Labshake search
Citations for Tecan :
1 - 50 of 1724 citations for Hemoglobin High Sensitivity Colorimetric Detection Kit 10 Plate since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Plant Biology 2022Quote: ... Colorimetric NAD+-detection was performed in 96-well black bottom plates (Costar) on an Infinite M Plex (Tecan) plate reader at excitation (420 nm ...
-
bioRxiv - Cancer Biology 2024Quote: ... followed by colorimetric quantification using a plate reader (Tecan). By analyzing the optical density readings of the test samples and blanks ...
-
bioRxiv - Cancer Biology 2023Quote: ... The TNF-a high sensitivity ELISA [BE58351] was sourced from Tecan (IBL).
-
bioRxiv - Molecular Biology 2022Quote: ... Colorimetric analysis was performed with the plate reader Infinite ® M Nano (TECAN, Männedorf, Swiss). Each condition was analyzed in biological triplicates with technical duplicates.
-
bioRxiv - Neuroscience 2024Quote: ... Colorimetric reactions were analyzed using an Infinite M200 PRO ELISA plate reader (Tecan, Männedorf, Switzerland). Twenty grams of each sample were loaded onto a gel (NuPAGE 4 to 12% ...
-
bioRxiv - Neuroscience 2023Quote: ... Salivary concentrations were measured using commercially available chemiluminescence immunoassay with high sensitivity (Tecan – IBL International ...
-
bioRxiv - Microbiology 2022Quote: ... Nitrite was quantified using 96 well plates with the Griess colorimetric assay 62 and a plate reader (UV-Vis, Tecan, Spark) measuring the absorbance at 543 nm ...
-
Evidence for Involvement of WDPCP Gene in Alcohol Consumption, Lipid Metabolism, and Liver CirrhosisbioRxiv - Genetics 2023Quote: ... TAGs were assessed through colorimetric assays using 96-well microtiter plates and an Infinite M200Pro multifunction reader (TECAN). The assays were performed as previously described 18 ...
-
bioRxiv - Neuroscience 2023Quote: ... the following markers were measured with enzyme-linked immunosorbent assay (ELISA): high-sensitivity C-reactive protein (Tecan Group Ltd. ...
-
bioRxiv - Microbiology 2021Quote: ... All fluoro- and colorimetric measurements were performed using a Tecan Spark® M10 plate reader (Tecan Trading AG, Männedorf, Switzerland).
-
bioRxiv - Cancer Biology 2023Quote: ... The absorbance of colorimetric reaction was measured at 492 nm (reference wavelength: 620 nm) using an Infinite M200PRO Plate reader (TECAN). The percentage cytotoxicity was calculated as follows ...
-
bioRxiv - Biochemistry 2022Quote: ... and SPARK 10 M plate reader (TECAN). The fractions of the remaining activity were then calculated.
-
bioRxiv - Microbiology 2021Quote: ... The absorption of released hemoglobin was measured at 576 nm by an Infinite M200 Microplate reader (Tecan, Männedorf, Switzerland). Hemolysis rate (% ...
-
bioRxiv - Immunology 2020Quote: ... total amount of hemoglobin recovered in BAL) was determined from the standard curve generated by Magellan V 7.2 (Tecan) software.
-
bioRxiv - Systems Biology 2019Quote: ... Between 10-20 plates were cycled through a plate reader using a stacking system (Tecan M1000). We built a custom incubator box around the stacker towers to facilitate ventilation and fix the temperature to 37°C ...
-
bioRxiv - Biochemistry 2019Quote: ... Hemoglobin release upon lysis of the hRBCs was monitored at 570 nm using a microplate reader (TECAN GENios F129004; TECAN, Austria). The peptide concentration causing 5% hemolysis was considered to be the minimal hemolytic concentration (MHC) ...
-
bioRxiv - Biochemistry 2019Quote: ... Hemoglobin release upon lysis of the hRBCs was monitored at 570 nm using a microplate reader (TECAN GENios F129004; TECAN, Austria). The peptide concentration causing 5% hemolysis was considered to be the minimal hemolytic concentration (MHC) ...
-
bioRxiv - Bioengineering 2022Quote: Hemolysis was calculated from the hemoglobin absorbance of 200 μL RBC supernatant at 541 nm using a Spark multimode microplate reader (Tecan, Switzerland).24,36,37 Absorbance was used to calculate hemolysis as:24,37
-
bioRxiv - Biophysics 2023Quote: ... and measured the colorimetric absorbance at 560 nm with a spectrophotometer (Tecan, Infinite 200 Pro ...
-
bioRxiv - Neuroscience 2022Quote: ... The injection of buffer and luminescence detection was conducted by an automated injector and plate reader (Infinite M200 PRO, TECAN).
-
bioRxiv - Genomics 2022Quote: ... and IL-8 levels were quantified from streptavidin-Horseradish peroxidase associated with the detection antibody using absorbance read by an Infinite M1000 plate reader (Tecan).
-
bioRxiv - Microbiology 2023Quote: ... Cells were then diluted 1:10 into fresh LB medium in a 96 well-plate and OD600 was measured using a plate reader (Tecan). 100 µl of the diluted culture were placed in a new 96 well plate and lysed by addition of 10 μl of Lysis Buffer (1 mg mL-1 lysozyme in 1X BugBuster buffer (Sigma) ...
-
bioRxiv - Microbiology 2023Quote: ... Bacterial planktonic growth was monitored by measuring the OD600 of a 200-µl culture in 10-minute intervals in a microtiter plate using a plate reader (Tecan INFINITE M NANO+ ...
