Labshake search
Citations for Sutter Instruments :
1 - 50 of 115 citations for Mouse Anti Canine Distemper Virus Surface Envelope Antibody 8 1 since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2022Quote: ... Virus-containing solution was slowly injected (1-2 nl/sec) through a quartz pipette (pulled on P2000, Sutter instruments,) using a Nanoject 3 system (Drummond Scientific Company ...
-
bioRxiv - Neuroscience 2022Quote: ... Injection of 1 – 1.5 μl of virus suspension (mixed with fast green, 1:20) was performed in the scale tympani using laser-pulled (P-2000, Sutter Instrument Inc., USA) quartz capillaries (Science Products ...
-
bioRxiv - Neuroscience 2024Quote: Whole-cell voltage- and current-clamp recordings were obtained from mouse DRG neurons or transiently transfected HEK293 cells with borosilicate glass patch-pipettes (Sutter Instruments, 4-8 MΩ resistance) and were performed simultaneously with temperature recordings ...
-
bioRxiv - Neuroscience 2023Quote: ... The EAr was lowered onto the surface of the exposed brain using a motorized manipulator (MP200; Sutter instruments). The dorsoventral coordinates were marked using the depth of the electrode targeting the PVN (AP= -1 mm ...
-
bioRxiv - Neuroscience 2019Quote: ... Electrodes were inserted perpendicular to the surface of the cortex using a micro-manipulator (MP-225, Sutter Instrument Company). Cortical penetration depth was tracked using micro-manipulator coordinates with the tip of the electrode being inserted between 900 μm to 1450 μm (mean of 1256 μm ± 157 μm ...
-
bioRxiv - Neuroscience 2020Quote: ... AAV virus (300nL volume) was then pressure injected 100nL/min via a glass pipette pulled (P-97 Sutter Instruments) from borosilicate capillaries (Drummond calibrated 5ul ...
-
bioRxiv - Neuroscience 2022Quote: ... Virus was injected slowly with a hydraulic manipulator (Narashige, MO-10) through a glass micropipette (pulled using Sutter Instrument P-97 ...
-
bioRxiv - Neuroscience 2023Quote: For virus injections, borosilicate glass capillaries (cat. no. 1408472, Hilgenberg) were pulled on a P-97 micropipette puller (Sutter Instruments), broken to a tip diameter of Ø40–50 µm ...
-
bioRxiv - Neuroscience 2021Quote: ... A 16-channel silicon probe (NeuroNexus) was lowered into HVC (between 300-700 μm from the dorsal surface) using a micromanipulator (Sutter Instruments). Neural activity was digitized at a sampling rate of 30 kHz on an Intan RHD2132 headstage and acquired with an RHD Recording Controller (Intan Technologies) ...
-
bioRxiv - Neuroscience 2020Quote: ... the oxygen microelectrode was positioned perpendicular to the brain surface and advanced into the cortex with a micromanipulator (MP-285, Sutter Instrument). Measurement site was chosen to avoid large pial vessels ...
-
bioRxiv - Neuroscience 2019Quote: ... the oxygen microelectrode was positioned perpendicular to the brain surface and advanced into the cortex with a micromanipulator (MP-285, Sutter Instrument). The depth zero was defined as when the tip of the oxygen microelectrode touches the brain surface under visual inspection ...
-
bioRxiv - Neuroscience 2023Quote: ... The reference and ground wires were inserted into their respective burr holes and the EAr was lowered onto the surface of the exposed brain using a motorized manipulator (MP200; Sutter Instruments). The dorsoventral coordinates were estimated using the depth of the electrode targeting the PVN (AP = −1 mm ...
-
bioRxiv - Neuroscience 2019Quote: ... Patch pipettes (5-8 MΩ) were pulled (P-87 puller, Sutter Instruments) from borosilicate glass capillaries (Science Products ...
-
bioRxiv - Neuroscience 2021Quote: ... The array was advanced slowly to a depth of 200-350 um from the surface into the ACx using a micromanipulator (MP-285, Sutter Instrument Company). The electrodes were allowed to settle for 15-20 min before the stimulus presentation was started ...
-
bioRxiv - Neuroscience 2023Quote: ... Glass micropipettes were fabricated from borosilicate glass capillaries (8-9 MΩ; Sutter Instruments) with the use of a horizontal puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2021Quote: ... L2/3 responses were probed between 200-300 microns from the cortical surface using a micromanipulator (MP-285, Sutter Instrument Company, Novato, CA). Signals were acquired after passing through unity gain (1x ...
-
bioRxiv - Neuroscience 2020Quote: ... pulled to 7-8 MΩ using a horizontal puller P-97 (Sutter Instrument, US) and fire polished to 9-12 MΩ ...
