Labshake search
Citations for Olympus :
651 - 700 of 915 citations for Trisodium dichloroanthra 2 1 9 mna naphth 2 3 h acridine 5 10 15 triyl tris sulfate since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2024Quote: ... 5% CO2) was achieved with a top mount on-stage incubator (Okolab uno stage-top incubator, H391-Olympus-IX-SUSP 2015). Regions of interest were selected for low to moderate RIBEYE-GFP expression ...
-
bioRxiv - Bioengineering 2024Quote: ... The units were incubated and matured for up to 5 days while being observed under a stereomicroscope (SZX16, Olympus, Tokyo, Japan) or a fluorescence imaging system (THUNDER Imaging System ...
-
bioRxiv - Neuroscience 2020Quote: ... Sections were imaged on a laser-scanning confocal microscope with a 10× 0.45 NA air objective (Olympus). Values for ‘area’ ...
-
bioRxiv - Microbiology 2020Quote: ... The microscope was equipped with an Olympus MVX-10 zoom body (magnification range: 0.63x – 6.3x, total magnification: 1.26x – 12.6x; Olympus, Japan), an Olympus MVPLAPO 2x objective (NA = 0.5) ...
-
bioRxiv - Biochemistry 2022Quote: ... using two different types of short cantilevers (USF-F1.2-k0.15-10, NanoWorld: a spring constant ∼0.15 N/m, a resonance frequency ~ 0.6 MHz, AC-7, Olympus: a spring constant ~0.1Nim ...
-
bioRxiv - Biophysics 2022Quote: OMCL-TR400PB-1 cantilevers (Olympus) were used to probe the interaction between TnpAWT ...
-
bioRxiv - Biophysics 2024Quote: ... 20X objective (1-U2M345, Olympus), 1.40 NA/40X oil immersion objective (1-UXB220 ...
-
bioRxiv - Biophysics 2021Quote: All imaging was performed at 37° C in 5% CO2 with an IX71 inverted fluorescence and Differential Interference Contrast (DIC) microscope (Olympus, Melville, NY), controlled with MetaMorph software (Molecular Devices ...
-
bioRxiv - Cell Biology 2022Quote: ... the motion of nanoparticles embedded inside the cells was recorded for a total of 5 s at 100 frames per second using an inverted fluorescence microscope (Olympus IX81; Olympus) equipped with a 100× oil immersion objective (N.A ...
-
bioRxiv - Cancer Biology 2022Quote: ... The migrating cells were examined microscopically and determined by counting the migrating/invasive cells in 5 randomly selected fields using an Olympus BX41 microscope (Olympus, Waltham, MA).
-
bioRxiv - Pharmacology and Toxicology 2021Quote: ... Post-treatment cells were stained with DCFDA-H2 (5 μM) at 37°C in dark and images were acquired with a confocal microscope (Olympus IX84, Japan). All parameters (pinhole ...
-
bioRxiv - Cancer Biology 2021Quote: ... Montage images (5 × 4) of cells were acquired on a BD Pathway 855 microscope using a 10x objective (Olympus, UplanSApo 10x/0.40). The empty space in the well was defined with Pipeline Pilot software using a custom analysis protocol that determines empty space via a threshold of pixel intensity ...
-
bioRxiv - Immunology 2023Quote: ... The images of 5 fields of every section were observed and captured with an optical microscope equipped with a camera (Olympus, Tokyo, Japan). The semi-quantitative analysis was determined by ImageJ software and shown as H-score [40 ...
-
bioRxiv - Bioengineering 2024Quote: ... The samples were rinsed with PBS at least 5 times and the captured cells were stained by DAPI and examined by fluorescent microscopy (BX51, Olympus Corporation, Japan) with 3 different views ...
-
bioRxiv - Bioengineering 2024Quote: ... The samples were rinsed with PBS at least 5 times and the captured cells were stained by DAPI and examined by fluorescent microscopy (BX51, Olympus Corporation, Japan) with 3 different views ...
-
bioRxiv - Neuroscience 2023Quote: ... and the percentage of positive cells of each slice was calculated from the average value of 5 randomly selected fields under a fluorescence microscope (OLYMPUS, FV3000, Japan). The average of three sequential slices from rostral to caudal represented the data for individual mouse ...
