Labshake search
Citations for New Objective :
1 - 50 of 172 citations for Recombinant Human Chemokine C X C Motif Ligand 10 since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2021Quote: ... using a 300 nL/min flow rate of mobile phase A (0.1% formic acid) and separated in a C18 PicoFrit PepMap (10 cm x 10 μm x 75 μm; 135 Å pore, New Objective), over 105 minutes using a linear gradient 2-30 % followed by 20 min of 30-45% of mobile phase B (100% ACN ...
-
bioRxiv - Immunology 2022Quote: ... The Ultimate 3000’s column oven was set to 50°C and for proper ionization a fused silica PicoTip emitter (10 μm inner diameter, New Objective, Littleton, MA, US) was connected to the μPAC outlet union and a grounded connection was provided to this union ...
-
Borrelia PeptideAtlas: A proteome resource of common Borrelia burgdorferi isolates for Lyme researchbioRxiv - Biochemistry 2023Quote: ... Analytical column (PICOCHIP: 105 cm, 1.9 µm, REPROSIL Pur C-18-AQ, 120 Å, New Objective, USA) with a flow rate of 300 nL/min was used for the separation of the peptides with a linear gradient of 5–35% buffer-B (90% acetonitrile in 0.1% FA ...
-
bioRxiv - Cancer Biology 2019Quote: Purified peptide mixtures were loaded onto a 10 cm x 75 μm PicoFrit capillary column (New Objective) packed with Magic C18 AQ reversed-phase resin (Michrom Bioresources ...
-
bioRxiv - Microbiology 2023Quote: ... peptides separation was performed by C-18 reversed phase chromatography (capillary columns, PicoFrit, 30 cm × 150 µm ID, New Objective packed with ReproSil-Pur 120 C18-AQ ...
-
bioRxiv - Microbiology 2023Quote: ... and separated at 40°C on a PicoTip emitter (noncoated, 15 cm, 75 μm ID, 8 μm tip, New Objective) that was in-house packed with Reprosil-Pur 120 C18-AQ material (1.9 μm ...
-
bioRxiv - Biochemistry 2022Quote: ... peptides were separated at 40 °C on a PicoTip emitter (noncoated, 15 cm, 75 μm ID, 8 μm tip, New Objective) that was in house packed with Reprosil-Pur 120 C18-AQ material (1.9 μm ...
-
bioRxiv - Biochemistry 2023Quote: ... and were then separated at 40 °C on a PicoTip emitter (noncoated, 15 cm, 75 μm ID, 8 μm tip, New Objective) that was in-house packed with Reprosil-Pur 120C18-AQ material (1.9 μm ...
-
bioRxiv - Biochemistry 2021Quote: ... Samples were injected and chromatographically separated on a fused silica microcapillary column (360 μm OD X 75 μm ID) with a 10 μm electrospray emitter tip (New Objective) packed to ∼25 cm with ReproSil-Pur 1.9 μm C18-AQ beads (Dr ...
-
bioRxiv - Biochemistry 2019Quote: ... Reverse-phase chromatography of peptides was performed using a C-18 column (IntegraFrit, 360 μm OD × 75 μm ID; New Objective USA). Peptides were separated by a 70 min linear gradient ...
-
bioRxiv - Developmental Biology 2023Quote: ... The analytical column was connected to a Pico-Tip Emitter (New Objective; 360 μm OD x 20 μm ID; 10 μm tip). The LC system was coupled to a QExactive plus (Thermo ...
-
bioRxiv - Molecular Biology 2020Quote: ... Reverse-phase chromatography was performed at 50 °C over a 25 cm IntegraFrit column (IF360–75-50-N-5, New Objective, Woburn, MA) packed in-house with 1.9 μm ReproSil-Pur C18-AQ (Dr ...
-
bioRxiv - Neuroscience 2022Quote: ... Peptides were then separated on a 10 mm PicoTip™ fused silica emitter 75 μm x 16 cm (New Objective Inc., Woburn, USA), packed in-house with Peprosil C18-AQ resin 3 μm (Dr ...
-
bioRxiv - Molecular Biology 2022Quote: ... Sonation) to heat up the nano column (PicoFrit, 100 µm x 250 mm x 15 µm tip, New Objective) for peptide separation ...
-
bioRxiv - Cancer Biology 2022Quote: ... Sonation) to heat up the nano column (PicoFrit, 100 μm x 250 mm x 15 μm tip, New Objective) for peptide separation ...
-
bioRxiv - Immunology 2023Quote: ... coupled to a QExactive plus (Thermo) mass spectrometer via a Nanospray Flex source (Thermo) using a Pico-Tip Emitter (New Objective; 360 µm OD x 20 µm ID; 10 µm tip). The peptides were first trapped on a C18 PepMap 100 µ-Precolumn (300 µm x 5 mm ...
-
bioRxiv - Cancer Biology 2019Quote: ... 75 μm x 35 cm length (New Objective, Woburn, Massachusetts, US), packed with ReproSil-Pur 120A C18-AQ 3 μm (Dr ...
-
bioRxiv - Biochemistry 2022Quote: ... The 75 um x 15 cm column (PicoFrit Self pack emitter, New Objective) was in house packed with ReproSIL-Pur-120-C18-AQ (3 μm ...
-
bioRxiv - Cell Biology 2020Quote: ... peptides were loaded onto 75 µm x 15 cm fused silica capillaries (New Objective) packed with C18AQ resin (Reprosil-Pur 120 ...
