Labshake search
Citations for Tecan :
2401 - 2450 of 4358 citations since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Systems Biology 2022Quote: ... in a 96-well plate with a microplate reader (Tecan Infinite F200 Pro) with the excitation laser set at 485 nm and the emission laser at 528 nm ...
-
bioRxiv - Systems Biology 2022Quote: ... Plates were placed into a Spark Stacker (Tecan) in a 30 °C incubation room and the OD at 600 nm was recorded for 48 h ...
-
bioRxiv - Pharmacology and Toxicology 2022Quote: ... Luminescence intensity was measured using an Infinite M200 microplate reader (Tecan).
-
bioRxiv - Evolutionary Biology 2022Quote: ... on a 200 Pro Microplate Reader (TECAN). Due to extremely high triglyceride levels in all Pachón samples ...
-
bioRxiv - Immunology 2022Quote: ... which were then incubated for the indicated time at 37°C and measured using a luminometer (Tecan infinity M200 Pro). Bioluminescence was measured as relative light units (RLUs) ...
-
bioRxiv - Genomics 2022Quote: We prepared libraries for RNA sequencing from each RNA sample used in the RT-qPCR analyses according to Universal RNA-Seq with NuQuant + UDI (Tecan Genomics, Inc., Redwood City, CA) manufacturer instructions ...
-
bioRxiv - Immunology 2022Quote: ... Relative cholesterol concentration and the background (no cells) was determined in triplicates for each sample by measuring fluorescence activity with a fluorescence microplate reader (Tecan Infinite 200 PRO, reading from bottom) for 2h at 37°C with excitation wavelength of 530nm and an emission wavelength of 585nm ...
-
bioRxiv - Evolutionary Biology 2022Quote: ... followed by amplification of the product with the Ovation RNAseq System V2 (Tecan) (See Supplementary Methods for full RNA extraction protocols) ...
-
bioRxiv - Genetics 2022Quote: Each bulk RNA sample was processed for sequencing using the SoLo Ovation Ultra-Low Input RNaseq kit from Tecan Genomics according to manufacturer instruction ...
-
bioRxiv - Genetics 2022Quote: ... was measured at 442nm with a spark microplate reader (TECAN). Enzyme activity was assessed from the slope of the fluorescence = f (time ...
-
bioRxiv - Immunology 2022Quote: ... The absorbance was measured at 450 and 620 nm by a microplate reader (Tecan Sunrise). Neutralization titers were defined as the reciprocal of the highest serum dilution at which the optical density values were reduced by 50% relative to the virus control wells after subtraction of background optical density in cell control wells.
-
bioRxiv - Immunology 2022Quote: ... and quantitated by absorbance at 492 nm on a microplate reader (Tecan). The fentanyl-hapten structure used for this particular assay differs from the structures presented in supplementary figure 1 ...
-
bioRxiv - Immunology 2022Quote: ... and a luminescence reading was taken (Tecan Spark 10M) to generate Mtb growth curves in the presence of each treatment ...
-
bioRxiv - Immunology 2022Quote: ... The optical density (OD) at 405 nm was determined on an M1000Pro plate reader (Tecan) after 40 min ...
-
bioRxiv - Immunology 2022Quote: ... Experiments were performed using HydroSpeed™ microplate washer and Sunrise™ microplate absorbance reader (Tecan Männedorf, Switzerland). For peptide-ELISA ...
-
bioRxiv - Microbiology 2022Quote: ... in a spectrofluorometer (Tecan Spark®) at λex 490 nm / λem 525 nm ...
-
bioRxiv - Microbiology 2022Quote: ... over 120 min at excitation wavelength λ ex of 465 nm and emission at λ em of 535 nm using a spectrofluorometer (TECAN infinite M200 and TECAN Spark®). The data shown is exemplary for three independently performed biological replicates.
-
bioRxiv - Microbiology 2022Quote: ... in a spectrofluorometer (TECAN Spark®) at an excitation wavelength λex of 380 nm and an emission wavelength λem of 460 nm ...
-
bioRxiv - Microbiology 2022Quote: ... over 120 min at excitation wavelength λ ex of 465 nm and emission at λ em of 535 nm using a spectrofluorometer (TECAN infinite M200 and TECAN Spark®). The data shown is exemplary for three independently performed biological replicates.
-
bioRxiv - Microbiology 2022Quote: ... in a spectrofluorometer (TECAN Spark®) at λex 430 nm / λem 351 nm for Ac-WLA-AMC and λex 380 nm / λem 430 nm for Ac-Ala-hArg-2-Aoc-ACC ...
-
bioRxiv - Microbiology 2022Quote: ... and the initial turbidity (590 nm) was measured using a Spark® microplate reader (TECAN, Männedorf, Switzerland). The plates were then incubated in anaerobic jars at 37 °C for 5 days ...
-
bioRxiv - Immunology 2022Quote: ... the plate was read at the fluorescence intensity of 668 nm using a microplate reader (Spark, Tecan). Then ...
-
bioRxiv - Immunology 2022Quote: ... using a microplate reader (TECAN, Spark). Then TCID50 of the pseudovirus was calculated according to the Reed-Muench method (13) ...
-
bioRxiv - Evolutionary Biology 2022Quote: ... and the final concentration of each library was quantified using the Infinite M200 PRO NanoQuant spectrophotometer (TECAN, Männedorf, Switzerland).
