Labshake search
Citations for Olympus :
601 - 650 of 765 citations for Acetamide N 5 bis 2 hydroxyethyl amino 2 2 chloro 4 6 dinitrophenyl azo 4 methoxyphenyl since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2024Quote: ... Images were captured at a rate of two images per second using cantilevers featuring a 0.1 N/m spring constant and a resonance frequency in water of 0.6 MHz (BL-AC10DS; Olympus, Tokyo, Japan). To acquire high-resolution images ...
-
bioRxiv - Microbiology 2024Quote: ... Images were collected in imaging buffer with biolever mini tips (Olympus, k ∼ 0.1 N/m, fo ∼ 30 kHz in fluid) on a commercial instrument using tapping mode (Cypher ...
-
bioRxiv - Genetics 2024Quote: ... Eclosion was recorded at 20 min intervals using a compact digital camera (Tough TG-6, Olympus). A dim red LED light (Kaito denshi ...
-
bioRxiv - Cell Biology 2021Quote: TIRFM was performed using a Till PHOTONICS iMIC microscope equipped with an oil‐ immersion objective (Apo N 100×, NA1.49 Olympus America Inc.), a heating chamber maintained at 37°C and two cameras ...
-
bioRxiv - Bioengineering 2020Quote: ... the pre-ExM cells were imaged under a wide field microscope with a 20X air objective (Olympus, UPlanFL N, 0.5 NA). Based on the DAPI signal ...
-
bioRxiv - Neuroscience 2022Quote: ... Neurons were visualized with an upright microscope (Scientifica, Uckfield, East Sussex, UK) using a LUMPlanFL N × 40/0.80 NA W objective (Olympus, Waltham, MA). Recordings from GPe neurons were obtained using micropipettes (2–4MΩ ...
-
bioRxiv - Neuroscience 2021Quote: ... the fiber’s distal end was introduced into the experimental chamber beneath a 60X water-immersion objective lens (LUMPlanFL N, numerical aperture 1.0, Olympus, Tokyo,Japan). The incidence angle of about 20° with respect to the horizontal ensured that the fiber cleared both the upper edge of the experimental chamber and the lower rim of the lens (Fig ...
-
bioRxiv - Pharmacology and Toxicology 2022Quote: ... We evaluated two tissue sections per mouse (n = 3 per group) by using a light microscope (BX50; Olympus Co., Tokyo, Japan) with the cellSens imaging software ...
-
bioRxiv - Biophysics 2024Quote: ... Measurements were performed in AC mode on a scan area of 3 x 3 µm with a micro cantilever (νres = 110 kHZ, kspring = 9 N/m, Olympus Corp.). Leveling ...
-
bioRxiv - Biochemistry 2024Quote: ... using a PLAPON 60x oil immersion objective (NA 1.42) and Immoil FC30CC immersion oil (Olympus Life Science, n= 1.518, 23°C). Fluorophores used were ...
-
bioRxiv - Cancer Biology 2024Quote: ... CD73 and β-catenin staining was manually quantified across n = 15-30 20x images per tumor section using cellSens software (Olympus).
-
bioRxiv - Physiology 2023Quote: ... Photographs were then taken from the dorsal side for body color measurement (TG-6, Olympus, Tokyo, Japan). Three sites (P1-P3 ...
-
bioRxiv - Genomics 2020Quote: ... and imaged using an Olympus BX53 compound microscope with LMPLan N 20X air objective using a DP73 c-mount camera at 0.5X magnification (Olympus Corporation, Tokyo, Japan). CellSens Dimension software (Olympus Corporation ...
-
bioRxiv - Bioengineering 2021Quote: ... an optical train consisting of a cylindrical lens in conjunction with a 4x objective lens (4X Plan Apochromat Plan N, Olympus, Tokyo, Japan) is used to produce a collimated cylindrical light-sheet with Gaussian intensity distribution ...
-
bioRxiv - Cell Biology 2021Quote: ... Images were acquired with a CMOS camera (C11440, Hamamatsu Photonics, Hamamatsu, Japan) on a 60x oil objective (60x PlanApo N, Olympus, Tokyo, Japan). The microscope was controlled with MetaMorph (Molecular Devices ...
-
bioRxiv - Microbiology 2021Quote: ... Images were acquired every 1 min for 90 min using a 60X RING-TIRF-FM objective (Olympus Apo N 60X 1.49 Oil) with an exposure time of 100 ms ...
-
bioRxiv - Neuroscience 2023Quote: ... exposure length was 200 ms except for Figure 6A where exposure length was 300 ms and the objective was 60X (Olympus UPlanFL N) rather than 25X ...
