Labshake search
Citations for Sartorius :
1 - 50 of 213 citations for Recombinant Human BTN3A2 Protein His Avi tagged Biotinylated since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biophysics 2024Quote: ... His-tagged dROS1 protein (construct 2-3) were loaded onto penta-His sensors (Sartorius) to a response unit of about 0.5 nm followed by quenching in 10 ng/mL biocytin (Sigma-Aldrich ...
-
bioRxiv - Synthetic Biology 2022Quote: ... His-tagged antigens using Anti-Penta-HIS biosensors (Sartorius/ForteBio). Antigen was loaded to a threshold of 1 nm shift ...
-
bioRxiv - Immunology 2021Quote: ... His-tagged ACE2 was immobilized onto Ni-NTA coated biosensors (Sartorius) before association of increasing concentrations of each RBD for 120 seconds followed by dissociation using HBS pH 7.4 for 360 seconds ...
-
bioRxiv - Immunology 2021Quote: ... recombinant SARS-CoV-2 S2-His-tag at 10 µg/mL was loaded on Anti-Penta-HIS (HIS1K) biosensors (Sartorius Corporation) for 1 min ...
-
bioRxiv - Immunology 2021Quote: His-tagged FcαRI (Sinobiological, Cat: 10414-H08H) were immobilized via Ni-NTA biosensor (Sartorius, Cat: 18-5101) and subject to free floating IgA variants to obtained ka ...
-
bioRxiv - Immunology 2022Quote: KD measurements of Fc-tagged Human FcμR (Cat: 13556-H02H, SinoBiological) immobilised on Anti-Human IgG Fc (AHC) (Cat: 18-5060, Sartorius) biosensors were performed on the Octet Red96® system with the loading threshold set at 1.0 nm and utilizing the recombinant Pertuzumab and Trastuzumab IgM VH whole antibodies variants in five serial diluted concentrations (12.5 to 200nM ...
-
bioRxiv - Biochemistry 2022Quote: ... Purified His6-MBP-tagged proteins were then concentrated with a 30,000 MWCO centrifugal concentrator (Sartorius) and buffer exchanged into 20 mM HEPES pH 7.5 and 50 mM NaCl for crystallization ...
-
bioRxiv - Microbiology 2020Quote: ... For all recombinant proteins,protein-containing fractions were pooled and buffer exchange to PBS via VivaSpin columns (Sartorius) was performed ...
-
bioRxiv - Biochemistry 2023Quote: ... C-terminally biotinylated SKP1-FBXO22 fusion proteins (WT or C326A) were immobilized onto SA biosensors (Sartorius) to a response level of 1 nm ...
-
bioRxiv - Immunology 2021Quote: ... S2-His-tag was immobilized on Anti-Penta-His (HIS1K) biosensors (Sartorius Corporation), and a concentration series of S2 binding mAb Fab at 200 ...
-
bioRxiv - Immunology 2021Quote: ... Anti-penta-HIS biosensors (Sartorius) were immersed in kinetics buffer (PBS + 0.5% BSA + 0.05% Tween-20 ...
-
bioRxiv - Immunology 2022Quote: ... Anti-penta-HIS biosensors (Sartorius) were immersed in kinetics buffer (PBS + 0.5% BSA + 0.05% Tween-20 ...
-
bioRxiv - Systems Biology 2022Quote: ... live-cell proliferation and expression of YFP-tagged proteins were tracked for 48 h using an Incucyte S3 device (Sartorius).
-
bioRxiv - Immunology 2022Quote: ... 200 nM of randomly biotinylated SARS-CoV-2 S or RBD protein antigen was captured using SA biosensors (18-5019, Sartorius). The biosensor was loaded with antigen for 5 min and then moved into the saturating mAbs at a concentration of 100 µg/mL for 10 min ...
-
bioRxiv - Plant Biology 2019Quote: ... The protein without His-Tag was concentrated using a Vivaspin 20 Ultrafiltration Unit (3 kDa molecular weight cutoff, Sartorius, www.sartorius.de). An appropriate volume was applied to a 1 ml loop of a gel filtration column (Superdex75 10/300 GL ...
-
bioRxiv - Biochemistry 2022Quote: ... or HIS 1K biosensors (Sartorius/ForteBio) (CrossMAb ...
