Labshake search
Citations for Olympus :
251 - 300 of 1234 citations for Dengue Virus Serotype 2 NS1 Protein Insect Cells since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Developmental Biology 2022Quote: AFM measurements of hair follicle basement membranes were performed on freshly cut 16 μm cryosections using JPK NanoWizard 2 (Bruker Nano) atomic force microscope mounted on an Olympus IX73 inverted fluorescent microscope (Olympus) and operated via JPK SPM Control Software v.5 ...
-
bioRxiv - Biophysics 2023Quote: ... Both lasers were combined by coupling them into a polarization maintaining single-mode fiber (P3-488PM-FC-2, Thorlabs, USA) and subsequently guided into the microscope objective (UplanSApo 60X/1.20W, Olympus, Germany) via a dual-edge dichroic mirror (ZT532/640rpc ...
-
bioRxiv - Neuroscience 2022Quote: ... Fish behaviors were filmed from the bottom 33 at 50 fps using a 2×/ NA 0.14 objective lens (Olympus, XLFLUOR) and a camera (Teledyne FLIR ...
-
bioRxiv - Neuroscience 2022Quote: ... larvae were kept in the FluoroDish inside of an incubator and reimaged at a higher-resolution at 2 dpf with a laser confocal (Olympus FV1200 ...
-
bioRxiv - Neuroscience 2022Quote: ... Slices were then placed into a submersion-type recording chamber superfused with oxygenated aCSF at 34°C on a 2-photon excitation fluorescence microscope (FV10MP, Olympus) linked to a femtosecond Ti:sapphire 80 MHz pulse laser (Vision S ...
-
bioRxiv - Developmental Biology 2024Quote: Raw digital files from 2-photon imaging were acquired and saved in the OIB format using the microscope manufacturer’s software (FLUOVIEW, Olympus USA). To capture extended fields-of-view that encompass the entire ocular surface epithelium ...
-
bioRxiv - Neuroscience 2024Quote: ... SF-iGluSnFR-A184V and jGCaMP8m imaging was performed using a FEMTOSmart Femto2D dual scan-head 2-photon microscope (Femtonics) mounted on a BX61WI stand (Olympus) under a CFI Apo LWD 1.1 numerical aperture 25× 2.0-mm objective (Nikon) ...
-
bioRxiv - Neuroscience 2024Quote: ... a FEI Tecnai G2 20 transmission electron microscope (TEM) with an accelerating voltage of 200 kV and equipped with a Veleta 2 x 2K CCD camera (Olympus) was used ...
-
bioRxiv - Neuroscience 2023Quote: ... mice were headfixed and positioned under the 2-photon microscope (Bruker Ultima2P Plus) using a 20x air objective (Olympus LCPLN20XIR). A Spectra-Physics InSight X3 tuned to 920nm was used to excite GCaMP6s through the GRIN lens ...
-
Entorhinal cortex vulnerability to human APP expression promotes hyperexcitability and tau pathologybioRxiv - Neuroscience 2024Quote: PV interneurons and excitatory cells were targeted for somatic whole-cell recording in layer 5 region of somatosensory cortex or layer 2 lateral entorhinal cortex by combining gradient-contrast video-microscopy with epifluorescent illumination on custom-built or commercial (Olympus) upright microscopes ...
-
bioRxiv - Neuroscience 2024Quote: ... The eye-monitoring camera (Guppy Pro 2 F-031, Allied Vision Technologies) used a 5x objective (Olympus MPLN, 0.1 NA) and custom image-forming optics to create a 100x100 pixel image of the left eye of the fish (6 μm/pixel) ...
-
bioRxiv - Neuroscience 2024Quote: All imaging was conducted using a 2-photon 8 kHz resonant scanner (Bruker) and high-NA multiphoton objective (XLPLN25XWMP2, 25x/1-NA, Olympus). For excitation ...
-
bioRxiv - Evolutionary Biology 2024Quote: ... Photophobic response induction and Fluo-8H excitation were performed simultaneously using cyan light (470 nm, intensity 30 μmol photons m-2 s-1) on a microscope (IX71, Olympus) at 10 fps ...
