Labshake search
Citations for Biotek :
301 - 350 of 2116 citations for Prolactin PRL ELISA Kit 1 Plate since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Molecular Biology 2021Quote: ... the samples’ absorbance was measured at 494 nm using a 1 cm pathlength cuvette and a plate reader spectrophotometer (PowerWave XS, BioTek Instruments). No free fluorophore was detected in the cassettes that had only AF488 (without collagen) ...
-
bioRxiv - Physiology 2024Quote: ... live cells stained with Hoechst 33342 (1:2,000 dilution) (ThermoScientific, Cat#62249) were enumerated using Cytation 5 plate reader (BioTek Instruments - Agilent). Values obtained from the Mito-Stress test were normalized per 1,000 cells.
-
bioRxiv - Systems Biology 2022Quote: ... The fluorogenic substrate provided with the kit was added and the plate was read for 30 minutes using a fluorometer (Biotek Synergy H1 microplate reader) at Ex:380/EM:460 nm.
-
Tuning trophoblast invasion in a gelatin hydrogel via soluble cues from the maternal-fetal interfacebioRxiv - Bioengineering 2020Quote: ... 100 μL triplicates were added to an opaque plate and luminescence was read immediately using a plate reader (BioTek Synergy HT Plate Reader and Gen5 software ...
-
bioRxiv - Microbiology 2021Quote: ... The 96-well plate was then placed on an Epoch 2 BioTek plate reader (BioTek Instruments, Winooski, VT, USA) and read every minute for 30min at an optical density of 640nm at 25°C ...
-
bioRxiv - Synthetic Biology 2020Quote: ... Overnight cultures were sub-inoculated into YPD media with different antifungal concentrations ranging from 0 µg/ml to 200 µg/ml in a 96 well plate at starting OD600 0.02 and grown for 36 hours in a plate reader (BioTek Synergy™ H1 ...
-
bioRxiv - Bioengineering 2020Quote: ... Supernatants were transferred to a new 96 well plate and measured with a Synergy HT plate reader (BioTek Instruments) at a wavelength of 562 nm (reference wavelength 630 nm ...
-
bioRxiv - Immunology 2021Quote: ... was added to the plate and absorbance measured at 405 nm using a plate reader (Biotek Epok, Model # 3296573). Appropriate control sera were included in the study.
-
bioRxiv - Synthetic Biology 2022Quote: ... Plasmid concentrations were quantified using the Cytation 5 plate reader with the Take3 Micro-Volume Plate (BioTek, Winooski, VT) and all fell in the range of 100-200 ng/μL ...
-
bioRxiv - Microbiology 2022Quote: ... The quality and yield of RNA were analyzed by the Take-3 Plate and Cytation 5 plate reader (BioTek). For the elimination of genomic DNA contamination ...
-
bioRxiv - Microbiology 2020Quote: ... Plates were imaged with both bright field and red channel RFP using a Cytation 5 plate reader (BioTek, VT). Images were analyzed for worm survival using CellProfiler ...
-
bioRxiv - Molecular Biology 2020Quote: ... added to each well immediately prior to the plate being read on a Synergy Neo2 Plate Reader (BioTek Instruments). The average luminescent signal for each condition was divided by that of CBL WT to determine fold change over CBL ...
-
bioRxiv - Evolutionary Biology 2022Quote: ... growth and fluorescence measurements were performed in the overnight plates using a Biotek H1 plate reader (Biotek, Vinooski, Vermont). Thus ...
-
bioRxiv - Microbiology 2023Quote: ... the plates were then read immediately at 492 nm in a ELx808 Plate reader (BioTek®, Winooski, VT, USA).
-
bioRxiv - Microbiology 2023Quote: ... Plates were read at a wavelength of 570 nm using cytation 3 multi-mode plate reader (BioTek Instruments, Inc.). The average absorbance of 0.1 % DMSO treated cells was used as cell control ...
-
bioRxiv - Physiology 2023Quote: ... The colorimetric assay was conducted in a 96-well plate and absorbance was measured using a plate reader (BioTek) at 570nm ...
