic tectum were collected on a custom-built 2-photon microscope (Olympus BX61WI with Olympus FV300 confocal scan head) outfitted with an Olympus 1.0 NA 60x water-immersion objective ...
-
bioRxiv - Neuroscience 2023Quote: ... were photographed under bright-field illumination using an Olympus BX63 light microscope with an X-Y-Z motorized stage and an attached DP74 color CMOS camera (cooled, 20.8 MP pixel-shift, 60 fps) (Olympus America, Inc., Waltham, MA, USA). Image acquisition was carried out using cellSense™ Dimension software (Version 2.3 ...
-
bioRxiv - Immunology 2020Quote: ... Z-axis resolution of about 3 μm per section was acquired with 100 μm pinhole and 60x objective lens (Olympus, LUMFLN, water immersion, NA 1.1).
-
bioRxiv - Neuroscience 2019Quote: ... 600 × 600 µm Image stacks were acquired at z intervals of 1.0 um and resampled fifteen times for each stack using a 20X objective (Olympus LUMPlanFl/IR 2x digital zoom, 1.0 NA) 30kHz resonance scanning mirrors covering the entire dendritic fields of the vDSGCs ...
-
bioRxiv - Neuroscience 2022Quote: ... 480 x 480 µm Image stacks were acquired at z intervals of 1.0 µm and resampled fifteen times for each stack using a 20X objective (Olympus LUMPlanFl/IR 2x digital zoom, 1.0 NA) and 30kHz resonance scanning mirrors covering the entire dendritic fields of the ooDSGCs ...
-
bioRxiv - Bioengineering 2023Quote: ... The two-photon microscope used for imaging rat samples was a commercial multiphoton laser scanning microscope (FV1200 inverted, Olympus Corporation, Tokyo, Japan) equipped with an ultrafast Ti:Sapphire laser (MaiTai Deepsee ...
-
bioRxiv - Microbiology 2024Quote: ... connection kit (DP21-SAL, Olympus, Japan), and hand switch (DP21-HS ...
-
bioRxiv - Immunology 2019Quote: Antibody labeled sections were imaged with epifluorescent upright scope (Olympus BX-51) equipped with DAPI ...
-
bioRxiv - Cell Biology 2022Quote: ... stained with anti-p62 antibody and observed by FV3000 confocal laser microscope system (Olympus) equipped with a 60× oil-immersion objective lens (NA1.4 ...
-
bioRxiv - Microbiology 2020Quote: ... Images of cells infected with SINV stained with J2 antibody were carried out on BX51 microscope (Olympus).
-
bioRxiv - Genetics 2024Quote: ... The spreads were stained with primary and secondary antibodies observed using a fluorescence microscope (BX51; Olympus/Evident) with a 100ξ objective (NA1.3) ...
-
bioRxiv - Cell Biology 2022Quote: ... or Alexa647-labeled goat anti-rabbit or -mouse secondary antibodies and visualized using a BX60 fluorescence microscope (Olympus) equipped with an epifluorescent lamp (Lumen Dynamics ...
-
bioRxiv - Developmental Biology 2021Quote: ... then treated with either fluorescent secondary antibodies (Thermo) and ProLong mountant (Thermo) for visualisation under a microscope (Olympus IX71), or with a biotin conjugated secondary antibody (R&D ...
-
bioRxiv - Genomics 2024Quote: ... Visualization of the antigen-antibody complexes was performed using an Olympus FV3000 Scanning Confocal Microscope (Olympus corporation, Tokyo, Japan).
-
bioRxiv - Cell Biology 2021Quote: ... bone slices were reacted with primary and Alexa 488-conjugated secondary antibodies and observed with a confocal microscope (FV1000; Olympus). For immunoblot analysis ...
-
bioRxiv - Molecular Biology 2019Quote: ... Antibodies mentioned in the antibodies and inhibitors section were used at desired dilution and imaging was carried out on FV3000 Confocal Microscope (Olympus). Image analysis and extraction of raw files was done with the Fiji software [62].
-
bioRxiv - Microbiology 2020Quote: ... Horizontal whole-lung slides of consecutive planes of SARS-CoV-2-infected and antibody-treated lungs were digitalized by Olympus histoslide scanner to create image data files that can be used for further digital image analysis (DIA) ...
-
bioRxiv - Immunology 2022Quote: ... samples were incubated overnight with 1:100 dilution of primary antibodies and were visualized after incubation with the secondary antibodies (1:200, anti-mice AF488 and anti-rabbit AF594) using the confocal microscope (Olympus FV3000) at 100X resolution ...
-
bioRxiv - Plant Biology 2020Quote: ... secondary antibody was used for detection and sections were examined on a BX61 using the Disk Scanning Unit attachment microscope (Olympus, Japan) with fluorescence functions.
-
bioRxiv - Cell Biology 2023Quote: ... images of an average of 10 random fields of dissociated adult DRG neurons fixed and immunostained with mouse anti-neurofilament antibody were acquired using a 20× objective lens (Olympus IX81) coupled to a monochrome CCD camera (Sensicam QE ...
-
bioRxiv - Physiology 2023Quote: ... Compatible fluorescent antibodies were used for detection with the Olympus IX-73 wide-field fluorescence microscope (Olympus Corp., Shinjuku, Tokyo, Japan). Analysis of immunohistochemically stained cross-sectional cuts was performed blinded using ImageJ.
-
bioRxiv - Plant Biology 2023Quote: ... Images were collected using an LSM Upgrade Kit (PicoQuant) attached to a Fluoview FV-1000 (Olympus) confocal microscope equipped with a Super Apochromat 60x UPLSAPO water immersion objective (NA 1.2 ...
-
bioRxiv - Cancer Biology 2024Quote: ... Hochest33258 staining kit was used to analyze apoptosis of glioma cells and images were photographed by Olympus BX63 Microscope ...
-
bioRxiv - Bioengineering 2023Quote: ... or goat anti-mouse CX3CR1 antibody conjugated DNA origami (0.5 μM) injected CX3CR1-eGFP animals were imaged with a 12x objective (Olympus MVPLAPO2XC/0.5 NA [WD = 6 mm]).
-
bioRxiv - Cancer Biology 2019Quote: ... For low magnification whole-body screening of tumor and antibody signals we used a 1x Olympus air objective (Olympus MV PLAPO 1x/0.25 NA [WD = 65mm]) coupled to an Olympus MVX10 zoom body ...