-
bioRxiv - Cell Biology 2023Quote: ... Peptides were separated using a reverse phase column (75µm ID x 400mm New Objective, in-house packed with ReproSil Gold 120 C18 ...
-
bioRxiv - Cell Biology 2023Quote: ... Peptides were separated using a reverse phase column (75µm ID x 400mm New Objective, in-house packed with ReproSil Gold 120 C18 ...
-
bioRxiv - Cancer Biology 2023Quote: ... Peptides were separated over a 100 µm X 250 mm PicoFrit column (New Objective) packed with 1.7 µm BEH-130 C18 (Waters ...
-
bioRxiv - Neuroscience 2019Quote: ... Peptides were loaded on capillary columns (PicoFrit, 30 cm x 150 µm ID, New Objective) self-packed with ReproSil-Pur 120 C18-AQ ...
-
bioRxiv - Biochemistry 2020Quote: ... Peptides were loaded on capillary columns (PicoFrit, 30 cm x 150 μm ID, New Objective) self-packed with ReproSil-Pur 120 C18-AQ ...
-
bioRxiv - Cell Biology 2022Quote: Samples were injected onto a column (360 µm O.D. x 75 µm I.D., New Objective) packed with 25cm of 1.8 µm Reprosil C18 particles with (Dr ...
-
bioRxiv - Microbiology 2020Quote: ... Peptides were loaded on capillary columns (PicoFrit, 30 cm x 150 μm ID, New Objective) self-packed with ReproSil-Pur 120 C18-AQ ...
-
bioRxiv - Microbiology 2019Quote: ... 10 µm tip (New Objective) and an applied spray voltage of 2.4 kV ...
-
bioRxiv - Microbiology 2019Quote: ... 10 µm tip (New Objective). The mass spectrometer was operated in positive ion mode with a spray voltage of 2.3 kV and capillary temperature of 320°C ...
-
bioRxiv - Biochemistry 2021Quote: ... 10 μm emitter (New Objective)) ...
-
bioRxiv - Biochemistry 2020Quote: ... 10 μm tip (New Objective) and a spray voltage of 2.2 kV was applied ...
-
bioRxiv - Biochemistry 2020Quote: ... 10 μm tip (New Objective) and a spray voltage of 2.2 kV was applied ...
-
bioRxiv - Systems Biology 2021Quote: ... 10 µm tip (New Objective) and an applied spray voltage of 2.2 kV ...
-
bioRxiv - Systems Biology 2021Quote: ... 10-μm tip (New Objective) heated at 300 °C ...
-
bioRxiv - Systems Biology 2021Quote: ... 10 μm tip (New Objective), and a spray voltage of 2.2 kV was applied ...
-
bioRxiv - Neuroscience 2020Quote: ... 10 lm tip (New Objective). MS spectra with a mass range of 375–1.200 m/z were acquired in profile mode using a resolution of 70.000 [maximum fill time of 250ms or a maximum of 3e6 ions (automatic gain control ...
-
bioRxiv - Systems Biology 2020Quote: ... 10 μm tip (New Objective) and an applied spray voltage of 2.3 kV ...
-
bioRxiv - Cancer Biology 2022Quote: ... 10 µm emitter (New Objective)) ...
-
bioRxiv - Molecular Biology 2019Quote: ... 10 μm tip (New Objective) and a spray voltage of 2 kV.
-
bioRxiv - Cancer Biology 2020Quote: ... 10 lm tip (New Objective). MS spectra with a mass range of 375–1.200 m/z were acquired in profile mode using a resolution of 70.000 [maximum fill time of 250 ms or a maximum of 3e6 ions (automatic gain control ...
-
bioRxiv - Genomics 2021Quote: ... 10 μm tip (New Objective) and a spray voltage of 2.2kV was applied ...
-
bioRxiv - Genomics 2021Quote: ... 10 μm tip (New Objective) and a spray voltage of 2.2kV was applied ...
-
bioRxiv - Biochemistry 2021Quote: ... 10 μm tip (New Objective) and an applied spray voltage of 2.4 kV ...
-
bioRxiv - Cell Biology 2021Quote: ... 10 μm tip (New Objective) and an applied spray voltage of 2.1 kV ...
-
bioRxiv - Biochemistry 2020Quote: ... 10 µm tip (New Objective). The MS was operated in positive mode and a spray voltage of 2.4 kV was applied for ionization with an ion transfer tube temperature of 275 °C ...
-
bioRxiv - Immunology 2020Quote: ... 10 μm emitter (New Objective)) ...
-
bioRxiv - Cancer Biology 2020Quote: ... 10 µm tip (New Objective). The MS was operated in positive mode and a spray voltage of 2.4 kV was applied for ionization with an ion transfer tube temperature of 275 °C ...
-
bioRxiv - Cell Biology 2021Quote: ... 10 μm tip (New Objective). The mass spectrometer was operated in positive ion mode ...
-
bioRxiv - Genomics 2022Quote: ... 10 µm tip (New Objective) and a spray voltage of 2.2 kV was applied ...
-
bioRxiv - Systems Biology 2023Quote: ... 10-μm tip (New Objective) heated at 300 °C ...
-
bioRxiv - Biophysics 2023Quote: ... 10 μm tip (New Objective). A spray voltage of 2.3 kV was applied and the mass spectrometer was operated in positive ion mode ...