Labshake search
Citations for Sartorius :
1 - 50 of 180 citations for Hepatitis E ORF2 protein mouse Fc tag since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Bioengineering 2023Quote: ... Mouse Fc-capture biosensor tips were purchased from Sartorius. Chicken plasma (cat # ...
-
bioRxiv - Microbiology 2023Quote: ... The tag-free RnpM protein was collected and concentrated using a Vivaspin turbo 15 (Sartorius, Germany).
-
bioRxiv - Immunology 2022Quote: ... Anti-hIgG Fc capture (AHC) or anti-mIgG Fc capture sensors (Sartorius) were functionalized with monoclonal antibodies ...
-
bioRxiv - Plant Biology 2019Quote: ... The protein without His-Tag was concentrated using a Vivaspin 20 Ultrafiltration Unit (3 kDa molecular weight cutoff, Sartorius, www.sartorius.de). An appropriate volume was applied to a 1 ml loop of a gel filtration column (Superdex75 10/300 GL ...
-
bioRxiv - Biochemistry 2022Quote: Anti-His-tag (HIS1K) biosensors (Sartorius) were incubated in BLI buffer (0.002% v/v Tween-20 in 1× PBS ...
-
bioRxiv - Immunology 2023Quote: ... Mouse antibodies (7.5 μg/mL anti-OVA and 5 μg/mL anti-RBD) were captured on pre-conditioned anti-mouse IgG Fc-capture biosensors (AMC, Sartorius) for 600 s ...
-
bioRxiv - Immunology 2022Quote: KD measurements of Fc-tagged Human FcμR (Cat: 13556-H02H, SinoBiological) immobilised on Anti-Human IgG Fc (AHC) (Cat: 18-5060, Sartorius) biosensors were performed on the Octet Red96® system with the loading threshold set at 1.0 nm and utilizing the recombinant Pertuzumab and Trastuzumab IgM VH whole antibodies variants in five serial diluted concentrations (12.5 to 200nM ...
-
bioRxiv - Immunology 2022Quote: ... Anti-Human Fc sensor tips (ForteBio, now Sartorius) were loaded with 200 nM mAb at a threshold of 0.8nm and then submerged into wells containing 100 nM (protomer/monomer concentration ...
-
bioRxiv - Biochemistry 2023Quote: ... Anti-Human Fc sensor tips (ForteBio, now Sartorius) were loaded with 200 nM mAb or FcACE2 to a threshold of 0.8 nm and then submerged into wells containing 100 nM (protomer/monomer concentration ...
-
bioRxiv - Molecular Biology 2024Quote: ... Anti-human IgG Fc capture (AHC) biosensor tips (Sartorius) were equilibrated for ten minutes in a 1:4 mixture of conditioned Freestyle 293 medium and 1X HBS EP+ to match the diluted media ...
-
bioRxiv - Immunology 2023Quote: ... E Coli or zymosan bioparticles (4619/4615/4617, Sartorius, USA) and the Total Red Object Integrated Intensity (Red Calibrated Unit (RCU ...
-
bioRxiv - Immunology 2023Quote: ... Antibodies were captured on anti-human Fc AHC2 tips (Sartorius). Data capture was performed using Octet Data Acquisition software version 9.0 (ForteBio) ...
-
bioRxiv - Immunology 2021Quote: ... S2-His-tag was immobilized on Anti-Penta-His (HIS1K) biosensors (Sartorius Corporation), and a concentration series of S2 binding mAb Fab at 200 ...
-
bioRxiv - Immunology 2021Quote: ... IgGs were immobilized on Anti-hIgG Fc Capture (AHC) biosensors (Sartorius Corporation) and a concentration series of 200 ...
-
bioRxiv - Synthetic Biology 2023Quote: ... and captured on Anti-hIgG Fc Capture (AHC) Biosensors (Sartorius 18-5060). Capture was recorded for 40 seconds ...
-
bioRxiv - Evolutionary Biology 2022Quote: ... IgG was loaded onto Anti-Human Fc Capture (AHC) biosensors (Sartorius, #18-5060). To reduce the avidity effect ...
