Labshake search
Citations for FHC :
151 - 200 of 638 citations since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2024Quote: ... The thalamic axons were stimulated by placing a custom-made bipolar electrode (FHC, M21CEP(CT1)) on the white matter to deliver 0.5 ms current pulses using a constant current stimulus isolator (A.M.P.I. ...
-
bioRxiv - Bioengineering 2024Quote: A tungsten electrode with an impedance of approximately 0.7MΩ (UEWMEGSEBN3M, FHC, Bowdoin, ME) was lowered to a depth of 1.8mm into a pre-selected site in the left motor cortex with the aim of targeting motor outputs in layer V ...
-
bioRxiv - Neuroscience 2024Quote: ... and advanced into the brainstem using a hydraulic oil-filled remote microdrive (Drum drive; FHC, Bowdoin, ME, USA). Neurophysiological activity was amplified (variable gain ...
-
bioRxiv - Bioengineering 2024Quote: ... A concentric bipolar stimulating electrode (CE2C65; FHC, Bowdoin, ME) was placed 100-500 µm from the target cells to evoke neurotransmitter release (Cat ...
-
bioRxiv - Animal Behavior and Cognition 2024Quote: ... with epoxylite insulation (FHC, Bowdoin, ME), and linear 16-channel arrays (Plexon ...
-
bioRxiv - Animal Behavior and Cognition 2024Quote: ... Stimulation was performed via tungsten microelectrodes (FHC, Bowdoin, ME). FEF sites were identified based on the landing point of the evoked eye movement following stimulation with currents ≤50μA.
-
bioRxiv - Bioengineering 2024Quote: ... was placed 100-500 µm from the target cells to evoke neurotransmitter release (Cat. #30209, FHC, ME, USA). Single electric stimulating pulses (200 ms ...
-
bioRxiv - Neuroscience 2023Quote: ... We placed a cluster bipolar stimulating electrode (FHC, Bowdoin, ME) parallel to the recorded layer 2-4 excitatory neurons and applied biphasic pulse of 100 us interval to evoke an EPSC ...
-
bioRxiv - Neuroscience 2023Quote: ... LFPs were recorded from the dorsal CA1 region using a tungsten electrode (3.5–4.5 MΩ, catalog #UEWMGCSEKNNM, FHC, USA) coated with a crystalline powder of 1,1′-dioctadecyl-3,3,3′,3′-tetramethylindocarbocyanine perchlorate (DiI) ...
-
bioRxiv - Neuroscience 2023Quote: ... ∼200 mA stimulus from a bipolar electrode (FHC) in the supra-pyramidal blade of the dentate gyrus was recorded with a borosilicate glass pipette taper-pulled to an impedance of 5-7 MOhm (Sutter Instruments ...
-
bioRxiv - Neuroscience 2023Quote: ... The mouse was kept at 37 °C with a feedback-controlled heating pad (40-90-8D DC, FHC). After being anesthetized ...
-
bioRxiv - Neuroscience 2023Quote: ... Synaptic currents were evoked with a concentric bipolar stimulating electrode (FHC) and evoked currents were stabilized for 5-10 min prior to data acquisition ...
-
bioRxiv - Neuroscience 2023Quote: ... tapered blunt-tip 300-500 kΩ tungsten recording electrodes (model #30070, FHC, Bowdoin ...
-
bioRxiv - Physiology 2023Quote: ... the animal was moved to a stereotactic frame with a nose cone and a feedback-controlled heating pad (40-90-8D, FHC) set to 37°C ...
-
bioRxiv - Neuroscience 2023Quote: ... The synaptic potentials were evoked with a Stimulus Isolator (A.M.P.I Isoflex) with a concentric bipolar electrode (FHC, CBARC75) placed in the stOri of CA2 on the experiment ...
-
bioRxiv - Neuroscience 2023Quote: The LC was subsequently targeted using three different electrode set-ups: 1) a single-channel tungsten microelectrode (0.00800/200 µm shank diameter, recording impedance ≥1.5 MΩ, FHC, USA), (n=9 rats) ...
