Labshake search
Citations for New Objective :
1 - 50 of 60 citations for Mouse Fragile X Mental Retardation 1 Neighbor Protein FMR1NB ELISA Kit since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2021Quote: ... with peptides generated from roughly 500ng of proteins injected for each analysis onto either 75 micron x 25cm packed emitter columns (New Objective) or 75 micron x 50 cm C18 Acclaim Pepmap columns (Thermo Scientific) ...
-
bioRxiv - Molecular Biology 2022Quote: ... Sonation) to heat up the nano column (PicoFrit, 100 µm x 250 mm x 15 µm tip, New Objective) for peptide separation ...
-
bioRxiv - Cancer Biology 2022Quote: ... Sonation) to heat up the nano column (PicoFrit, 100 μm x 250 mm x 15 μm tip, New Objective) for peptide separation ...
-
bioRxiv - Biochemistry 2023Quote: ... 1 μg of peptide was loaded onto a 75 μm inner diameter x 360 μm outer diameter column (New Objective) packed in-house 1 to 30 cm with 1.7 micron BEH C18 particles (Waters Corp) ...
-
bioRxiv - Microbiology 2022Quote: ... and subsequently separated on an in-house packed PicoFrit column (75 µm x 200 mm, 15 µm, +/-1 µm tip, New Objective) with C18 phase (ReproSil-Pur C18-AQ ...
-
bioRxiv - Biochemistry 2021Quote: ... using a 300 nL/min flow rate of mobile phase A (0.1% formic acid) and separated in a C18 PicoFrit PepMap (10 cm x 10 μm x 75 μm; 135 Å pore, New Objective), over 105 minutes using a linear gradient 2-30 % followed by 20 min of 30-45% of mobile phase B (100% ACN ...
-
bioRxiv - Cancer Biology 2019Quote: ... 75 μm x 35 cm length (New Objective, Woburn, Massachusetts, US), packed with ReproSil-Pur 120A C18-AQ 3 μm (Dr ...
-
bioRxiv - Biochemistry 2022Quote: ... The 75 um x 15 cm column (PicoFrit Self pack emitter, New Objective) was in house packed with ReproSIL-Pur-120-C18-AQ (3 μm ...
-
bioRxiv - Cell Biology 2020Quote: ... peptides were loaded onto 75 µm x 15 cm fused silica capillaries (New Objective) packed with C18AQ resin (Reprosil-Pur 120 ...
-
bioRxiv - Cell Biology 2023Quote: ... Peptides were separated using a reverse phase column (75µm ID x 400mm New Objective, in-house packed with ReproSil Gold 120 C18 ...
-
bioRxiv - Cell Biology 2023Quote: ... Peptides were separated using a reverse phase column (75µm ID x 400mm New Objective, in-house packed with ReproSil Gold 120 C18 ...
-
bioRxiv - Cancer Biology 2023Quote: ... Peptides were separated over a 100 µm X 250 mm PicoFrit column (New Objective) packed with 1.7 µm BEH-130 C18 (Waters ...
-
bioRxiv - Neuroscience 2019Quote: ... Peptides were loaded on capillary columns (PicoFrit, 30 cm x 150 µm ID, New Objective) self-packed with ReproSil-Pur 120 C18-AQ ...
-
bioRxiv - Biochemistry 2020Quote: ... Peptides were loaded on capillary columns (PicoFrit, 30 cm x 150 μm ID, New Objective) self-packed with ReproSil-Pur 120 C18-AQ ...
-
bioRxiv - Cell Biology 2022Quote: Samples were injected onto a column (360 µm O.D. x 75 µm I.D., New Objective) packed with 25cm of 1.8 µm Reprosil C18 particles with (Dr ...
-
bioRxiv - Microbiology 2020Quote: ... Peptides were loaded on capillary columns (PicoFrit, 30 cm x 150 μm ID, New Objective) self-packed with ReproSil-Pur 120 C18-AQ ...
-
bioRxiv - Cell Biology 2022Quote: ... Peptides were separated using a reverse phase column (75 µm ID x 400 mm New Objective, in-house packed with ReproSil Gold 120 C18 ...
-
bioRxiv - Cell Biology 2022Quote: ... Peptides were separated using a reverse phase column (75 µm ID x 400 mm New Objective, in-house packed with ReproSil Gold 120 C18 ...
-
bioRxiv - Cell Biology 2023Quote: ... Peptides were separated using a reverse phase column (75 μm ID x 400 mm New Objective, in-house packed with ReproSil Gold 120 C18 ...