-
bioRxiv - Microbiology 2024Quote: ... The plate was incubated at 37 °C with orbital shaking in a Synergy H1 plate reader (BioTek Instruments, Inc,) and OD600nm and luminescence was measured every 6 minutes ...
-
bioRxiv - Bioengineering 2024Quote: ... Plates were then washed 3x in 0.5% Tween 20 in PBS (PBST) using a plate washer (BioTek, Winooski, VT), followed by blocking with 300 µL of 5% dry milk (Rockland Immunochemicals ...
-
bioRxiv - Neuroscience 2021Quote: ... the serum was collected and analyzed by ELISA for FGF21 using an EL800 microplate reader (BioTek Instruments, Winooski, VT, USA) set with a detection wavelength of 450 nm and a correction wavelength at 540 nm ...
-
bioRxiv - Neuroscience 2021Quote: ... Optical density of the Enzyme Linked Immunosorbent Assay (ELISA) was measured at 450 nm using a Synergy HTX multi-mode microplate reader (Biotek) and compared to a standard curve to determine the final concentration ...
-
bioRxiv - Immunology 2020Quote: ... The tetrazolium crystals were dissolved by adding 200 μl/well isopropanol and the absorbance at 490 nm was measured using an ELISA reader (BioTek). To determine CC50 values ...
-
bioRxiv - Pharmacology and Toxicology 2019Quote: ... the production of formazan was evaluated by measuring the absorbance at 540 nm with an ELISA reader (BioTek, Winooski, USA). Values are mean ± S.E.M and results are expressed as the percentage of inhibition in cell viability in comparison to control (cells without treatment).
-
bioRxiv - Neuroscience 2023Quote: ... Equal volume of Griess reagent and supernatant from different regions of brain homogenate were incubated at 37 °C for 30 min followed by absorbance reading at 542 nm wavelengths spectrophotometrically in ELISA reader (Biotek). It was expressed as μg/mg protein.
-
bioRxiv - Cell Biology 2020Quote: ... The absorbance of 100 μL was measured a 96-well plate and absorbance at 558 nm read on a H1 plate reader (Biotek).
-
bioRxiv - Molecular Biology 2021Quote: Growth experiments were carried out in microtiter plates using a heated plate reader (Epoch 2 NS Microplate Spectrophotometer, BioTek Instruments). Strains H66 (wild type ...
-
bioRxiv - Microbiology 2020Quote: ... We incubated plates with continuous shaking and measured optical density every 15 min using a plate reader (BioTek Synergy MX). Growth curves were analyzed by fitting a modified Gompertz growth model (Zwietering et al ...
-
bioRxiv - Plant Biology 2019Quote: ... Absorbance was recorded at 540 nm in a 96-well clear plastic reading plate with two technical replicates in a 96 well plate reader (BioTek). Two-way student’s t-test was performed at 0.05 significance level ...
-
bioRxiv - Plant Biology 2019Quote: ... The 125 μl of reaction mixture was transferred into a 96-well clear plastic reading plate with 2 technical replicates and absorbance was measured at 540 nm in a 96 well plate reader (BioTek). Two-way student’s t-test was performed at a 0.05 significance level ...
-
bioRxiv - Microbiology 2019Quote: ... Plates were incubated for another 4 hours and the absorbance of the plate was read at 560 and 590 nm wavelength with the Synergy H1 hybrid multimode plate reader (BioTek).
-
bioRxiv - Evolutionary Biology 2020Quote: ... in LB media at 37°C using 12-well plates (Cornig, Ref. 353047) that were incubated in Synergy|HTX multi-mode plate reader (BioTek). Each population was growing in 1.5 ml of LB media ...
-
bioRxiv - Biochemistry 2020Quote: ... in a 384-well black-bottomed plate at 37°C for 30 min in a multi-well plate reader (SynergyMx, BioTek). For all concentrations of IQ peptide ...
-
bioRxiv - Microbiology 2022Quote: ... Single strain growth assays were performed three times using 96-well plates by taking OD600 measurements on a Tecan Infinite 200 PRO plate reader or BioSpa 8 (BioTek). Tolerance experiments were performed by exposing exponentially growing bacteria to ∼10xMIC of an antibiotic ...
