Labshake search
Citations for Promega :
901 - 950 of 9071 citations for Total Carbohydrate Microplate Assay Kit since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Physiology 2022Quote: ... 2-DG uptake was measured using a Glucose Uptake-Glo Assay kit (Promega, Madison, WI).
-
bioRxiv - Microbiology 2022Quote: ... for Calu-3 cells and CellTiter-Glo 3-D Cell Viability Assay Kit (Promega, Germany) for hBAECs according to the manufacturer’s protocol ...
-
bioRxiv - Physiology 2022Quote: ... 2-Deoxyglucose-6-phosphate (2DGP) was measured using a Glucose Uptake-Glo Assay Kit (Promega) following the manufacturer’s instructions.
-
bioRxiv - Biochemistry 2023Quote: ... Lactate dehydrogenase release was detected using the CytoTox-ONE Homogenous Membrane Integrity Assay Kit (Promega), as per the manufacturer’s instructions ...
-
bioRxiv - Microbiology 2022Quote: The ATP levels were determined using a BacTiter-Glo Microbial Cell Viability Assay kit (Promega). A fresh culture of E ...
-
bioRxiv - Plant Biology 2023Quote: ... and luciferase activities were measured using a dual-luciferase reporter assay kit (Promega, Beijing China).
-
bioRxiv - Developmental Biology 2023Quote: ... and cell lysates were examined for luciferase activities with the luciferase assay system kit (Promega). The relative luciferase activities were calculated after normalization with the ß-gal activities ...
-
bioRxiv - Cell Biology 2024Quote: ... Apoptosis was measured using RealTime-Glo™ Annexin V Apoptosis and Necrosis Assay kit (Promega) following manufacturer’s instructions.
-
bioRxiv - Developmental Biology 2024Quote: ... Luciferase intensity was measured by the Luciferase Assay System kit (Cat #, E1500; Promega, Madison, WI) on Promega GloMax Explorer (Cat # ...
-
bioRxiv - Neuroscience 2024Quote: Cell viability was assayed using the CellTiter-Glo luminescent cell viability assay kit (G7570, Promega) according to the manufacturer’s instructions ...
-
bioRxiv - Microbiology 2024Quote: ... Luciferase activity was measured 8 hpi using a Nano-Glo luciferase assay kit (Promega N1120). Multicycle replication infections were performed by inoculating cells with WSN PASTN at MOI 0.01 in VGM with 0.25 μg/ml TPCK-trypsin ...
-
bioRxiv - Immunology 2024Quote: ... Cell death was determined with CytoTox 96® Non-Radioactive Cytotoxicity Assay kit (G1780, Promega).
-
bioRxiv - Genomics 2024Quote: ... Relative luciferase activity in the cell lysates was measured using a luciferase assay kit (Promega).
-
bioRxiv - Microbiology 2024Quote: ... cells were lysed with passive lysis buffer from the Dual-Luciferase Reporter Assay kit (Promega). Luciferase readings were obtained by the GloMax®-Multi Detection System.
-
bioRxiv - Molecular Biology 2024Quote: ... The glucose uptake rate was then determined using the Glucose Uptake-Glo Assay kit (Promega) according to manufacturer’s instructions ...
-
mTOR inhibition enhances delivery and activity of antisense oligonucleotides in uveal melanoma cellsbioRxiv - Cancer Biology 2021Quote: ... which was measured with a GloMax 96 Microplate Luminometer (Promega). The CellTiter-Glo assay was performed on various predefined timepoints.
-
bioRxiv - Cell Biology 2020Quote: ... Luminescence was measured using a GloMax Navigator microplate luminometer (Promega).
-
bioRxiv - Molecular Biology 2022Quote: ... Plates were imaged using a GloMax Discover Microplate Reader (Promega). Analysis and statistical test were performed using Microsoft Excel.
-
bioRxiv - Cancer Biology 2021Quote: ... Luminescence was measured on a GloMax 96 Microplate Luminometer (Promega). DC50 was calculated using lower concentrations (showing sigmoidal behaviour ...
-
bioRxiv - Cancer Biology 2020Quote: ... or a GloMax® Explorer Multimode Microplate Reader 3500 (Promega) with a BrillianStar-LT assay system (Toyo-b-net ...
-
bioRxiv - Plant Biology 2021Quote: ... Fluorescence was quantified using a Glomax Discover microplate reader (Promega) using an excitation wavelength of 475 nm and emission was captured at 500-550 nm.
-
bioRxiv - Molecular Biology 2020Quote: ... Measurements were made using a GloMax 96 Microplate Luminometer (Promega) with a 2-s delay and a 10-s measurement ...
-
bioRxiv - Cancer Biology 2020Quote: ... and quantified with GloMax microplate reader (Promega GmbH, Walldorf, Germany). Samples were loaded in a polyacrylamide gel and separated by SDS-PAGE ...
