Labshake search
Citations for Chroma Technology :
301 - 350 of 623 citations since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biophysics 2022Quote: ... Emission light was collected by the same objective and separated from the excitation light by a dichroic filter (740DCSPXR, Chroma Technology, Bellows Falls, VT), then split into red and green detection channels by a low-pass dichroic (FF580-FDi01 ...
-
bioRxiv - Immunology 2022Quote: ... A 4 band multi-color TIRF dichroic located in the microscope separated the excitation and emission light for imaging (Chroma Technology). Images of CAR or TCR were collected by imaging CAR-mEmerald (or Alexa Fluor 488-labeled TCRs ...
-
bioRxiv - Neuroscience 2022Quote: Blue-light-emitting diodes (Luxeon K2, 473 nm, Quadica Developments Inc, Lethbridge, Alberta) augmented with band-pass filters (Chroma Technology Corp, 467–499 nm) were used to excite the Butterfly indicator ...
-
bioRxiv - Neuroscience 2022Quote: Blue-light-emitting diodes (Luxeon K2, 473 nm, Quadica Developments Inc, Lethbridge, Alberta) augmented with band-pass filters (Chroma Technology Corp, 467–499 nm) were used to excite iGluSnFR indicators ...
-
bioRxiv - Biophysics 2022Quote: ... Additional optical parameters included excitation/emission filters (Chroma Technology) at 480/40 and 535/50 for calcein and DiYO and 560/40 and 630/75 for Texas Red and an Arduino controlled Spectra-X LED Light Engine (Lumencor ...
-
bioRxiv - Biophysics 2022Quote: ... The fluorescence emission was passed through a quad band emission filter (ZET405/488/561/640m, Chroma Technology Corp, Vermont, USA). An electron-multiplying charge-coupled device (EMCCD ...
-
bioRxiv - Biophysics 2022Quote: ... A quad band dichroic (ZT405/488/561/640rpc, Chroma Technology Corp, Vermont, USA) was used to direct the laser to the sample and allow the fluorescence emission to pass through ...
-
bioRxiv - Plant Biology 2022Quote: ... Solid-state lasers (Obis) were used with standard emission filters (Chroma Technology). Excitation 445 ...
-
bioRxiv - Plant Biology 2022Quote: ... Solid-state lasers (Obis from 40-100mW) and standard emission filters (Chroma Technology) were used ...
-
bioRxiv - Immunology 2022Quote: ... Widefield QD605-strepavidin images were collected using a 405/10 nm excitation filter (Chroma Technology) located in the DG4 light source ...
-
bioRxiv - Immunology 2022Quote: ... IRM images were acquired using a 635/20 nm excitation filter (Chroma Technology) positioned in the DG4 light source ...
-
bioRxiv - Cancer Biology 2022Quote: ... Fluorescent images were taken with dsRed2 filter cube from Chroma Technology (ex/em: 545/30, 620/60) using a 10x objective ...
-
bioRxiv - Cell Biology 2022Quote: ● Dichoric mirror (for splitting between 647 and 750 channel): T760LPXR-UF2 (Chroma Technology Corp.)
-
bioRxiv - Molecular Biology 2022Quote: ... RD-TR (Ex555/28; Em 617/73) and DAPI (Ex360/40; Em 457/50) of the 86000 Sedat Quadruple Filter Set (Chroma Technology Corp, Bellows Falls, VT). Z-stacks were acquired with the thickness interval of 10 mm each ...
-
bioRxiv - Neuroscience 2022Quote: ... The laser beam was coupled through a 620/60nm excitation filter (Chroma technology corp.) and a 650nm dichroic mirror (Chroma technology corp.) ...
-
bioRxiv - Neuroscience 2022Quote: ... and SomArchon near-infrared emission was filtered with a 706/95nm filter (Chroma technology corp.). The fluorescence of GFP or BFP fused to SomArchon was used to localize SomArchon expressing cells during each recording ...
-
bioRxiv - Neuroscience 2022Quote: ... 560 DXCR dichroic mirrors and 525/50 and 607/70 emission filters (Chroma Technology) were used to separate green and red fluorescence ...
