Labshake search
Citations for Olympus :
9501 - 9550 of 10000+ citations since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cell Biology 2021Quote: ... Keratin networks for Figure 1–figure supplement 1 were imaged using a spinning disk confocal laser scanning microscope (Olympus IXplore SpinSR10 with YOKOGAWA CSU-W1 spinning disk) ...
-
bioRxiv - Cell Biology 2021Quote: ... 3D confocal stacks were acquired with a UPLSAPO UPlan S Apo 60x/1.3 OIL objective (Olympus). Fluorescent proteins were excited at 405 nm (50 mW ...
-
bioRxiv - Cell Biology 2021Quote: ... conjugated to Alexafluors 488 or 594 were used for detection using a BX51 microscope (Olympus, Hertfordshire, UK) equipped with a Q-Imaging camera (Micro Imaging Applications Group ...
-
bioRxiv - Developmental Biology 2021Quote: ... sgRNAs and the targeting vector were introduced into cytoplasm and the larger male pronucleus of C57BL/6 mouse zygotes by an inverted microscope (OLYMPUS IX71) equipped with a micro-injector system (Eppendorf FemtoJet 4i) ...
-
bioRxiv - Developmental Biology 2021Quote: ... conjugate the pupils of O1 and O2 so that an intermediate image of the sample at O1 is formed at the secondary objective O2 (Olympus UPLXAPO20X). The intermediate image has a uniform magnification of 1.33 ...
-
bioRxiv - Developmental Biology 2021Quote: ... A primary objective (O1, Olympus XLUMPLFLN 20XW NA1.0, water) is used to both generate an oblique light-sheet in the sample and to collect the fluorescence ...
-
bioRxiv - Developmental Biology 2021Quote: ... microscope equipped with a Veleta camera (Olympus, Japan).
-
bioRxiv - Immunology 2021Quote: ... Images were acquired on a Zeiss Axio Observer Z1 inverted microscope (Olympus) and analysed with TissueFAXS imaging and TissueQuest quantitation software (TissueGnostics).
-
bioRxiv - Immunology 2021Quote: ... individual image channels were acquired with an Olympus FluoView 500 laser scanning confocal microscope (Olympus, Life Sciences Waltham, MA) maintained by the University of Pittsburgh’s Center for Biologic Imaging and combined and pseudocolored with the FIJI build of ImageJ (Schindelin et al. ...
-
bioRxiv - Neuroscience 2021Quote: ... were used and stainings examined under an inverted fluorescence microscope (Olympus CKX41, Leica DMI6000) or for confocal and large-scale tiling images taken with a cooled EMCCD camera (Rolera-MGi PLUS ...
-
bioRxiv - Cell Biology 2021Quote: ... at 80 kV equipped with a Veleta 2k × 2k CCD camera (Olympus, Tokyo, Japan).
-
bioRxiv - Cell Biology 2021Quote: ... at 80 kV with a CCD Veleta 2K × 2K camera (Olympus).
-
bioRxiv - Cell Biology 2021Quote: ... The cauda epididymal spermatozoa were dispersed in the TYH medium and observed under an Olympus BX53 phase contrast microscopy (Olympus, Tokyo, Japan).
-
bioRxiv - Cell Biology 2021Quote: ... Images were acquired every 4 s before and after ablation of a single interface using a 60x oil immersion lens (Olympus, NA 1.35). The positions of the tricellular vertices connected by the ablated interface were manually tracked prior to and for 36 seconds following ablation using the image analysis platform SIESTA (Fernandez-Gonzalez and Zallen ...
-
bioRxiv - Cell Biology 2021Quote: ... using a 60x NA 1.42 PlanApo oil immersion objective (Olympus). To minimise artefacts due to spherical aberration
-
bioRxiv - Cell Biology 2021Quote: ... Deconvolution wide-field microscopy was performed using the DeltaVision Elite system equipped with an NA 1.42 60x PlanApo objective (Olympus) and an sCMOS 2048 × 2048 camera (Leica Microsystems) ...
