Labshake search
Citations for Biotek :
51 - 100 of 2402 citations for Corticosterone Chemiluminescent ELISA Kit 5 Plate since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cell Biology 2024Quote: ... The plates were then analyzed with a Cytation 5 plate imager with Gen5 software (Biotek) to quantify the number of GFP positive and E protein positive cells.
-
bioRxiv - Biochemistry 2021Quote: ... After addition of all the samples blank reading was recorded using ELISA plate reader (BioTek, µ-QuantTM, USA) at 560 nm wavelength ...
-
bioRxiv - Biochemistry 2020Quote: ... absorbance at 450 nm with a 620 nm reference was measured in an ELISA plate reader (Epoch, BioTek). Monoclonal binders were sequenced and analyzed using VBASE2 (www.vbase2.org ...
-
bioRxiv - Immunology 2021Quote: ... all the plates were washed with PBS+0.01% Tween 20 (PBST) with the ELISA washer (BioTek, Sursee, Switzerland). The rest of the procedure is identical as described above ...
-
bioRxiv - Immunology 2023Quote: ... Absorbance was measured at 405 nm on an automatic ELISA plate reader (model EL311SX; Biotek, Winooski, VT, USA). The final Ig isotype concentration of antibody samples was calculated separately for each antibody isotype using a standard curve.
-
bioRxiv - Bioengineering 2021Quote: ... Sample fluorescence was measured by Cytation 5 plate reader (Biotek), and reporter concentrations were determined by using a known FITC ladder ...
-
bioRxiv - Pathology 2022Quote: ... Plates were placed in a Cytation 5 multimode reader (Biotek) at 37°C with 5% CO2 and continuous agitation and optical densities at 600 nm were recorded every 30 minutes for 20 hours.
-
bioRxiv - Immunology 2022Quote: ... Plates were read at 450 nm using Cytation 5 (BioTek).
-
bioRxiv - Microbiology 2022Quote: ... Luminescence was quantified using a plate reader (Cytation 5, BioTek). For each cell line ...
-
bioRxiv - Developmental Biology 2022Quote: ... plates were loaded into a Cytation 5 Imager (BioTek, CYT5PV) configured with a CO2 gas controller (BioTek ...
-
bioRxiv - Cancer Biology 2023Quote: ... Fluorescence was measured on a Cytation 5 plate reader (BioTek) with a 540/35 excitation filter and a 590/20 emission filter to identify wells with surviving cells ...
-
bioRxiv - Immunology 2022Quote: ... Optical density (OD) was measured at 450 nm and 620 nm using Powerwave XS ELISA Plate reader (Biotek Instruments). For calculations ...
-
bioRxiv - Cancer Biology 2020Quote: ... The ELISA was performed following manufacturer’s instructions and 450 nm absorbance was read on a Synergy 2 plate reader (BioTek).
-
bioRxiv - Biochemistry 2022Quote: ... The coated plates were blocked with 2%MPBST and washed with MilliQ + 0.05% Tween 20 in an ELISA washer (BioTek). Crude supernatant containing scFv diluted 1:1 with 2%MPBST was transferred to the corresponding well of both the antigen-coated and the control plates ...
-
bioRxiv - Biochemistry 2021Quote: ... The absorbance was measured at 470 nm after every 60 sec using ELISA plate reader (BioTek, µ-QuantTM, USA) and 6 reading were recorded.
-
bioRxiv - Microbiology 2020Quote: ... HRP activity was measured at 450 nanometer using tetramethylbenzidine substrate (BioFX) and an ELISA plate reader (EL-808, Biotek). Half-maximum effective concentration (EC50 ...
-
bioRxiv - Immunology 2020Quote: ... HRP activity was measured at 450 nanometer using tetramethylbenzidine substrate (BioFX) using an ELISA plate reader (EL-808, Biotek). Half-maximum effective concentration (EC50 ...
-
bioRxiv - Animal Behavior and Cognition 2022Quote: ... and the concentration of corticosterone was calculated using the software Gen5 (version 3.05, BioTek Instruments, Winooski, VT, USA). The detection limit for the assay is 27 pg/mL ...
-
bioRxiv - Cell Biology 2019Quote: ... Luminescence signals were measured using the Cytation 5 Plate reader (BioTek).
-
bioRxiv - Cancer Biology 2020Quote: ... Fluorescence intensities were measured on a Cytation 5 plate reader (Biotek) at an EX:360 nm and EM:460 nm ...
-
bioRxiv - Microbiology 2022Quote: ... Luminescence endpoint was read in a plate reader (Biotek Cytation 5). Percent cytotoxicity was calculated based on the luminescence reading of cysteamine HCl-treated wells compared to the medium only treated control wells.
-
bioRxiv - Cancer Biology 2022Quote: ... and data was acquired using a Cytation 5 plate reader (BioTek) using 400 nm excitation and 520 nm emission filters ...
-
bioRxiv - Neuroscience 2022Quote: Spectra were determined by using a plate reader (Cytation 5, BioTek) to quantify fluorescence from wells of the 96-well plates prepared above ...
-
bioRxiv - Bioengineering 2023Quote: ... Luminescence values were measured using a plate reader (BioTek, CYTATION 5). Luminescence values were measured for 1 hour ...
-
bioRxiv - Cell Biology 2024Quote: ... with 690nm as reference using a plate reader (Cytation 5, BioTek).