-
bioRxiv - Cell Biology 2021Quote: ... were pulled to resistances of 5 - 8 MΩ (P-2000; Sutter Instruments, Novato CA). The standard pipette solution contained (in mM) ...
-
bioRxiv - Molecular Biology 2024Quote: ... with a Flaming-Brown P-97 puller (Sutter Instruments; tip resistance 5–8 MΩ). The pipette solution contained (in mM) ...
-
bioRxiv - Neuroscience 2019Quote: ... The array was advanced slowly to a depth of 1800 um from the surface (Fig. 1A) into the OFC using a micromanipulator (MP-285, Sutter Instrument Company, Novato, CA). The electrodes were allowed to settle for >20 min before the stimulus presentation was started ...
-
bioRxiv - Neuroscience 2020Quote: ... 8-12 MΩ thick-walled borosilicate electrodes (BF150-86-10HP, Sutter Instrument Company, Novato, CA) were pulled with a P-97 Brown/Flaming Puller (Sutter Instrument Company ...
-
bioRxiv - Neuroscience 2023Quote: ... The pipette (6-8 MΩ) was pulled by a micropipette puller (P-1000, Sutter instrument) and filled with the internal solution that contained (in mM) ...
-
bioRxiv - Neuroscience 2020Quote: ... were pulled to tip resistances of 5-8 M Ώ using a multi-stage puller (Sutter Instruments) and were filled with K-gluconate based intracellular solution ...
-
bioRxiv - Neuroscience 2024Quote: ... Patch electrodes were pulled to tip resistances of 5-8 MΩ using a multistage puller (Sutter Instruments) and were filled with intracellular solution ...
-
Neuron-astrocyte metabolic coupling facilitates spinal plasticity and maintenance of persistent painbioRxiv - Neuroscience 2022Quote: ... Electrodes (4–8 MΩ) were pulled from borosilicate glass capillaries (O.D. 1.5 mm, I.D. 0.86 mm, Sutter Instruments, USA). Intrinsic firing properties of lamina 1 neurons were recorded in the presence of 10 mM CNQX ...
-
bioRxiv - Neuroscience 2020Quote: ... Patch pipettes (resistance, 8–10 MΩ) were pulled from 1.5 mm thin-walled borosilicate glass (Sutter Instruments, Novato, CA) on a horizontal puller (model P-97 ...
-
bioRxiv - Neuroscience 2021Quote: ... Patch pipettes (resistance, 8-10 MΩ) were pulled from 1.5 mm thin-walled borosilicate glass (Sutter Instruments, Novato, CA) on a horizontal puller (model P-97 ...
-
bioRxiv - Neuroscience 2021Quote: ... Borosilicate pipettes of 5 – 8 MOhm resistance were pulled with a Flaming / Brown micropipette puller P-1000 (Sutter instruments). All recordings were done in current clamp with an intracellular solution containing 130 mM K-gluconate ...
-
bioRxiv - Neuroscience 2022Quote: ... Glass micropipettes (4-8 MΩ) were pulled using a P-1000 micropipette puller (Sutter Instruments, Novato, California, United States). Whole-cell current-clamp recordings were low-pass filtered at 10 kHz and digitized at 20 kHz ...
-
bioRxiv - Neuroscience 2020Quote: ... The patch pipettes were pulled to yield an impedance of 6–8 MΩ on a horizontal pipette puller (Sutter Instrument) from thin-walled ...
-
bioRxiv - Neuroscience 2020Quote: ... World Precision) to obtain pipette resistance ranging from 5 – 8 MΩ using next generation micropipette puller (P-1000, Sutter Instrument). External solution is consist of 140 mM NaCl ...
-
bioRxiv - Neuroscience 2023Quote: ... Recording pipettes with a tip resistance of 8-12 MΩ were made of borosilicate capillaries (Sutter Instruments, Novato, CA, USA) and filled with intracellular solution containing (in mM) ...
-
bioRxiv - Neuroscience 2023Quote: ... Whole-cell recordings were obtained using 8-12 MΩ pipettes pulled from borosilicate glass by a puller (P97, Sutter Instruments), with an in-pipette solution containing 122.5 mM K-glucose ...
-
bioRxiv - Neuroscience 2023Quote: Patch pipette of 5-8 MΩ tip resistance were fabricated from borosilicate glass by using a microelectrode puller (Sutter Instruments). The initial access resistance was 18.2±0.5 MΩ for current-clamp recordings (n=21 ...
-
bioRxiv - Neuroscience 2021Quote: ... Electrophysiology recordings were made using SutterPatch 7/8 software utilizing Sutter Integrated Patch Clamp Amplifier and Data Acquisition System (Sutter Instruments). Pipette solution contained (in mM) ...
