bioRxiv - Biochemistry 2021Quote: ... and the absorbance spectrum between 400 and 700 nm was then recorded on a Cytation 3 Cell Imaging Multi-Mode Reader (BioTek).
-
bioRxiv - Microbiology 2021Quote: ... The fluorescence signals were read at a 365 nm excitation wavelength and a 450 nm emission wavelength using a Cytation 5 Cell Imaging Multi-Mode Reader (Biotek) and a standard curve was created ...
-
bioRxiv - Cell Biology 2020Quote: Cells were imaged in either a 96- or 24-well dish every two or four hours for up to five days using the Cytation 5 Cell Imaging Multi-Mode Reader (Biotek) driven by Gen5 software (Biotek) ...
-
bioRxiv - Biochemistry 2022Quote: ... by measuring the absorbance at 600 nm over time of samples in a 96-well clear plate (Costar) using a Cytation 5 Cell Imaging Multi-Mode Reader (BioTek). To remove background absorbance ...
-
bioRxiv - Physiology 2022Quote: ... Images of each well were captured every 24 hours for the duration of the experiment using a Cytation 5 Cell Imaging Multi-Mode Reader (BioTek).
-
bioRxiv - Immunology 2020Quote: ... and fluorescent virus-infected foci were detected 16-24 hours after inoculation with a Cytation 7 Cell Imaging Multi-Mode Reader (BioTek) with Gen5 Image Prime version 3.09 ...
-
bioRxiv - Immunology 2020Quote: ... and fluorescent virally infected foci were detected 16-24 hours after inoculation with a Cytation 7 Cell Imaging Multi-Mode Reader (Biotek) with Gen5 Image Prime version 3.09 ...
-
bioRxiv - Immunology 2020Quote: ... substrate the reaction was stopped with 1M sulfuric acid and absorbance was measured at 450 nm and 570 nm (reference wavelength) on the Cytation3 Imaging Reader (Biotek). The MN titers were expressed as half maximal inhibitory dilution (50% Inhibitory titer is ...
-
bioRxiv - Immunology 2022Quote: ... and the cell plate was sat in dark for 1 h before absorbance at 517 nm was recorded using Cytation 5 Cell Imaging Multi-Mode Reader (BioTek). All values were normalized to the background ...
-
bioRxiv - Immunology 2022Quote: ... Fluorescence was measured at Ex/Em: 485/535 nm recorded at 37°C every 5 min using Cytation 5 Cell Imaging Multi-Mode Reader (BioTek).
-
bioRxiv - Cancer Biology 2019Quote: ... Plates were read at 450 nm using the Cytation 3 Cell Imaging Multi-Mode Reader and Gen5 Microplate Reader and Imager Software (BioTek).
-
bioRxiv - Cancer Biology 2019Quote: ... treatment with chemical inhibitors or corresponding vehicle control was done 24 hr after seeding and spheroid growth imaged using spheroid imaging protocol of the Gen5 Image software on Cytation 3 (Biotek) using 10X objective lens.
-
bioRxiv - Cancer Biology 2020Quote: ... The number of cells was determined at the end of the run using the SRB assay as previously described (62) or in plate cell counting by Cytation 1 imaging reader (Biotek).
-
bioRxiv - Neuroscience 2020Quote: ... The intrinsic tryptophan fluorescence of L-PGDS was measured using Cytation 5 cell imaging multi-mode (Biotek Instrument Inc., USA) reader with λex=295 nm and λem=340 nm ...
-
bioRxiv - Biochemistry 2021Quote: ... and the absorbance spectrum between 400 and 700 nm was then recorded on a Cytation 3 Cell Imaging Multi-Mode Reader (BioTek).
-
bioRxiv - Cell Biology 2021Quote: ... Luminescence values were read using a multi-well luminometer (Cytation 3 Cell Imaging Multi•Mode Reader, BioTek Instruments, Winooski, Vermont).
-
bioRxiv - Bioengineering 2020Quote: ... Well plates were always protected from light and fluorescence measurements were carried out at 37°C and 5% CO2 at Cytation 3 (Cell Imaging Multi-Mode Reader) from Biotek® (USA) ...
