bioRxiv - Bioengineering 2022Quote: Aluminosilicate glass micropipettes with a long tether were prepared using a P-97 micropipette puller (Sutter Instruments). The pulled pipettes were cut 3-5 mm from the tip to get 10-25 µm diameter pipettes with jagged ends ...
-
bioRxiv - Physiology 2022Quote: ... Warner Instrument-multi channel system distributer) and pulled using a micropipette puller (Sutter Instruments, model P-97). Pipette tips were then fire polished and had a resistance ranging from 4 to 6 MΩ ...
-
bioRxiv - Physiology 2019Quote: ... Micropipettes were pulled on a P-97 Flaming-Brown pipette puller (Sutter Instruments Co., Novato, CA, USA) from 1.5 mm borosilicate glass (World Precision Instruments Inc. ...
-
bioRxiv - Neuroscience 2019Quote: ... Recording electrodes were pulled from thick-wall glass pipet (O.D. 1.5mm, I.D. 0.86mm) using P-97 puller (Sutter Instruments) and fire-polished to resistances of 10–15 Mω ...
-
bioRxiv - Neuroscience 2020Quote: Borosilicate glass patch pipettes were pulled using a micropipette puller (P-97, Sutter Instruments, Novato, CA, USA). For recoding ...
-
bioRxiv - Neuroscience 2020Quote: ... Recording pipettes (KG33, King Precision Glass) were pulled in a horizontal pipette puller (P-97, Sutter Instruments) with a tip resistance of 3–5 MΩ ...
-
bioRxiv - Bioengineering 2021Quote: ... were made using a glass puller and filament (P-97 and FB315B, Sutter Instrument Co., Novato, CA) under the following settings ...
-
bioRxiv - Neuroscience 2021Quote: ... Patch pipettes were pulled from borosilicate glass with a P-97 horizontal puller (Sutter Instrument, Novato, CA), and fire-polished using a microforge (MF 83 ...
-
bioRxiv - Neuroscience 2023Quote: ... Glass electrodes were pulled using a Flaming Brown Model P-97 micropipette puller (Sutter Instrument, CA, USA). Recordings were made using an Axoclamp 2 B amplifier with HS-2A x0.1 head stage (Molecular Devices ...
-
bioRxiv - Neuroscience 2022Quote: ... pipette tip diameter: 2 μm) were pulled from borosilicate glass using a P-97 puller (Sutter Instruments) and filled with intracellular solution (containing in mM ...
-
bioRxiv - Neuroscience 2023Quote: ... A microinjection needle (1.7 μm diameter tip) was prepared on a micropipette puller (P-97, Sutter Instrument) and backfilled with 50 μM STX-bpc for injection of a small bolus ...
-
bioRxiv - Animal Behavior and Cognition 2023Quote: ... A microinjection needle (1.7 μm diameter tip) was prepared on a micropipette puller (P-97, Sutter Instrument) from a borosilicate glass capillary (1B150F-4 ...
-
bioRxiv - Developmental Biology 2023Quote: Long and very thin injecting needles were done in an electrophysiology puller (Sutter instruments model P-97) with the following protocol ...
-
bioRxiv - Neuroscience 2023Quote: ... patch electrodes were pulled from borosilicate glass capillaries by a pipette puller (Model P-97; Sutter Instruments), with the program parameters tuned to produce an electrode resistance around 6 MΩ ...
-
bioRxiv - Neuroscience 2024Quote: ... The solution was loaded through borosilicate glass micropipettes pulled by a micropipette puller (P-97, Sutter Instrument).
-
bioRxiv - Physiology 2024Quote: ... were prepared using a Sutter P-97 Flaming Brown pipette puller (Sutter Instruments, San Raffael, CA, USA). The ion-selective microelectrodes were silanized using N ...
-
bioRxiv - Neuroscience 2024Quote: ... Patch pipettes were pulled with a micropipette Puller P-97 Flaming/Brown (Sutter Instrument, Novato, CA, USA) and fire polished with a Micro forge MF-830 ...
-
bioRxiv - Neuroscience 2019Quote: ... Patch pipettes (3 - 5 MΩ) were pulled using a Brown/Flaming P-97 micro pipette puller (Sutter Instruments). Slices were perfused with oxygenated recording solution (~2ml/min ...