-
bioRxiv - Developmental Biology 2024Quote: ... Confocal time-lapse images were obtained with two systems as follows: a BX51W1 microscope (time intervals: 5 min, Z intervals: 2 μm) (Olympus) equipped with a CSU-X1 laser scanning confocal imaging unit (Yokogawa) ...
-
bioRxiv - Bioengineering 2022Quote: ... Images were acquired using a 20x air immersion objective with 0.45 NA (for cells on TCPS) or 0.75 NA (for cells on hydrogels) (both Olympus). ZsGreen was excited with a 488 nm laser line and detected between 500-540 nm ...
-
bioRxiv - Cell Biology 2022Quote: ... live cells were treated with 0.5mM of EDTA and live cell imaging was performed using Olympus IX81 (Olympus) microscope to capture de-adhesion of the cells from the surface ...
-
bioRxiv - Cell Biology 2020Quote: Spherical cell volume was determined after measuring the diameter of trypsinized HBEKT cells on an epifluorescence microscope (Olympus). The amount of ATP for one cell was derived from the amount of protein in one cell found via Bradford assay (BioRad).
-
bioRxiv - Microbiology 2021Quote: ... Cell or cell cluster level morphology was observed by phase-contrast microscopy using an inverted microscope (IX83, Olympus) with a camera (DP80 ...
-
bioRxiv - Cell Biology 2020Quote: ... The Cell^M/xcellence software module (Olympus) was used to quantify the relative fluorescence intensities of roGFP2 at 400 and 480 nm excitation ...
-
bioRxiv - Developmental Biology 2020Quote: TWIST2+ cells: Images were captured by Olympus BX-60 with DP72 camera at 20X ...
-
bioRxiv - Bioengineering 2020Quote: ... cells were imaged using CLSM (Olympus, FV1200).
-
bioRxiv - Cell Biology 2021Quote: ... Olympus cell sensentry was purchased from Olympus in Japan.
-
bioRxiv - Bioengineering 2020Quote: ... and cells imaged using CLSM (Olympus, FV1200). For endosomal escape ...
-
bioRxiv - Microbiology 2023Quote: ... Live cell imaging was conducted by Olympus IX73 or Olympus SpinSR system.
-
bioRxiv - Plant Biology 2022Quote: ... the cells morphologies were studied by Olympus light microscope.
-
bioRxiv - Cell Biology 2022Quote: ... The stained cells were imaged by Olympus IX51 4 x objective ...
-
bioRxiv - Cell Biology 2023Quote: ... and the Cell R diode lasers (Olympus) with wavelength 405nm (50 mW) ...
-
bioRxiv - Cell Biology 2023Quote: ... The stained cells were imaged by Olympus IX51 4 x objective ...
-
bioRxiv - Animal Behavior and Cognition 2023Quote: ... cells were observed and captured by Olympus CK51 microscope.
-
bioRxiv - Developmental Biology 2024Quote: ... and were analyzed with Cell Sens (Olympus).
-
bioRxiv - Cancer Biology 2024Quote: ... The proliferating cells were observed by Olympus IX83 microscopy and analyzed using Olympus CellSens software.
-
bioRxiv - Biophysics 2021Quote: The formation of liquid droplets was imaged on 50 μl of the N protein samples by DIC microscopy (OLYMPUS IX73 Inverted Microscope System with OLYMPUS DP74 Color Camera) as previously described (10,14) ...
-
bioRxiv - Plant Biology 2023Quote: ... The fluorescence signal for Venus protein was detected at the excitation wavelength of 514 nm using a confocal laser scanning microscope (Olympus FluoView™ FV1000). The 35S::Osr40g3-cVenus construct with an empty 35S::nVenus vector was considered as a negative control.
-
bioRxiv - Biophysics 2022Quote: The formation of liquid droplets was imaged on 50 μl of the full-length N protein or N (1-249) samples by DIC microscopy (OLYMPUS IX73 Inverted Microscope System with OLYMPUS DP74 Color Camera) as previously described (10,20,27) ...
-
bioRxiv - Cell Biology 2023Quote: Cells expressing GFP- or mCherry-tagged proteins were imaged using a confocal laser microscope (FV-3000) equipped with an objective lens UPLAPO60XOHR (NA 1.5) (Olympus, Co. Ltd., Tokyo, Japan). To determine the cell volume ...