-
bioRxiv - Neuroscience 2023Quote: ... Excitatory postsynaptic potentials (EPSPs) were evoked by stimulating superficial layers of cortex with 0.2-ms pulses (concentric bipolar electrodes, FHC). Under voltage-clamp modes ...
-
bioRxiv - Neuroscience 2023Quote: Tungsten epoxy-coated (FHC, 200 um thickness) or glass-coated (AlphaOmega ...
-
bioRxiv - Neuroscience 2023Quote: ... were regularly applied onto the eyes and body temperature was maintained at 36° C using a rectal probe and a heating-pad (FHC) placed under the body ...
-
bioRxiv - Neuroscience 2023Quote: ... 0.8%–1.5% maintenance) and placed onto a stereotaxic frame (Kopf) with a feedback-controlled heating blanket maintained at ∼36°C (FHC). Rimadyl (5 mg/kg ...
-
bioRxiv - Neuroscience 2023Quote: ... Core body temperature was maintained at 37.0 ± 0.2°C using a homeothermic heating pad (FHC Inc., Bowdoin, ME, USA). For VsEP testing ...
-
bioRxiv - Neuroscience 2023Quote: ... A concentric bipolar stimulating electrode (FHC, Bowdoin, ME) was placed over axon fibers in close proximity to the recorded neuron ...
-
bioRxiv - Neuroscience 2023Quote: ... Two single electrodes (Tungsten Microelectrode, FHC) were implanted to both sides of primary motor cortex (AP ...
-
bioRxiv - Neuroscience 2023Quote: ... fEPSPs were elicited by electric stimulation of CA1 region of stratum radiatum with a bipolar stimulating electrode (CBARC75, FHC, United States), and fEPSPs were recorded from the CA3 region of the stratum radiatum using low-resistance (3-5 M ...
-
bioRxiv - Neuroscience 2023Quote: ... Synaptic responses were evoked with Pt/Ir concentric bipolar (OP 200 µm, IP 50 µm, FHC) stimulating electrodes (0.1 ms and 20-100 µA ...
-
bioRxiv - Neuroscience 2023Quote: ... voltage-clamp experiments were performed with a stimulating electrode (CBAPB50, FHC) placed 100-200 μm laterally to activate layer 2/3 inputs ...
-
bioRxiv - Neuroscience 2023Quote: ... EPSPs were evoked at 0.1 Hz in layer 5 pyramidal neurons by electrical stimulation (100-200 µA) of layer 2/3 using an extracellular stimulating electrode (FHC, ME, USA). Membrane properties in mPFC pyramidal neurons were recorded before and 25 min after the 10Hz light stimulation ...
-
bioRxiv - Neuroscience 2023Quote: ... A concentric bipolar electrode (FHC, 125/50 µm extended tip) was placed in the stratum radiatum (Schaffer collateral fiber ...
-
bioRxiv - Neuroscience 2023Quote: ... A tungsten microelectrode was used as the stimulating electrode and a concentric bipolar microelectrode (Platinum-Iridium inner pole and a Stainless Steel outer pole) as the recording electrode (FHC, Inc., Bowdoin, ME). Recorded signals were amplified (1,000X) ...
-
Single neurons in thalamus and subthalamic nucleus process cardiac and respiratory signals in humansbioRxiv - Neuroscience 2023Quote: ... Electrophysiological recordings were acquired with a sampling rate of 48 kHz using the FHC 4000 LP (Lead Positioner) Neuromodulation Targeting System (manufactured by FHC, Inc. ...
-
bioRxiv - Neuroscience 2023Quote: ... Scalp incisions and burr-hole drilling were performed under local (lidocaine) and general (propofol) anesthesia and a microelectrode (FHC, Maine, US) was inserted through a guide cannula using a microdrive placed either on a Leksell frame (N = 13 surgeries ...