-
bioRxiv - Neuroscience 2021Quote: ... a glass capillary (30-0067, Harvard Apparatus pulled by a Brown Micropipette puller, Model P-97, Sutter Instruments) was introduced at a 5° angle into cisterna magna (7.5 mm distal to the occipital bone and 1.5 mm lateral to the muscle-midline) ...
-
bioRxiv - Neuroscience 2020Quote: ... thin-walled glass capillaries (Sutter Instruments in five stages on a micropipette puller (model P-97; Sutter Instruments). Internal solution contained the following ...
-
bioRxiv - Biophysics 2021Quote: ... Borosilicate glass patch pipettes of 3-5 MΩ were formed using a micropipette puller (Sutter Instruments, P-97) and then coated with Sylgard 184 silicone (Dow Corning) ...
-
bioRxiv - Neuroscience 2022Quote: ... fire-polished electrodes (4.0 – 5.0 MΩ) were fabricated from 1.2 mm capillary glass using a P-97 (Sutter Instruments). The pipette solution contained the following (in mM) ...
-
bioRxiv - Neuroscience 2022Quote: ... fire-polished electrodes (1.0 - 2.0 MΩ) were fabricated from 1.7 mm capillary glass using a P-97 puller (Sutter Instruments), and the tips were coated with sticky wax (KerrLab ...
-
bioRxiv - Neuroscience 2021Quote: ... Drummond) was pulled to 10-20μm in tip diameter using a micropipette puller (Model P-97, Sutter instrument), and tip beveled to about 30 degrees ...
-
bioRxiv - Neuroscience 2022Quote: ... pulled from borosilicate glass with filament (O.D.: 1.0 mm, I.D.: 0.5 mm) using a P-97 micropipette puller (Sutter Instrument Company), was used.
-
bioRxiv - Neuroscience 2022Quote: ... pulled from borosilicate glass with filament (O.D.: 1.5 mm, I.D.: 0.86 mm) using a P-97 micropipette puller (Sutter Instrument Company) and filled with intracellular solution containing ...
-
bioRxiv - Neuroscience 2023Quote: Electrodes were pulled from filamented borosilicate glass capillaries (Warner Instruments) with a P-97 electrode puller (Sutter Instruments) to final resistances of 2.5–3.5 MΩ when filled with internal solutions ...
-
bioRxiv - Neuroscience 2023Quote: ... United States) were pulled using a Flaming-Brown P-97 pipette puller (Sutter Instruments, Novato, CA, United States) to produce long and thin pipettes for microinjection ...
-
bioRxiv - Developmental Biology 2024Quote: ... Science Products) were pulled with a horizontal pipette puller (Model P-97 Flaming Brown Micropipette Puller, Sutter Instrument). Pipettes had resistances between 4–6 MΩ when filled with solution containing (in mM) ...
-
bioRxiv - Neuroscience 2024Quote: ... Glass capillaries (3-000-203-G/X, Drummond) were pulled at a capillary puller (P-97, Sutter Instrument), their tips trimmed using a fine forceps and beveled at 30 degrees using an electric capillary beveler (EG-400 ...
-
bioRxiv - Neuroscience 2020Quote: ... Patch pipettes were pulled from borosilicate glass (OD: 1.5mm; ID: 0.86mm; Warner Instruments) on a Flaming-Brown P-97 pipette puller (Sutter Instruments), filled with pipette internal solution and had a resistance of 10 to 12 MΩ ...
-
bioRxiv - Neuroscience 2019Quote: ... from 1.5 mm/1.05 mm (OD/ID) borosilicate glass (Science Products) using a Sutter P-97 horizontal puller (Sutter Instruments). The intracellular solution contained (in mM) ...
-
A DNA-based optical nanosensor for in vivo imaging of acetylcholine in the peripheral nervous systembioRxiv - Bioengineering 2020Quote: ... A borosilicate glass tube with 1.0 mm/0.78 mm OD/ID was pulled using a P-97 micropipette puller (Sutter Instrument). Fig ...
-
bioRxiv - Neuroscience 2019Quote: ... Electrodes were pulled from borosilicate glass capillary (1.5 mm outer diameter, 0.64 mm wall thickness) using P-97 microelectrode puller (Sutter Instruments) and filled with intracellular solution containing (in mM) ...
