Labshake search
Citations for Tecan :
1 - 50 of 52 citations for 7 Bromo 3 methyl 1H indole since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Molecular Biology 2022Quote: ... Fluorescence for cell viability and luminescence for caspase-3/7 activity was measured using Infinite M1000 plate reader (Tecan). Caspase-3/7 activity was normalized to cell viability according to the manufacturer’s protocol.
-
bioRxiv - Genomics 2021Quote: The Ovation RRBS Methyl-Seq System 1–16 (NuGen, now Tecan) user manual was followed to generate sequencing libraries by enzymatically digesting 100 ng of gDNA using MspI ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... Libraries were constructed with the Ovation RRBS Methyl-Seq kit from Tecan, CA ...
-
bioRxiv - Evolutionary Biology 2023Quote: Whole genome bisulfite sequencing was performed using the Ovation Ultralow Methyl-seq kit (Tecan Genomics/Nugen ...
-
bioRxiv - Cancer Biology 2023Quote: ... Libraries were generated using the Ovation RRBS Methyl-Seq library preparation kit (Tecan Genomics, USA) as previously reported (Fennell et al ...
-
bioRxiv - Pathology 2020Quote: ... samples were used for library generation using the Ovation RRBS Methyl-Seq System (Tecan 0353-32) following the manufacturer’s instructions ...
-
bioRxiv - Cell Biology 2021Quote: ... and the fluorescence intensity of the dye was immediately recorded over a period of 1h at 26°C using a Spark multimode microplate reader (Tecan) with an excitation of 480nm and an emission of 530nm ...
-
bioRxiv - Cell Biology 2022Quote: ... The cells were then incubated in the treatment medium and the fluorescence intensity of the dye was immediately recorded over a period of 1h at 26°C using a Spark multimode microplate reader (Tecan) with an excitation of 480 nm and an emission of 530 nm ...
-
bioRxiv - Genomics 2023Quote: ... Reduced representation bisulfite sequencing (RRBS)77 libraries were generated with the Ovation® RRBS Methyl-Seq kit from Tecan Genomics (Baldwin Park ...
-
bioRxiv - Genomics 2020Quote: ... libraries were generated from 50 ng input genomic DNA using a scaled-down (half reactions) of the NuGEN Ovation RRBS Methyl-Seq System (Tecan) following the manufacturer’s recommendation ...
-
bioRxiv - Genomics 2022Quote: We generated single base resolution DNA methylation data using the Ovation RRBS Methyl-Seq System 1-16 (Tecan Life Sciences) with 100ng of input DNA ...
-
bioRxiv - Molecular Biology 2023Quote: ... RRBS libraries were constructed from 100 ng genomic DNA using the Ovation® RRBS Methyl-Seq library preparation kit (Tecan) according to the manufacturer’s instructions ...
-
bioRxiv - Neuroscience 2022Quote: ... Library preparations were performed using Ovation Ultralow Methyl-Seq DR Multiplex with TrueMethyl oxBS kit and workflow (Tecan, Redwood, CA). Single end 50 bp RRBS sequencing was performed using an Illumina 2500 according to the manufacturer’s instructions ...
-
bioRxiv - Developmental Biology 2024Quote: ... Uniquely indexed libraries were generated using the Ovation Ultralow Methyl-Seq DR Multiplex with TrueMethyl oxBS kit and workflow (Tecan). Each library was split into two aliquots for chemistry as follows ...
-
bioRxiv - Systems Biology 2024Quote: ... Sample libraries were generated from 150 ng genomic DNA and bisulfite conversion was performed using the Ovation RRBS Methyl-Seq System 1-16 with TrueMethyl oxBS kit (Tecan) per manufacturer protocol ...
-
bioRxiv - Neuroscience 2019Quote: ... The rest of the library preparation was carried out using the Ovation Ultralow Methyl-Seq DR Multiplex with TrueMethyl oxBS kit and workflow (Tecan, Redwood, CA). The libraries were split into two aliquots after adapter ligation ...
-
bioRxiv - Microbiology 2021Quote: ... Luminescence was detected within 1h using the one-step luciferase reagent from BPS following the manufacturer’s protocol in a multiplate reader from Tecan (Tecan Group Ltd, Crailsheim, Germany).
-
bioRxiv - Genomics 2022Quote: ... Whole genome oxidative bisulfite sequencing libraries were prepared according to manufacturer’s guidelines (Ovation Ultralow Methyl-Seq Library System, Tecan Genomics, Inc., Redwood City, CA) as previously described [55 ...