-
bioRxiv - Immunology 2019Quote: ... measured at a test wavelength of 490 nm and a reference wavelength of 630 nm in an ELISA plate reader (Biotek). The ODs from the control wells were subtracted from the test antigen wells to eliminate background antibody levels.
-
bioRxiv - Bioengineering 2022Quote: ... The reaction was stopped using stop solution (Beyotime) and the final result was read at 450 nm on an Elisa plate reader (Biotek). End-point titers were calculated as the dilution that emitted an optical density exceeding 4 times of background and calculated in Graphpad Prism software version 8 and R-Studio.
-
bioRxiv - Biochemistry 2020Quote: ... absorbance at 450 nm with a 620 nm reference wavelength was measured in an ELISA plate reader (BioTek Instruments, Epoch).
-
bioRxiv - Neuroscience 2022Quote: ... TMB reaction took place for 30 min and absorbance was measured at 450 nm with a 620 nm reference in an ELISA plate reader (Epoch, BioTek).
-
bioRxiv - Neuroscience 2022Quote: ... TMB reaction took place for 30 min and absorbance was measured at 450 nm with a 620 nm reference in an ELISA plate reader (Epoch, BioTek).
-
bioRxiv - Immunology 2024Quote: ... Reaction was stopped using 0.5 M/1N sulfuric acid and absorbance measured at 450 nm with subtracting reference at 620 nm using ELISA plate reader (Epoc, BioTek). For K18-hACE2 mice challenged with D614G for unspecific binding ...
-
bioRxiv - Synthetic Biology 2022Quote: ... Plasmid concentrations were quantified using the Cytation 5 plate reader with the Take3 Micro-Volume Plate (BioTek, Winooski, VT) and all fell in the range of 100-200 ng/μL ...
-
bioRxiv - Microbiology 2022Quote: ... The quality and yield of RNA were analyzed by the Take-3 Plate and Cytation 5 plate reader (BioTek). For the elimination of genomic DNA contamination ...
-
bioRxiv - Microbiology 2020Quote: ... Plates were imaged with both bright field and red channel RFP using a Cytation 5 plate reader (BioTek, VT). Images were analyzed for worm survival using CellProfiler ...
-
bioRxiv - Cell Biology 2020Quote: ... Imaging was performed on a Cytation 5 multi-mode plate reader (BioTek) using a 40× objective and images were captured through transmitted light 60 min after induction.
-
bioRxiv - Genetics 2021Quote: ... Fluorescence was measured using the Cytation 5 multi-mode plate reader (BioTek), and values were calculated from the mean of the triplicate compared to the standard curve.
-
bioRxiv - Immunology 2021Quote: ... The samples were analyzed on a Cytation 5 multimodal plate reader (BioTek) or a Tecan Infinite M1000 Pro plate reader and the data exported to spreadsheet software for statistical analysis ...
-
bioRxiv - Immunology 2021Quote: ... The samples were analyzed on a Cytation 5 multimodal plate reader (BioTek) and exported to spreadsheet software for statistical analysis ...
-
bioRxiv - Bioengineering 2021Quote: ... fluorescence of coculture supernatant were measured using Cytation 5 plate reader (Biotek).
-
bioRxiv - Microbiology 2021Quote: ... plates were imaged on an automated cell-imaging reader (Cytation 5, Biotek) and nucleocapsid-positive cells were counted using the manufacturer’s supplied software.
-
bioRxiv - Immunology 2021Quote: ... Cells were imaged with an automated multimode plate reader (Biotek, Cytation 5).
-
bioRxiv - Synthetic Biology 2020Quote: ... and bioluminescence spectrums were acquired with a Cytation 5 plate reader (BioTek). The gel filtration was performed with a HiPrep 16/60 Sephacryl S-100 column on an AKTA chromatography system (GE Healthcare) ...
-
bioRxiv - Microbiology 2023Quote: ... The luminescence was recorded by using Cytation 5 plate reader (BioTek inc). Based on the titration curve ...
-
bioRxiv - Cell Biology 2021Quote: ... The plate was incubated for 5 min at 37 °C and the change in absorbance was monitored continuously over 20 min using ELISA plate reader (Biotek, USA) at a wavelength of 340 nm.
-
bioRxiv - Microbiology 2021Quote: ... The depth of color (absorbance) was measured at 405 nm using an automated ELISA plate reader (model EL311SX; Biotek, Winooski, VT). The final Ig isotype concentration in the antibody sample was calculated using an appropriate standard curve ...
-
bioRxiv - Biophysics 2022Quote: ... the plate was transferred to a prewarmed (37 °C) and 5 % CO2 Cytation V plate reader (BioTeK, Winooski, United States) and incubated for another 10 mins ...
-
bioRxiv - Cancer Biology 2023Quote: ... Plates were placed on a plate shaker for 30 minutes at room temperature before the luminescence read on a Cytation 5 Imaging Plate Reader (BioTek).
-
bioRxiv - Bioengineering 2024Quote: ... Luminescence intensity from the opaque 384-well plate was measured using a microtiter well plate reader (BioTek® Cytation 5).
-
bioRxiv - Microbiology 2021Quote: ... The absorbance of formazan at 490 nm is detected using an enzyme-linked immunosorbent assay (ELISA) plate reader (ELx808, BioTek Instruments, Inc.). Each measure was performed in triplicate.
-
bioRxiv - Bioengineering 2021Quote: ... Sample fluorescence was measured for 60 minutes using Cytation 5 plate reader (Biotek).