-
bioRxiv - Neuroscience 2023Quote: ... brain slices containing hM4Di-mCherry-expressing SST cells in M1 were transferred to an upright microscope (Scientifica, Uckfield, UK) and visualized using a LUMPlanFL N×40/0.80 NA water immersion objective (Olympus, Waltham, MA, USA). For fluorescence imaging ...
-
bioRxiv - Biophysics 2024Quote: ... surface-immobilized samples were illuminated in the evanescent mode through a high numerical-aperture oil-immersion objective (Olympus PlanApo N, 60x/1.45) using red laser excitation at 638nm modulated by an acoustic optical tunable filter (Gooch&Housego ...
-
bioRxiv - Neuroscience 2024Quote: All images were acquired on an Olympus Fluoview 1000 laser-scanning confocal microscope using a 40x/1.10 NA FUMFL N objective (Olympus, Center Valley, PA) at the Advanced Science Research Center (ASRC-CUNY) ...
-
bioRxiv - Bioengineering 2024Quote: Our home-built light sheet microscope features a single-side illumination pathway consisting of a cylindrical lens (LJ1695RM, Thorlabs) and 4x objective lens (4X Plan Apochromat Plan N, Olympus, Tokyo, Japan) to collimate cylindrical light sheet ...
-
bioRxiv - Evolutionary Biology 2024Quote: ... This manipulation was repeated until an amoeba cell was found in the droplet under 20x brightfield microscopy observation (OLYMPUS CKX53, LCAch N). After confirming the amoebae were in the droplets ...
-
bioRxiv - Developmental Biology 2022Quote: ... 3D images of ciliary mCherry and GCaMP6 as well as cytoplasmic GCaMP6 were obtained for 17 min at a time resolution of 6.6 s with an IX83/CSU-W1 microscope equipped with a 60× lens (UPLSAPO 60XW 1.2 N.A., Olympus). During application of the stimuli with optical tweezers as described above ...
-
bioRxiv - Neuroscience 2021Quote: A 6×12 tile image of the sample was taken in three colors at 10x magnification (Olympus UPLSAPO10X2) with sequential excitation using 405 ...
-
bioRxiv - Microbiology 2020Quote: ... 5% CO2 in vented 75 cm2 tissue culture flasks (Olympus), until the cells were 80-90% confluent ...
-
bioRxiv - Genomics 2020Quote: ... 5% CO2 in vented 75 cm2 tissue culture flasks (Olympus), until the cells were 80-90% confluent ...
-
bioRxiv - Bioengineering 2024Quote: ... a 1-inch focused 5 MHz transducer (A310S-SU, Olympus) used for sample displacement was installed on the aforementioned 3D-printed mount and aligned to the 20 MHz transducer by maximizing the US signal obtained when probing a carbon fiber ...
-
bioRxiv - Biophysics 2020Quote: ... reflected by a 455 nm long-pass dichroic (Chroma, Bellows Falls, VT) through a 40X water-immersion objective (LUMPlan FL N, Olympus, Center Valley, PA); emission was collected through the dichroic and a 475 nm long-pass filter (Chroma) ...
-
bioRxiv - Biophysics 2021Quote: The formation of liquid droplets was imaged on 50 μl of the N protein samples by DIC microscopy (OLYMPUS IX73 Inverted Microscope System with OLYMPUS DP74 Color Camera) as previously described (10,14) ...
-
bioRxiv - Neuroscience 2021Quote: ... The fiber stubs collecting fluorescent light were butt-coupled to a patch fiber and the light back-emitted from the patch fiber was collected by a microscope objective (Olympus Plan N 40x); a BPF (Semrock FF03-525/50-25 ...
-
bioRxiv - Neuroscience 2023Quote: ... Time-lapse in vivo imaging was conducted using a CSU-X1 confocal microscope (Yokogawa, Tokyo, Japan) with 40x (Olympus LUMPLanFL N 40x / 0.80W) objective ...
-
bioRxiv - Neuroscience 2023Quote: ... Widefield epifluorescence imaging of GCaMP6s in the ferret was achieved with a Zyla 5.5 sCMOS camera (Andor) controlled by µManager [55] through a 4x air-immersion objective (Olympus, UPlanFL 4x N/0.13NA) and images were acquired at 15 Hz with 4×4 binning to yield 640×540 pixel images.
-
bioRxiv - Neuroscience 2023Quote: ... were induced by applying a train of single pulses (0.2 ms) of full-field illumination of blue light through the 60x objective (Olympus LUMplanFL N 60x/1.00W) with interval of 250 ms ...