-
bioRxiv - Neuroscience 2022Quote: ... a long-pass dichroic beam splitter (700nm; Chroma Technology) was used to split the emission light on two cameras (ORCA-fusion sCMOS camera (Hamamatsu)) ...
-
bioRxiv - Neuroscience 2022Quote: ... filtered by emission filters (525/70 and 610/75 nm; Chroma Technology) and measured by 2 independent photomultiplier tubes (Hamamatsu R3896) ...
-
bioRxiv - Developmental Biology 2022Quote: ... and with a single-mode fiber laser (wavelength of 1064Lnm; YLR-5-1064-LP-SF, IPG Photonics) and filter set (ZT1064rdc-sp, Chroma Technology, and SIX870, Asahi). A long-path filter was inserted before a halogen lamp (LV0630 ...
-
bioRxiv - Developmental Biology 2022Quote: ... Fluorescence light was spectrally filtered with an emission filter (Chroma Technology, ET600/50m and ET575lp ...
-
bioRxiv - Developmental Biology 2022Quote: ... The laser beam was passed through clean-up filters (Chroma Technology, ZET561/10, ZET642/20x) and coupled into the microscope objective using a beam splitter (Chroma Technology ...
-
bioRxiv - Developmental Biology 2022Quote: ... and coupled into the microscope objective using a beam splitter (Chroma Technology, ZT561rdc, ZT647rdc). Fluorescence light was spectrally filtered with an emission filter (Chroma Technology ...
-
bioRxiv - Cell Biology 2022Quote: The NLS-AKAR and H188 sensors sensor were excited at 440nm and fluorescence was collected using emission filters 470/30nm and 535/30nm with a 69008bs dichroic (Chroma Technology Corp.). The H208 and NLS-H208 sensors were excited at 500nm with emission filters 510/20 and 620/52 and two dichroic beam splitters ...
-
bioRxiv - Cell Biology 2022Quote: ... Excitation (x) and emission (m) filters (ET type; Chroma Technology) were used with an FF444/521/608-Di01 dichroic (Semrock ...
-
bioRxiv - Cell Biology 2022Quote: ... and 647 (Chroma Technology Corp.), a CoolSNAP HQ2 camera (Roper Scientific) ...
-
bioRxiv - Biophysics 2022Quote: ... Alexa Fluor 546 and Alexa Fluor 647 detection (Chroma Technology 49002, 49004 and 49006, respectively). Minimal crosstalk between fluorescence channels was observed ...
-
bioRxiv - Biochemistry 2022Quote: ... A dichroic mirror (560DRLP) and bandpass emission filters (500-550nm for Alexa 488/GFP and 607-683 nm for Atto 565/mCherry, (Chroma Technology, VT) were used to separate the excitation light coming from the fluorescence emission ...
-
bioRxiv - Molecular Biology 2022Quote: ... reflected by a multi-bandpass optical filter (69013m, Chroma Technology Corp, Bellows Falls, VT, USA), and focused by an achromatic doublet lens (AC508-300-A ...
-
bioRxiv - Biophysics 2022Quote: ... Fluorescent light was spectrally filtered with emission filters (535/40m, 610/75, and 665LP, Chroma Technology) and imaged on a sCMOS camera (Zyla 4.2 ...
-
bioRxiv - Microbiology 2022Quote: ... ET520/60 for the green and ET605/70 for the red channel (Chroma Technology, Bellow Falls,VT). Fluorescence signal was collected to GaAsP photomultiplier tubes (PMT ...
-
bioRxiv - Microbiology 2022Quote: ... separated using a dichroic mirror (700dcxru, Chroma Technology) before the two-channel detector unit ...
-
bioRxiv - Molecular Biology 2022Quote: ... N.J.) with filters (set 41018 for GFP and set 51006 Texas Red filter for fluorescein isothiocyanate) from Chroma Technology (Brattleboro, Vermont, USA). Strains harboring pCUP1-GFP-STE5 (pSKM21 ...
