Labshake search
Citations for Sartorius :
1 - 50 of 138 citations for Streptavidin magnetic beads since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Immunology 2023Quote: ... Streptavidin Biosensors (Sartorius) were hydrated for 20 minutes at 100 rpm in sample buffer 1 ...
-
bioRxiv - Immunology 2024Quote: ... Streptavidin sensors (Sartorius) were loaded with biotinylated natural Ara h 2 (InBio) ...
-
bioRxiv - Molecular Biology 2023Quote: ... Streptavidin-coated biosensors (Sartorius) were functionalized with either biotinylated mIL-12 or biotinylated mIL-12Rβ2D1-D6 ...
-
bioRxiv - Immunology 2022Quote: ... Streptavidin (SA) sensors (Sartorius) were functionalized with in vitro biotinylated ligands and quenched with a biotin solution ...
-
bioRxiv - Microbiology 2024Quote: ... using streptavidin biosensors (Sartorius). Virus binding affinity was normalised to fractional saturation and the concentrations of sugar loadings [30].
-
bioRxiv - Microbiology 2024Quote: ... using streptavidin biosensors (Sartorius). Virus binding affinity was normalised to fractional saturation and the concentrations of sugar loadings [37].
-
bioRxiv - Biophysics 2021Quote: ... Super Streptavidin (SSA) biosensors (Sartorius) were hydrated in 50 mM MES/NaOH (pH 6.5) ...
-
bioRxiv - Biochemistry 2022Quote: ... Streptavidin (SA) biosensors (Sartorius/ForteBio) (scFvs ...
-
bioRxiv - Biochemistry 2022Quote: ... Streptavidin (SA) biosensors (Sartorius/ForteBio) were loaded for 2mins with 100 nM biotinylated antigens (SARS-CoV-2 or SARS-CoV-1 spike proteins) ...
-
bioRxiv - Microbiology 2024Quote: ... the streptavidin sensor (Sartorius Corp) was coated with 50 nM Biotin-RBD or Biotin-HEL in 1×PBS for 30 min at 20°C ...
-
CXCL17 binds efficaciously to glycosaminoglycans with the potential to modulate chemokine signallingbioRxiv - Immunology 2023Quote: ... Streptavidin coated SAX biosensors (Sartorius) were hydrated for 10 mins in assay buffer 10 mM HEPES pH 7.4 ...
-
bioRxiv - Biochemistry 2023Quote: ... using Streptavidin SA biosensors (Sartorius) loaded with 40 µg mL-1 biotinylated CerS6 in SEC buffer containing 0.003 % (w/v ...
-
bioRxiv - Biochemistry 2024Quote: ... to streptavidin (SA) biosensors (Sartorius) previously hydrated in 10X Kinetics Buffer for at least 10 minutes ...
-
bioRxiv - Biochemistry 2024Quote: ... to streptavidin (SA) biosensors (Sartorius) that were pre-hydrated in 10X kinetics buffer for 10 minutes prior the experiment ...
-
bioRxiv - Microbiology 2021Quote: ... Streptavidin (SA) biosensors (Sartorius # 18-5019) were hydrated for 15 min in kinetics buffer (DPBS ...
-
bioRxiv - Microbiology 2022Quote: ... Streptavidin biosensors (SA, Sartorius #18-5019) were hydrated for a minimum of 30 min in compound-containing assay buffer prior to the start of each experiment ...
-
bioRxiv - Immunology 2021Quote: QBeads DevScreen: SAv (Streptavidin) (Sartorius 90792) were used to immobilize biotinylated Spike ...
-
bioRxiv - Biochemistry 2024Quote: ... Octet Streptavidin Biosensors (Sartorius, #18-5019) were used for all experiments ...
-
bioRxiv - Microbiology 2023Quote: ... Streptavidin (SA) biosensors (Sartorius # 18-5019) were hydrated for 15 min in kinetics buffer (DPBS ...
-
bioRxiv - Biochemistry 2023Quote: ... The streptavidin Octet SA biosensors (Sartorius) were loaded with biotinylated Tax-1 10-mer peptide (Biotin-Ahx-SEKHFRETEV-OH ...
-
bioRxiv - Cell Biology 2023Quote: ... streptavidin-coated biosensor tips (SA, Sartorius) were incubated for 40 s with 1.7-10 µg/ml biotinylated Drp1-Nbs diluted in Octet buffer (HEPES ...
-
bioRxiv - Immunology 2024Quote: ... The biosensors used were streptavidin (Sartorius). The biotinylated ligands loaded onto the streptavidin biosensors at 10 mg/mL were either biotinylated H1 protein or biotinylated IGF2R domains 1-10 protein (Kactus Bio) ...
-
bioRxiv - Microbiology 2022Quote: ... using Streptavidin (SA) Biosensors (Sartorius, 18-5019). The BLItz device was operated with the
-
bioRxiv - Molecular Biology 2023Quote: ... Streptavidin-coated sensors (Sartorius Octet SA Biosensors) were pre-soaked in BLI buffer for at least 10 min before runs and dipped into wells of a microplate (greiner bio-one 655209 ...
-
bioRxiv - Microbiology 2024Quote: ... using Streptavidin (SA) Biosensors (Sartorius, 18-5019). The BLItz device was operated with the Software BLItz Pro (version 1.3.1.3 ...
