Labshake search
Citations for Sutter Instruments :
1 - 50 of 74 citations for Mouse 60S ribosomal protein L22 like 1 RPL22L1 ELISA Kit since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2019Quote: ... impedance: 60–120 MΩ) pulled with the P-2000 puller (Sutter Instruments) penetrating the brain under an angle of 15° (2.0 posterior to bregma ...
-
bioRxiv - Biophysics 2023Quote: ... After a quartz capillary 1.2 mm in diameter (Q120-60-7.5; Sutter Instruments, Novato, CA, USA) had been tapered with an electrode puller (P-2000 ...
-
bioRxiv - Neuroscience 2021Quote: ... We used quartz-glass capillaries with filament (O.D. 1.0 mm, I.D. 0.6 mm; QF100-60-10; Sutter Instrument). Pipettes were pulled using a P-2000 Sutter Instrument Puller ...
-
bioRxiv - Neuroscience 2024Quote: Hair bundles were deflected with a rigid probe (pulled glass pipette, BF120-60-10, Sutter instrument Company) glued to a piezoelectric bimorph ceramic and brought into contact with the staircase of stereocilia (‘back’ of the bundle ...
-
bioRxiv - Neuroscience 2020Quote: ... we used sharp glass microelectrodes (BF120-60-10; shaped with a P-97 Brown/Fleming pipette puller, Sutter Instruments), which allowed penetrating the retina with little damage and provided for fairly long recordings (∼0.5-2 hours) ...
-
Individual kinetochore-fibers locally dissipate force to maintain robust mammalian spindle structurebioRxiv - Cell Biology 2019Quote: ... it was moved in a direction that is roughly perpendicular (∼60°-90°) from the spindle’s long axis using software (Multi-Link, Sutter Instruments). We wrote a custom program to take as inputs the desired angle ...
-
bioRxiv - Neuroscience 2024Quote: ... Fura-2 was excited at 340 and 380 nm (excitation time 60 ms) with a rapid switching monochromator (TILL Photonics) or an LED-based system (Lambda OBC, Sutter Instruments). Mean fluorescence intensity ratios (F340/F380 ...
-
bioRxiv - Neuroscience 2019Quote: ... Glass pipettes were pulled to obtain a tip size of approximately 40-60 μm on a pipette puller (Sutter Instrument Co., P-97). Viruses were infused into target regions at approximately 100 nl/min using a syringe pump (Harvard Apparatus ...
-
bioRxiv - Neuroscience 2022Quote: We recorded light stimulus-evoked Ca2+ signals in GCL cells of the explanted mouse retina using a MOM-type twophoton (2P) microscope (74, 75) from Sutter Instruments (purchased from Science Products ...
-
bioRxiv - Neuroscience 2023Quote: ... was estimated by focusing up using a calibrated micromanipulator to move the microscope relative to the mouse (MP-285, Sutter Instrument). In LEC ...
-
bioRxiv - Microbiology 2020Quote: ... This vector and its product was targeted as the main contamination tracer in this study via PCR of vector sequences and macro-photography of the mNeonGreen protein fluorescence under 470 nm wavelength using a xenon arc lamp (Sutter Instruments; California, USA).
-
bioRxiv - Neuroscience 2024Quote: Whole-cell voltage- and current-clamp recordings were obtained from mouse DRG neurons or transiently transfected HEK293 cells with borosilicate glass patch-pipettes (Sutter Instruments, 4-8 MΩ resistance) and were performed simultaneously with temperature recordings ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... Approximately 1-3 µL of protein solution was loaded into glass emitters that were made in-house using borosilicate capillaries and a micropipette puller (Sutter Instruments Model P-97, Novato, CA). A platinum wire was inserted into the solution and approximately 0.5-1 kV was applied to the wire to generate ions ...
-
bioRxiv - Developmental Biology 2024Quote: ... and 1 mm (BF200-100-10, SUTTER INSTRUMENTS) for 70 days old coricOs.
-
bioRxiv - Cell Biology 2020Quote: Solid borosilicate glass rods 1 mm in diameter (Sutter Instruments) were pulled into a needlepoint with a Brown-Flaming type micropipette puller (Sutter P-87) ...
-
bioRxiv - Neuroscience 2024Quote: ... standard-wall (1 mm outer diameter) borosilicate capillaries (Sutter Instrument) were pulled to resistances between 5–16 MΩ using a micropipette puller (Flaming/Brown ...