-
bioRxiv - Immunology 2020Quote: ... After 5 to 10 min the reaction was stopped with 100 µl 1M sulfuric acid and the plates were read at 450 and 570 nm with the Cytation3 Imaging Reader (Biotek). The cut off value was defined as the average of all blank wells plus three times the standard deviation of the blank wells.
-
bioRxiv - Microbiology 2021Quote: ... The number of cells in each well was quantified based on Hoechst 33342 staining detected by Cytation 3 imaging reader (BioTek). Image analysis was performed using ImageJ and customized R scripts ...
-
bioRxiv - Immunology 2020Quote: ... After 5 to 10 min the reaction was stopped with 100 µl 1M sulfuric acid and the plates were read at 450 and 570 nm with the Cytation3 Imaging Reader (Biotek). The cut off value was defined as the average of all blank wells plus three times the standard deviation of the blank wells.
-
bioRxiv - Genetics 2020Quote: ... Infected cell frequencies as measured by mNeonGreen expression were assessed at 2 dpi by high content imaging (Cytation 5, BioTek) configured with bright field and GFP cubes ...
-
bioRxiv - Immunology 2022Quote: ... The assay was performed for the next 7 days and each day absorbance was read at 570 nm using Cytation 5 Cell Imaging Multi-Mode Reader (Agilent, BioTek). The assay was performed in triplicate.
-
bioRxiv - Microbiology 2022Quote: ... luminescence was quantified with an integration time of 1 s using the Cytation 5 Cell Imaging Multi-Mode Reader (BioTek).
-
bioRxiv - Cancer Biology 2022Quote: ... was added to the cell culture medium and incubated for 1-2 h before being subjected to measure absorbance at 490 nm using CYTATION-5 imaging reader (BioTek). EC50 (effective control to 50% growth inhibition ...
-
bioRxiv - Cell Biology 2022Quote: ... The absorbance was read at 450 nm (reference at 620 nm) using a Cytation 5 Cell Imaging Multi-Mode Reader (Agilent Biotek).
-
bioRxiv - Cell Biology 2022Quote: ... Scratches were imaged immediately after the addition of CM (0 hours) and after 8 and 24 hours incubation using the automated Cytation 1 Imaging Reader at 4X (BioTek, with Gen5 Version 3.04 software ...
-
bioRxiv - Immunology 2022Quote: ... The assay plates were then incubated for another 30 min before fluorescence was recorded using a Cytation 5 Cell Imaging Multi-Mode Reader (BioTek). Next ...
-
bioRxiv - Immunology 2022Quote: ... PI fluorescence was measured at Ex/Em: 535/617 nm at 37°C every 5 min using Cytation 5 Cell Imaging Multi-Mode Reader (BioTek). The obtained measurements were baseline corrected to DMSO at each timepoint and was presented as Ftreatment - FDMSO ...
-
bioRxiv - Immunology 2022Quote: ... The assay plates were then incubated for another 30 min before fluorescence was recorded using a Cytation 5 Cell Imaging Multi-Mode Reader (BioTek). Next ...
-
bioRxiv - Microbiology 2022Quote: ... and measured at an absorbance at 450 nm on a Perkin Elmer Wallac 1420 Victor2TM microplate reader or Cytation 5 cell imaging multi-mode reader (BioTek).
-
bioRxiv - Microbiology 2022Quote: ... and measured at an absorbance of 450 nm on a Perkin Elmer Wallac 1420 Victor2TM microplate reader or Cytation 5 cell imaging multi-mode reader (BioTek).
-
bioRxiv - Synthetic Biology 2023Quote: Fluorescence microscopy was performed with Cytation 5 Cell Imaging Multimode Reader (Bio-Tek) equipped with a BioSpa 8 Automated Microplate Incubator (BioTek). A 20× objective was used to collect bright-field images (autofocusing auto exposure) ...