-
bioRxiv - Cell Biology 2020Quote: ... Images of either live cells in culture or cells stained with crystal violet were taken using light microscope (Olympus). For crystal violet staining of cells ...
-
bioRxiv - Evolutionary Biology 2020Quote: ... we also used a Thoma cell counting chamber to enumerate cells under a microscope (Olympus BX 51, magnification x200).
-
bioRxiv - Pharmacology and Toxicology 2021Quote: ... The cells were imaged with Cytation 5 cell imaging multi-mode plate reader equipped with 20X LUCPLFLN objective (Olympus) from Bright-field and RFP channels (LED light source with excitation filter 531(40 ...
-
bioRxiv - Cancer Biology 2023Quote: ... with cells being imaged using phase-contrast time lapse microscopy using the IX81 inverted live cell light microscope (Olympus) equipped with MetaMorph time lapse software (Molecular Devices) ...
-
bioRxiv - Evolutionary Biology 2021Quote: ... a wing was removed and photographed at 509 magnification using a digital camera attached to a compound microscope (Olympus BH-2). The length and depth of each wing were then measured using ImageJ version 1.48 (http://imagej.nih.gov/ij/) ...
-
bioRxiv - Bioengineering 2020Quote: ... such that the cervical vagus nerve was in the conjugate plane at the focus of the objective lens (0.4 NA, Olympus USLSAPO10×2). Fluorescence emission from the sample was collected in the epi-direction ...
-
bioRxiv - Immunology 2021Quote: ... T cells stained with Alexa Fluor 488-labeled anti-CD45.2 Fab (clone 104-2) were then added to the arrays and imaged using an inverted fluorescence microscope (Olympus IX-81) fitted with a 100× objective lens and a mercury lamp for excitation ...
-
bioRxiv - Neuroscience 2020Quote: ... the whole brain preparations were imaged on a Bergamo II resonant-scanning 2-photon microscope (ThorLabs Inc., Newton, NJ) using a SemiApo 20x (1.0 NA) water-immersion objective lens (Olympus, Tokyo, Japan). The illumination source was an Insight X3 IR laser (Spectra-Physics ...
-
bioRxiv - Developmental Biology 2022Quote: ... Ratiometric Ca2+ imaging was performed at 340 and 380 nm in 0 or 2 mM Ca2+ Ringer’s solution using an IX81 microscope (Olympus, Tokyo, Japan) at room temperature ...
-
bioRxiv - Genetics 2022Quote: ... Dopaminergic neurons in the brains were subjected to time-lapse imaging at an interval of 2 seconds (Olympus FV3000 confocal microscope, Olympus Corp) using 40X magnification ...
-
bioRxiv - Neuroscience 2020Quote: ... IHCs were visualized with fixed stage microscopes (Examiner or Axioskop 2 FS Plus, both Zeiss, Germany or BX50WI and BX51, Olympus, Japan) equipped with 63x/1.0 DIC (Zeiss ...
-
bioRxiv - Biophysics 2021Quote: ... P1-488PM-FC-2) before being focused on the back focal plane of a 1.45 NA oil objective (UAPON 150XOTIRF, Olympus America Inc.). TIRF excitation of the sample was achieved by translating the laser close to the edge of the objective back aperture ...
-
bioRxiv - Cell Biology 2021Quote: ... Then the oocytes were washed again 2-3 times in fresh M2 medium and the signal was examined immediately by a fluorescence microscope (Olympus, IX73). Images of the control and PFNA-treated oocytes were taken using the same imaging parameters ...
-
bioRxiv - Neuroscience 2022Quote: ... Filled neurons green (dnKv4.2-negative) and green/red (dnKv4.2-positive) were imaged at multiple Z-planes using a two-photon microscope (Olympus FV1000-MPE) with a multiimmersion objective lens (ULTRA 25x ...
-
bioRxiv - Bioengineering 2023Quote: ... Cell viability images (figures 2 and 5) were acquired with an inverted microscope (Etaluma LS720) with a 4x phase contrast objective (Olympus, UPLFLN4XIPC) inside an incubator ...