-
bioRxiv - Neuroscience 2021Quote: ... 0.5-1 μL per point) with sharpened glass pipettes (Sutter Instrument), self-made to have a bevel of 35° and an opening of 20-μm diameter at the tip (64) ...
-
bioRxiv - Cell Biology 2020Quote: Glass capillaries (0.75mm inner diameter, 1 mm outer diameter; Sutter Instrument) were forged into glass needles by pulling them on a vertical pipette puller (Narishige PC-10) ...
-
bioRxiv - Cancer Biology 2023Quote: Borosilicate glass capillaries (O.D.: 1 mm, I.D.: 0,75 mm, Sutter Instrument) were pulled using glass micropipette puller (Sutter Instrument) ...
-
bioRxiv - Neuroscience 2019Quote: ... glass microelectrodes with 1-micron tips were pulled (Sutter Instruments, Borosilicate Glass with filament) and filled with 2M NaCl (resistance 1-2 MΩ) ...
-
bioRxiv - Neuroscience 2022Quote: ... glass capillary tubes (GD-1; Narishige) were pulled using a micropipette puller (Sutter Instruments). Embryos were injected into the lateral ventricle with 1 microliter of DNA solution (expression plasmids other than pCAG-tTA2s ...
-
bioRxiv - Neuroscience 2020Quote: ... pulled to 1-3MΩ-tip resistance using a P-97 puller (Sutter Instruments, CA). For recordings ...
-
bioRxiv - Biochemistry 2021Quote: ... with an emitter tip pulled to approximately 1 µm using a laser puller (Sutter Instruments). Peptides were loaded on-column at a flow-rate of 400nL/min for 30 minutes and then eluted over 120 min at a flow-rate of 300 nl/minute with a gradient of 2-30% acetonitrile in 0.1% formic acid ...
-
bioRxiv - Biochemistry 2021Quote: ... Quartz capillaries (o.d. 1 mm, i.d. 0.5mm, length 7.5 cm were purchased from Sutter Instruments.
-
bioRxiv - Biochemistry 2021Quote: ... Quartz capillaries (o.d. 1 mm, i.d. 0.5mm, length 7.5 cm were purchased from Sutter Instruments, Germany.
-
bioRxiv - Neuroscience 2022Quote: ... Glass micropipettes (O.D. 1 mm, I.D. 0.5 mm Sutter Instruments, cat no. BF100-50-10) pulled by using a P1000 pipette puller (Shutter Instruments ...
-
bioRxiv - Cell Biology 2022Quote: ... with 1 mm inner diameters using a Flaming-Brown Micropipette Puller (Sutter Instrument, Novato, CA). Pulled tips were cut with ceramic tile to final inner diameter 50-100 µm ...
-
bioRxiv - Neuroscience 2021Quote: ... Germany. Quartz capillaries (o.d. 1 mm, i.d. 0.5mm, length 7.5 cm) were purchased from Sutter Instruments. Water used in the experiments was deionised in house using a Millipore column and had a resistivity of 18MΩ.
-
bioRxiv - Biophysics 2022Quote: Micropipettes made of borosilicate capillaries (ID =0.78 mm, OD = 1 mm, B100-75-15, Sutter Instrument) were formed using a puller (P-1000 ...
-
bioRxiv - Developmental Biology 2022Quote: ... Dissection was carried out by means of pulled borosilicate rods (1 mm of diameter, Sutter instrument) pulled using a P97 filament-based pipette puller (Sutter instrument ...
-
bioRxiv - Neuroscience 2019Quote: ... Patch pipettes of 1-3 MΩ resistance pulled from borosilicate capillary glass (Sutter Instrument, Novato, CA) with a Sutter P-97 horizontal puller ...
-
bioRxiv - Neuroscience 2022Quote: ... was slowly inserted (0.1 mm per 1 minute) using motorized micromanipulator (MP-225; Sutter Instrument Co.) into the cerebellum with the tip reaching depth of 3-5.5 mm below the brain surface ...
-
bioRxiv - Neuroscience 2023Quote: ... Slices were maintained at 24±1 °C using a dual TC344B temperature control system (Sutter Instruments). S1HL slices were continuously perfused with oxygenated (95%O2/ 5%CO2 ...
-
bioRxiv - Developmental Biology 2021Quote: The glass capillary tubing (OD=1 mm, ID=0.58 mm, length=7.5 cm) was pulled (Sutter instruments Co. ...