-
bioRxiv - Cell Biology 2021Quote: ... Microscopy was performed using the DeltaVision Elite system equipped with an NA 0.75 U Plan S-Apo objective (Olympus) and an sCMOS 2048 × 2048 camera ...
-
bioRxiv - Cell Biology 2021Quote: ... phase-contrast microscopy (Hoffman Modulation Contrast - Olympus IX70 with a DP71 digital camera) was used to capture images in order to measure the size of multiple individual organoids (53-104 individual organoids per condition) ...
-
bioRxiv - Cell Biology 2021Quote: Images of cells transiently expressing GFP-COL and showing TANGO1L and GM130 were obtained through widefield microscopy using an Olympus IX-71 inverted microscope (Olympus, Southend, UK) as described previously (McCaughey et al. ...
-
bioRxiv - Cell Biology 2021Quote: ... Images were acquired with a 100× 1.4 NA objective (Olympus) on a DeltaVision Elite High-Resolution Microscope (GE Healthcare Life Sciences ...
-
bioRxiv - Cell Biology 2021Quote: ... Images were acquired with a 100× 1.4 NA objective (Olympus) on a DeltaVision Elite High-Resolution Microscope (GE Healthcare Life Sciences) ...
-
bioRxiv - Cell Biology 2021Quote: ... Fluorescent images were taken using confocal FV3000 (Olympus). Polygon selection tool was used to select coelomocytes’ area to be quantified and average pixel intensity was calculated with the “analyze-measure” command ...
-
bioRxiv - Cell Biology 2021Quote: ... Samples were analyzed without further contrast enhancement using a Philips EM 400T electron microscope at 60 kV equipped with a CCD camera (MORADA, Olympus, Hamburg, Germany). TEM images were analyzed using NIH ImageJ software.
-
bioRxiv - Cell Biology 2021Quote: ... The staining images were taken using a microscope (IX73, Olympus) and analyzed with ImageJ software (NIH).
-
bioRxiv - Cell Biology 2021Quote: ... FRAP experiments were performed using a confocal microscope (FV1000, Olympus) with a 60x oil immersion objective lens on cells treated in advance with siRNAs for control or for eEF2 for 36 hours before the experiments ...
-
bioRxiv - Cell Biology 2021Quote: ... Images were acquired using a microscope (IX73, Olympus) or a confocal laser scanning microscope (FV1000 ...
-
bioRxiv - Cell Biology 2021Quote: ... or a confocal laser scanning microscope (FV1000, Olympus) equipped with a UPlan Apo 60x oil objective lens (NA = 1.42 ...
-
bioRxiv - Cell Biology 2021Quote: ... Immunostained cells were observed using a FV1000 confocal fluorescence microscope system (Olympus).
-
bioRxiv - Neuroscience 2021Quote: ... Ca2+ imaging was performed at 32-34 °C using a two-photon microscope (Olympus Fluoview 1000, Olympus) coupled to a mode-locked Ti-Sapphire laser working at a wavelength of 710-990 nm (MaiTai ...
-
bioRxiv - Neuroscience 2021Quote: ... coupled to a mode-locked Ti-Sapphire laser working at a wavelength of 710-990 nm (MaiTai, Spectra Physics) and equipped with a water-immersion objective (Olympus 60x, 1.0 NA). The emission signals of GCaMP6f and S101 were split by a 570 nm dichroic mirror and sent through the BP 536/40 and BP 630/92 filters ...
-
bioRxiv - Neuroscience 2021Quote: ... Ca2+ imaging was performed at 32-34 °C using a two-photon microscope (Olympus Fluoview 1000, Olympus) coupled to a mode-locked Ti-Sapphire laser working at a wavelength of 710-990 nm (MaiTai ...