-
bioRxiv - Neuroscience 2023Quote: Absorbance spectra were generated using a multipoint 3×3 well scan of each well from 450 to 700 nm with a plate reader (Tecan Spark). Preliminary experiments determined that there was a significant difference in absorption by the phantom pucks when the absorbance was read at room temperature (approx ...
-
bioRxiv - Microbiology 2023Quote: ... ROS production was determined as a function of oxidation of the non- fluorescent DCF-H to 2′,7′-dichloroofluorescein (DCF) in an Infinite M PLEX plate reader (Tecan) with the following settings ...
-
bioRxiv - Plant Biology 2020Quote: ... Pathogenic growth was determined by measuring the optical density (OD) at λ = 405 nm 7 days after inoculation with a microtiter plate reader GENios Pro (Tecan) doing 5 measurements per well using multiple reads with 3 × 3 quadratic measurements per well).
-
bioRxiv - Physiology 2021Quote: ... 7’-dichlorodihydrofluorescein (DCF) in the samples were measured fluorometrically against DCF standards on a fluorescence plate reader (TECAN Infinite 200 Pro). The free radical content in homogenates is determined based on DCF standard curve ...
-
bioRxiv - Cancer Biology 2022Quote: ... It contains a CASP3/7 specific luminogenic substrate and luminescence was detected with a Tecan Spark® 10 M multiplate reader (Tecan). Signals were corrected for viable cells measured by CellTiter-Glo® Luminescent Cell Viability Assay (Promega ...
-
bioRxiv - Evolutionary Biology 2020Quote: ... Cultures were monitored in parallel for approximately 28 generations (7 days) in a fully automated robotic system (Freedom EVO, Tecan Ltd) connected with a microplate multi-reader (Infinite Reader M100 ...
-
bioRxiv - Cancer Biology 2022Quote: Drugs were added 3 days after plating using the Tecan D300e Digital Dispenser (Tecan). The time in between plating and addition of drugs was maintained to allow organoids to recover after plating ...
-
bioRxiv - Cell Biology 2022Quote: ... Luminescence was analyzed 3 minutes later at 25°C on a plate reader (Tecan Infinite M1000 Pro) using a 1000 ms acquisition time ...
-
bioRxiv - Microbiology 2023Quote: ... was measured at defined time points (0; 1,5; 3; 4,5 and 24 hours) using an automatic plate reader Spark Control Magellan (TECAN). Samples were removed from the uppermost layer of tube cultures ...
-
bioRxiv - Microbiology 2023Quote: ... measured at defined time points (0 ; 1,5 ; 3 ; 4,5 and 24 hours) using an automatic plate reader Spark Control Magellan (TECAN). Samples were removed from the uppermost layer of tube cultures ...
-
bioRxiv - Synthetic Biology 2023Quote: ... as defined by having OD600 in the range of 1.5 – 3 as approximated with a plate reader (TECAN). Cells were diluted to an OD600 of 1 in PBS (gibco) ...
-
bioRxiv - Microbiology 2024Quote: ... Plates were maintained at 37°C with 3 mm linear agitation in a Spark multimode plate reader (Tecan) and the OD600nm was acquired every 10 min ...
-
bioRxiv - Evolutionary Biology 2020Quote: ... Incubation at 25 °C was performed directly in 3 temperature-controlled spectrophotometers (Infinite® 200 PRO, Tecan, Reading, UK) that read the OD595 at intervals of 15 min ...
-
bioRxiv - Evolutionary Biology 2020Quote: ... Incubation at 25 °C was performed directly in 3 temperature-controlled spectrophotometers (Infinite® 200 PRO, Tecan, Reading, UK) that read the OD595 at intervals of 15 min.
-
bioRxiv - Evolutionary Biology 2020Quote: ... Incubation at 25 °C was performed directly in 3 temperature-controlled spectrophotometers (Infinite® 200 PRO, Tecan, Reading, UK) that read the OD595 at intervals of 15 min ...
-
bioRxiv - Microbiology 2023Quote: ... and luminescence was monitored every 30 min for 3 days during continuous incubation in an environmentally-controlled luminometer (Tecan).
-
bioRxiv - Cell Biology 2020Quote: ... the cells were incubated with the MTS solution for 3 hours at 37°C and absorbance at 492 nm was determined using the infinite F50 microplate reader (Tecan). Three independent experiments were carried out for each source.