-
bioRxiv - Biochemistry 2022Quote: Anti-His-tag (HIS1K) biosensors (Sartorius) were incubated in BLI buffer (0.002% v/v Tween-20 in 1× PBS ...
-
bioRxiv - Immunology 2022Quote: ... Biotinylated GPC-I53-50A was loaded onto SA sensors (Sartorius) at 100 nM ...
-
bioRxiv - Immunology 2022Quote: ... biotinylated antigens (200 nM) were loaded onto Streptavidin biosensors (Sartorius) and then dipped into antibody solutions (200 nM ...
-
bioRxiv - Immunology 2024Quote: ... biotinylated ODN-H was immobilized onto SA biosensor tips (Sartorius), and His-c-SLFN11 was added into wells for the association step ...
-
bioRxiv - Biochemistry 2021Quote: ... RBD variants were biotinylated and immobilized on streptavidin biosensors (SA, Sartorius). Dilution series ranging from 5-0.625 nM of bipNbs were applied and one reference was included per run ...
-
bioRxiv - Immunology 2023Quote: ... biotinylated RBD (10 μg/mL) was immobilised on streptavidin biosensors (Sartorius) for 300 s ...
-
bioRxiv - Immunology 2024Quote: ... Biotinylated mAbs were immobilized on streptavidin-coated biosensors (Sartorius, Goettingen, Germany) for 60 seconds at 50 µg/ml concentration ...
-
bioRxiv - Biochemistry 2022Quote: ... Biotinylated p97 was loaded on Super Streptavidin Biosensors (SSA) obtained from Sartorius as follows ...
-
bioRxiv - Bioengineering 2022Quote: ... and was captured by anti-Penta-His (HIS1K) sensors (Sartorius, 18-5120). The primary antibody was diluted to 150nM with a running buffer in wells ...
-
bioRxiv - Synthetic Biology 2023Quote: ... IgGs were assessed for binding to biotinylated antigens using streptavidin biosensors (Sartorius/ForteBio). Antigen was loaded at a concentration of 200nM ...
-
bioRxiv - Biophysics 2021Quote: ACE2 was biotinylated and immobilized onto the High Precision Streptavidin (SAX) biosensors (Sartorius, Germany) in assay buffer (50 mM Tris-HCl (pH 7.6) ...
-
bioRxiv - Bioengineering 2022Quote: ... Biotinylated defensin-based peptidomimetics were immobilized on streptavidin-conjugated (SA) Biosensors (Sartorius, 18-5019) by dipping the sensor in 150nM solution until the signal was saturated (unless otherwise noted in the data) ...
-
bioRxiv - Biochemistry 2023Quote: ... The 3’-biotinylated RNA was immobilized on an Octet® streptavidin (SA) Biosensor (Sartorius). 3 μg of biotinylated RNA were incubated per sensor for 300 s ...
-
bioRxiv - Cell Biology 2022Quote: ... or mCherry-tagged histone 2B (mCherry-H2B) were performed using an Incucyte SX5 (Sartorius Imaging). Images were taken once every 60 minutes to acquire videos of cells monitored over a 72-hour period.
-
bioRxiv - Biochemistry 2021Quote: ... 12xHis-tagged EPCRWT or EPCRY154A was immobilized on the surface of NiNTA pre-coated biosensors (Sartorius), at a concentration of 100 µg/mL ...
-
bioRxiv - Synthetic Biology 2022Quote: ... IgGs and Fabs were assessed for binding to biotinylated antigens using streptavidin (SA) biosensors (Sartorius/ForteBio) or to unbiotinylated ...
-
bioRxiv - Microbiology 2022Quote: ... The aliquots containing the purified His-ChuP were concentrated using a VivaSpin 6 column (Sartorius), and desalted by gel filtration in PD-10 column (GE Healthcare ...
-
bioRxiv - Immunology 2024Quote: ... 222 nM of 6xHis-tagged BG505 SOSIP was immobilized with nickel-charges tris-NTA (Ni-NTA) biosensors (Sartorius) for 10 min and transferred to PBS for 1 min to wash off unbound SOSIP ...
