Labshake search
Citations for Biotek :
101 - 150 of 338 citations for 4 4 Methylphenyl 1H pyrrole 3 carbonitrile since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2022Quote: ... The plate was incubated with shaking at 37 °C and the optical density of each well was measured at a wavelength of 600 nm (BIOTEK, Synergy 4). The MIC values were taken as the lowest concentration for which no growth was discernible (<0.05 OD600 ...
-
bioRxiv - Microbiology 2024Quote: ... NBT was reduced to blueformazan and spectrophotometrically read at OD 650 nm using a Synergy 4 microplate reader (BioTek, Santa Clara, USA). The concentration at which the drugs were able to inhibit 50% parasite growth (IC50 ...
-
bioRxiv - Microbiology 2023Quote: ... The resulting 1,472 SICs were arranged in 16 96-well plates and incubated in the anaerobic chamber at 37 °C (by setting the temperature of the chamber to 37 °C) in a plate stacker (BioTek BioStack 4) with 2 control plates containing uninoculated media at the top and bottom of the stack to minimize edge effects ...
-
bioRxiv - Neuroscience 2023Quote: ... After 40 hours, cells were fixed in 4% PFA and images (eGFP, mCherry and eBFP2) were acquired at cytationC10 (Biotek, Objective 60x). eGFP (interaction signal ...
-
bioRxiv - Microbiology 2023Quote: ... was recorded every 1 min over a period of 4 hours at 37°C using the Cytation 5 microplate reader (BioTek Instruments, USA).
-
bioRxiv - Synthetic Biology 2023Quote: ... The absorbance at 405 nm was measured every 1 min for at least 30 min and up to 2 h using a Synergy 4 microplate reader (Biotek, Winooski, VT). SEAP activities were calculated as a function of the increase in absorbance at 405 nm over time42.
-
bioRxiv - Neuroscience 2023Quote: ... and fluorescence emitted by Atto488 (λex = 485 nm, λem = 538 nm) was measured in a Synergy 4 plate reader (BioTek Instruments GmbH) at intervals of 10 seconds ...
-
bioRxiv - Plant Biology 2024Quote: ... Soil NH + and NO3- concentrations were analyzed in extracts from 20 g soil mixed with 80 mL 0.5M K2SO4 solution (1:4, soil: 0.5M K2SO4 solution) and measured calorimetrically at 650 nm on a µQuant microplate reader (BioTek, Winooski, VT, USA) following Sims et al ...
-
bioRxiv - Cell Biology 2022Quote: ... We also performed immunofluorescence staining for pluripotency markers in these iPSC colonies using Pluripotent Stem Cell 4-Marker Immunocytochemistry Kit (Thermo Fischer Scientific) as per manufacturer’s instruction and fluorescence were imaged using fluorescence microscopy (BioTek Lionheart LX Automated Microscope) as described previously.15 Alkaline phosphatase (ALP ...
-
bioRxiv - Cell Biology 2021Quote: ... Absorbances were obtained at 620 nm and sample concentrations were determined by comparison to the CXCL12 standards using a 4-parameter curve fit (Synergy HT & Gen5 Software, BioTek Instruments, Winooski, VT). Serum level of CXCL12 was assessed using undiluted serum isolated from the blood of tumor-bearing mice or stage IV glioma patients.
-
bioRxiv - Evolutionary Biology 2022Quote: ... and Abs750nm of all 42 plates was measured after 65h exposition (4-6 hours after light on) with an absorbance microplate reader Epoch (BioTek Instruments, VT, USA). 9 data points per well were analyzed and averaged using software Gen5 2.0 (Biotek ...
-
bioRxiv - Microbiology 2020Quote: ... on Cytation 3 (BioTek) multimode plate imager according to the manufacturer’s protocol ...
-
bioRxiv - Immunology 2022Quote: ... on Cytation 3 (BioTek). Virus concentrations that gave signal higher than 105 RLUs/well were used in neutralization experiments ...
-
bioRxiv - Microbiology 2021Quote: ... Three replicates of 150 µL of each sample was added to a 96-well plate and incubated with moderate shaking at 37°C (BioTek Synergy 4 Plate Reader) and the OD600 was measured at 30 min intervals for 16 h ...
-
bioRxiv - Molecular Biology 2024Quote: ... 2-4 images at the central callus and distal callus regions were taken using an automatic microscope (Agilent, BioTek Lionheart FX, Santa Clara, CA). Central callus regions were defined as proximal to the fracture site on either side of the bone ...
-
bioRxiv - Microbiology 2023Quote: ... We performed PCA oxidation assays either by tracking the fluorescence of reduced PCA over time in a plate reader (BioTek Synergy 4 or HTX) housed in a Coy-brand anoxic chamber or by tracking the current generated by a culture when provided PCA and an electrode poised to continuously reduce any PCA that the cells oxidized ...
-
bioRxiv - Immunology 2022Quote: ... Reactions were stopped by adding 50 μL 3M hydrochloric acid and absorbance at 492 nm was determined on a Synergy 4 plate reader (BioTek, Agilent Technologies inc., CA, USA) or similar ...
-
bioRxiv - Microbiology 2020Quote: ... UC500) and growth at 37 °C was monitored by measuring optical density at 600 nm every 15 minutes (Biotek Eon instrument with a BioStack 4). Carbon sources tested include D-glucose ...
-
bioRxiv - Biochemistry 2024Quote: The polymerization and depolymerization of pyrene–labeled recombinant WT or mutant actin (5% pyrene-labeled WT or mutant actin) was monitored as a function of increasing or decreasing pyrene– fluorescence using a Synergy 4™ microplate reader (BioTek Instruments, Winooski, VT, USA) and the built–in filter set (Excitation ...