-
bioRxiv - Neuroscience 2019Quote: ... pulled from borosilicate glass (1.2 mm outer diameter with 0.52 mm wall thickness) using P-97 puller from Sutter Instruments. Data was acquired through a differential AC amplifier (A-M Systems ...
-
bioRxiv - Neuroscience 2021Quote: Extracellular recordings were made with 4M NaCl filled borosilicate glass micropipettes (Flaming/Brown P-97 micropipette puller, Sutter Instruments). Field potentials were recorded simultaneously from the CA3 pyramidal and the V-VI mEC layers in three different connectivity states ...
-
bioRxiv - Neuroscience 2020Quote: ... we used sharp glass microelectrodes (BF120-60-10; shaped with a P-97 Brown/Fleming pipette puller, Sutter Instruments), which allowed penetrating the retina with little damage and provided for fairly long recordings (∼0.5-2 hours) ...
-
bioRxiv - Neuroscience 2020Quote: ... glass electrodes with tip size less than 0.5-micron were prepared by glass micropipette puller (P-97, Sutter Instrument), back-filled with mineral oil (16242 ...
-
bioRxiv - Neuroscience 2022Quote: ... Patch glass pipettes (4-9 MΩ, Hilgenberg) were pulled by a P-97 Flaming/Brown puller (Sutter Instruments, USA) from borosilicate glass capillaries and loaded with intracellular solution (ICS ...
-
bioRxiv - Neuroscience 2021Quote: ... Patch-pipettes were pulled from borosilicate glass (outer diameter 1.5 mm, inner diameter 0.8 mm; Science Products) with a P-97 Puller (Sutter Instruments) to resistances of 2 to 5 MΩ in bath and whole-cell series resistances ranging from 8 to 30 MΩ ...
-
bioRxiv - Pharmacology and Toxicology 2020Quote: ... Patch electrodes with resistances of 2-5 MΩ were pulled with a P-97 micropipette puller (Sutter Instruments, USA). The conventional whole-cell recordings were obtained by manual suction for hERG ...
-
bioRxiv - Neuroscience 2019Quote: Recording electrodes were pulled from borosilicate capillary tubes (O.D. = 1.5mm, I.D. = 0.86 mm) using a Flaming/Brown Model P-97 micropipette puller (Sutter Instrument, Novato, CA). Pipettes pulled to record from motoneurons and interneurons were within the range of 3–5 MΩ and 6–9 MΩ ...
-
bioRxiv - Pharmacology and Toxicology 2020Quote: ... Patch pipettes (2-4 MΩ) made from pulled (Model P-97 Flaming-Brown Micropipette Puller, Sutter Instruments, Novato, CA) and fire-polished borosilicate glass capillaries (World Precision Instruments ...
-
bioRxiv - Biochemistry 2021Quote: ... The glass pipettes were pulled to a suitable shape using a P-97 glass microelectrode puller (Sutter Instrument, Novato) and polished with an MF-830 (Narishige ...
-
bioRxiv - Developmental Biology 2021Quote: ... Injections were performed using a glass capillary needle pulled on a micropipette puller (Sutter Instrument Co. model P-97). Glass capillaries (1.2□mm OD ...
-
bioRxiv - Neuroscience 2020Quote: ... AAV virus (300nL volume) was then pressure injected 100nL/min via a glass pipette pulled (P-97 Sutter Instruments) from borosilicate capillaries (Drummond calibrated 5ul ...
-
bioRxiv - Developmental Biology 2020Quote: ... 1.0 OD x 0.58 ID x 15 L cm) in a needle puller (WPI Sutter instrument, Model P-97) and were back filled with 3 μl of injection solution ...
-
bioRxiv - Neuroscience 2022Quote: ... Drummond) was pulled to have a tip diameter of 25 μm using a micropipette puller (P-97, Sutter Instrument) and then beveled to a 30° tip ...
-
bioRxiv - Neuroscience 2022Quote: Patch pipettes were obtained from borosilicate glass capillaries (outer diameter = 1.5 mm, inner diameter = 1.05 mm) with a horizontal pipette puller (P-97, Sutter Instruments). The open-tip resistance of patch pipettes was 2.5–4.5 MΩ for somatic recordings ...
-
bioRxiv - Cancer Biology 2023Quote: The micropipette was fabricated from a glass capillary using a commercialized micropipette puller system (Model P-97, Sutter Instrument). The inner diameter of the micropipette tip is 2 μm ...