Labshake search
Citations for Sutter Instruments :
51 - 62 of 62 citations for Vertical Electrophoresis system since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2019Quote: ... Optogenetic stimulation of ChR2-expressing RGC axons was accomplished with a 460 nm full field flash generated by a TLED system (Sutter Instruments) and delivered through the microscope objective ...
-
bioRxiv - Neuroscience 2022Quote: ... Imaging was performed using a custom-built microscope using MIMMS (Modular In vivo Multiphoton Microscopy System) components (Sutter Instruments; Novato, CA) and a Chameleon Discovery NX tunable femtosecond laser (Coherent ...
-
bioRxiv - Neuroscience 2023Quote: ... We controlled focus and the axial position of the objective using a micromanipulator system (Sutter Instrument, MPC-200 and ROE-200). We set the laser to 920 nm when collecting images from animals expressing GCaMP ...
-
bioRxiv - Neuroscience 2022Quote: ... 10-20 ms pulses of blue light (460 nm) were used to activate ChR2 with a Lambda 421 optical beam combiner system (Sutter instruments) illuminating area of interest through microscope objective lens ...
-
bioRxiv - Cell Biology 2023Quote: ... the XY position was controlled inside the microscopy chamber using a micro-positioning system (MP-285, Sutter Instrument, Novato, CA, USA). GFP-LRRK2 was added to the observation chamber before tube pulling at the concentrations indicated in each panel ...
-
bioRxiv - Neuroscience 2023Quote: Two-photon calcium imaging was performed with a custom-built microscope (MIMMS, Modular In vivo Multiphoton Microscopy System, components, Sutter Instruments; controlled by ScanImage ...
-
bioRxiv - Neuroscience 2024Quote: ... Fura-2 was excited at 340 and 380 nm (excitation time 60 ms) with a rapid switching monochromator (TILL Photonics) or an LED-based system (Lambda OBC, Sutter Instruments). Mean fluorescence intensity ratios (F340/F380 ...
-
bioRxiv - Neuroscience 2022Quote: 2-photon calcium imaging was conducted using a custom microscope based on MIMMS (Modular In vivo Multiphoton Microscopy System, e.g. Kerlin et al., 2019) components (Sutter Instruments, Novato, CA) with a Chameleon Discovery NX tunable femtosecond laser (Coherent ...
-
bioRxiv - Bioengineering 2020Quote: ... exposes the capillary’s region of interest under the photomask through a light guide with a collimator (Adjustable Spot Collimating Adaptor, Excelitas Technologies, MA, USA) and a light shutter (Lambda SC, Smart Shutter control system, Sutter Instrument, CA, USA) attached at its end ...
-
bioRxiv - Cell Biology 2020Quote: ... Ratiometric images of Ca2+ signals were obtained using a microscope (Axio Observer, Zeiss) equipped with a Lambda DG4 illumination system (Sutter Instrument Company, Novato, CA) as previously described (Philippe et al. ...
-
bioRxiv - Neuroscience 2023Quote: ... Ca2+ imaging recordings were obtained using a Zeiss microscope equipped with a MicroMax RS camera (Roper Scientific Inc. Tuscon, AZ) and a Lambda 10-2 optical control system (Sutter Instrument Co. Novato, CA). Excitation from a monochromator was set at 340 nm and 380 nm with a 510 nm emission filter and the cellular fluorescence was imaged with a 10x objective (Zeiss) ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipette electrodes with a resistance of 5-9 MOhm were pulled from borosilicate glass (Multi Channel Systems; Cat.nr. 300034) using a horizontal puller (Sutter instrument CO. Model P-2000). The intra-pipette solution included (in mM) ...