-
bioRxiv - Neuroscience 2022Quote: ... The fluorescence signal was captured with images at 1 fps through 610/60 nm bandpass filters (Chroma Technology corp., Bellows Falls, VT, USA) using an inverted microscope (IX-71 ...
-
bioRxiv - Neuroscience 2022Quote: ... Both laser beams were bounced into a dichroic filter cube designed for 473 and 405 nm excitation as well as for 510 nm emission (Chroma Technology Corp., Bellow Falls, VT). The two excitation wavelengths were focused through a 4x fluorite objective (Olympus ...
-
bioRxiv - Neuroscience 2022Quote: ... The microscope was equipped with a primary dichroic mirror at 695 nm and green and red fluorescence was split and filtered using a secondary dichroic at 560 nm and two bandpass emission filters: 525-40 nm and 605-70 nm (Chroma Technologies).
-
bioRxiv - Neuroscience 2022Quote: Larval eyes and adult eyecups were stimulated with nine wavelengths ranging from 330 nm to 650 nm (20-nm half-width interference filters, 40-nm increments, Chroma Technology). Seven intensities were presented at each wavelength (UV compliant neutral density filters ...
-
bioRxiv - Molecular Biology 2022Quote: ... and a triple-band filter from Chroma Technology Corp (described in (Teuscher and Ewald ...
-
bioRxiv - Biophysics 2022Quote: ... Emission light was filtered using a long-pass filter (ET5701p, Chroma Technology, VT, USA), and image sequences were collected using an on-chip multiplication gain CCD camera (model 512B ...
-
bioRxiv - Bioengineering 2022Quote: ... only PMT1 (Hamamatsu Photonics H7422PA-40) with a 680 nm shortpass filter (Em1, Chroma Technology ET680sp-2p8) was used for detection ...
-
bioRxiv - Cell Biology 2022Quote: ... and rhodamine (Chroma Technology, Bellows Falls, VT), and a Zeiss 63× Plan Apochromat oil lens (NA 1.4) ...
-
bioRxiv - Biophysics 2022Quote: ... the emission passed to the acceptor channel is selected by a 690/70 nm band-pass filter (HQ690/70, Chroma Technology Corp. Rockingham Vermont, USA). The detectors used are single-photon avalanche photodiodes (SPAD ...
-
bioRxiv - Bioengineering 2022Quote: ... and Texas Red fluorescence detected by PMT2 (Hamamatsu Photonics R11322U-40-01) through a 680 nm short pass filter (Em2, Chroma Technology ET680sp-2p8).
-
bioRxiv - Biophysics 2022Quote: ... using an appropriate filter cube for Rho-PE fluorochrome (excitation filter HQ545/30x, dichroic mirror Q570LP and emission filter HQ610/75m) (Chroma Tech., Bellows Falls, VT, USA). Images were acquired using a 100X/1.30 OIL objective (Leica Microsystems ...
-
bioRxiv - Cell Biology 2022Quote: ... equipped with a DAPI/FITC/Rhodamine/CY5 filter set (Chroma Technology Corp) and a CoolSNAP HQ camera (Roper-Scientific) ...
-
bioRxiv - Cell Biology 2022Quote: ... dichroic beam-splitter was used (Chroma Technologies) and emission was split into red and green fluorescent channels using a Dual-view (Optical Insights) ...
-
bioRxiv - Cell Biology 2022Quote: ... a green laser (491 nm) was used for excitation and a 525/50 filter (Chroma Technologies) was used to detect emission ...
-
bioRxiv - Cell Biology 2022Quote: ... Fura-2 AM was imaged using alternate excitation filters at 340/26 (Semrock) and 387/11 (Semrock) and a 525/40 emission filter (Chroma Technology). The system was controlled using Olympus CellR software.
-
bioRxiv - Cell Biology 2022Quote: ... Emission was collected through appropriate emission band-pass filters obtained from Chroma Technologies Corp ...
-
bioRxiv - Cell Biology 2022Quote: ... an excitation quadband filter (ZET405/488/561/640x, Chroma Technology) and a quadband dicroic (ZET405/488/561/640bs ...