-
bioRxiv - Bioengineering 2023Quote: ... The biotinylated toxins were purified using buffer exchange columns (Vivacon 500, Sartorius, 3000 Da Molecular Weight Cut-Off) using the manufacturer’s protocol ...
-
bioRxiv - Immunology 2021Quote: RBD-His-tag at 5 µg/mL was first loaded on Ni-NTA (NTA) biosensors (Sartorius Corporation) for 15 sec and subsequently blocked with 5 µg/mL mAbs or BLI assay buffer for 5 min ...
-
bioRxiv - Immunology 2021Quote: ... biotinylated S1 binding mAbs at 25 µg/mL were first loaded on High Precision Streptavidin SAX biosensors (Sartorius Corporation) for 10 sec ...
-
bioRxiv - Neuroscience 2023Quote: ... we first loaded pre-equilibrated streptavidin biosensor probes with 400 nM of biotinylated peptides in 1X kinetics buffer (Sartorius) for 120 s ...
-
bioRxiv - Cell Biology 2022Quote: ... His-PKR was further concentrated to at least 10 mg/ml using Vivaspin centrifugal concentrator 30 K (Sartorius), snap-frozen in liquid nitrogen and stored at −80 °C.
-
bioRxiv - Immunology 2022Quote: ... Biotinylated NPNA peptides were diluted to 5 μg/mL in kinetics buffer (KB) and immobilized onto streptavidin BLI biosensors (Sartorius); His-tagged rsCSP was diluted to ~1 μg/mL in KB and loaded onto Ni-NTA biosensors ...
-
bioRxiv - Biochemistry 2022Quote: ... Fractions containing biotinylated primer bound to monovalent streptavidin were subsequently annealed to a 5’ biotinylated DNA template before binding to streptavidin biosensors (Sartorius). 200 nM of DNA substrates were added in the loading step ...
-
bioRxiv - Neuroscience 2022Quote: ... biotinylated VHH was diluted into assay buffer at 1 µg/mL and immobilized onto streptavidin coated biosensors (#18-5019, Sartorius) to a minimum response value of 1 nm on the Octet Red96 System (Sartorius) ...
-
bioRxiv - Immunology 2024Quote: ... Biotinylated OspA (5 µg/mL) in PBS containing 2% w/v BSA was captured onto streptavidin biosensors (#18-5019, Sartorius) for 5 min ...
-
bioRxiv - Cell Biology 2022Quote: ... GCP6-tagged purified γ-TuRC was then subjected to buffer exchange using Vivaspin 500 centrifugal concentrator (10 kDa MWCO, Sartorius VS0102) for a final NaCl concentration of 150 mM in eluate ...
-
bioRxiv - Immunology 2021Quote: ... His-tagged SARS-CoV-2 RBD was prepared at 8 μg/ml in Kinetics buffer (PBS 0.01% BSA) and loaded on pre-hydrated anti-penta-HIS biosensors (Sartorius) for 2.5 min ...
-
bioRxiv - Biophysics 2024Quote: ... The 50 ml containing 6-His-AdhE was concentrated to a final volume of 10.5 ml using a Vivaspin 20 centrifugal concentrator (Sartorius) with a molecular weight cut-off of 30 kDa and then dialysed against buffer A ...
-
bioRxiv - Immunology 2022Quote: ... Anti-Human Fc sensor tips (ForteBio, now Sartorius) were loaded with 200 nM mAb at a threshold of 0.8nm and then submerged into wells containing 100 nM (protomer/monomer concentration ...
-
bioRxiv - Biochemistry 2023Quote: ... Anti-Human Fc sensor tips (ForteBio, now Sartorius) were loaded with 200 nM mAb or FcACE2 to a threshold of 0.8 nm and then submerged into wells containing 100 nM (protomer/monomer concentration ...
-
bioRxiv - Immunology 2021Quote: ... His-tagged SARS-CoV-2 RBD was prepared at 8 µg/ml and loaded on pre-hydrated anti-penta-HIS biosensors (Sartorius) for 2.5 min ...
-
bioRxiv - Biochemistry 2022Quote: The specificity of the binding consisted in the immobilization of 2 μg/mL of purified VHHs on Anti-His coated sensors (His1K, Sartorius) via their His6 tag ...