-
bioRxiv - Plant Biology 2024Quote: The gemmae expressing EST-inducible MpRLF-GFP were counterstained with 10 µg/ml of propidium iodide (PI) for 5 minutes and observed by confocal laser scanning microscopy using an Olympus FV1000 confocal microscope (Olympus/Evident, Japan). The 473 nm line and the 559 nm line of an LD laser were used to excite GFP and PI ...
-
bioRxiv - Neuroscience 2020Quote: ... images were taken on a laser-scanning confocal microscope with a 10× 0.45 numerical aperture (NA) air objective and a 60× 1.35 NA oil-immersion objective (Olympus).
-
bioRxiv - Bioengineering 2020Quote: ... Cells were cultured for 10 days to enable colony formation before imaging on an IX83 inverted microscope (Olympus). Colony types were identified manually by blinded researchers by comparing to gold-standard images provided by the vendor ...
-
bioRxiv - Neuroscience 2021Quote: Sections were imaged using an Olympus BX53 microscope with a 4× (NA 0.16) or 10× (NA 0.4) objective lens equipped with a cooled CCD camera (DP80; Olympus) or Zeiss Axio Scan.Z1 with a 20× (NA 0.8 ...
-
bioRxiv - Neuroscience 2020Quote: ... and imaged using an Olympus IX-81 epi-fluorescent microscope with a 4× and 10× objective lens (0.16 and 0.3 NA; Olympus). Fiber tracks and GCaMP6f expression were detected in all mice and were mainly localized to the MGB (Fig ...
-
bioRxiv - Neuroscience 2021Quote: ... and 647-nm diode laser lines, and UPLSAPO 10× (NA, 0.4), and PLAPON 60×OSC2 (NA, 1.4; oil immersion) objective lenses (FV1200, Olympus). Image and pinhole size were 800 × 800 pixels and 1 airy unit ...
-
bioRxiv - Cell Biology 2021Quote: ... and 10 μL stained cells loaded on a hemocytometer were imaged using a Zeiss AxioImager M2 (10x Olympus objective equipped with a Hamamatsu Orca R2 camera ...
-
bioRxiv - Neuroscience 2021Quote: ... Immunoreactivity was examined on a laser-scanning confocal microscope with a 10× 0.45 numerical aperture (NA) air objective and a 60× 1.35 NA oil-immersion objective (Olympus).
-
bioRxiv - Neuroscience 2021Quote: c-Fos-positive cells were visualized under a 10× objective by using a light microscope (Olympus BX50, Japan) coupled to an Olympus camera (DP72 ...
-
bioRxiv - Pharmacology and Toxicology 2021Quote: ... with a 10 x objective (mouse sperm) and a 20 x objective (human sperm) (UPLSAPO, NA 0.8; Olympus) was combined with a high-speed camera (ORCA Fusion ...
-
bioRxiv - Plant Biology 2023Quote: ... After 10 min viable pollen grains in 20 µl solution were counted under bright-field microscope (Olympus BX43). Round and dark blue were considered as viable pollen grains ...
-
bioRxiv - Genomics 2023Quote: ... Brightfield histology images were taken using a 10× objective on a slide scanner (Olympus VS-120 Slide scanner). For tissue optimization experiments ...
-
bioRxiv - Cell Biology 2024Quote: ... Images were taken at 10× magnification using an Olympus BX51 microscope equipped with an Olympus DP71 camera (Olympus). Using ImageJ ...
-
bioRxiv - Cell Biology 2024Quote: ... Images were taken at 10× magnification using an Olympus BX51 microscope equipped with an Olympus DP71 camera (Olympus). p16Ink4a and DAPI images were merged using ImageJ ...
-
bioRxiv - Neuroscience 2024Quote: ... Comprehensive imaging of these slices was initially performed with a 10× objective on a fluorescent microscope (VS120, Olympus). Regions showing statistically significant differences were then imaged in greater detail using a 20× objective on a confocal microscope (FV300 ...
-
bioRxiv - Neuroscience 2023Quote: ... The soma of TdTomato+ cells was counted manually by a blind experimenter using FV-10 Fluoview viewer (Olympus). Cell density was calculated as the number of cells per a box of 50X635X635μm (and was normalized to cells/mm3) ...
-
bioRxiv - Biochemistry 2023Quote: ... the cells were counterstained with DAPI for 10 min and imaged with an Olympus BX63 microscope (Olympus, Japan).