-
bioRxiv - Biochemistry 2021Quote: ... monosodium phosphate (NaH2PO4). Quartz capillaries (o.d. 1 mm, i.d. 0.5mm, length 7.5 cm) were purchased from Sutter Instruments. Deionised (Millipore ...
-
bioRxiv - Neuroscience 2019Quote: ... Patch electrodes (2–4 MΩ) were pulled from borosilicate capillary glass of external diameter 1 mm (Sutter Instruments) using a Flaming/Brown micropipette puller (model P-2000 ...
-
bioRxiv - Neuroscience 2021Quote: Patch electrodes (2–3□MΩ) were pulled from borosilicate capillary glass of external diameter 1□mm (Sutter Instruments) using a Flaming/Brown micropipette puller (model P-2000 ...
-
bioRxiv - Biochemistry 2020Quote: ... C18 beads (Waters BEH) and an emitter tip pulled to approximately 1 μm using a laser puller (Sutter Instruments) was used for HPLC separation of peptides ...
-
bioRxiv - Biophysics 2022Quote: We pulled Nanocapillaries from 7.5 cm long quartz capillaries with 0.7 mm inner diameter and 1 mm outer diameter (QF100-70-7.5, Sutter Instruments) using a laser puller (P-2000 ...
-
bioRxiv - Neuroscience 2022Quote: ... Virus-containing solution was slowly injected (1-2 nl/sec) through a quartz pipette (pulled on P2000, Sutter instruments,) using a Nanoject 3 system (Drummond Scientific Company ...
-
bioRxiv - Biophysics 2024Quote: ... it was screwed through two M6 screws (Figure 1, SI_Figure 1A and SI_Figure 3A) to a right-angle adaptor plate (3DMS-3X3, Sutter Instruments) mounted on a micromanipulator (MP-285 ...
-
bioRxiv - Neuroscience 2021Quote: ... was pulled to create a 7 to 15 MΩ electrode with a 1 to 1.5 µm tip using a Model P-1000 Micropipette puller (Sutter Instruments). Intracellular saline83 was composed of 140 mM potassium-aspartate ...
-
bioRxiv - Cancer Biology 2022Quote: Transplantation needles were prepared from borosilicate glass capillaries (Outer Diameter: 1 mm, Inner Diameter: 0.75 mm, 10 cm length, Sutter Instrument), lacking the internal filament ...
-
bioRxiv - Developmental Biology 2022Quote: ... pipettes were prepared by pulling 15 cm long borosilicate capillaries (outer diameter: 1 mm, inner diameter: 0.58 mm, Sutter Instruments), using a filament-based pipette puller (P-97 Sutter Instruments) ...
-
bioRxiv - Cell Biology 2023Quote: ... Injection pipettes consisted of borosilicate glass capillaries (1 mm in diameter) pulled with a needle puller (P-1000; Sutter Instruments) and ground with a 30° angle on a needle beveler (BV-10 ...
-
bioRxiv - Neuroscience 2022Quote: ... Warner Instruments) and pulled to 1-1.5 μm tip diameter using a Flaming Brown P-97 pipette puller (Sutter Instruments), such that their resistance when backfilled with external solution was approximately 7-10 MΩ ...
-
bioRxiv - Neuroscience 2023Quote: ... A borosilicate-glass recording electrode filled with recording ACSF (1–2 MΩ ; Model P-97, Sutter Instruments, Novato, CA, USA) was placed in the stratum radiatum area to record field excitatory postsynaptic potentials (fEPSPs ...
-
bioRxiv - Neuroscience 2021Quote: ... Somatic whole-cell patch-clamp recordings were performed using pipettes pulled from borosilicate glass capillaries (2 mm outer/1 mm inner diameter) on a horizontal puller (P-97, Sutter Instrument). The pipettes were filled with an intracellular solution containing the following (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... a glass micropipette (1 - 2 µm in diameter of the tip open) made from borosilicate glass capillaries (BF100-58-10, Sutter Instrument) was inserted from the surgery site and the tip was placed around the pretectum area ...
-
bioRxiv - Neuroscience 2019Quote: ... Recordings were performed with artificial hemolymph-filled glass microelectrodes (1/0.58 mm outer/inner diameter) that were pulled with a micropipette puller (P-2000, Sutter Instrument CO) to get a tip resistance of 5 to 10 MOhm and which were then broken to get a tip resistance of 1.3 – 3.5 MOhm ...