-
bioRxiv - Microbiology 2022Quote: ... Growth was monitored with a microplate reader (Glomax Discover, Promega). Experiments were performed at least three times.
-
bioRxiv - Microbiology 2022Quote: ... in a GloMax® Navigator Microplate Luminometer (Promega, Madrid, Spain).
-
bioRxiv - Cancer Biology 2021Quote: ... which was measured with a GloMax 96 Microplate Luminometer (Promega).
-
bioRxiv - Biochemistry 2020Quote: ... followed by measurement of RLU using GloMax Microplate Luminometer (Promega). All experiments were repeated at least twice ...
-
bioRxiv - Genetics 2020Quote: ... We measure the luminescence using the GloMax Microplate reader (Promega). To determine cell growth curve ...
-
bioRxiv - Microbiology 2021Quote: ... Luminescence was measured on GloMax® Discover Microplate Reader (Promega).
-
bioRxiv - Molecular Biology 2021Quote: ... on a GloMax® Discover Multimode Microplate Reader (Promega, USA). The results are represented as means and standard deviation (SD ...
-
bioRxiv - Genetics 2020Quote: ... Measurements were performed on a GloMax 96-microplate luminometer (Promega).
-
bioRxiv - Plant Biology 2023Quote: ... The analysis was performed on GloMax 96 Microplate Luminometer (Promega), and the F-Luc/R-Luc ratio was calculated for all samples and technical replicates.
-
bioRxiv - Microbiology 2022Quote: ... luminescence was detected on a GloMax Navigator microplate reader (Promega).
-
bioRxiv - Cancer Biology 2022Quote: ... Luminescence was measured using the GloMax 96 Microplate Luminometer (Promega). In parallel ...
-
bioRxiv - Plant Biology 2023Quote: ... or in a GloMax 96 Microplate Luminometer (Promega, other figures). Statistical differences were analysed by one-way ANOVA followed by Tukey’s HSD post hoc test ...
-
bioRxiv - Immunology 2023Quote: ... Luminance (ALU) measured in a GloMax Navigator Microplate Luminometer (Promega) was normalized to microgram lysate protein.
-
bioRxiv - Plant Biology 2023Quote: ... Bioluminescence was measured using GloMax Explorer multimode microplate reader (Promega).
-
bioRxiv - Cell Biology 2022Quote: ... and fluorescence measured using multi-mode microplate reader GlowMax (Promega) using excitation and emission wavelengths of 570 nm and 600 nm ...
-
bioRxiv - Developmental Biology 2022Quote: ... with absorbance read using a Glomax Explorer Microplate reader (Promega) at 560nm and normalized for amount of total protein across all samples ...
-
bioRxiv - Genomics 2022Quote: ... Plates were read on a GloMax 96 Microplate Luminometer (Promega) using the standard CellTiterGlo program.
-
bioRxiv - Genomics 2022Quote: ... Luminescence was measured on a GloMax 96 Microplate Luminometer (Promega) using a standard Dual Reporter Assay program ...
-
bioRxiv - Cancer Biology 2022Quote: ... Luminescence was measured on a GloMax 96 Microplate Luminometer (Promega) using a standard Dual Reporter Assay program ...
-
bioRxiv - Microbiology 2024Quote: Luciferase activity was measured with GloMax Discover Microplate Reader (Promega) using a Nano-Glo HiBiT Lytic assay system (Promega ...
-
bioRxiv - Microbiology 2024Quote: ... and run on a GloMax® Discover Microplate Reader (Promega). Libraries were pooled together in equal nanograms and SPRI size selected at 0.6X bead volume using Illumina Sample purification beads with final elution in 32 µl ...
-
bioRxiv - Microbiology 2024Quote: ... using a spectrophotometer and a Glomax Discover microplate reader (Promega) respectively as described in (Derbise et al. ...
-
bioRxiv - Systems Biology 2024Quote: ... followed by measurement using GloMax® Discover Microplate Reader (Promega).
-
bioRxiv - Bioengineering 2024Quote: ... Luminescence was detected on GloMax Discover Microplate Reader (GM3000, Promega).
-
bioRxiv - Synthetic Biology 2024Quote: ... The bioluminescence was recorded on a microplate reader (GloMax, Promega). The pseudovirus neutralizing antibody titers at 50% inhibition (pVNT50 ...
-
bioRxiv - Molecular Biology 2020Quote: ... Two micrograms of total RNA were used for cDNA synthesis with a reverse transcription kit (Promega). Quantitative real-time PCR was performed using the SYBR premix kit (Promega) ...
-
bioRxiv - Microbiology 2021Quote: ... Total RNAs were isolated from the pellet using the Maxwell 16 LEV miRNA Tissue Kit (Promega) according to the manufacturer’s instructions and an extra TURBO DNase (Invitrogen ...