-
bioRxiv - Microbiology 2022Quote: ... 40 cm long fused silica analytical column with an integrated spray tip (6 – 8 μm-diameter opening, pulled on a P-2000 laser puller from Sutter Instruments). The analytical column was packed with 1.9 μm-diameter Reprosil-Pur C-18-AQ beads (Dr ...
-
bioRxiv - Systems Biology 2019Quote: ... 75 μm inner diameter fused silica analytical column with an integrated spray tip (6-8 μm diameter opening, pulled on a P-2000 laser puller from Sutter Instruments). The trap column was packed with 5 μm Aqua C-18 beads (Phenomenex ...
-
bioRxiv - Biochemistry 2019Quote: ... 75 µm-inner diameter fused silica analytical column with an integrated spray tip (6-8 µm diameter opening, pulled on a P-2000 laser puller from Sutter Instruments). The trap column is packed with 5 µm Aqua C-18 beads (Phenomenex ...
-
bioRxiv - Evolutionary Biology 2020Quote: ... 75-μm-inner diameter fused silica analytical column with an integrated spray tip (6-8-μm-diameter opening, pulled on a P-2000 laser puller, Sutter Instruments). The trap column is packed with 5 μm Aqua C18 beads (Phenomenex ...
-
bioRxiv - Molecular Biology 2020Quote: ... was used together with a fused silica spraying capillary pulled to a tip diameter of 8-10 um using a P-2000 capillary puller (Sutter Instruments). The capillary tubing (75 µm I.D. ...
-
bioRxiv - Neuroscience 2024Quote: ... Borosilicate glass pipettes (Hilgenberg) of 6 - 8 MOhm resistance were pulled with a Flaming / Brown micropipette puller P-1000 (Sutter Instruments). The intracellular solution contained 130 mM K-gluconate ...
-
bioRxiv - Neuroscience 2020Quote: ... whole-cell patch-clamp recordings were obtained at the soma under 60x magnification in BGMT neurons from control and 6-OHDA-lesioned mice with glass pipettes (at resistances 4-8 MΩ) pulled from 1.5 mm OD borosilicate glass on a Sutter P-97 puller (Sutter Instruments, Novato, CA).
-
bioRxiv - Neuroscience 2023Quote: ... Whole-cell patch-clamp recordings were then conducted at RT using pipettes with resistances typically ranging from 6-8 MΩ (P-2000, Sutter Instruments, USA). The pipette solution consisted of the following concentrations (in mM) ...
-
bioRxiv - Neuroscience 2023Quote: ... Neurons were patched with a borosilicate glass pipette (8-12 MΩ) pulled using a Sutter P-97 Flaming Brown puller (Sutter Instrument Company) and filled with an internal solution consisting of ...
-
bioRxiv - Molecular Biology 2023Quote: ... 20 cm length) with a 5 to 8 μm tip opening generated using a laser puller (Sutter Instrument Co, model P-2000). Samples were loaded onto the LC using an autosampler at 800 nl/min and eluted at 400 nl/min over a 90-minute gradient with solvent composition rising from 2% to 35% acetonitrile with 0.1% formic acid ...
-
bioRxiv - Cancer Biology 2019Quote: ... 75 μm inner diameter spraying capillary pulled to a tip diameter of approximately 8-10 µm using a P-2000 capillary puller (Sutter Instruments, Novato, CA). The 160mm separation column was packed with ReproSil-Pur 120 C18-AQ ...
-
bioRxiv - Neuroscience 2020Quote: ... Patch pipettes (4-8 MΩ) were pulled from thin wall borosilicate glass (G150TF-3, Warner Instruments) with a micropipette puller (P-87, Sutter Instruments, Novato, CA) and filled with a potassium gluconate-based intracellular solution containing either (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... Patch pipettes (4–8 MΩ) were pulled from thin wall borosilicate glass (G150TF-3, Warner Instruments) using a micropipette puller (P-87, Sutter Instruments, Novato, CA) and filled with a KGlu based intra-pipette solution containing (in mM) ...
-
bioRxiv - Neuroscience 2022Quote: ... Patch pipettes (4–8 MΩ) were pulled from thin wall borosilicate glass (G150TF-3, Warner Instruments) using a micropipette puller (P-87, Sutter Instruments, Novato, CA) and filled with a potassium gluconate (KGlu)-based intrapipette solution containing (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... using glass pipette (4-8 MΩ) pulled from thick-walled borosilicate glass capillaries with a micropipette puller (Model P-97; Sutter Instrument, Novato, CA, USA) as before (Dabrowska et al. ...