-
bioRxiv - Plant Biology 2021Quote: ... and 6-8 h later YFP signals were detected under confocal laser scanning microscope (FV 1000 Olympus, Tokyo, Japan). Excitation and emission wavelengths for YFP are 515 nm and 527 nm ...
-
bioRxiv - Bioengineering 2021Quote: ... The fs laser (Spectra-Physics, Solstice-Ref-MT5W, 800 nm, 130 fs) was irradiated through an objective lens (×10, Olympus Plan N, 0.25 NA) on the thin-glass sheet ...
-
bioRxiv - Biophysics 2020Quote: ... The rolling behavior of the cells in this perfusion buffer was observed using the inverted light microscope that is equipped with a 20× objective lens (Olympus, LCAch N 20X PHP) and XC10 CCD camera (Olympus) ...
-
bioRxiv - Biophysics 2020Quote: ... The two galvanometer mirrors were (approximately) imaged to the back focal plane of the objective lens (Olympus, LCPlan N 20×/0.45 IR, air immersion) via a novel custom-built 1:1 magnification 4F telescope ...
-
bioRxiv - Neuroscience 2021Quote: ... f = 400 mm) focusing the light onto the rear focal plane of a high numerical aperture objective (Olympus UPlanFL N 20x, numerical aperture (NA) = 0.5 (air ...
-
bioRxiv - Neuroscience 2024Quote: ... synaptic response to ChrimsonR was evoked by a single pulse of orange light (1 ms) with full- field illumination through the 60x objective (Olympus LUMplanFL N 60x/1.00W). We found that prolonged stimulation of orange light drives ChrimsonR into the desensitized state and causes depolarization block of the pre-synaptic terminals ...
-
bioRxiv - Neuroscience 2021Quote: ... for 5 min and imaged using a fluorescent microscope (Olympus BX51). The Iba1+ area and CD68+ area was quantized by Image J software (version 1.45 J ...
-
bioRxiv - Physiology 2020Quote: ... The intestinal tracts of the larvae were imaged for 6-10 min at 22 °C using an inverted confocal laser scanning microscope (Olympus FluoView FV3000 ...
-
bioRxiv - Physiology 2020Quote: ... The intestinal tracts of the larvae were imaged for 6-10 min at 22 °C using an inverted confocal laser scanning microscope (Olympus FluoView FV3000; Olympus Corporation of the Americas Headquarters ...
-
bioRxiv - Genomics 2021Quote: ... the cells in 6-well plates or flasks were imaged directly using the Olympus IX71 inverted fluorescence microscope (Olympus Corporation).
-
Rapid body colouration change in Oryzias celebensis as a social signal for intraspecific competitionbioRxiv - Animal Behavior and Cognition 2023Quote: ... and then photos of the whole body of the test fish were taken using a digital camera (TG-6, Olympus) for individual identification by their fin shapes and pigmentation patterns of the body surface ...
-
bioRxiv - Neuroscience 2021Quote: The laser was expanded and collimated with two lenses to fill the back aperture of the microscope objective (Olympus Plan N 10x/0.25 air objective) over a dichroic mirror (Semrock) ...
-
bioRxiv - Physiology 2021Quote: ... Water was placed within a rubber O-ring of the stabilization probe to allow immersion of the microscope objective (Olympus XLPlan N 25x 1.05 NA). ECG and respiratory signals were collected while imaging z-stacks (50-100 frames ...
-
bioRxiv - Neuroscience 2020Quote: ... Omicron SOLE-6) and a detection path comprising an Olympus MVX-10 zoom macroscope with a 1× objective (Olympus MVPLAPO 1x), a filter wheel (Ludl 96A350) ...
-
bioRxiv - Molecular Biology 2020Quote: ... the correspondingly transfected AR42J cells were incubated on the coverslips that were placed on the bottoms of a 6-well plate with complete media for 48 hours before they were observed under fluorescence microscope (IX 71, Olympus, Japan). Oil immersion lens was applied for the observation of green and red bright puncta in SPINK1 overexpressing or knockdown AR42J cells stimulated with cerulein ...
-
bioRxiv - Neuroscience 2020Quote: ... Omicron SOLE-6) and a detection path comprising an Olympus MVX-10 zoom macroscope with a 1x objective (Olympus MVPLAPO 1x), a filter wheel (Ludl 96A350) ...
-
bioRxiv - Developmental Biology 2021Quote: ... sgRNAs and the targeting vector were introduced into cytoplasm and the larger male pronucleus of C57BL/6 mouse zygotes by an inverted microscope (OLYMPUS IX71) equipped with a micro-injector system (Eppendorf FemtoJet 4i) ...