-
bioRxiv - Immunology 2023Quote: ... BLI binding experiments were performed with Anti Human IgG Fc (AHC) biosensors (Sartorius 18-5060). Using Octet buffer (PBS with 0.1% Tween20) ...
-
bioRxiv - Immunology 2021Quote: RBD-His-tag at 5 µg/mL was first loaded on Ni-NTA (NTA) biosensors (Sartorius Corporation) for 15 sec and subsequently blocked with 5 µg/mL mAbs or BLI assay buffer for 5 min ...
-
bioRxiv - Immunology 2024Quote: ... Monoclonal Moo1 and Moo2 antibodies were immobilized on anti-human IgG Fc Capture (AHC) biosensors (Sartorius) to capture monoclonal antibodies at a concentration of 50 µg/mL for 5 min and washed with octet buffer ...
-
bioRxiv - Molecular Biology 2023Quote: ... The Hs53BP1 fragment without its GST tag was recovered in the flow through and concentrated using Vivaspin concentrator (Sartorius).
-
bioRxiv - Bioengineering 2023Quote: ... Antibody CSL362 hIgG1 (captured ligand) was captured by Anti-Human Fc capture biosensor (AHC) (Sartorius, PN: 18-5060) for 300s at 0.5µg/mL ...
-
bioRxiv - Biochemistry 2021Quote: The binding affinities for the RBD of B-RAF and RA domain of RASSF5 of the K-RAS-GMPPNP (wild-type and A59T/E) NMR samples were measured using an Octet RED-384 biolayer interferometry biosensor instrument (BLI, FortéBio, Sartorius) running Octet Data Acquisition 9.0.0.37 ...
-
bioRxiv - Immunology 2023Quote: ... Human antibodies (5 μg/mL or 7.5 µg/mL) were captured on pre-conditioned anti-human IgG Fc-capture biosensors (AHC, Sartorius) for 600 s ...
-
bioRxiv - Immunology 2021Quote: ... recombinant SARS-CoV-2 S2-His-tag at 10 µg/mL was loaded on Anti-Penta-HIS (HIS1K) biosensors (Sartorius Corporation) for 1 min ...
-
bioRxiv - Microbiology 2022Quote: ... and 0.5% nonfat dry milk) to 100 nM and immobilized for 60 s to anti-human IgG Fc capture biosensors (Sartorius). Sensors were transferred to assay buffer for 30 s to set the baseline ...
-
bioRxiv - Immunology 2020Quote: ... Protein A biosensors (FortéBio/Sartorius) were first hydrated for 10 minutes in Kinetics buffer ...
-
bioRxiv - Biochemistry 2023Quote: ... each Protein A biosensors (Sartorius) was pre-equilibrated in PBST buffer (PBS ...
-
bioRxiv - Immunology 2022Quote: ... Protein A biosensors (Sartorius, #18-5010) were hydrated in BLI assay buffer for 10-20 minutes and loaded onto an Octet Red96 BLI instrument (Pall ...
-
bioRxiv - Biochemistry 2022Quote: ... In our BLI experiments, ACE2 Fc-fusions are tethered to either Streptavidin biosensors (WT-ACE2, CVD293) (Sartorius®, Item no.: 18-5019) or ProtA biosensors (Sartorius® ...
-
bioRxiv - Immunology 2023Quote: All BLI for data shown in Figure 1 and Figure S1 was carried out on an OctetRED384 (ForteBio) using anti-human Fc-capture sensors (Sartorius, 18-5060) to immobilize anti-PfRH5 mAbs ...
-
bioRxiv - Biochemistry 2024Quote: Binding kinetics of ZHER2-CK2α were measured by biolayer interferometry (BLI) on an OctetRed384 using in-house made HER2-Fc-AviTag immobilized on streptavidin biosensors (Sartorius, 18-5021). Kinetic measurements were performed in PBS with 0.1% bovine serum albumin and 0.05% Tween 20.
-
bioRxiv - Pharmacology and Toxicology 2022Quote: ... as determined by weighing the e-liquid-containing cartridge before and after the carryover experiment using an analytical balance (Sartorius Practum, Göttingen, Germany). E-liquids for carryover experiments were chosen based on type of synthetic coolant present (WS-3 ...