-
bioRxiv - Evolutionary Biology 2020Quote: ... wells were washed 3 times with 1X PBS followed by immediate fluorescence measurement with a plate reader (TECAN infinite 200). Fluorescence of DAPI (350nm excitation /470nm emission ...
-
bioRxiv - Cancer Biology 2022Quote: ... and the NCI Experimental Therapeutics Program)) were dispensed in a 3-fold dilution series using a D300e Digital Dispenser (Tecan). Piericidin A (Cayman 15379 ...
-
bioRxiv - Bioengineering 2023Quote: ... The absorbance of three (N=3) samples for each condition was measured in triplicates on a plate reader (Infinite 200 Pro, Tecan) at 560 nm ...
-
bioRxiv - Neuroscience 2023Quote: ... Carbonato-cobaltate (III) complex ([Co(CO3)3]Co) absorbance was measured at 450 nm with a microplate reader (Tecan, Switzerland) and compared to the H2O2 standard model to determine H2O2 concentration ...
-
bioRxiv - Biophysics 2023Quote: ... Cells were back-diluted 1:100 in fresh CSM containing 2% glucose or 3% glycerol and shaken in a plate reader (Tecan) for 48 hours ...
-
bioRxiv - Cancer Biology 2023Quote: ... Stott and the NCI Experimental Therapeutics Program) were dispensed in a 3-fold dilution series using a D300e Digital Dispenser (Tecan). Cells were cultured with compound for 72 hours before viability was assessed using an ATP-based luminescent viability assay ...
-
bioRxiv - Molecular Biology 2024Quote: ... After 3 h of incubation at room temperature absorption at 562 nm was determined in a Tecan plate reader (Tecan Infinite® M200 ...
-
bioRxiv - Pharmacology and Toxicology 2022Quote: ... The concentration of H2O2 was determined indirectly by measuring the absorbance of the carbonato-cobaltate (III) complex ([Co(CO3)3]Co) at 450 nm using the Infinite F200 PRO multimodal microplate reader (Tecan, Switzerland), ti = 15 s was used for the calculation of the maximum velocity at a saturated concentration (Vmax ...
-
bioRxiv - Pharmacology and Toxicology 2022Quote: ... The concentration of H2O2 was determined indirectly by measuring the absorbance of the carbonato-cobaltate (III) complex ([Co(CO3)3]Co) at 450 nm using the Infinite F200 PRO multimodal microplate reader (Tecan, Switzerland). Due to interference ...
-
bioRxiv - Microbiology 2020Quote: ... Plates were incubated at 30 °C for 3 days before the absorbance of each well at 590 nm was measured using a Spark 10M plate reader (Tecan, Switzerland). All strains were assessed in triplicate ...
-
bioRxiv - Biochemistry 2021Quote: ... in the presence of bicarbonate ions based on the absorbance of the carbonato-cobaltate (III) complex ([Co(CO3)3]Co) at 450 nm using the Infinite F200 PRO multimodal microplate reader (Tecan, Switzerland). The concentration of H2O2 was determined from the model based on the standard curve obtained from serial dilutions of H2O2 in 1 x PBS.
-
bioRxiv - Neuroscience 2022Quote: ... in the presence of bicarbonate ions using the carbonato-cobaltate (III) complex ([Co(CO3)3]Co) absorbance peak at 450 nm with the Infinite F200 PRO multimodal microplate reader (Tecan, Switzerland). The same procedure was repeated with a modified H2O2 working solution containing 0.025 mM sodium azide (AZD ...
-
bioRxiv - Neuroscience 2023Quote: ... The H2O2 concentration was estimated from the ([Co(CO3)3]Co) absorbance at 450 nm using the Infinite F200 PRO multimodal microplate reader (Tecan, Switzerland) based on the linear model obtained with serial dilutions of H2O2 in PBS (R2 = 0.97 – 0.99) ...
-
bioRxiv - Evolutionary Biology 2021Quote: ... was added and metabolic rates were calculated from the time dependent reduction of resazurin to the fluorescent resorufin over 3 h at 37°C using an Infinite M200 Pro fluorescence plate reader (Tecan, Männedorf, Switzerland). Survival was determined from the difference in the metabolic rates of the fungus after amoeba confrontation and amoeba-free controls ...
-
bioRxiv - Immunology 2022Quote: ... the plates were transferred to the BSL-3+ Caps-It robotics system where 30 µL SARS-CoV-2 was added using a noncontact liquid handling system (Tecan, EVO 100) to achieve a multiplicity of infection (MOI ...