-
bioRxiv - Biochemistry 2022Quote: ... Fractions containing biotinylated primer bound to monovalent streptavidin were subsequently annealed to a 5’ biotinylated DNA template before binding to streptavidin biosensors (Sartorius). 200 nM of DNA substrates were added in the loading step ...
-
bioRxiv - Immunology 2021Quote: ... bound on streptavidin biosensor (Sartorius, Cat: 18-5119) and subjected to free floating Her2 to obtain the rate of association (ka) ...
-
bioRxiv - Biochemistry 2021Quote: ... using the Streptavidin sensors (18-5019 SA, Sartorius). Data were evaluated with the Data Analysis HT 12.0 software (Sartorius) ...
-
bioRxiv - Immunology 2022Quote: ... bound Streptavidin (SA) biosensors (Cat: 18-5019, Sartorius) (loading threshold set at 1.0 and 0.5 nm ...
-
bioRxiv - Biophysics 2022Quote: ... was loaded to a streptavidin biosensor tip (Sartorius) for 120 s ...
-
bioRxiv - Immunology 2024Quote: ... biotinylated antigens were loaded onto Streptavidin Biosensors (Sartorius), and His-tagged proteins were loaded onto NTA Biosensors (FortéBio) ...
-
bioRxiv - Microbiology 2024Quote: Streptavidin (SA)-coated probes (Sartorius; cat# 18-5136) were first hydrated for 10 min in a binding buffer containing 100 mM Tris-HCl at pH 8 ...
-
bioRxiv - Neuroscience 2024Quote: ... The biosensor used was Octet streptavidin Biosesor (SARTORIUS). Concentrations of the measured samples were 5 ...
-
bioRxiv - Bioengineering 2024Quote: ... Streptavidin-coated biosensor tips (18-009 Sartorius, Germany) were dipped into assay buffer (1x PBS ...
-
bioRxiv - Biochemistry 2021Quote: ... A streptavidin-coated SA sensor (Cat. 18-5019, Sartorius) was coated with 5 μg mL-1 biotinylated nanobodies for approximately 1 min ...
-
bioRxiv - Immunology 2022Quote: ... Octet® Streptavidin (SA) Biosensors (Sartorius, Cat # 18-5019) were incubated in 200 µL of 1ξ kinetics buffer (diluted in D-PBS ...
-
bioRxiv - Microbiology 2023Quote: ... The biotin-blocked reference streptavidin (SA) biosensor biosensors (Sartorius) were soaked with PBST+10% DMSO buffer for 10 min ...
-
bioRxiv - Biophysics 2024Quote: ... were used for coating streptavidin biosensor (SA biosensor, Sartorius). Protein concentrations were optimized before the final runs in the reaction buffer containing 50 mM Tris.HCl pH 8.0 ...
-
bioRxiv - Immunology 2024Quote: ... Octet Streptavidin (SA) sensor tips (Sartorius ForteBio 18-5019), tilted bottom (TW384 ...
-
bioRxiv - Biochemistry 2024Quote: Streptavidin (SA) biosensor tips (Sartorius, Cat no. 18-5019)
-
bioRxiv - Molecular Biology 2024Quote: ... An Octet streptavidin (SA) biosensor tip (Sartorius, Cat. #18-5019) was used to immobilize biotinylated Gal1 or sortilin before measurement of analyte association.
-
bioRxiv - Immunology 2023Quote: ... were immobilized onto a streptavidin biosensor (Sartorius Cat: 18-5020) and subjected to free-floating IgG variants to obtain the rate of association (Ka) ...
-
bioRxiv - Microbiology 2023Quote: ... equipped with High Precision Streptavidin (Octet SAX2) biosensors (Sartorius, USA) that were derivatized with biotinylated DNA fragments ...
-
bioRxiv - Immunology 2022Quote: ... biotinylated antigens (200 nM) were loaded onto Streptavidin biosensors (Sartorius) and then dipped into antibody solutions (200 nM ...
-
bioRxiv - Biochemistry 2024Quote: ... and loaded on Super Streptavidin Biosensors (SSA) (Sartorius, Göttingen, Germany) as follows ...
-
bioRxiv - Immunology 2024Quote: ... The Tamiflu-Biotin was immobilized on streptavidin biosensors (ForteBio, Sartorius) at a concentration of 0.25-0.5 µg/ml in 1xKB buffer ...
-
bioRxiv - Biochemistry 2024Quote: ... Streptavidin biosensors were hydrated in a 10x kinetics buffer (Sartorius) for 10 min prior to the experiment ...
-
bioRxiv - Biochemistry 2021Quote: ... All interactions studies were performed with Streptavidin biosensors (Sartorius, Göttingen, Germany) conjugated to the biotinylate DNA substrates ...
-
bioRxiv - Biochemistry 2021Quote: ... RBD variants were biotinylated and immobilized on streptavidin biosensors (SA, Sartorius). Dilution series ranging from 5-0.625 nM of bipNbs were applied and one reference was included per run ...
-
bioRxiv - Biochemistry 2022Quote: Avidity studies were achieved using streptavidin bio-sensors (SA sensor, Sartorius) where biotinylated CMY-2 was immobilized for 30 to 50 minutes at a concentration comprised between 10 and 50 μg/mL ...