-
bioRxiv - Microbiology 2021Quote: ... A microplate reader (BioTek Cytation 3) was used to detect the OD600 values and GFP fluorescence.
-
bioRxiv - Bioengineering 2022Quote: ... shift = 3 were measured by BioTek Cytation 5 ...
-
bioRxiv - Neuroscience 2024Quote: ... and plate stacker (Biotek Biostack 3) to automatically dispense worms suspended in CBI ...
-
bioRxiv - Evolutionary Biology 2023Quote: ... Cytation 3 (Biotek, software Gen5 v4.2).
-
bioRxiv - Cancer Biology 2021Quote: ... Day0 measurements were taken by acquiring 3×3 images with a 4x objective in Cytation5 (BioTek, USA). Cells were incubated for the subsequent 16 days and images were taken at Day4 ...
-
bioRxiv - Molecular Biology 2022Quote: ... using the Cytation 3 plate-reader (BioTek).
-
bioRxiv - Evolutionary Biology 2023Quote: ... The optical density was then measured using 6 automated plate readers (3 Epoch2 microplate reader - BioTek and 3 Synergy microplate reader - BioTek) simultaneously ...
-
bioRxiv - Cancer Biology 2023Quote: ... Plates were imaged using the Cytation 3 (BioTek) and cells were counted using CellProfiler ...
-
bioRxiv - Cancer Biology 2021Quote: ... on a Cytation 3 Imaging Multi-Mode Reader (BioTek). Oxaliplatin IC50 values were calculated using curve-fitting in Prism (v.9.0.0) ...
-
bioRxiv - Microbiology 2021Quote: ... Samples were imaged with a Cytation 3 imager (BioTek) and images were analyzed in CellProfiler v3.1.9.
-
bioRxiv - Biochemistry 2021Quote: ... A Cytation 3 Cell Imaging Multi-Mode Reader (BioTek) was used to the ThT fluorescence produced ...
-
bioRxiv - Microbiology 2022Quote: ... Images were acquired using a Cytation 3 imager (BioTek), and analyzed using custom FIJI macros to count the number of parasites and host-cell nuclei (49) ...
-
bioRxiv - Biochemistry 2023Quote: ... A Cytation 3 Cell Imaging Multi-Mode Reader (BioTek) was used to collect light generated by Renilla or firefly.
-
bioRxiv - Molecular Biology 2024Quote: ... using Cytation 3 Imaging Reader (BioTek, Winooski, VT, USA). Final results were obtained from Δ OD (570–690 ...
-
bioRxiv - Neuroscience 2022Quote: ... Wells were washed 3 x with PBS and fluorescent microscopy was achieved using the Cytation 3 Cell Imaging Multi-Mode Reader (BioTek, Gen5 v2 software), with a combination of 375 nm ...
-
bioRxiv - Molecular Biology 2020Quote: Cytation 3 Multi-Mode plate reader from BioTek (Winooski, VT) was used for DNA binding assay ...
-
bioRxiv - Microbiology 2020Quote: ... and 3 dpi by high content imaging (BioTek Cytation 5) configured with brightfield and GFP cubes ...
-
bioRxiv - Microbiology 2020Quote: ... and other bacteria were obtained on a Cytation 3 (Biotek) at 37 °C ...
-
bioRxiv - Cancer Biology 2021Quote: ... fluorescence polarization readings were recorded using a Cytation 3 (Biotek) multi-mode imager with fluorescence polarization filter prior to adding 1mM NAD+ and every 5 minutes after ...
-
bioRxiv - Bioengineering 2020Quote: ... using a Cytation 3 microplate reader (Biotek®, Vermont,USA). All assays were conducted in triplicate ...
-
bioRxiv - Neuroscience 2023Quote: ... Fluorescence was measured using a Cytation™3 reader (BioTek).
-
bioRxiv - Neuroscience 2024Quote: ... Fluorescence was measured using the multiplate reader Cytation 3 (BioTek) at 531 nm (excitation ...
-
bioRxiv - Neuroscience 2024Quote: ... The Cytation 3 Cell Imaging Multi-mode Plate Reader (BioTek) was used to measure the emitted light ...
-
bioRxiv - Microbiology 2024Quote: ... Images were captured on a Cytation 3 plate reader (BioTek) using the green ...
-
bioRxiv - Immunology 2024Quote: ... Fluorescent (EGFP) images were captured using the Cytation 3 (BioTek) with a 4x objective ...
-
bioRxiv - Molecular Biology 2020Quote: ... with the Cytation 3 imaging plate reader (BioTek, Winooski, VT, USA). Samples were diluted to 200 μM ...
-
bioRxiv - Immunology 2021Quote: ... Plates were read using a spectrophotometer (BioTek Instruments Inc., Cytation 3) reading at 450nm ...
-
bioRxiv - Cell Biology 2021Quote: ... and measured using Cytation 3 Cell Imaging Multi-Mode Reader (BioTek). Graphs were plotted and significance was assessed using Graphpad Prism.
-
bioRxiv - Bioengineering 2022Quote: ... Luminescence was measured by the Cytation 3 plate reader (BioTek, VT) with fresh culture medium as a blank control.
-
bioRxiv - Cancer Biology 2022Quote: ... and luminescence was measured with Cytation 3 Multi-Mode Reader (Biotek).
-
bioRxiv - Biochemistry 2022Quote: ... luciferase activities were measured in Cytation 3 multi-mode reader (BioTek) by quickly mixing 2 μL of above refolding mixture with 50 μL of luciferase substrate (Promega) ...