-
bioRxiv - Genomics 2021Quote: ... Microscopic confocal sections were taken on Confocal Laser Scanning Microscope FV3000 (Olympus, Tokyo, Japan) and images were processed with ImageJ.
-
bioRxiv - Neuroscience 2021Quote: ... targeted whole-cell recordings of transfected CA3 pyramidal neurons were performed at room temperature (21-23°C) under visual guidance using a BX 51WI microscope (Olympus) and a Multiclamp 700B amplifier (Molecular Devices ...
-
bioRxiv - Neuroscience 2021Quote: ... Slices were imaged using a VS120 microscope (Olympus), at 10x magnification with two channels ...
-
bioRxiv - Neuroscience 2021Quote: ... and through the oil immersion condenser (numerical aperture 1.4, Olympus) by GaAsP photomultiplier tubes (Hamamatsu ...
-
bioRxiv - Neuroscience 2021Quote: ... Red fluorescence was detected through the objective (LUMPLFLN 60XW, 60x, 1.0 NA, Olympus) and through the oil immersion condenser (numerical aperture 1.4 ...
-
bioRxiv - Neuroscience 2021Quote: ... and through the oil immersion condenser (numerical aperture 1.4, Olympus) by photomultiplier tubes (H7422P-40SEL ...
-
bioRxiv - Neuroscience 2021Quote: ... Red and cyan fluorescence were detected through the objective (Olympus LUMPLFLN 60XW ...
-
bioRxiv - Neuroscience 2021Quote: ... Images were obtained and analyzed using light microscopy (Olympus BX61) with a 4x magnification ...
-
bioRxiv - Genomics 2021Quote: ... equipped with a 60x 1.45 numerical aperture (NA) lens (Olympus) and cooled CoolSnap CCD camera ...
-
Glycogen Synthase Kinase 3 regulates the genesis of the rare displaced ganglion cell retinal subtypebioRxiv - Neuroscience 2021Quote: ... they were mounted on slides and imaged using a scanning confocal microscope (Olympus, FV1000). Primary and secondary antibodies are listed in Supplementary Table 1.
-
bioRxiv - Genomics 2021Quote: ... The expression pattern of LYVE1 in liver slides was acquired by Olympus BX63 microscope (Olympus, Shinjuku, Japan) at 200x magnification.
-
bioRxiv - Genomics 2021Quote: ... The expression pattern of LYVE1 in liver slides was acquired by Olympus BX63 microscope (Olympus ...
-
bioRxiv - Genomics 2021Quote: ... Images were acquired using a 100x 1.4 NA Plan Apochromatic oil immersion objective (Olympus) and captured using a CoolSnap HQ CCD camera (Photometrics) ...
-
bioRxiv - Genomics 2021Quote: Imaging was performed using IX70 (Olympus) microscope with a DeltaVision core system (Applied precision ...
-
bioRxiv - Genomics 2021Quote: ... Images were taken using an Olympus FV-1000 confocal microscope (Olympus America Inc, Center Valley, USA) and relative signal intensities were quantified using ImageJ software.
-
bioRxiv - Genomics 2021Quote: ... three slides were examined under an inverted light microscope (Olympus FSX100, Olympus Corporation, Japan), and the cuticle thickness of these five ascaridiod species were then measured and compared ...
-
bioRxiv - Genomics 2021Quote: ... three slides were examined under an inverted light microscope (Olympus FSX100, Olympus Corporation, Japan), and the cuticle thickness of these five ascaridiod species were then measured and compared ...
-
bioRxiv - Neuroscience 2021Quote: All Ca2+ imaging was performed using a 40× 0.8 NA objective (LUMPlanFLN-W, Olympus) and a custom two-photon microscope with an articulating objective arm ...
-
bioRxiv - Genomics 2021Quote: ... Images were acquired at 20X with 2X digital zoom using a FV3000 confocal laser scanning microscope (Olympus) and processed using HALO software (Indica Labs ...