-
bioRxiv - Developmental Biology 2020Quote: ... we used PicoFrit fused silica capillary columns (15 cm x 75 µm i.d; New Objective, Woburn, MA) with C-18 reverse-phase material and high pressure packing cells (Jupiter 5 µm particles ...
-
bioRxiv - Developmental Biology 2022Quote: ... column packed in-house in Pico-Frit (100 μm X 30 cm) capillaries (New Objective, Woburn, MA). Analyses of peptide digests were carried out on an Orbitrap Q Exactive HF-X instrument (Thermo Fisher Scientific ...
-
bioRxiv - Cancer Biology 2019Quote: Purified peptide mixtures were loaded onto a 10 cm x 75 μm PicoFrit capillary column (New Objective) packed with Magic C18 AQ reversed-phase resin (Michrom Bioresources ...
-
bioRxiv - Microbiology 2022Quote: ... Peptides were directly injected onto an analytical column (360 µm O.D. x 75 µm I.D.) with an integrated emitter (New Objective) that was packed with 25 cm of ReproSil Pur C18 AQ 1.9 µm particles (Dr ...
-
bioRxiv - Cell Biology 2021Quote: ... The peptides were separated with a 2-30% acetonitrile gradient in 0.1% formic acid using a PicoFrit analytical column (20 cm x 75 nm, particle size from 5 μm, New Objective) at a flow rate of 300 nL/min over 173 min ...
-
bioRxiv - Cell Biology 2022Quote: ... Peptides were separated by a 2–90% acetonitrile gradient in 0.1% formic acid using PicoFrit analytical column (20 cm x ID75 μm, 5 μm particle size, New Objective) at a flow rate of 300 nL·min−1 over 212 min ...
-
bioRxiv - Biochemistry 2020Quote: LC separation of peptides originating from HEK293 cell membranes was performed via selfpacked C18 columns (PicoFrits, 75 μm x 50 cm, 15 μm tip, New Objective, self-packed with ReproSil-Pur 120 C18-AQ ...
-
bioRxiv - Biochemistry 2020Quote: ... for 3 min and separated on a C18 analytical column (picofrit 75 μm ID x 150 mm, 3 μm, New Objective) using a linear gradient of 2 % to 45 % solvent B (80% acetonitrile ...
-
bioRxiv - Molecular Biology 2022Quote: ... and an in-house packed (3 µm C18 particles, Dr Maisch) analytical 50 cm x 75 µm ID emitter-column (New Objective). Peptides were eluted at 250 nl/min with a 5-35% B 120 min gradient (buffer B ...
-
bioRxiv - Biochemistry 2021Quote: ... Samples were injected and chromatographically separated on a fused silica microcapillary column (360 μm OD X 75 μm ID) with a 10 μm electrospray emitter tip (New Objective) packed to ∼25 cm with ReproSil-Pur 1.9 μm C18-AQ beads (Dr ...
-
bioRxiv - Immunology 2021Quote: ... Peptides were fractionated by reverse-phase HPLC on a 75 μm x 15 cm PicoFrit column with a 15 μm emitter (New Objective) in-house packed with Magic C18AQ (Michrom BioResources ...
-
bioRxiv - Cell Biology 2021Quote: ... trapped the peptides prior to separation on PicoChip Column: 75um ID x 15um tip packed with 105mm 3um Reprosil-PUR C18-AQ 120A (New Objective). Peptides were eluted with an acetonitrile gradient ...
-
bioRxiv - Synthetic Biology 2023Quote: ... and an in-house packed (3 μm C18 particles, Dr Maisch) analytical 50 cm x 75 μm emitter-column (New Objective). Columns were operated at 45°C ...
-
bioRxiv - Microbiology 2024Quote: ... Peptides were loaded on a reverse-phase column (150 mm x 0.075 mm inner diameter, New Objective, New Objective, Woburn, MA), packed in-house with Reprosil-Pur C18-AQ 3 mm particles (Dr ...
-
bioRxiv - Microbiology 2024Quote: ... Peptides were loaded on a reverse-phase column (150 mm x 0.075 mm inner diameter, New Objective, New Objective, Woburn, MA), packed in-house with Reprosil-Pur C18-AQ 3 mm particles (Dr ...
-
bioRxiv - Genetics 2021Quote: ... Online LC separation was carried out using a 75 µm x 25 cm fused silica IntregraFrit capillary column (New Objective, Woburn, MA) packed in-house with 1.9 µm Reprosil-Pur C18 AQ reverse-phase resin (Dr ...
