bioRxiv - Microbiology 2024Quote: ... Growth was measured by optical density at 600nm (OD600) at ∼10-minute intervals using a microplate stacker (BioTek BioStack) and microplate reader (BioTek PowerWave) ...
-
bioRxiv - Molecular Biology 2024Quote: ... Luminescence signals were measured using a Synergy 4 multimode microplate reader (BioTek). Concentrations of SAH were determined based on a standard SAH curve ...
-
bioRxiv - Microbiology 2024Quote: ... Activity was assayed by monitoring fluorescence 360/440 nm in a plate reader (Biotek). The assay was prepared in a 384-well ...
-
bioRxiv - Microbiology 2024Quote: ... Fluorescence 360/440 nm was measured while incubating at 37 °C with shaking in a plate reader (Biotek). Slopes were calculated over the first 5 minutes and used GraphPad to calculate Michaelis–Menten kinetic parameters ...
-
bioRxiv - Microbiology 2024Quote: ... The fluorescence was measured every 20 min using a platereader (Synergy HTX, BioTek) for 24 h under the optimal excitation and emission wavelengths for each fluorescence protein (Ex = 575 nm and Em = 620 nm for mCherry ...
-
bioRxiv - Microbiology 2024Quote: ... and A600 measurements were taken every 20 min using a platereader (Synergy HTX, BioTek). The growth rates of the exponential phase were calculated.
-
bioRxiv - Neuroscience 2024Quote: Microphotographs were obtained with the cell imaging multi-mode plate reader Cytation™ 5 (BioTek Instruments Inc., Winooski, VT, USA) using a green fluorescent protein (GFP ...
-
bioRxiv - Neuroscience 2024Quote: ... Cell images were processed using Gen5™ software (BioTek Instruments Inc.). The results were expressed as the percentage of positive cells out of the total number of cells.
-
bioRxiv - Molecular Biology 2024Quote: Fluorescence polarization (FP) method was used to measure the binding affinity with Synergy 4 Microplate Reader (BioTek). Aliquots (5 nM ...
-
bioRxiv - Neuroscience 2024Quote: ... and the fluorescence intensity of FFN206 was measured with excitation/emission wavelength at 360 nm/460 nm using a microplate reader (BioTek Synergy2 Microplate Reader). All statistical analyses were performed with one-way ANOVA followed by Dunnett’s multiple comparisons test by comparing WT with mutants using GraphPad Prism v9.3.1 ...
-
bioRxiv - Neuroscience 2024Quote: ... the fluorescence intensity of FFN206 was measured with excitation/emission wavelength at 360 nm/460 nm using a microplate reader (BioTek Synergy2 Microplate Reader). In this assay ...
-
bioRxiv - Neuroscience 2024Quote: ... which used bovine serum albumin standards to create a best fit linear regression line based on protein concentrations using the 562nm absorbance mode of a microplate reader and its Gen5 Data Analysis program (Biotek, Winooski, VT). Equal amounts of protein were resolved in SDS-polyacrylamide gels and electrophoretically transferred to nitrocellulose membranes (Bio-Rad ...
-
bioRxiv - Microbiology 2024Quote: ... DNA analysis using the Take 3 plate and Eon plate reader (BioTek) revealed quantities of at least 26.4 ng µl-1 and a purity of at least 1.8 260/280nm.
-
bioRxiv - Neuroscience 2024Quote: ... was measured in cell culture medium collected from the top and bottom chamber of the Transwell system (three technical replicates per Transwell) using a fluorescent plate reader (Biotek Synergy H4) and clearance volume calculated as previously described (37,38).
-
bioRxiv - Microbiology 2024Quote: ... for 20 min and were imaged with a Cytation 3 Imager (BioTek). The diameter of SAG1-positive vacuoles was determined using CellProfiler 4.2.4(60) ...
-
bioRxiv - Microbiology 2024Quote: ... Cultures were grown at 37 °C with orbital shaking on a plate reader (Biotek) for 6 hours ...
-
bioRxiv - Microbiology 2024Quote: ... the released luminescence was quantified using the Synergy™ H1 luminometer (BioTek, USA).
-
bioRxiv - Microbiology 2024Quote: ... Growth was tracked in an Epoch 2 Microplate Spectrophotometer (BioTek Instruments) at 37°C with linear shaking at 237 cpm (4 mm ...
-
bioRxiv - Microbiology 2024Quote: ... to facilitate gas exchange and OD600 readings were collected using a plate reader (BioTek) for 48 hours ...
-
bioRxiv - Microbiology 2024Quote: ... OD600 was measured every 15 min for 24 h in an Epoch2 reader (BioTek) at 37°C orbital shaking.
-
bioRxiv - Microbiology 2024Quote: ... 525 nm emission) or luminescence (integration time 1 min) was measured using a Synergy H1 plate reader (Biotek). In some experiments ...
-
bioRxiv - Microbiology 2024Quote: ... an E.Z.N.A soil DNA kit (Omega Biotek,GA, USA) was used to extract total genomic DNA ...
-
bioRxiv - Microbiology 2024Quote: ... The OD was determined at 630 nm (OD630) in a BioTek Synergy HT plate reader (BioTek, Winooski ...
-
bioRxiv - Microbiology 2024Quote: ... 450nm absorbance was then measured using the SynergyH1 plate reader (BioTek, Winooski, VT, USA) every 5 minutes over the course of two hours.
-
bioRxiv - Microbiology 2024Quote: ... Plates were then washed using an automated plate washer (BioTek) and incubated for 1 h with mouse anti-rhesus IgG HRP-conjugated secondary antibody (Southern Biotech ...