-
bioRxiv - Microbiology 2019Quote: ... Residual proteins were then eliminated by filtration on 0.22-µm high-protein-retention Ministart syringe filters (Sartorius Stedim Biotech GmbH ...
-
bioRxiv - Microbiology 2020Quote: ... For all recombinant proteins,protein-containing fractions were pooled and buffer exchange to PBS via VivaSpin columns (Sartorius) was performed ...
-
bioRxiv - Neuroscience 2020Quote: ... using protein concentrator tubes (VIVASPIN 20, Sartorius). Both purified IgG fractions from patient and controls were re-tested on CBAs and the anti-IgLON5 IgG concentration was determined (titer 1:100) ...
-
bioRxiv - Cancer Biology 2020Quote: Proteins were transferred to nitrocellulose membrane (Sartorius). The membranes were blocked with 10% BSA (Santa Cruz Biotechnology ...
-
bioRxiv - Cell Biology 2024Quote: ... Proteins were concentrated using centrifugal concentrator (Sartorius) and further purified with size exclusion chromatography using a Superdex 200 column (GE Life Sciences) ...
-
bioRxiv - Microbiology 2023Quote: ... The eluted proteins were concentrated with a centrifugal device (MWCO 30 kDa for soluble EFNB2 proteins and 50 kDa for soluble Eph receptor proteins; Sartorius) before being separated on a Superdex 200 Increase 10/300 GL (Cytiva Life Sciences ...
-
bioRxiv - Cell Biology 2019Quote: ... Proteins were concentrated using a Vivaspin concentrator (Sartorius) with a half lower MWCO than the size of the protein being purified ...
-
bioRxiv - Biochemistry 2020Quote: ... Proteins were concentrated using Vivaspin centrifugal filters (Sartorius) of appropriate cut-offs ...
-
bioRxiv - Biochemistry 2020Quote: Purified proteins were concentrated with VIVASPIN concentrators (Sartorius) and dialyzed against E-Buffer with 1 mM DTT ...
-
bioRxiv - Biochemistry 2022Quote: ... using a 100kDa MWCO Vivaspin protein concentrator (Sartorius), aliquoted ...
-
bioRxiv - Biochemistry 2021Quote: ... Proteins were concentrated using Vivaspin concentrators (Sartorius Stedin) and the sample purity and homogeneity was assessed by SDS-PAGE.
-
bioRxiv - Biophysics 2021Quote: ... Eluted protein was concentrated using centrifugal concentrators (VivaSpin, Sartorius) and then assessed for successful labeling by measuring fluorescence using the following settings and the monochromator in the BioTek Synergy Neo2 plate reader ...
-
bioRxiv - Cell Biology 2023Quote: ... 2mM DTT and proteins concentrated via centrifugation (Vivaspin, Sartorius). Recombinant kinase was added to 10µl of 2X kinase buffer [40mM Hepes (pH 7.5) ...
-
bioRxiv - Biochemistry 2021Quote: ... All protein samples were concentrated using Vivaspin centrifugal concentrators (Sartorius). Denaturing gel electrophoresis was performed using NuPAGE 4-12 % Bis-Tris gels (Thermo Fisher Scientific) ...
-
bioRxiv - Cancer Biology 2022Quote: ... Then proteins were transferred into ultrafiltration tubes (10kDa, Sartorius AG) and washed three times with 50 mM NH4HCO3 at 14000g for 15 minutes ...
-
bioRxiv - Biophysics 2023Quote: ... Purified proteins were concentrated using centrifugal filter devices (Vivaspin, Sartorius). Protein concentration was estimated from its absorbance at 280 nm ...
-
bioRxiv - Biophysics 2023Quote: ... Protein samples were concentrated by ultrafiltration (5 kDa Vivaspin, Sartorius) and further purified by reverse phase chromatography using a preparative C4 column (Vydac 214 TP ...
-
bioRxiv - Biochemistry 2023Quote: ... The cleaved protein was then concentrated (Vivaspin 30,000 MWCO, Sartorius) and ultracentrifuged in a TLA-120.2 rotor (Beckman Coulter ...