-
bioRxiv - Neuroscience 2024Quote: Sections were imaged using an Olympus BX53 microscope with a 4× (NA 0.16) or 10× (NA 0.4) objective lens equipped with a cooled CCD camera (DP80; Olympus) or a Zeiss Axio Scan.Z1 with a 10× (NA 0.45 ...
-
bioRxiv - Developmental Biology 2024Quote: ... we employed a 10×0.6 SV MP water immersion objective with 0.8 NA and a working distance of 8 mm (OLYMPUS). The voxel size used in this configuration was 0.26×0.26×0.8 µm3 ...
-
bioRxiv - Cell Biology 2021Quote: ... cells were placed in a humidified chamber with 5% CO2 at 37 °C and imaged using a 60X oil immersion objective (Olympus, Shinjuku, Tokyo, Japan). The actin signal was photobleached in the green channel (488nm ...
-
bioRxiv - Pathology 2021Quote: ... cells were stained with DAPI for 5 minutes at room temperature in the dark and observed with fluorescence microscopy (BX-40, Olympus/Axiocam 305, Zeiss).
-
bioRxiv - Microbiology 2020Quote: Mangrove canopy cover at each sample point was determined by digital image analysis using the free-ware program ImageJ.48 Images were acquired with a digital camera (Olympus Tough TG-5) at a ratio of 4 ...
-
bioRxiv - Genetics 2022Quote: ... Weekly photographs of each fragment (top-down and side-views from all four sides of each tile) were taken using an Olympus TG-5 (Olympus, Shinjuku, Tokyo, Japan) in an underwater housing mounted to a PVC stand with attached scale bar ...
-
The Arabidopsis MCTP member QUIRKY regulates the formation of the STRUBBELIG receptor kinase complexbioRxiv - Plant Biology 2022Quote: ... 6-days-old seedlings of different genotypes carrying the pGL2::GUS:GFP reporter were counterstained with 5 μg/ml propidium iodide and examined using a FV3000 confocal laser scanning microscope (Olympus Europe, Hamburg, Germany). A high sensitivity detector (HSD ...
-
bioRxiv - Cancer Biology 2024Quote: The cell images were captured using bright field microscopy with a GXCAM-U3-5 industrial camera using different magnifications (Olympus CKX53 inverted microscope, Olympus Life Sciences, UK).
-
bioRxiv - Biophysics 2021Quote: ... An inverted microscope (1×73; Olympus) with a conforcal unit (CSU10 ...
-
bioRxiv - Neuroscience 2023Quote: ... a 2x/0.08NA (Olympus, 1-U2B921) objective provided an overview for a very large field of view (FOV ...
-
bioRxiv - Cell Biology 2020Quote: ... The relocalization intensity of GFP fused proteins at the damage sites were analyzed using FV-10 ASW3.1 software (Olympus). All images were captured using 60X oil objective lens ...
-
bioRxiv - Developmental Biology 2021Quote: ... The sample was illuminated with a light-sheet created by two long working objectives (Olympus 10 X, 0.3 NA) on the opposite side and two orthogonal fluorescence collection objectives (Nikon ...
-
bioRxiv - Neuroscience 2020Quote: ... and UPlanSApo (10×/0.40), UPlanSApo (20×/0.75) and PlanApoN (60×/1.4, oil immersion) objective lenses (FV1200; Olympus, Tokyo, Japan). To avoid crosstalk between multiple fluorophores ...
-
bioRxiv - Cell Biology 2021Quote: ... Cleanup 640/10) was focused onto the back focal plane of the oil-immersion objective (Olympus, 60x, NA 1.45). Emission light was separated from the illumination light using a dichroic mirror (Semrock ...
-
bioRxiv - Neuroscience 2020Quote: ... Microdissection of the cortex to include the somatosensory areas was performed using a fluorescent dissection microscope (Olympus, MVX 10). Dissected cortices were collected in a 15mL falcon tube containing 1.5mL of ACSF sorting solution containing 1%FBS and DNase and cells were dissociated by gently triturating ten times with a large ...
-
bioRxiv - Pathology 2021Quote: ... and the excited fluorescence is detected by an inverted microscope which consists of a plan achromat objective lens (Plan Fluor, 10×/0.3 NA, Olympus) and an infinity-corrected tube lens (TTL180-A ...
-
bioRxiv - Neuroscience 2023Quote: Mounted brain slices were imaged with Olympus FV3000 confocal microscope with ×10/0.6 NA water immersion objective (XLUMPlanFI, Olympus). Images were acquired using Fluoview.