-
bioRxiv - Neuroscience 2023Quote: ... Data were digitized either using a Guideline 4000 LP+ amplifier (FHC, Maine, US) at 30 kHz (N = 21 surgeries) ...
-
bioRxiv - Neuroscience 2023Quote: ... or using a Guideline 5 amplifier (FHC, Maine, US) at 32 kHz and resampled offline to 30 kHz (N = 14 surgeries).
-
bioRxiv - Neuroscience 2023Quote: ... The core body temperature was maintained close to 37°C using a homeothermic heating map with a rectal probe (FHC, Bowdoin, ME). An incision was made in the skin on the back ...
-
bioRxiv - Cell Biology 2023Quote: ... KDM2A (FHC 00712), KDM3C (FHC36094E) ...
-
bioRxiv - Neuroscience 2023Quote: ... 1a) were randomly applied through the same electrode used for neural recording (0.5-1.5 MΩ, FHC, ME, US). The stimulus current was usually 20 μA ...
-
bioRxiv - Neuroscience 2023Quote: ... Electrical stimulation is provided by a CBCSE75 concentric bipolar electrode (FHC, Phymep, France) and an external A.M.P.I Iso-flex stimulator (Scop Pro ...
-
bioRxiv - Neuroscience 2023Quote: ... Local field potential (LFP) recordings from the parabrachial nucleus (PBN) were obtained using a 1 MΩ tungsten electrode (FHC, Bowdoin, ME) with its signal amplified (1000X ...
-
bioRxiv - Physiology 2023Quote: ... and concentric bipolar electrode (FHC Inc, Bowdoin, ME) placed 3 mm oral or anal of the imaging field of view ...
-
bioRxiv - Neuroscience 2023Quote: ... Body temperature was maintained close to 37°C using a homeothermic heating mat with a rectal probe (FHC). An incision was made in the skin on the back ...
-
bioRxiv - Neuroscience 2023Quote: ... body temperature was maintained at 37°C with a temperature controller system (FHC), and eyes were hydrated with Lacrigel (Europhta Laboratories) ...
-
bioRxiv - Neuroscience 2023Quote: ... a concentric bipolar electrode (FHC, Bowdoin, USA) was placed over one of the interganglionic bundles lying circumferentially to the recorded ganglion ...
-
bioRxiv - Neuroscience 2023Quote: ... either a single recording electrode (tungsten, FHC Inc., Bowdoin, ME, USA) or linear array (16ch or 32ch ...
-
bioRxiv - Neuroscience 2023Quote: ... Afferent PP fibers were stimulated with a concentric bipolar electrode (CBAPB125; FHC Inc., Bowdoin, ME, USA) positioned at SLM on the border of the subiculum and CA1 (for PP stimulation)(Perez-Rosello et al. ...
-
bioRxiv - Plant Biology 2023Quote: ... Seeds were placed on wet paper and kept at 4°C overnight and then transferred to a growth chamber (FHC-740 ...
-
bioRxiv - Neuroscience 2023Quote: ... A bipolar concentric stimulating electrode (FHC) controlled by an isolated pulse stimulator model 2100 (AM Systems ...
-
bioRxiv - Neuroscience 2023Quote: ... 4-20 tungsten microelectrodes (FHC, Inc.) were acutely placed in target regions (Figure S1) ...
-
bioRxiv - Neuroscience 2023Quote: ... A platinum-iridium bipolar stimulus electrode (FHC) was lowered into the caudal DCN or C1 DC ...
-
bioRxiv - Neuroscience 2023Quote: ... BC neuronal activity was acquired with single tungsten microelectrodes (1-2 MΩ, FHC Inc., USA). The unit’s principal whisker was determined by manual stimulation of individual whiskers ...
-
bioRxiv - Neuroscience 2023Quote: LC was targeted by a single tungsten microelectrode (<0.7 MΩ, FHC Inc., USA) from 5.6-5.9 mm below the dura ...