-
bioRxiv - Genetics 2021Quote: ... Online LC separation was carried out using a 75 µm x 25 cm fused silica PicoTip capillary column (New Objective, Woburn, MA) packed in-house with 1.9 µm Reprosil-Pur C18 AQ reverse-phase resin (Dr ...
-
bioRxiv - Systems Biology 2020Quote: ... Peptide mixtures were separated on a self-packed C18 (1.9 μm, Dr. Maisch, Germany) fused silica column (25 cm x 75 μM internal diameter; New Objective, Woburn, MA) by a NanoAcquity UHPLC (Waters ...
-
bioRxiv - Cell Biology 2021Quote: ... 2 μl of the reconstituted peptides were separated on a self-packed C18 (1.9 μm Dr. Maisch, Germany) fused silica column (25 cm x 75 μM internal diameter; New Objective, Woburn, MA) by a Dionex Ultimate 3000 RSLCNano ...
-
bioRxiv - Cell Biology 2021Quote: ... Peptide mixtures were separated on a self-packed C18 (1.9 um Dr. Maisch, Germany) fused silica column (25 cm x 75 μM internal diameter; New Objective, Woburn, MA) by a NanoAcquity UHPLC (Waters ...
-
bioRxiv - Developmental Biology 2023Quote: ... The analytical column was connected to a Pico-Tip Emitter (New Objective; 360 μm OD x 20 μm ID; 10 μm tip). The LC system was coupled to a QExactive plus (Thermo ...
-
bioRxiv - Systems Biology 2020Quote: ... coupled to a C18 cartridge trap-column in a backflush configuration and an analytical 50 cm x 75 μm emitter-column (New Objective, MA, USA) in-house packed with 3 μm C18 particles (Dr ...
-
bioRxiv - Neuroscience 2022Quote: ... Peptides were then separated on a 10 mm PicoTip™ fused silica emitter 75 μm x 16 cm (New Objective Inc., Woburn, USA), packed in-house with Peprosil C18-AQ resin 3 μm (Dr ...
-
bioRxiv - Biochemistry 2022Quote: ... The analytical column was a 75 μm x 10.5 cm PicoChip column packed with 3 μm ReproSil-Pur beads (New Objective, Inc. Woburn, MA) at 300 nL/min ...
-
bioRxiv - Cell Biology 2022Quote: ... The analytical column was a 75 um x 10.5 cm PicoChip column packed with 3 um ReproSil-Pur® beads (New Objective, Inc. Woburn, MA). The flow rate was kept at 300nL/min ...
-
bioRxiv - Neuroscience 2023Quote: ... The analytical column was a 75 µm x 10.5 cm PicoChip column packed with 3 µm ReproSil-Pur® beads (New Objective, Inc. Woburn, MA). The flow rate was kept at 300 nL/min ...
-
bioRxiv - Neuroscience 2023Quote: ... The analytical column was a 75 µm x 10.5 cm PicoChip column packed with 3 µm ReproSil-Pur® beads (New Objective, Inc. Woburn, MA). The flow rate was kept at 300 nL/min ...
-
bioRxiv - Immunology 2023Quote: ... coupled to a QExactive plus (Thermo) mass spectrometer via a Nanospray Flex source (Thermo) using a Pico-Tip Emitter (New Objective; 360 µm OD x 20 µm ID; 10 µm tip). The peptides were first trapped on a C18 PepMap 100 µ-Precolumn (300 µm x 5 mm ...
-
bioRxiv - Plant Biology 2023Quote: Root protein samples were injected (0.5 µg protein) into an online nanoflow (300 nL / min) capillary column (Picofrit with 10μm tip opening / 75μm diameter, New Objective, PF360–75-10-N-5) packed in-house with 15 cm C18 silica material (3 µm ...
-
Domain-specific quantification of prion protein in cerebrospinal fluid by targeted mass spectrometrybioRxiv - Neuroscience 2019Quote: ... Samples were injected (1 to 2 µg) onto a 75 um ID PicoFrit column (New Objective) packed to 20 cm with Reprosil-Pur C18 AQ 1.9 um media (Dr ...
-
bioRxiv - Molecular Biology 2020Quote: ... Eluting peptides were sprayed into the mass spectrometer through 1 µm emitter tip (New Objective, Woburn, MA) at 2.4 kV ...