-
bioRxiv - Microbiology 2024Quote: ... Optical density (OD595) was measured every 15 min for 24 h using an Epoch 2 microplate reader (BioTek). Lag time and Vmax were assessed using the plate reader software (Gen5) ...
-
bioRxiv - Microbiology 2024Quote: ... which was performed with a Lionheart FX automated microscope (Agilent BioTek; Santa Clara, CA, USA). For spinning disc confocal microscope ...
-
bioRxiv - Immunology 2024Quote: ... Image acquisition for calculating TFEB N:C ratio and for Lysotracker mean fluorescence intensity (MFI) was performed using Lionheart FX automated microscope (Biotek) and Gen5 software (version 3.13).
-
bioRxiv - Molecular Biology 2024Quote: ... the OD600 and fluorescence values were measured using the Synergy H4 Hybrid Reader (BioTek). The fluorescence measurement wavelength is set as follows ...
-
bioRxiv - Molecular Biology 2024Quote: ... plates were imaged using Cytation 5 imaging reader (BioTek) using a 4x magnification objective lens and predefined YFP channel with an excitation wavelength of 469 nm and emission wavelength of 525 nm ...
-
bioRxiv - Molecular Biology 2024Quote: ... the number of infected cells in each well was determined using Cytation 5 imaging reader (BioTek) using a 4x magnification objective lens and predefined YFP channel with an excitation wavelength of 469 nm and emission wavelength of 525 nm ...
-
bioRxiv - Molecular Biology 2024Quote: ... plaques were imaged using a Cytation 5 imaging reader (BioTek). Field of view (FOVs ...
-
bioRxiv - Immunology 2024Quote: ... Live images were recorded with Lionheart FX or Cytation 5 (BioTek) and processed in Gen5 software ...
-
bioRxiv - Immunology 2024Quote: ... and the fluorescence values of the wells were also recorded by Cytation 5 (BioTek).
-
bioRxiv - Molecular Biology 2024Quote: ... ALP and ARS plates were imaged using an inverted conventional brightfield microscope (BioTek, Lionheart FX) affixed with RGB imaging cubes ...
-
bioRxiv - Molecular Biology 2024Quote: ... and the Fluc luminescence was measured by a Synergy2 multi-mode microplate reader (Biotek Instruments). After measuring the Fluc luminescence ...
-
bioRxiv - Molecular Biology 2024Quote: ... casei growth was quantified at 595 nm on an Epoch Microplate Spectrophotometer (Biotek Instruments). Total folate measurements for the liver samples were normalized to protein concentration as measured using the Lowry-Bensadoun Assay (Bensadoun and Weinstein ...
-
bioRxiv - Microbiology 2024Quote: ... Optical density measurements (OD600) were performed every 5 minutes over 20 hours on a Synergy H1 (Biotek) microplate reader (chamber supplemented with 5% CO2 ...
-
bioRxiv - Molecular Biology 2024Quote: Growth curves of R1 and RecA KD at variable kGy dosages were evaluated using a Plate Reader (BioTek) and OD600 was calculated using a bacterial calibration curve for D.radiodurans strains ...
-
bioRxiv - Immunology 2024Quote: ... Images were processed with the GEN5 software version 3.09 (Biotek) and the ImageJ software (NIH).
-
bioRxiv - Biochemistry 2024Quote: Experimental procedures were carried out using a Perkin Elmer EnVision® 2104 Multilabel Reader (BioTek, USA) equipped with 485□nm excitation and 535□nm emission filters for the FITC ...
-
bioRxiv - Neuroscience 2024Quote: ... Synergy 4 (BioteK) plate reader was used to determine the concentration of LCN2 ...
-
bioRxiv - Neuroscience 2024Quote: ... and read with the Synergy NEO2 multimode reader (BioTek). HeLa cells were transfected with siRNAs using Lipofectamine 2000 (Invitrogen) ...
-
bioRxiv - Bioengineering 2024Quote: ... The absorbance at 630 nm was recorded on the SynergyHT plate reader (BioTek) and the values were normalized to the weight of the construct.
-
bioRxiv - Molecular Biology 2024Quote: ... f-LCN2 concentrations were determined in the collected supernatants using the color reagents of hydrogen peroxide and tetramethylbenzidine at 450 and 570 nm by a microplate reader (Biotek Synergy HT ...
-
bioRxiv - Neuroscience 2024Quote: ... using a microplate photometer (BioTek). The maximal releasable LDH in each group was obtained by incubation with 1% Triton-100.
-
bioRxiv - Microbiology 2024Quote: ... raw images of mNG fluorescent foci were acquired using CytationTM 7 (BioTek) armed with 2.5× FL Zeiss objective with wide field of view and processed using the software settings (GFP [469,525] threshold 4000 ...
-
bioRxiv - Microbiology 2024Quote: ... Fluorescence microscopy images (4X and 40X magnification) were acquired with the Cytation™ 3 Cell Imaging Multi-Mode Reader (BioTek® Instruments). Macrophage-residing HIV-1 in VCCs was analyzed with 40X magnification images ...
-
bioRxiv - Microbiology 2024Quote: ... the optical density of the culture was measured at 600 nm (OD600) using a SynergyTM H1 microplate reader (BioTek, USA).
-
bioRxiv - Microbiology 2024Quote: ... The plate was sealed with a gas permeable seal (Azenta Life Sciences 4ti-0516/96*) and incubated at 37°C and 237 cpm for indicated times in a Synergy H1 plate reader (Agilent BioTek). OD600nm was measured every 10 min ...