-
bioRxiv - Microbiology 2022Quote: ... Plates were read for absorbance at 610 nm on a Synergy H1 plate reader (BioTek Instruments, Inc., Winooski, VT, USA).
-
bioRxiv - Biochemistry 2020Quote: ... The kinetics of turbidity development was determined by OD450 measurement in 96-well plate on a Synergy HTX plate reader (BioTek). Readings were taken once every 10 seconds and analyzed by the Gen5 Data Analysis Software (BioTek) ...
-
bioRxiv - Microbiology 2020Quote: ... The growth curves were performed in non-treated 96 well plate using plate reader (BioTek Synergy neo2 multi mode reader) in 200μl 7H9 media starting at OD600=0.1 ...
-
bioRxiv - Microbiology 2020Quote: ... Growth was monitored by measuring every 5 minutes the optical density of liquid cultures cultivated in 96 well plates at a wavelength of 600 nm using Cytation3 or Synergy H1 plate readers (Biotek).
-
bioRxiv - Biochemistry 2021Quote: ... subtilis strains in liquid MS medium was performed in a 96 well plates and absorbance at OD600 was measured using a multi-well plate reader (Eon, Biotek). Typically ...
-
bioRxiv - Synthetic Biology 2022Quote: ... The reactions were next transferred to a 384 conical well plate and incubated in the Synergy H1 plate reader (BioTek) at 30 °C for 3-4 h ...
-
bioRxiv - Pharmacology and Toxicology 2019Quote: ... optical density was measured in triplicates (80 µl volume/ well) in 96-well plates with the Synergy HT microtiter plate reader (BioTek Instruments ...
-
bioRxiv - Biochemistry 2019Quote: ... Cleavage was measured by monitoring the change of fluorescence at 445 nm after excitation at 345 nm on a plate reader (Synergy Neo2 Multi-Mode Plate Reader, Biotek).
-
bioRxiv - Microbiology 2021Quote: ... The resuspended samples were transferred to black 96-well plates and the fluorescence was measured using the plate reader Synergy H1 (BioTek). The excitation and emission settings for the detection of Amcyan and TurboRFP were 420/520 nm and 550/580 nm respectively ...
-
bioRxiv - Cancer Biology 2020Quote: ... A stop solution was added to the wells and the plates were read on a plate reader at 405 nm (BioTek Synergy H1 plate reader ...
-
bioRxiv - Physiology 2020Quote: ... Samples were then added to a 96-well plate and the absorbance was measured at 513 nm in a plate reader (Epoch 2 Microplate Spectrophotometer, BioTek). A standard curve of known elastin concentrations was used to quantify elastin content in test samples with linear regression ...
-
bioRxiv - Microbiology 2020Quote: ... plates were photographed and final optical densities at 600 nm (OD600) per well measured using a plate reader (BioTek Eon). Strains were categorized as sensitive (0.1-0.4) ...
-
bioRxiv - Microbiology 2020Quote: ... microtiter format growth was with 96-well plates incubated with shaking in a plate reader (Epoch 2 or Synergy H2M, Biotek). LB agar was supplemented with antibiotics [carbenicillin (Cb ...
-
bioRxiv - Microbiology 2022Quote: ... Batch growth kinetic assays were performed in 96-well plates and growth was measured using a micro-well plate reader (Biotek). For this ...
-
bioRxiv - Microbiology 2022Quote: ... Growth following phage infection was measured in 24-well plates at 15 min intervals with orbital shaking at 37 °C on a plate reader (Biotek). Data points reported are the mean of two technical replicates each for three independent growth curve experiments.
-
bioRxiv - Microbiology 2022Quote: ... Growth was then measured in 24-well plates at 15 min intervals with orbital shaking at 37 °C on a plate reader (Biotek). Data reported are the mean of three technical replicates each of four independent growth curve experiments.
-
bioRxiv - Molecular Biology 2022Quote: ... Absorbance at 360 nm was measured after 15 minutes using a 96-well plate using a plate reader (Cytation 3, BioTek).
-
bioRxiv - Biophysics 2022Quote: ... the plate was transferred to a prewarmed (37 °C) and 5 % CO2 Cytation V plate reader (BioTeK, Winooski, United States) and incubated for another 10 mins ...