-
bioRxiv - Cancer Biology 2022Quote: ... was added to each well and plates were incubated 10 minutes at 37ºC and posteriorly read in the Spark MultiMode Plate reader (Tecan, Crailsheim, Germany).
-
bioRxiv - Microbiology 2021Quote: Growth kinetics for both plasmid-free and plasmid-containing strains were measured using cultures grown in 200 μl nutrient broth per well in a 96 well plate using an automated absorbance plate reader (Tecan Spark 10). Wells were inoculated using the same procedure described above ...
-
bioRxiv - Microbiology 2023Quote: ... Bacterial planktonic growth was monitored by measuring the OD600 of a 200-µl culture in 10-minute intervals in a microtiter plate using a plate reader (Tecan INFINITE M NANO+; Tecan; Männedorf; Switzerland).
-
bioRxiv - Biophysics 2021Quote: ... The colorimetric reaction was measured for 90 seconds at 412 nm using the Spark 10M (Tecan).
-
bioRxiv - Physiology 2020Quote: ... The endpoint colorimetric assays were performed using a Tecan Spark multimode microplate reader (Tecan, Mannedorf Switzerland). Area under the curve (AUC ...
-
bioRxiv - Pharmacology and Toxicology 2020Quote: ... The viability of the cells was assessed by measuring fluorescence in a plate reader (ex/em: 552±10/598±10, Tecan Spark 10M).
-
bioRxiv - Synthetic Biology 2022Quote: ... OD600 was measured every 10 min in a plate reader (Tecan Infinite® 200 PRO) shaking at 37 °C for 20 hours ...
-
bioRxiv - Biochemistry 2022Quote: ... Plates were scanned to determine the final OD by Spark 10 M microplate reader (TECAN).
-
bioRxiv - Molecular Biology 2024Quote: ... and pre-warmed in the Tecan plate reader at 42°C for 10 min (Tecan Infinite® M200 ...
-
bioRxiv - Synthetic Biology 2024Quote: ... Optical density at 600nm was monitored every 10 min using a plate reader (Tecan, Spark). Plates were then rapidly transferred to a thermostatically controlled hood at 37°C and kept shaking during the sampling procedure.
-
bioRxiv - Systems Biology 2022Quote: ... Luminescence was recorded after a further 10 min using the plate reader (Tecan Infinite M200 Pro).
-
bioRxiv - Microbiology 2022Quote: ... The OD595 was measured every 10 min for 12 hr in a plate reader (Infinite F200, Tecan) with incubation at 37°C ...
-
bioRxiv - Microbiology 2019Quote: ... and OD600nm and luminescence was measured every 10 minutes using a Tecan Infinite 200 plate reader (Tecan).
-
bioRxiv - Microbiology 2022Quote: ... The absorbance (OD595) was measured kinetically every 10 min in a Sunrise plate reader (Tecan, Männedorf, Switzerland) while incubating at 25 °C ...
-
bioRxiv - Molecular Biology 2019Quote: ... DNA concentration was measured with PicoGreen dsDNA Assay Kit (Quant-iT, ThermoFisherScientific, Waltham -USA) in 384-well plate format using an appropriate plate reader (200 PRO NanoQuant, Tecan Trading AG, Männedorf - Switzerland). Finally ...
-
bioRxiv - Microbiology 2020Quote: ... and 96-well plates in a gas controlled plate reader plate (Spark, Tecan). For the 96-well format ...
-
bioRxiv - Molecular Biology 2023Quote: ... A multi-detection microplate reader (Tecan Spark®) was used to measure fluorescence intensities ...
-
bioRxiv - Cancer Biology 2020Quote: ... The colorimetric absorbance at 450 nm and 650 nm (reference) was measured with an Infinite 200 pro multimode reader (TECAN).
-
bioRxiv - Immunology 2021Quote: ... and after 15 min incubation any colorimetric changes in the wells were detected using a microplate reader (Tecan M200 Pro).
-
bioRxiv - Cell Biology 2020Quote: ... + 0.05% NP-40) and colorimetric substrate was detected at 410 nm using a microplate reader (Tecan GENious Pro, Mannedorf, Switzerland).
-
bioRxiv - Microbiology 2019Quote: ... Measures were taken every 10 minutes during 20 or 42 hours in a plate reader (Tecan Infinite 200) at 37°C ...
-
bioRxiv - Plant Biology 2021Quote: ... all DNA samples were diluted 1:10 into 96-well plates using the Freedom EVO100 robot (Tecan, Switzerland). To assess potential bias caused by lab manipulations ...
-
bioRxiv - Microbiology 2022Quote: ... all DNA samples were diluted 1:10 into 96-well plates using the Freedom EVO100 robot (Tecan, Switzerland). To assess potential bias caused by lab manipulations ...
-
bioRxiv - Immunology 2021Quote: ... Plates were read after 30 minutes in a micro-plate reader (TECAN Spark plate reader) at 492 nm ...
-
bioRxiv - Systems Biology 2022Quote: ... Every 10 minutes the plate was transferred by a robotic arm into a multi-well fluorimeter (Infinite M200Pro, Tecan) that reads the bacteria optical density (OD ...
-
bioRxiv - Microbiology 2023Quote: ... Plates were incubated in a plate reader (Tecan Sunrise) at 30°C and OD600 readings were taken every 5 minutes for 100 cycles in total ...
-
bioRxiv - Physiology 2022Quote: ... The products of the colorimetric assay were measured spectrophotometrically at 590 nm using an Infinite M1000 microplate reader (Tecan, Durham, NC, USA). The values were expressed per amount of starting protein and accounting for the dried volume.