-
bioRxiv - Evolutionary Biology 2022Quote: ... we quantified the starting DNA concentration using the Infinite M200 PRO NanoQuant spectrophotometer (TECAN, Männedorf, Switzerland).
-
bioRxiv - Immunology 2022Quote: ... Plates were read at 405 nm using a Tecan Sunrise Microplate reader (Tecan, Morrisville, NC). The resulting absorption values were normalized to those from PBS-treated wells to obtain the percentage of CspZ-YA IgG binding.
-
bioRxiv - Cell Biology 2022Quote: ... The cells were stained using an automated High Content Imaging pipline (Freedom EVO 200 robot, Tecan Group Ltd., Männedorf, Switzerland) and imaged using the INCell 2200 automated microscope (GE Healthcare ...
-
bioRxiv - Developmental Biology 2022Quote: ... Results were analysed using an Infinite microplate reader (Tecan Trading AG). Values were normalised according to the number of cells present in each sample.
-
bioRxiv - Cancer Biology 2022Quote: ... were printed in the indicated logarithmic concentration ranges using the D300e Digital Dispenser (Tecan). The DMSO concentration in each well was adjusted to the highest value on the plate which was set to < 0.1% of the assay volume ...
-
bioRxiv - Cell Biology 2022Quote: ... A Tecan freedom EVO liquid handler (Tecan), which is connected to the incubator ...
-
bioRxiv - Cell Biology 2022Quote: ... The absorbance at 450 nm was measured with a plate reader (TECAN, Infinite 200 PRO).
-
bioRxiv - Cell Biology 2022Quote: ... The amount of Choline was quantitated with a fluorescence microplate reader (TECAN, Infinite® 200 PRO) at Ex./Em ...
-
bioRxiv - Cancer Biology 2022Quote: ... Compounds were pre-printed with the D300e Digital Dispenser (Tecan), normalized for DMSO content ...
-
bioRxiv - Cancer Biology 2022Quote: ... trametinib 0.3 µM + decitabine 0.5 µM (D300e Digital Dispenser (Tecan). DMSO concentrations per well were normalized to the highest concentration on the plate ...
-
bioRxiv - Cell Biology 2022Quote: ... mitochondrial extracts were subjected to three freeze-thaw cycles in hypotonic buffer (10 mM TrisHCl) before activity analysis using an Infinite M200 plate reader (Tecan) in black bottom 96 well plates (Nunc ...
-
bioRxiv - Microbiology 2022Quote: ... 150 μl sterile water was added to the reservoirs between the wells and the plate was incubated inside of a small humidity cassette (Tecan) with 3 ml sterile water added to each reservoir ...
-
bioRxiv - Bioengineering 2022Quote: ... The fluorescence spectra were measured using a Safire2 microplate reader (Tecan).
-
bioRxiv - Bioengineering 2022Quote: ... and the OD at 490 nm quantified with a spectrophotometer (Tecan, Infinite M200 Pro). The assay was performed on different tissues on different days of culture ...
-
bioRxiv - Neuroscience 2022Quote: ... The absorbance was read at 540 nm using the Infinite® 200 PRO NanoQuant microplate reader (Tecan, Research Triangle Park, NC, USA).
-
bioRxiv - Microbiology 2022Quote: ... (Tecan, Switzerland).
-
bioRxiv - Microbiology 2022Quote: Measurements of GFP expression in an INFINITE M1000 PRO plate reader (Tecan Group Ltd., Switzerland) were done using fluorescence excitation at 483 nm and emission at 535 nm ...
-
bioRxiv - Microbiology 2022Quote: ... incubated with 300 μl of 96% ethanol for 35 min and the CV absorption was measured at OD595 using INFINITE M NANO+ plate reader (Tecan Group Ltd., Switzerland). Obtained CV values were normalized to the OD600 values of the respective biofilm cultures.
-
bioRxiv - Immunology 2022Quote: ... The absorbance was determined with a microplate ELISA reader (Photometer Sunrise RC, Tecan) at an optical density (OD ...
-
bioRxiv - Cell Biology 2022Quote: ... Measurements were performed on a Spark plate reader (TECAN).
-
bioRxiv - Cell Biology 2022Quote: ... in a Spark plater reader (Tecan), with excitation at 365 nm and emission at 407 nm (15 nm bandwidth for both wavelengths).
-
bioRxiv - Developmental Biology 2022Quote: ... with a Safire 2 microplate reader (Tecan).
-
bioRxiv - Developmental Biology 2022Quote: ... were performed according to manufacturer’s instruction and the fluorescence and luminescence signals were measured using a Safire 2 microplate reader (Tecan).
-
bioRxiv - Immunology 2022Quote: ... Cytotoxicity was quantified by a chromogenic MTS assay measured on a plate reader (Tecan, Männedorf, Switzerland) detecting remaining viable adherent tumor cells.
-
bioRxiv - Biochemistry 2022Quote: ... samples were incubated at 20°C for 15 min and the fluorescence polarisation was measured in 96-well half area flat bottom non-treated black polystyrene microplates (Costar) using Infinite M1000 Pro (Tecan) microplate reader set to 470 nm excitation wavelength and 530 nm emission wavelength ...
-
bioRxiv - Biochemistry 2022Quote: ... Mitochondrial swelling was determined by measuring a decrease in A550 in mitochondrial suspension using a plate reader (Infinite 200 Tecan, Austria) and 96-well plates.