-
bioRxiv - Neuroscience 2023Quote: ... blue and red fluorescence images were acquired per well at 20X every hour for 12h using the Cytation 5 cell imaging reader (Biotek). Imaging analysis was performed with Gen5 software (Biotek) ...
-
bioRxiv - Cell Biology 2023Quote: ... the exact number of nematode in each well was determined on a Cell Imaging Multi-Mode Reader (Cytation 1, BioTek) and was used for normalising/correcting OCR results.
-
bioRxiv - Neuroscience 2023Quote: ... Twenty phase and green fluorescence images were acquired per well from two technical replicates at 20X using the Cytation 5 cell imaging reader (Biotek). Images were acquired immediately after washing and every hour for four hours ...
-
bioRxiv - Cancer Biology 2023Quote: ... incubated for 4 h and fluorescence was read at 550 nm/590 nm on a Cytation 3 Imaging Reader (BioTek).
-
bioRxiv - Cancer Biology 2023Quote: ... The absorbance at 412 nm was measured every 15 sec for 5 min on a Cytation 3 Imaging Reader (BioTek). Total concentration of GSH + GSSG was calculated based on a GSH standard curve.
-
bioRxiv - Cancer Biology 2023Quote: ... Plates were placed on a plate shaker for 30 minutes at room temperature before the luminescence read on a Cytation 5 Imaging Plate Reader (BioTek).
-
bioRxiv - Neuroscience 2023Quote: ... green and blue fluorescence images were acquired per well from two technical replicates at 20X using the Cytation 5 cell imaging reader (Biotek). Imaging analysis was performed with Gen5 software ...
-
bioRxiv - Physiology 2023Quote: ... the exact number of nematode in each well was determined on a Cell Imaging Multi-Mode Reader (Cytation 1, BioTek) and was used for normalising/correcting OCR results ...
-
bioRxiv - Bioengineering 2023Quote: Cellular segmentation and high-content analysis was performed as part of the fully automated imaging protocol described above with the Gen5 software (Agilent BioTek). Individual cells were assessed for a number of intensity- and geometry-based metrics ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... The exposure lasted for 23 h before cells were lysed and quantification of luminescence was done on Cytation 5 cell imaging multimode reader (BioTek).
-
bioRxiv - Physiology 2023Quote: ... the exact number of nematode in each well was determined on a Cell Imaging Multi-Mode Reader (Cytation 1, BioTek) and was used for normalising/correcting OCR results ...
-
bioRxiv - Immunology 2024Quote: ... samples were qualitatively assessed using the Take3 plate on the Cytation 1 cell imaging multi-mode reader with Gen5 software (BioTek). Samples which met established quality guidelines set by the sequencing facility were sent to University of Texas Genomic Sequencing and Analysis Facility for TagSeq library prep and sequencing on NovaSeq with single end ...
-
bioRxiv - Microbiology 2023Quote: ... Microtiter plates containing technical replicates for each antibiotic-berberine pair were incubated for 18 hours with vigorous shaking using in Cytation5 Imaging Reader (Agilent BioTek). OD600 values were recorded every 15 minutes and select time points (0 ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... Two images per field (NucBlue and Alexa Fluor) and two fields per well were captured on a Cytation 5 cell imaging multimode reader (BioTek) (details in supporting methods and materials) ...
-
bioRxiv - Neuroscience 2024Quote: Microphotographs were obtained with the cell imaging multi-mode plate reader Cytation™ 5 (BioTek Instruments Inc., Winooski, VT, USA) using a green fluorescent protein (GFP ...
-
bioRxiv - Cell Biology 2022Quote: ... Plates were incubated at room temperature under agitation for 30 min and luminescence representing the number of viable cells was quantified with a Cytation 3 imaging reader (BioTek®).
-
bioRxiv - Immunology 2021Quote: ... Fluorescence was measured (ex = 370 nm/em = 460 nm) for 1 hour with a Cytation 3 imaging reader (BioTek, Winooski, VT). Changes in fluorescence were converted to thrombin concentrations using a calibration curve created from sequential dilutions of human thrombin ...
-